메뉴 건너뛰기




Volumn 15, Issue 1, 2013, Pages

Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields

Author keywords

Cardiovascular magnetic resonance; Flow artifacts; High magnetic field; Retrospective gating; Self gated cine UTE

Indexed keywords

ANIMAL TISSUE; AORTA VALVE; ARTICLE; CARDIAC RESPIRATORY SELF GATED CINE ULTRA SHORT ECHO TIME CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR PARAMETERS; ECHOCARDIOGRAPHY; FEMALE; HEART CYCLE; HEART EJECTION FRACTION; HEART MUSCLE; HEART OUTPUT; HEART STROKE VOLUME; IMAGE QUALITY; MAGNETIC FIELD; MOUSE; NONHUMAN; PRIORITY JOURNAL; ANIMAL; ANIMAL MODEL; ARTIFACT; BREATHING RATE; C57BL MOUSE; CARDIAC GATED IMAGING; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DOPPLER ECHOCARDIOGRAPHY; EVALUATION STUDY; HEART CONTRACTION; HEART LEFT VENTRICLE FUNCTION; HEART RATE; HEART RIGHT VENTRICLE FUNCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PREDICTIVE VALUE; PROCEDURES; REPRODUCIBILITY; SIGNAL NOISE RATIO; TIME;

EID: 84879834002     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-15-59     Document Type: Article
Times cited : (34)

References (44)
  • 1
    • 78650345960 scopus 로고    scopus 로고
    • Toward cardiovascular MRI at 7 T: Clinical needs, technical solutions and research promises
    • 10.1007/s00330-010-1902-8 20676653
    • Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises. Niendorf T, Sodickson DK, Krombach GA, Schulz-Menger J, Eur Radiol 2010 20 2806 2816 10.1007/s00330-010-1902-8 20676653
    • (2010) Eur Radiol , vol.20 , pp. 2806-2816
    • Niendorf, T.1    Sodickson, D.K.2    Krombach, G.A.3    Schulz-Menger, J.4
  • 2
    • 84859646398 scopus 로고    scopus 로고
    • 7-T MR - From research to clinical applications?
    • 10.1002/nbm.1794 22102481
    • 7-T MR-from research to clinical applications? Moser E, Stahlberg F, Ladd ME, Trattnig S, NMR Biomed 2012 25 695 716 10.1002/nbm.1794 22102481
    • (2012) NMR Biomed , vol.25 , pp. 695-716
    • Moser, E.1    Stahlberg, F.2    Ladd, M.E.3    Trattnig, S.4
  • 4
    • 66249132716 scopus 로고    scopus 로고
    • Advanced methods for quantification of infarct size in mice using three-dimensional high-field late gadolinium enhancement MRI
    • 10.1152/ajpheart.01294.2008 19218501
    • Advanced methods for quantification of infarct size in mice using three-dimensional high-field late gadolinium enhancement MRI. Bohl S, Lygate CA, Barnes H, Medway D, Stork LA, Schulz-Menger J, Neubauer S, Schneider JE, Am J Physiol Heart Circ Physiol 2009 296 1200 H1208 10.1152/ajpheart.01294.2008 19218501
    • (2009) Am J Physiol Heart Circ Physiol , vol.296
    • Bohl, S.1    Lygate, C.A.2    Barnes, H.3    Medway, D.4    Stork, L.A.5    Schulz-Menger, J.6    Neubauer, S.7    Schneider, J.E.8
  • 5
    • 36849061211 scopus 로고    scopus 로고
    • Improved cardiac tagging resolution at ultra-high magnetic field elucidates transmural differences in principal strain in the mouse heart and reduced stretch in dilated cardiomyopathy
    • DOI 10.1080/10976640701693683, PII 786988739
    • Improved cardiac tagging resolution at ultra-high magnetic field elucidates transmural differences in principal strain in the mouse heart and reduced stretch in dilated cardiomyopathy. Hankiewicz JH, Lewandowski ED, J Cardiovasc Magn Reson 2007 9 883 890 10.1080/10976640701693683 18066748 (Pubitemid 350232929)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.6 , pp. 883-890
    • Hankiewicz, J.H.1    Lewandowski, E.D.2
  • 10
    • 44949196855 scopus 로고    scopus 로고
    • Respiratory self-gated four-dimensional coronary MR angiography: A feasibility study
    • DOI 10.1002/mrm.21617
    • Respiratory self-gated four-dimensional coronary MR angiography: a feasibility study. Lai P, Larson AC, Park J, Carr JC, Li D, Magn Reson Med 2008 59 1378 1385 10.1002/mrm.21617 18506786 (Pubitemid 351813268)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.6 , pp. 1378-1385
    • Lai, P.1    Larson, A.C.2    Park, J.3    Carr, J.C.4    Li, D.5
  • 11
    • 74049152552 scopus 로고    scopus 로고
    • Aortic valve stenotic area calculation from phase contrast cardiovascular magnetic resonance: The importance of short echo time
    • 10.1186/1532-429X-11-49 19925667
    • Aortic valve stenotic area calculation from phase contrast cardiovascular magnetic resonance: the importance of short echo time. O'Brien KR, Gabriel RS, Greiser A, Cowan BR, Young AA, Kerr AJ, J Cardiovasc Magn Reson 2009 11 49 60 10.1186/1532-429X-11-49 19925667
    • (2009) J Cardiovasc Magn Reson , vol.11 , pp. 49-60
    • O'Brien, K.R.1    Gabriel, R.S.2    Greiser, A.3    Cowan, B.R.4    Young, A.A.5    Kerr, A.J.6
  • 12
    • 0242499346 scopus 로고    scopus 로고
    • Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
    • DOI 10.1097/00004728-200311000-00001
    • Magnetic resonance: An introduction to ultrashort TE (UTE) imaging. Robson MD, Gatehouse PD, Bydder M, Bydder GM, J Comput Assist Tomogr 2003 27 825 846 10.1097/00004728-200311000-00001 14600447 (Pubitemid 37420776)
    • (2003) Journal of Computer Assisted Tomography , vol.27 , Issue.6 , pp. 825-846
    • Robson, M.D.1    Gatehouse, P.D.2    Bydder, M.3    Bydder, G.M.4
  • 13
    • 60549089990 scopus 로고    scopus 로고
    • Assessment of anterior cruciate ligament reconstruction using 3D ultrashort echo-time MR imaging
    • 10.1002/jmri.21653 19161200
    • Assessment of anterior cruciate ligament reconstruction using 3D ultrashort echo-time MR imaging. Rahmer J, Börnert P, Dries SP, J Magn Reson Imaging 2009 29 443 448 10.1002/jmri.21653 19161200
    • (2009) J Magn Reson Imaging , vol.29 , pp. 443-448
    • Rahmer, J.1    Börnert, P.2    Dries, S.P.3
  • 15
    • 0033026560 scopus 로고    scopus 로고
    • Ultra-short echo-time 2D time-of-flight MR angiography using a half- pulse excitation
    • DOI 10.1002/(SICI)1522-2594(199903)41:3<591::AID-MRM23>3.0.CO;2-R
    • Ultrashort echo-time 2D time-of-flight MR angiography using a half-pulse excitation. Nielsen HT, Gold GE, Olcott EW, Pauly JM, Nishimura DG, Magn Reson Med 1999 41 591 599 10.1002/(SICI)1522-2594(199903)41:3<591::AID-MRM23>3. 0.CO;2-R 10204884 (Pubitemid 29152904)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.3 , pp. 591-599
    • Nielsen, H.T.C.1    Gold, G.E.2    Olcott, E.W.3    Pauly, J.M.4    Nishimura, D.G.5
  • 16
    • 79958256467 scopus 로고    scopus 로고
    • Optimization of iron oxide nanoparticle detection using ultrashort echo time pulse sequences: Comparison of T(1), T(2)*, and synergistic T(1) - T(2)* contrast mechanisms
    • 10.1002/mrm.22755 21305596
    • Optimization of iron oxide nanoparticle detection using ultrashort echo time pulse sequences: comparison of T(1), T(2)*, and synergistic T(1)-T(2)* contrast mechanisms. Girard OM, Du J, Agemy L, Sugahara KN, Kotamraju VR, Ruoslahti E, Bydder GM, Mattrey RF, Magn Reson Med 2011 65 1649 1660 10.1002/mrm.22755 21305596
    • (2011) Magn Reson Med , vol.65 , pp. 1649-1660
    • Girard, O.M.1    Du, J.2    Agemy, L.3    Sugahara, K.N.4    Kotamraju, V.R.5    Ruoslahti, E.6    Bydder, G.M.7    Mattrey, R.F.8
  • 17
    • 84870064657 scopus 로고    scopus 로고
    • Early detection of lung inflammation: Exploiting T(1) -effects of iron oxide particles using UTE MRI
    • 10.1002/mrm.24180 22368111
    • Early detection of lung inflammation: Exploiting T(1) -effects of iron oxide particles using UTE MRI. Strobel K, Hoerr V, Schmid F, Wachsmuth L, Löffler B, Faber C, Magn Reson Med 2012 68 1924 1931 10.1002/mrm.24180 22368111
    • (2012) Magn Reson Med , vol.68 , pp. 1924-1931
    • Strobel, K.1    Hoerr, V.2    Schmid, F.3    Wachsmuth, L.4    Löffler, B.5    Faber, C.6
  • 18
    • 33644815711 scopus 로고    scopus 로고
    • Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T
    • DOI 10.1002/mrm.20815
    • Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T. Hiba B, Richard N, Janier M, Croisille P, Magn Reson Med 2006 55 506 513 10.1002/mrm.20815 16463350 (Pubitemid 43352548)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.3 , pp. 506-513
    • Hiba, B.1    Richard, N.2    Janier, M.3    Croisille, P.4
  • 19
    • 35048889393 scopus 로고    scopus 로고
    • Cardiac and respiratory self-gated cine MRI in the mouse: Comparison between radial and rectilinear techniques at 7T
    • DOI 10.1002/mrm.21355
    • Cardiac and respiratory self-gated cine MRI in the mouse: comparison between radial and rectilinear techniques at 7T. Hiba B, Richard N, Thibault H, Janier M, Magn Reson Med 2007 58 745 753 10.1002/mrm.21355 17899593 (Pubitemid 47556879)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.4 , pp. 745-753
    • Hiba, B.1    Richard, N.2    Thibault, H.3    Janier, M.4
  • 20
    • 33846029089 scopus 로고    scopus 로고
    • Doppler ultrasound in mice
    • DOI 10.1111/j.1540-8175.2006.00358.x
    • Doppler ultrasound in mice. Stypmann J, Echocardiography 2007 24 97 112 17214632 (Pubitemid 46044655)
    • (2007) Echocardiography , vol.24 , Issue.1 , pp. 97-112
    • Stypmann, J.1
  • 21
    • 63849269691 scopus 로고    scopus 로고
    • Echocardiographic assessment of global left ventricular function in mice
    • 10.1258/la.2007.06001e 19237453
    • Echocardiographic assessment of global left ventricular function in mice. Stypmann J, Engelen MA, Troatz C, Rothenburger M, Eckardt L, Tiemann K, Lab Anim 2009 43 127 137 10.1258/la.2007.06001e 19237453
    • (2009) Lab Anim , vol.43 , pp. 127-137
    • Stypmann, J.1    Engelen, M.A.2    Troatz, C.3    Rothenburger, M.4    Eckardt, L.5    Tiemann, K.6
  • 22
    • 0022187595 scopus 로고
    • Fast sinc function gridding algorithm for fourier inversion in computer tomography
    • A fast sinc function gridding algorithm for fourier inversion in computer tomography. O'Sullivan JD, IEEE Trans Med Imaging 1985 4 200 207 18243972 (Pubitemid 16539712)
    • (1985) IEEE Transactions on Medical Imaging , vol.MI-4 , Issue.4 , pp. 200-207
    • O'Sullivan, J.D.1
  • 24
    • 20744459613 scopus 로고    scopus 로고
    • Rapid gridding reconstruction with a minimal oversampling ratio
    • DOI 10.1109/TMI.2005.848376
    • Rapid gridding reconstruction with a minimal oversampling ratio. Beatty PJ, Nishimura DG, Pauly JM, IEEE Trans Med Imaging 2005 24 799 808 15959939 (Pubitemid 40850531)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.6 , pp. 799-808
    • Beatty, P.J.1    Nishimura, D.G.2    Pauly, J.M.3
  • 25
    • 84858708733 scopus 로고    scopus 로고
    • Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla
    • 10.1097/RLI.0b013e31823d3eb6 22373534
    • Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla. Fries P, Massmann A, Seidel R, Müller A, Stroeder J, Custodis F, Reil J, Schneider G, Buecker A, Invest Radiol 2012 47 259 266 10.1097/RLI.0b013e31823d3eb6 22373534
    • (2012) Invest Radiol , vol.47 , pp. 259-266
    • Fries, P.1    Massmann, A.2    Seidel, R.3    Müller, A.4    Stroeder, J.5    Custodis, F.6    Reil, J.7    Schneider, G.8    Buecker, A.9
  • 26
    • 84876793732 scopus 로고    scopus 로고
    • Qualitative and quantitative ultrashort-TE MRI of cortical bone
    • 10.1002/nbm.2906 23280581
    • Qualitative and quantitative ultrashort-TE MRI of cortical bone. Du J, Bydder GM, NMR Biomed 2013 26 489 506 10.1002/nbm.2906 23280581
    • (2013) NMR Biomed , vol.26 , pp. 489-506
    • Du, J.1    Bydder, G.M.2
  • 27
    • 77955110162 scopus 로고    scopus 로고
    • Consequences of T2 relaxation during half-pulse slice selection for ultrashort TE imaging
    • 20665804
    • Consequences of T2 relaxation during half-pulse slice selection for ultrashort TE imaging. Robson MD, Gatehouse PD, Magn Reson Med 2010 64 610 615 20665804
    • (2010) Magn Reson Med , vol.64 , pp. 610-615
    • Robson, M.D.1    Gatehouse, P.D.2
  • 29
    • 84872954864 scopus 로고    scopus 로고
    • Real-time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstruction
    • 10.1002/mrm.24276 22498911
    • Real-time MRI of speaking at a resolution of 33 ms: undersampled radial FLASH with nonlinear inverse reconstruction. Niebergall A, Zhang S, Kunay E, Keydana G, Job M, Uecker M, Frahm J, Magn Reson Med 2013 69 477 485 10.1002/mrm.24276 22498911
    • (2013) Magn Reson Med , vol.69 , pp. 477-485
    • Niebergall, A.1    Zhang, S.2    Kunay, E.3    Keydana, G.4    Job, M.5    Uecker, M.6    Frahm, J.7
  • 33
    • 33644824867 scopus 로고    scopus 로고
    • CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system
    • DOI 10.1080/10976640500451903, PII K021636618824
    • CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system. Tyler DJ, Lygate CA, Schneider JE, Cassidy PJ, Neubauer S, Clarke K, J Cardiovasc Magn Reson 2006 8 327 333 10.1080/10976640500451903 16669175 (Pubitemid 43355105)
    • (2006) Journal of Cardiovascular Magnetic Resonance , vol.8 , Issue.2 , pp. 327-333
    • Tyler, D.1    Lygate, C.2    Schneider, J.3    Cassidy, P.4    Neubauer, S.5    Clarke, K.6
  • 34
    • 33646456603 scopus 로고    scopus 로고
    • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T
    • 10.1002/mrm.20866 16596630
    • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T. Herold V, Mörchel P, Faber C, Rommel E, Haase A, Jakob PM, Magn Reson Med 2006 55 1058 1064 10.1002/mrm.20866 16596630
    • (2006) Magn Reson Med , vol.55 , pp. 1058-1064
    • Herold, V.1    Mörchel, P.2    Faber, C.3    Rommel, E.4    Haase, A.5    Jakob, P.M.6
  • 36
    • 67049136398 scopus 로고    scopus 로고
    • In vivo measurement of local aortic pulse-wave velocity in mice with MR microscopy at 17.6 Tesla
    • 10.1002/mrm.21957 19353665
    • In vivo measurement of local aortic pulse-wave velocity in mice with MR microscopy at 17.6 Tesla. Herold V, Parczyk M, Mörchel P, Ziener CH, Klug G, Bauer WR, Rommel E, Jakob PM, Magn Reson Med 2009 61 1293 1299 10.1002/mrm.21957 19353665
    • (2009) Magn Reson Med , vol.61 , pp. 1293-1299
    • Herold, V.1    Parczyk, M.2    Mörchel, P.3    Ziener, C.H.4    Klug, G.5    Bauer, W.R.6    Rommel, E.7    Jakob, P.M.8
  • 37
    • 79952779383 scopus 로고    scopus 로고
    • Regional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla
    • 10.1186/1532-429X-12-72 21134260
    • Regional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla. Parczyk M, Herold V, Klug G, Bauer WR, Rommel E, Jakob PM, J Cardiovasc Magn Reson 2010 12 72 80 10.1186/1532-429X-12-72 21134260
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 72-80
    • Parczyk, M.1    Herold, V.2    Klug, G.3    Bauer, W.R.4    Rommel, E.5    Jakob, P.M.6
  • 40
    • 50049111170 scopus 로고    scopus 로고
    • Cine-MRI versus two-dimensional echocardiography to measure in vivo left ventricular function in rat heart
    • 10.1002/nbm.1268 18457349
    • Cine-MRI versus two-dimensional echocardiography to measure in vivo left ventricular function in rat heart. Stuckey DJ, Carr CA, Tyler DJ, Clarke K, NMR Biomed 2008 21 765 772 10.1002/nbm.1268 18457349
    • (2008) NMR Biomed , vol.21 , pp. 765-772
    • Stuckey, D.J.1    Carr, C.A.2    Tyler, D.J.3    Clarke, K.4
  • 41
    • 46849083535 scopus 로고    scopus 로고
    • Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent
    • DOI 10.1002/mrm.21618
    • Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent. Bucholz E, Ghaghada K, Qi Y, Mukundan S, Johnson GA, Magn Reson Med 2008 60 111 118 10.1002/mrm.21618 18581419 (Pubitemid 351956615)
    • (2008) Magnetic Resonance in Medicine , vol.60 , Issue.1 , pp. 111-118
    • Bucholz, E.1    Ghaghada, K.2    Qi, Y.3    Mukundan, S.4    Johnson, G.A.5
  • 42
    • 77950605576 scopus 로고    scopus 로고
    • Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA
    • 10.1002/mrm.22259 20373399
    • Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA. Bucholz E, Ghaghada K, Qi Y, Mukundan S, Rockman HA, Johnson GA, Magn Reson Med 2010 63 979 987 10.1002/mrm.22259 20373399
    • (2010) Magn Reson Med , vol.63 , pp. 979-987
    • Bucholz, E.1    Ghaghada, K.2    Qi, Y.3    Mukundan, S.4    Rockman, H.A.5    Johnson, G.A.6
  • 43
    • 84874385962 scopus 로고    scopus 로고
    • High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function
    • 10.1002/mrm.24287 22517471
    • High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function. Coolen BF, Abdurrachim D, Motaal AG, Nicolay K, Prompers JJ, Strijkers GJ, Magn Reson Med 2013 69 648 656 10.1002/mrm.24287 22517471
    • (2013) Magn Reson Med , vol.69 , pp. 648-656
    • Coolen, B.F.1    Abdurrachim, D.2    Motaal, A.G.3    Nicolay, K.4    Prompers, J.J.5    Strijkers, G.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.