메뉴 건너뛰기




Volumn 22, Issue 8, 2013, Pages 1068-1077

Accuracy and reliability of postoperative radiographic measurements of glenoid anatomy and relationships in patients with total shoulder arthroplasty

Author keywords

3D computed tomography; Development of Diagnostic Criteria; Diagnostic Study; Glenoid version; Humeral head registration; Level II; Shoulder arthroplasty; X ray

Indexed keywords

ABDUCTION; ACCURACY; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CORRELATION COEFFICIENT; FOLLOW UP; HUMAN; HUMERUS HEAD; IMAGE ANALYSIS; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RETROSPECTIVE STUDY; ROTATION; SHOULDER; SHOULDER ARTHROPLASTY; SHOULDER RADIOGRAPHY;

EID: 84880510271     PISSN: 10582746     EISSN: 15326500     Source Type: Journal    
DOI: 10.1016/j.jse.2012.11.015     Document Type: Article
Times cited : (55)

References (22)
  • 1
    • 24044503376 scopus 로고    scopus 로고
    • Three-dimensional invivo displacements of the shoulder complex from biplanar radiography
    • Berthonnaud E., Herzberg G., Zhao K.D., An K.N., Dimnet J. Three-dimensional invivo displacements of the shoulder complex from biplanar radiography. Surg Radiol Anat 2005, 27:214-222. 10.1007/s00276-005-0315-x.
    • (2005) Surg Radiol Anat , vol.27 , pp. 214-222
    • Berthonnaud, E.1    Herzberg, G.2    Zhao, K.D.3    An, K.N.4    Dimnet, J.5
  • 2
    • 79955855889 scopus 로고    scopus 로고
    • Comparison of standard two-dimensional and three-dimensional corrected glenoid version measurements
    • Budge M.D., Lewis G.S., Schaefer E., Coquia S., Flemming D.J., Armstrong A.D. Comparison of standard two-dimensional and three-dimensional corrected glenoid version measurements. J Shoulder Elbow Surg 2011, 20:577-583. 10.1016/j.jse.2010.11.003.
    • (2011) J Shoulder Elbow Surg , vol.20 , pp. 577-583
    • Budge, M.D.1    Lewis, G.S.2    Schaefer, E.3    Coquia, S.4    Flemming, D.J.5    Armstrong, A.D.6
  • 3
    • 42649083652 scopus 로고    scopus 로고
    • The radiographic acromiohumeral interval is affected by arm and radiographic beam position
    • Fehringer E.V., Rosipal C.E., Rhodes D.A., Lauder A.J., Puumala S.E., Feschuk C.A., et al. The radiographic acromiohumeral interval is affected by arm and radiographic beam position. Skeletal Radiol 2008, 37:535-539. 10.1007/s00256-008-0467-y.
    • (2008) Skeletal Radiol , vol.37 , pp. 535-539
    • Fehringer, E.V.1    Rosipal, C.E.2    Rhodes, D.A.3    Lauder, A.J.4    Puumala, S.E.5    Feschuk, C.A.6
  • 4
    • 0026786765 scopus 로고
    • The use of computerized tomography in the measurement of glenoid version
    • Friedman R.J., Hawthorne K.B., Genez B.M. The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg Am 1992, 74:1032-1037.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1032-1037
    • Friedman, R.J.1    Hawthorne, K.B.2    Genez, B.M.3
  • 5
    • 79151478729 scopus 로고    scopus 로고
    • Predicting normal glenoid version from the pathologic scapula: a comparison of 4 methods in 2- and 3-dimensional models
    • Ganapathi A., McCarron J.A., Chen X., Iannotti J.P. Predicting normal glenoid version from the pathologic scapula: a comparison of 4 methods in 2- and 3-dimensional models. J Shoulder Elbow Surg 2011, 20:234-244. 10.1016/j.jse.2010.05.024.
    • (2011) J Shoulder Elbow Surg , vol.20 , pp. 234-244
    • Ganapathi, A.1    McCarron, J.A.2    Chen, X.3    Iannotti, J.P.4
  • 6
    • 72049122722 scopus 로고    scopus 로고
    • Glenoid loosening after total shoulder arthroplasty: an invitro CT-scan study
    • Gregory T., Hansen U., Taillieu F., Baring T., Brassart N., Mutchleret C., et al. Glenoid loosening after total shoulder arthroplasty: an invitro CT-scan study. J Orthop Res 2009, 27:1589-1595. 10.1002/jor.20912.
    • (2009) J Orthop Res , vol.27 , pp. 1589-1595
    • Gregory, T.1    Hansen, U.2    Taillieu, F.3    Baring, T.4    Brassart, N.5    Mutchleret, C.6
  • 7
    • 76949096726 scopus 로고    scopus 로고
    • Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty
    • Hoenecke H.R., Hermida J.C., Flores-Hernandez C., D'Lima D.D. Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. J Shoulder Elbow Surg 2010, 19:166-171. 10.1016/j.jse.2009.08.009.
    • (2010) J Shoulder Elbow Surg , vol.19 , pp. 166-171
    • Hoenecke, H.R.1    Hermida, J.C.2    Flores-Hernandez, C.3    D'Lima, D.D.4
  • 8
    • 9644262410 scopus 로고    scopus 로고
    • The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty
    • Hopkins A.R., Hansen U.N., Amis A.A., Emery R. The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. J Shoulder Elbow Surg 2004, 13:668-675. 10.1016/S1058274604001399.
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 668-675
    • Hopkins, A.R.1    Hansen, U.N.2    Amis, A.A.3    Emery, R.4
  • 9
    • 0023839106 scopus 로고
    • Normal and abnormal mechanics of the glenohumeral joint in the horizontal plane
    • Howell S.M., Galinat B.J., Renzi A.J., Marone P.J. Normal and abnormal mechanics of the glenohumeral joint in the horizontal plane. J Bone Joint Surg Am 1988, 70:227-232.
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 227-232
    • Howell, S.M.1    Galinat, B.J.2    Renzi, A.J.3    Marone, P.J.4
  • 10
    • 83555174558 scopus 로고    scopus 로고
    • Effect of glenoid deformity on glenoid component placement in primary shoulder arthroplasty
    • Iannotti J.P., Greeson C., Downing D., Sabesan V., Bryan J.A. Effect of glenoid deformity on glenoid component placement in primary shoulder arthroplasty. J Shoulder Elbow Surg 2012, 21:48-55. 10.1016/j.jse.2011.02.011.
    • (2012) J Shoulder Elbow Surg , vol.21 , pp. 48-55
    • Iannotti, J.P.1    Greeson, C.2    Downing, D.3    Sabesan, V.4    Bryan, J.A.5
  • 11
    • 84884353290 scopus 로고    scopus 로고
    • Development and validation of a new method of three-dimensional assessment of glenoid and humeral component position after total shoulder arthroplasty
    • ( in press).doi:10.1016/j.jse.2013.01.005
    • Iannotti J.P., Ricchetti E.T., Rodriguez E.J., Bryan J.A. Development and validation of a new method of three-dimensional assessment of glenoid and humeral component position after total shoulder arthroplasty. J Shoulder Elbow Surg 2013, ( in press). doi:10.1016/j.jse.2013.01.005.
    • (2013) J Shoulder Elbow Surg
    • Iannotti, J.P.1    Ricchetti, E.T.2    Rodriguez, E.J.3    Bryan, J.A.4
  • 12
    • 68349143243 scopus 로고    scopus 로고
    • Effect of a variable prosthetic neck-shaft angle and the surgical technique on replication of normal humeral anatomy
    • Jeong J., Bryan J., Iannotti J.P. Effect of a variable prosthetic neck-shaft angle and the surgical technique on replication of normal humeral anatomy. J Bone Joint Surg Am 2009, 91:1932-1941. 10.2106/JBJS.H.00729.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 1932-1941
    • Jeong, J.1    Bryan, J.2    Iannotti, J.P.3
  • 14
    • 13844270863 scopus 로고    scopus 로고
    • Use of three-dimensional computed tomography for the analysis of the glenoid anatomy
    • Kwon Y.W., Powell K.A., Yum J.K., Brems J.J., Iannotti J.P. Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elbow Surg 2005, 14:85-90. 10.1016/j.jse.2004.04.011.
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 85-90
    • Kwon, Y.W.1    Powell, K.A.2    Yum, J.K.3    Brems, J.J.4    Iannotti, J.P.5
  • 15
    • 0033804579 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of glenoid replacement prostheses: a comparison of keeled and pegged anchorage systems
    • Lacroix D., Murphy L.A., Prendergast P.J. Three-dimensional finite element analysis of glenoid replacement prostheses: a comparison of keeled and pegged anchorage systems. J Biomech Eng 2000, 122:430-436.
    • (2000) J Biomech Eng , vol.122 , pp. 430-436
    • Lacroix, D.1    Murphy, L.A.2    Prendergast, P.J.3
  • 16
    • 34247622237 scopus 로고    scopus 로고
    • Evaluation of the glenoid implant survival using a biomechanical finite element analysis: influence of the implant design, bone properties, and loading location
    • Mansat P., Briot J., Mansat M., Swider P. Evaluation of the glenoid implant survival using a biomechanical finite element analysis: influence of the implant design, bone properties, and loading location. J Shoulder Elbow Surg 2007, 16(3 Suppl):S79-S83. 10.1016/j.jse.2005.11.010.
    • (2007) J Shoulder Elbow Surg , vol.16 , Issue.3 SUPPL.
    • Mansat, P.1    Briot, J.2    Mansat, M.3    Swider, P.4
  • 18
    • 0141892870 scopus 로고    scopus 로고
    • Measurement of glenoid version: conventional radiographs versus computed tomography scans
    • Nyffeler R.W., Jost B., Pfirrmann C.W.A., Gerber C. Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elbow Surg 2003, 12:493-496. 10.1016/S1058274603001812.
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 493-496
    • Nyffeler, R.W.1    Jost, B.2    Pfirrmann, C.W.A.3    Gerber, C.4
  • 20
    • 34247587093 scopus 로고    scopus 로고
    • Biomechanical effects of glenoid retroversion in total shoulder arthroplasty
    • Shapiro T.A., McGarry M.H., Gupta R., Lee Y.S., Lee T.Q. Biomechanical effects of glenoid retroversion in total shoulder arthroplasty. JShoulder Elbow Surg 2007, 16(3 Suppl):S90-S95. 10.1016/j.jse.2006.07.010.
    • (2007) JShoulder Elbow Surg , vol.16 , Issue.3 SUPPL.
    • Shapiro, T.A.1    McGarry, M.H.2    Gupta, R.3    Lee, Y.S.4    Lee, T.Q.5
  • 22
    • 51249111981 scopus 로고    scopus 로고
    • Functional malcentering of the humeral head and asymmetric long-term stress on the glenoid: potential reasons for glenoid loosening in total shoulder arthroplasty
    • von Eisenhart-Rothe R., Müller-Gerbl M., Wiedemann E., Englmeier K.-H., Graichen H. Functional malcentering of the humeral head and asymmetric long-term stress on the glenoid: potential reasons for glenoid loosening in total shoulder arthroplasty. J Shoulder Elbow Surg 2008, 17:695-702. 10.1016/j.jse.2008.02.008.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 695-702
    • von Eisenhart-Rothe, R.1    Müller-Gerbl, M.2    Wiedemann, E.3    Englmeier, K.-H.4    Graichen, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.