메뉴 건너뛰기




Volumn 20, Issue 4, 2011, Pages 577-583

Comparison of standard two-dimensional and three-dimensional corrected glenoid version measurements

Author keywords

3D reconstruction; Glenoid component; Glenoid version; Level III Retrospective Study of Non Consecutive Patients; Placement; Total shoulder arthroplasty

Indexed keywords

ARTICLE; CADAVER; CLINICAL ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; HUMAN; INTERMETHOD COMPARISON; PRIORITY JOURNAL; RELIABILITY; SCAPULA; SHOULDER; THREE DIMENSIONAL IMAGING;

EID: 79955855889     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2010.11.003     Document Type: Article
Times cited : (172)

References (26)
  • 2
    • 0033218441 scopus 로고    scopus 로고
    • Variability of measurement of glenoid version on computed tomography scan
    • Bokor D.J., O'Sullivan M.D., Hazan G.J. Variability of measurement of glenoid version on computed tomography scan. J Shoulder Elbow Surg 1999, 8:595-598. 10.1016/S1058-2746(99)90096-4.
    • (1999) J Shoulder Elbow Surg , vol.8 , pp. 595-598
    • Bokor, D.J.1    O'Sullivan, M.D.2    Hazan, G.J.3
  • 3
    • 77950900574 scopus 로고    scopus 로고
    • Two-dimensional glenoid version measurements vary with coronal and sagittal scapula rotation
    • Bryce C.D., Davison A.C., Wang L., Flemming D.J., Armstrong A.D. Two-dimensional glenoid version measurements vary with coronal and sagittal scapula rotation. J Bone Joint Surg Am 2010, 92:692-699. 10.2106/JBJS.I.00177.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 692-699
    • Bryce, C.D.1    Davison, A.C.2    Wang, L.3    Flemming, D.J.4    Armstrong, A.D.5
  • 5
    • 0033760895 scopus 로고    scopus 로고
    • Morphological and mechanical analysis of the glenoid by 3D geometric reconstruction using computed tomography
    • Couteau B., Mansat P., Darmana R., Mansat M., Egan J. Morphological and mechanical analysis of the glenoid by 3D geometric reconstruction using computed tomography. Clin Biomech (Bristol, Avon) 2000, 15(suppl 1):S8-12. 10.1016/S0268-0033(00)00052-8.
    • (2000) Clin Biomech (Bristol, Avon) , vol.15 , Issue.SUPPL. 1
    • Couteau, B.1    Mansat, P.2    Darmana, R.3    Mansat, M.4    Egan, J.5
  • 6
    • 0035293060 scopus 로고    scopus 로고
    • In vivo characterization of glenoid with use of computed tomography
    • Couteau B., Mansat P., Mansat M., Darmana R., Egan J. In vivo characterization of glenoid with use of computed tomography. J Shoulder Elbow Surg 2001, 10:116-122. 10.1067/mse.2001.112884.
    • (2001) J Shoulder Elbow Surg , vol.10 , pp. 116-122
    • Couteau, B.1    Mansat, P.2    Mansat, M.3    Darmana, R.4    Egan, J.5
  • 9
    • 33745736595 scopus 로고    scopus 로고
    • Risks of loosening of a prosthetic glenoid implanted in retroversion
    • Farron A., Terrier A., Buchler P. Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elbow Surg 2006, 15:521-526. 10.1016/j.jse.2005.10.003.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 521-526
    • Farron, A.1    Terrier, A.2    Buchler, P.3
  • 10
    • 0026786765 scopus 로고
    • The use of computerized tomography in the measurement of glenoid version
    • Friedman R.J., Hawthorne K.B., Genez B.M. The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg Am 1992, 74:1032-1037.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1032-1037
    • Friedman, R.J.1    Hawthorne, K.B.2    Genez, B.M.3
  • 12
    • 76949096726 scopus 로고    scopus 로고
    • Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty
    • Hoenecke H.R., Hermida J.C., Flores-Hernandez C., D'Lima D.D. Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. J Shoulder Elbow Surg 2010, 19:166-171. 10.1016/j.jse.2009.08.009.
    • (2010) J Shoulder Elbow Surg , vol.19 , pp. 166-171
    • Hoenecke, H.R.1    Hermida, J.C.2    Flores-Hernandez, C.3    D'Lima, D.D.4
  • 13
    • 9644262410 scopus 로고    scopus 로고
    • The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty
    • Hopkins A.R., Hansen U.N., Amis A.A., Emery R. The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. J Shoulder Elbow Surg 2004, 13:668-675. 10.1016/S1058274604001399.
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 668-675
    • Hopkins, A.R.1    Hansen, U.N.2    Amis, A.A.3    Emery, R.4
  • 14
    • 0034839313 scopus 로고    scopus 로고
    • Evaluation of three-dimensional glenoid structure using MRI
    • Inui H., Sugamoto K., Miyamoto T., Machida A., Hashimoto J., Nobuhara K. Evaluation of three-dimensional glenoid structure using MRI. J Anat 2001, 1991:323-328. 10.1017/s002187820100810X.
    • (2001) J Anat , vol.1991 , pp. 323-328
    • Inui, H.1    Sugamoto, K.2    Miyamoto, T.3    Machida, A.4    Hashimoto, J.5    Nobuhara, K.6
  • 15
    • 67449119189 scopus 로고    scopus 로고
    • Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study
    • Kircher J., Wiedemann M., Magosch P., Lichtenberg S., Habermeyer P. Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Shoulder Elbow Surgery 2009, 18:515-520. 10.1016/j.jse.2009.03.014.
    • (2009) J Shoulder Elbow Surgery , vol.18 , pp. 515-520
    • Kircher, J.1    Wiedemann, M.2    Magosch, P.3    Lichtenberg, S.4    Habermeyer, P.5
  • 16
    • 13844270863 scopus 로고    scopus 로고
    • Use of three-dimensional computed tomography for the analysis of the glenoid anatomy
    • Kwon Y.W., Powell K.A., Yum J.K., Brems J.J., Iannotti J.P. Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elbow Surg 2005, 14:85-90. 10.1016/j.jse.2004.04.011.
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 85-90
    • Kwon, Y.W.1    Powell, K.A.2    Yum, J.K.3    Brems, J.J.4    Iannotti, J.P.5
  • 17
    • 78649817571 scopus 로고    scopus 로고
    • Glenoid spherical orientation and version
    • [Epub ahead of print]. doi:10.1016/j.jse.2010.05.012
    • Lewis G.S., Armstrong A.A. Glenoid spherical orientation and version. J Shoulder Elbow Surg 2010, [Epub ahead of print]. doi:10.1016/j.jse.2010.05.012.
    • (2010) J Shoulder Elbow Surg
    • Lewis, G.S.1    Armstrong, A.A.2
  • 18
    • 68749115020 scopus 로고    scopus 로고
    • Simulation of surgical glenoid resurfacing using three-dimensional computed tomography of the arthritic glenohumeral joint: The amount of glenoid retroversion that can be corrected
    • Nowak D.D., Bahu M.J., Gardner T.R., Dyrszka M.D., Levine W.N., Bigliani L.U., et al. Simulation of surgical glenoid resurfacing using three-dimensional computed tomography of the arthritic glenohumeral joint: The amount of glenoid retroversion that can be corrected. J Shoulder Elbow Surg 2009, 18:680-688. 10.1016/j.jse.2009.03.019.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 680-688
    • Nowak, D.D.1    Bahu, M.J.2    Gardner, T.R.3    Dyrszka, M.D.4    Levine, W.N.5    Bigliani, L.U.6
  • 19
    • 0141892870 scopus 로고    scopus 로고
    • Measurement of glenoid version: Conventional radiographs versus computed tomography scans
    • Nyffeler R.W., Jost B., Pfirrmann C.W.A., Gerber C. Measurement of glenoid version: Conventional radiographs versus computed tomography scans. J Shoulder Elbow Surg 2003, 12:493-496. 10.1016/S1058274603001812.
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 493-496
    • Nyffeler, R.W.1    Jost, B.2    Pfirrmann, C.W.A.3    Gerber, C.4
  • 20
    • 33748438366 scopus 로고    scopus 로고
    • Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study
    • Nyffleler R.W., Sheikh R., Atkinson T.S., Jacob H.A., Favre P., Gerber C. Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study. J Shoulder Elbow Surg 2006, 15:625-629. 10.1016/j.jse.2005.09.016.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 625-629
    • Nyffleler, R.W.1    Sheikh, R.2    Atkinson, T.S.3    Jacob, H.A.4    Favre, P.5    Gerber, C.6
  • 21
    • 78149409347 scopus 로고    scopus 로고
    • Glenoid version: how to measure it? Validity of different methods in two-dimensional computed tomography scans
    • Rouleau D.M., Kidder J.F., Pons-Villanueva J., Dynamidis S., Defranco M., Walch G. Glenoid version: how to measure it? Validity of different methods in two-dimensional computed tomography scans. J Shoulder Elbow Surg 2010, 19:1230-1237. 10.1016/j.jse.2010.01.027.
    • (2010) J Shoulder Elbow Surg , vol.19 , pp. 1230-1237
    • Rouleau, D.M.1    Kidder, J.F.2    Pons-Villanueva, J.3    Dynamidis, S.4    Defranco, M.5    Walch, G.6
  • 22
    • 55849117313 scopus 로고    scopus 로고
    • The influence of three-dimensional computed tomography images of the shoulder in preoperative planning for total shoulder arthroplasty
    • Scalise J.J., Codsi M.J., Bryan J., Brems J.J., Iannotti J.P. The influence of three-dimensional computed tomography images of the shoulder in preoperative planning for total shoulder arthroplasty. J Bone Joint Surg Am 2008, 90:2438-2445. 10.2106/JBJS.G.01341.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2438-2445
    • Scalise, J.J.1    Codsi, M.J.2    Bryan, J.3    Brems, J.J.4    Iannotti, J.P.5
  • 23
    • 42749093373 scopus 로고    scopus 로고
    • The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis
    • Scalise J.J., Codsi M.J., Bryan J., Iannotti J.P. The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis. J Shoulder Elbow Surg 2008, 17:487-491. 10.1016/j.jse.2007.09.006.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 487-491
    • Scalise, J.J.1    Codsi, M.J.2    Bryan, J.3    Iannotti, J.P.4
  • 24
    • 34247587093 scopus 로고    scopus 로고
    • Biomechanical effects of glenoid retroversion in total shoulder arthroplasty
    • Shapiro T.A., McGarry M.H., Gupta R., Lee Y.S., Lee T.Q. Biomechanical effects of glenoid retroversion in total shoulder arthroplasty. J Shoulder Elbow Surg 2007, 16:90S-95S. 10.1016/j.jse.2006.07.010.
    • (2007) J Shoulder Elbow Surg , vol.16
    • Shapiro, T.A.1    McGarry, M.H.2    Gupta, R.3    Lee, Y.S.4    Lee, T.Q.5
  • 26
    • 24644469503 scopus 로고    scopus 로고
    • Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement
    • Yian E.H., Werner C.L., Nyffeler R.W., Pfirrmann C.W., Ramappa A., Sukthankar A., et al. Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am 2005, 81:1928-1936. 10.2106/JBJS.D.02675.
    • (2005) J Bone Joint Surg Am , vol.81 , pp. 1928-1936
    • Yian, E.H.1    Werner, C.L.2    Nyffeler, R.W.3    Pfirrmann, C.W.4    Ramappa, A.5    Sukthankar, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.