메뉴 건너뛰기




Volumn 59, Issue 4, 2012, Pages 3266-3274

Measuring venous blood volume changes during activation using hyperoxia

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTIC METHOD; ARTICLE; BLOOD OXYGENATION; BLOOD VOLUME; BOLD SIGNAL; BRAIN DEPTH STIMULATION; BRAIN MAPPING; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; HYPEROXIA; MALE; MATHEMATICAL COMPUTING; MOTOR PERFORMANCE; NORMAL HUMAN; OXYGEN BREATHING; OXYGEN SATURATION; PRIORITY JOURNAL; VENOUS BLOOD;

EID: 84855182294     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2011.11.041     Document Type: Article
Times cited : (21)

References (37)
  • 1
    • 0141729439 scopus 로고    scopus 로고
    • Impact of intravascular signal on quantitative measures of cerebral oxygen extraction and blood volume under normo- and hypercapnic conditions using an asymmetric spin echo approach
    • An H., Lin W. Impact of intravascular signal on quantitative measures of cerebral oxygen extraction and blood volume under normo- and hypercapnic conditions using an asymmetric spin echo approach. Magn. Reson. Med. 2003, 50:708-716.
    • (2003) Magn. Reson. Med. , vol.50 , pp. 708-716
    • An, H.1    Lin, W.2
  • 3
    • 67949094215 scopus 로고    scopus 로고
    • Perturbation of the BOLD response by a contrast agent and interpretation through a modified balloon model
    • Blockley N.P., Francis S.T., Gowland P.A. Perturbation of the BOLD response by a contrast agent and interpretation through a modified balloon model. NeuroImage 2009, 48:84-93.
    • (2009) NeuroImage , vol.48 , pp. 84-93
    • Blockley, N.P.1    Francis, S.T.2    Gowland, P.A.3
  • 4
    • 34547801878 scopus 로고    scopus 로고
    • Noninvasive measurement of arterial cerebral blood volume using Look-Locker EPI and arterial spin labeling
    • Brookes M.J., Morris P.G., Gowland P.A., Francis S.T. Noninvasive measurement of arterial cerebral blood volume using Look-Locker EPI and arterial spin labeling. Magn. Reson. Med. 2007, 58:41-54.
    • (2007) Magn. Reson. Med. , vol.58 , pp. 41-54
    • Brookes, M.J.1    Morris, P.G.2    Gowland, P.A.3    Francis, S.T.4
  • 5
    • 35148889974 scopus 로고    scopus 로고
    • Measurement of cerebral blood volume in humans using hyperoxic MRI contrast
    • Bulte D., Chiarelli P., Wise R., Jezzard P. Measurement of cerebral blood volume in humans using hyperoxic MRI contrast. J. Magn. Reson. Imaging 2007, 26:894-899.
    • (2007) J. Magn. Reson. Imaging , vol.26 , pp. 894-899
    • Bulte, D.1    Chiarelli, P.2    Wise, R.3    Jezzard, P.4
  • 7
    • 0031809018 scopus 로고    scopus 로고
    • Dynamics of blood flow and oxygenation changes during brain activation: the balloon model
    • Buxton R.B., Wong E.C., Frank L.R. Dynamics of blood flow and oxygenation changes during brain activation: the balloon model. Magn. Reson. Med. 1998, 39:855-864.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 855-864
    • Buxton, R.B.1    Wong, E.C.2    Frank, L.R.3
  • 8
  • 9
    • 33847694965 scopus 로고    scopus 로고
    • Flow-metabolism coupling in human visual, motor, and supplementary motor areas assessed by magnetic resonance imaging
    • Chiarelli P.A., Bulte D.P., Gallichan D., Piechnik S.K., Wise R., Jezzard P. Flow-metabolism coupling in human visual, motor, and supplementary motor areas assessed by magnetic resonance imaging. Magn. Reson. Med. 2007, 57:538-547.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 538-547
    • Chiarelli, P.A.1    Bulte, D.P.2    Gallichan, D.3    Piechnik, S.K.4    Wise, R.5    Jezzard, P.6
  • 10
    • 77950531739 scopus 로고    scopus 로고
    • The change in cerebrovascular reactivity between 3 T and 7 T measured using graded hypercapnia
    • Driver I., Blockley N., Fisher J., Francis S., Gowland P. The change in cerebrovascular reactivity between 3 T and 7 T measured using graded hypercapnia. NeuroImage 2010, 51:274-279.
    • (2010) NeuroImage , vol.51 , pp. 274-279
    • Driver, I.1    Blockley, N.2    Fisher, J.3    Francis, S.4    Gowland, P.5
  • 11
    • 33846085587 scopus 로고    scopus 로고
    • Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default state
    • He X., Yablonskiy D.A. Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default state. Magn. Reson. Med. 2006, 57:115-126.
    • (2006) Magn. Reson. Med. , vol.57 , pp. 115-126
    • He, X.1    Yablonskiy, D.A.2
  • 12
    • 81355156646 scopus 로고    scopus 로고
    • Decrease of Deoxy-Hemoglobin Containing Blood Volume in Activated Human Visual Cortex
    • He X., Yablonskiy D.A. Decrease of Deoxy-Hemoglobin Containing Blood Volume in Activated Human Visual Cortex. Proc. Intl. Soc. Mag. Reson. Med. 2010, 18:1119.
    • (2010) Proc. Intl. Soc. Mag. Reson. Med. , vol.18 , pp. 1119
    • He, X.1    Yablonskiy, D.A.2
  • 13
    • 22244436598 scopus 로고    scopus 로고
    • Hyperoxia-Induced Hypocapnia: an Underappreciated Risk
    • Iscoe S. Hyperoxia-Induced Hypocapnia: an Underappreciated Risk. Chest 2005, 128:430-433.
    • (2005) Chest , vol.128 , pp. 430-433
    • Iscoe, S.1
  • 14
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimization for the robust and accurate linear registration and motion correction of brain images
    • Jenkinson M., Bannister P., Brady M., Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage 2002, 17:825-841.
    • (2002) NeuroImage , vol.17 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.2    Brady, M.3    Smith, S.4
  • 15
    • 77952878029 scopus 로고    scopus 로고
    • 1rho-weighted fMRI
    • 1rho-weighted fMRI. NeuroImage 2010, 51:1378-1383.
    • (2010) NeuroImage , vol.51 , pp. 1378-1383
    • Jin, T.1    Kim, S.-G.2
  • 16
    • 79959630869 scopus 로고    scopus 로고
    • Temporal dynamics and spatial specificity of arterial and venous blood volume changes during visual stimulation: implication for BOLD quantification
    • Kim T., Kim S.-G. Temporal dynamics and spatial specificity of arterial and venous blood volume changes during visual stimulation: implication for BOLD quantification. J. Cereb. Blood Flow Metab. 2011, 31:1211-1222.
    • (2011) J. Cereb. Blood Flow Metab. , vol.31 , pp. 1211-1222
    • Kim, T.1    Kim, S.-G.2
  • 17
    • 34249315116 scopus 로고    scopus 로고
    • Arterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fMRI
    • Kim T., Hendrich K.S., Masamoto K., Kim S.-G. Arterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fMRI. J. Cereb. Blood Flow Metab. 2007, 27:1235-1247.
    • (2007) J. Cereb. Blood Flow Metab. , vol.27 , pp. 1235-1247
    • Kim, T.1    Hendrich, K.S.2    Masamoto, K.3    Kim, S.-G.4
  • 18
  • 19
    • 0035033892 scopus 로고    scopus 로고
    • Relative changes of cerebral arterial and venous blood volumes during increased cerebral blood flow: implications for BOLD fMRI
    • Lee S.P., Duong T.Q., Yang G., Iadecola C., Kim S.-G. Relative changes of cerebral arterial and venous blood volumes during increased cerebral blood flow: implications for BOLD fMRI. Magn. Reson. Med. 2001, 45:791-800.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 791-800
    • Lee, S.P.1    Duong, T.Q.2    Yang, G.3    Iadecola, C.4    Kim, S.-G.5
  • 20
    • 0041591021 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging based on changes in vascular space occupancy
    • Lu H., Golay X., Pekar J.J., van Zijl P.C.M. Functional magnetic resonance imaging based on changes in vascular space occupancy. Magn. Reson. Med. 2003, 50:263-274.
    • (2003) Magn. Reson. Med. , vol.50 , pp. 263-274
    • Lu, H.1    Golay, X.2    Pekar, J.J.3    van Zijl, P.C.M.4
  • 22
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model
    • Ogawa S., Menon R.S., Tank D.W., Kim S.-G., Merkle H., Ellermann J.M., Ugurbil K. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. Biophys. J. 1993, 64:803-812.
    • (1993) Biophys. J. , vol.64 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3    Kim, S.-G.4    Merkle, H.5    Ellermann, J.M.6    Ugurbil, K.7
  • 24
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • Petersen E.T., Lim T., Golay X. Model-free arterial spin labeling quantification approach for perfusion MRI. Magn. Reson. Med. 2006, 55:219-232.
    • (2006) Magn. Reson. Med. , vol.55 , pp. 219-232
    • Petersen, E.T.1    Lim, T.2    Golay, X.3
  • 25
    • 41849109896 scopus 로고    scopus 로고
    • Volume parcellation for improved dynamic shimming
    • Poole M., Bowtell R. Volume parcellation for improved dynamic shimming. MAGMA 2008, 21:31-40.
    • (2008) MAGMA , vol.21 , pp. 31-40
    • Poole, M.1    Bowtell, R.2
  • 27
    • 0032759720 scopus 로고    scopus 로고
    • Titration of the BOLD effect: separation and quantitation of blood volume and oxygenation changes in the human cerebral cortex during neuronal activation and ferumoxide infusion
    • Scheffler K., Seifritz E., Haselhorst R., Bilecen D. Titration of the BOLD effect: separation and quantitation of blood volume and oxygenation changes in the human cerebral cortex during neuronal activation and ferumoxide infusion. Magn. Reson. Med. 1999, 42:829-836.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 829-836
    • Scheffler, K.1    Seifritz, E.2    Haselhorst, R.3    Bilecen, D.4
  • 28
    • 0018399378 scopus 로고
    • Simple, accurate equations for human blood O2 dissociation computations
    • Severinghaus J.W. Simple, accurate equations for human blood O2 dissociation computations. J. Appl. Physiol. 1979, 46:599-602.
    • (1979) J. Appl. Physiol. , vol.46 , pp. 599-602
    • Severinghaus, J.W.1
  • 29
    • 0037371755 scopus 로고    scopus 로고
    • Effects of hematocrit and oxygen saturation level on blood spin-lattice relaxation
    • Silvennoinen M.J., Kettunen M.I., Kauppinen R.A. Effects of hematocrit and oxygen saturation level on blood spin-lattice relaxation. Magn. Reson. Med. 2003, 49:568-571.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 568-571
    • Silvennoinen, M.J.1    Kettunen, M.I.2    Kauppinen, R.A.3
  • 30
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction
    • Smith S.M. Fast robust automated brain extraction. Hum. Brain Mapp. 2002, 17:143-155.
    • (2002) Hum. Brain Mapp. , vol.17 , pp. 143-155
    • Smith, S.M.1
  • 32
    • 12844276018 scopus 로고    scopus 로고
    • Venous refocusing for volume estimation: VERVE functional magnetic resonance imaging
    • Stefanovic B., Pike G.B. Venous refocusing for volume estimation: VERVE functional magnetic resonance imaging. Magn. Reson. Med. 2005, 53:339-347.
    • (2005) Magn. Reson. Med. , vol.53 , pp. 339-347
    • Stefanovic, B.1    Pike, G.B.2
  • 33
    • 0036424775 scopus 로고    scopus 로고
    • Fast, fully automated global and local magnetic field optimization for fMRI of the human brain
    • Wilson J.L., Jenkinson M., de Araujo I., Kringelbach M.L., Rolls E.T., Jezzard P. Fast, fully automated global and local magnetic field optimization for fMRI of the human brain. NeuroImage 2002, 17:967-976.
    • (2002) NeuroImage , vol.17 , pp. 967-976
    • Wilson, J.L.1    Jenkinson, M.2    de Araujo, I.3    Kringelbach, M.L.4    Rolls, E.T.5    Jezzard, P.6
  • 34
    • 0035212159 scopus 로고    scopus 로고
    • Temporal autocorrelation in univariate linear modeling of FMRI data
    • Woolrich M.W., Ripley B.D., Brady M., Smith S.M. Temporal autocorrelation in univariate linear modeling of FMRI data. NeuroImage 2001, 14:1370-1386.
    • (2001) NeuroImage , vol.14 , pp. 1370-1386
    • Woolrich, M.W.1    Ripley, B.D.2    Brady, M.3    Smith, S.M.4
  • 35
    • 0031907230 scopus 로고    scopus 로고
    • Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study
    • Yablonskiy D.A. Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study. Magn. Reson. Med. 1998, 39:417-428.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 417-428
    • Yablonskiy, D.A.1
  • 36
    • 0027973923 scopus 로고
    • Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime
    • Yablonskiy D.A., Haacke E.M. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn. Reson. Med. 1994, 32:749-763.
    • (1994) Magn. Reson. Med. , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.