메뉴 건너뛰기




Volumn 23, Issue 8, 2010, Pages 986-994

Real-time MRI at a resolution of 20 ms

Author keywords

Cardiovascular MRI; Dynamic imaging; Heart function; Movie; MRI; Real time; Speech production; Turbulent flow

Indexed keywords

CARDIOVASCULAR MRI; DYNAMIC IMAGING; HEART FUNCTION; MOVIE; MRI; REAL TIME; SPEECH PRODUCTION;

EID: 78651498681     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1585     Document Type: Article
Times cited : (350)

References (29)
  • 1
    • 33746803555 scopus 로고
    • Image formation by induced local interactions: examples employing nuclear magnetic resonance
    • Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature, 1973; 242: 190-191.
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 3
    • 0022592172 scopus 로고
    • Rapid NMR imaging of dynamic processes using the FLASH technique
    • Frahm J, Haase A, Matthaei D. Rapid NMR imaging of dynamic processes using the FLASH technique. Magn. Reson. Med. 1986; 3: 321-327.
    • (1986) Magn. Reson. Med. , vol.3 , pp. 321-327
    • Frahm, J.1    Haase, A.2    Matthaei, D.3
  • 4
    • 49349125543 scopus 로고
    • Biological and medical imaging by NMR
    • Mansfield P, Pykett IL. Biological and medical imaging by NMR. J. Magn. Reson. 1978; 29: 355-373.
    • (1978) J. Magn. Reson. , vol.29 , pp. 355-373
    • Mansfield, P.1    Pykett, I.L.2
  • 6
    • 0021340804 scopus 로고
    • Real-time echo-planar imaging by NMR
    • Mansfield P. Real-time echo-planar imaging by NMR. Br. Med. Bull. 1984; 40: 187-190.
    • (1984) Br. Med. Bull. , vol.40 , pp. 187-190
    • Mansfield, P.1
  • 9
    • 0022872540 scopus 로고
    • RARE imaging. A fast imaging method for clinical MRI
    • Hennig J, Nauerth A, Friedburg H. RARE imaging. A fast imaging method for clinical MRI. Magn. Reson. Med. 1986; 3: 823-833.
    • (1986) Magn. Reson. Med. , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 12
    • 74049110413 scopus 로고    scopus 로고
    • Magnetic resonance imaging in real time: advances using radial FLASH
    • Zhang S, Block KT, Frahm J. Magnetic resonance imaging in real time: advances using radial FLASH. J. Magn. Reson. Imaging, 2010; 31: 101-109.
    • (2010) J. Magn. Reson. Imaging , vol.31 , pp. 101-109
    • Zhang, S.1    Block, K.T.2    Frahm, J.3
  • 14
    • 51449090553 scopus 로고    scopus 로고
    • Image reconstruction by regularized nonlinear inversion - joint estimation of coil sensitivities and image content
    • Uecker M, Hohage T, Block KT, Frahm J. Image reconstruction by regularized nonlinear inversion - joint estimation of coil sensitivities and image content. Magn. Reson. Med. 2008; 60: 674-682.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 674-682
    • Uecker, M.1    Hohage, T.2    Block, K.T.3    Frahm, J.4
  • 15
    • 77952692860 scopus 로고    scopus 로고
    • Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH
    • Uecker M, Zhang S, Frahm J. Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH. Magn. Reson. Med. 2010; 63: 1456-1462.
    • (2010) Magn. Reson. Med. , vol.63 , pp. 1456-1462
    • Uecker, M.1    Zhang, S.2    Frahm, J.3
  • 16
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn. Reson. Med. 2007; 57: 1086-1098.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 17
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in computer tomography
    • O'Sullivan JD. A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans. Med. Imaging, 1985; 4: 200-207.
    • (1985) IEEE Trans. Med. Imaging , vol.4 , pp. 200-207
    • O'Sullivan, J.D.1
  • 18
    • 0015984922 scopus 로고
    • 0-SINH window function., Proceedings of the IEEE International Symposium on Circuits and Systems San Francisco, CA, USA.
    • 0-SINH window function. Proceedings of the IEEE International Symposium on Circuits and Systems San Francisco, CA, USA, 1974; 20-23.
    • (1974) , pp. 20-23
    • Kaiser, J.F.1
  • 19
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • Jackson JI, Meyer CG, Nishimura DG. Selection of a convolution function for Fourier inversion using gridding. IEEE Trans. Med. Imaging, 1991; 10: 473-478.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 473-478
    • Jackson, J.I.1    Meyer, C.G.2    Nishimura, D.G.3
  • 20
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 1997; 38: 591-603.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 22
    • 28544444551 scopus 로고    scopus 로고
    • Iterative Methods for Approximate Solution of Inverse Problems
    • Springer: Dordrecht.
    • Bakushinsky AB, Kokurin MYu. Iterative Methods for Approximate Solution of Inverse Problems. Springer: Dordrecht, 2004.
    • (2004)
    • Bakushinsky, A.B.1    Kokurin, M.Y.2
  • 23
    • 78651517963 scopus 로고    scopus 로고
    • Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories. Proceedings of the 9th Annual Meeting ISMRM Glasgow, UK
    • Wajer F, Pruessmann KP. Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories. Proceedings of the 9th Annual Meeting ISMRM Glasgow, UK 2001; 767.
    • (2001) , pp. 767
    • Wajer, F.1    Pruessmann, K.P.2
  • 25
    • 0003854151 scopus 로고
    • Exploratory Data Analysis
    • Addison-Wesley: Reading, MA.
    • Tukey JW. Exploratory Data Analysis. Addison-Wesley: Reading, MA, 1977.
    • (1977)
    • Tukey, J.W.1
  • 26
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: the application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn. Reson. Med. 2007; 58: 1182-1195.
    • (2007) Magn. Reson. Med. , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 28
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn. Reson. Med. 1999; 42: 813-828.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 29
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn. Reson. Med. 2001; 45: 846-852.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.