메뉴 건너뛰기




Volumn 8, Issue 6, 2013, Pages

Complications of Absorbable Fixation in Maxillofacial Surgery: A Meta-Analysis

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM;

EID: 84879511054     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0067449     Document Type: Article
Times cited : (38)

References (36)
  • 1
    • 84856933394 scopus 로고    scopus 로고
    • A randomized clinical trial of biodegradable and titanium fixation systems in maxillofacial surgery
    • Buijs GJ, van BNB, Jansma J, de Visscher JG, Hoppenreijs TJ, et al. (2012) A randomized clinical trial of biodegradable and titanium fixation systems in maxillofacial surgery. J Dent Res 91: 299-304.
    • (2012) J Dent Res , vol.91 , pp. 299-304
    • Buijs, G.J.1    van, B.N.B.2    Jansma, J.3    de Visscher, J.G.4    Hoppenreijs, T.J.5
  • 2
    • 0031780545 scopus 로고    scopus 로고
    • Biodegradable polylactide plates and screws in orthognathic surgery: technical note
    • Haers PE, Suuronen R, Lindqvist C, Sailer H, (1998) Biodegradable polylactide plates and screws in orthognathic surgery: technical note. J Craniomaxillofac Surg 26: 87-91.
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 87-91
    • Haers, P.E.1    Suuronen, R.2    Lindqvist, C.3    Sailer, H.4
  • 3
    • 0032971146 scopus 로고    scopus 로고
    • Metallic fragments on the surface of miniplates and screws before insertion
    • Ray MS, Matthew IR, Frame JW, (1999) Metallic fragments on the surface of miniplates and screws before insertion. Br J Oral Maxillofac Surg 37: 14-18.
    • (1999) Br J Oral Maxillofac Surg , vol.37 , pp. 14-18
    • Ray, M.S.1    Matthew, I.R.2    Frame, J.W.3
  • 4
    • 84873297729 scopus 로고    scopus 로고
    • Titanium miniplates: a new risk factor for the development of the bisphosphonate-related osteonecrosis of the jaw
    • Siniscalchi EN, Catalfamo L, Allegra A, Musolino C, De Ponte FS, (2013) Titanium miniplates: a new risk factor for the development of the bisphosphonate-related osteonecrosis of the jaw. J Craniofac Surg 24: e1-2.
    • (2013) J Craniofac Surg , vol.24
    • Siniscalchi, E.N.1    Catalfamo, L.2    Allegra, A.3    Musolino, C.4    De Ponte, F.S.5
  • 5
    • 84863984999 scopus 로고    scopus 로고
    • Maxillary stability after Le Fort I osteotomy using three different plate systems
    • Ueki K, Okabe K, Moroi A, Marukawa K, Sotobori M, et al. (2012) Maxillary stability after Le Fort I osteotomy using three different plate systems. Int J Oral Maxillofac Surg 41: 942-948.
    • (2012) Int J Oral Maxillofac Surg , vol.41 , pp. 942-948
    • Ueki, K.1    Okabe, K.2    Moroi, A.3    Marukawa, K.4    Sotobori, M.5
  • 7
  • 8
    • 84859109530 scopus 로고    scopus 로고
    • Comparison of material-related complications after bilateral sagittal split mandibular setback surgery: biodegradable versus titanium miniplates
    • Yoshioka I, Igawa K, Nagata J, Yoshida M, Ogawa Y, et al. (2012) Comparison of material-related complications after bilateral sagittal split mandibular setback surgery: biodegradable versus titanium miniplates. J Oral Maxillofac Surg 70: 919-924.
    • (2012) J Oral Maxillofac Surg , vol.70 , pp. 919-924
    • Yoshioka, I.1    Igawa, K.2    Nagata, J.3    Yoshida, M.4    Ogawa, Y.5
  • 10
    • 0029889927 scopus 로고    scopus 로고
    • Assessing the quality of randomized controlled trials. Current issues and future directions
    • Moher D, Jadad AR, Tugwell P, (1996) Assessing the quality of randomized controlled trials. Current issues and future directions. Int J Technol Assess Health Care 12: 195-208.
    • (1996) Int J Technol Assess Health Care , vol.12 , pp. 195-208
    • Moher, D.1    Jadad, A.R.2    Tugwell, P.3
  • 11
    • 34948873116 scopus 로고    scopus 로고
    • Segment stability in bimaxillary orthognathic surgery after resorbable Poly(L-lactide-co-glycolide) versus titanium osteosyntheses
    • Landes CA, Ballon A, Sader R, (2007) Segment stability in bimaxillary orthognathic surgery after resorbable Poly(L-lactide-co-glycolide) versus titanium osteosyntheses. J Craniofac Surg 18: 1216-1229.
    • (2007) J Craniofac Surg , vol.18 , pp. 1216-1229
    • Landes, C.A.1    Ballon, A.2    Sader, R.3
  • 12
    • 33748285625 scopus 로고    scopus 로고
    • Skeletal stability in bimaxillary orthognathic surgery: P(L/DL)LA-resorbable versus titanium osteofixation
    • discussion 722
    • Landes CA, Ballon A (2006) Skeletal stability in bimaxillary orthognathic surgery: P(L/DL)LA-resorbable versus titanium osteofixation. Plast Reconstr Surg 118: 703-721; discussion 722.
    • (2006) Plast Reconstr Surg , vol.118 , pp. 703-721
    • Landes, C.A.1    Ballon, A.2
  • 13
    • 33645062147 scopus 로고    scopus 로고
    • Stability of skeletal Class III malocclusion after combined maxillary and mandibular procedures: titanium versus resorbable plates and screws for maxillary fixation
    • Costa F, Robiony M, Zorzan E, Zerman N, Politi M, (2006) Stability of skeletal Class III malocclusion after combined maxillary and mandibular procedures: titanium versus resorbable plates and screws for maxillary fixation. J Oral Maxillofac Surg 64: 642-651.
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 642-651
    • Costa, F.1    Robiony, M.2    Zorzan, E.3    Zerman, N.4    Politi, M.5
  • 14
    • 21844468496 scopus 로고    scopus 로고
    • Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-L-lactic acid or titanium plate fixation
    • Ueki K, Nakagawa K, Marukawa K, Takazakura D, Shimada M, et al. (2005) Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-L-lactic acid or titanium plate fixation. Int J Oral Maxillofac Surg 34: 627-634.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 627-634
    • Ueki, K.1    Nakagawa, K.2    Marukawa, K.3    Takazakura, D.4    Shimada, M.5
  • 15
    • 77956697540 scopus 로고    scopus 로고
    • Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible - the results of a two centre randomised clinical study with an eight-year follow-up
    • Stockmann P, Bohm H, Driemel O, Muhling J, Pistner H, (2010) Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible- the results of a two centre randomised clinical study with an eight-year follow-up. J Craniomaxillofac Surg 38: 522-528.
    • (2010) J Craniomaxillofac Surg , vol.38 , pp. 522-528
    • Stockmann, P.1    Bohm, H.2    Driemel, O.3    Muhling, J.4    Pistner, H.5
  • 16
    • 29144504069 scopus 로고    scopus 로고
    • Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement
    • Turvey TA, Bell RB, Phillips C, Proffit WR, (2006) Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement. J Oral Maxillofac Surg 64: 40-46.
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 40-46
    • Turvey, T.A.1    Bell, R.B.2    Phillips, C.3    Proffit, W.R.4
  • 17
    • 84869495070 scopus 로고    scopus 로고
    • Comparative study of skeletal stability between bicortical resorbable and titanium screw fixation after sagittal split ramus osteotomy for mandibular prognathism
    • Paeng JY, Hong J, Kim CS, Kim MJ, (2012) Comparative study of skeletal stability between bicortical resorbable and titanium screw fixation after sagittal split ramus osteotomy for mandibular prognathism. J Craniomaxillofac Surg 40: 660-664.
    • (2012) J Craniomaxillofac Surg , vol.40 , pp. 660-664
    • Paeng, J.Y.1    Hong, J.2    Kim, C.S.3    Kim, M.J.4
  • 18
    • 0038785582 scopus 로고    scopus 로고
    • Preliminary assessment of skeletal stability after sagittal split mandibular advancement using a bioresorbable fixation system
    • Matthews NS, Khambay BS, Ayoub AF, Koppel D, Wood G, (2003) Preliminary assessment of skeletal stability after sagittal split mandibular advancement using a bioresorbable fixation system. Br J Oral Maxillofac Surg 41: 179-184.
    • (2003) Br J Oral Maxillofac Surg , vol.41 , pp. 179-184
    • Matthews, N.S.1    Khambay, B.S.2    Ayoub, A.F.3    Koppel, D.4    Wood, G.5
  • 19
    • 2342536354 scopus 로고    scopus 로고
    • Le Fort I miniplate osteosynthesis: a randomized, prospective study comparing resorbable PLLA/PGA with titanium
    • Norholt SE, Pedersen TK, Jensen J, (2004) Le Fort I miniplate osteosynthesis: a randomized, prospective study comparing resorbable PLLA/PGA with titanium. Int J Oral Maxillofac Surg 33: 245-252.
    • (2004) Int J Oral Maxillofac Surg , vol.33 , pp. 245-252
    • Norholt, S.E.1    Pedersen, T.K.2    Jensen, J.3
  • 20
    • 32044449026 scopus 로고    scopus 로고
    • Five-year experience comparing resorbable to titanium miniplate osteosynthesis in cleft lip and palate orthognathic surgery
    • Landes CA, Ballon A, (2006) Five-year experience comparing resorbable to titanium miniplate osteosynthesis in cleft lip and palate orthognathic surgery. Cleft Palate Craniofac J 43: 67-74.
    • (2006) Cleft Palate Craniofac J , vol.43 , pp. 67-74
    • Landes, C.A.1    Ballon, A.2
  • 21
    • 77956627022 scopus 로고    scopus 로고
    • Comparison of titanium and biodegradable miniplates for fixation of mandibular fractures
    • Lee HB, Oh JS, Kim SG, Kim HK, Moon SY, et al. (2010) Comparison of titanium and biodegradable miniplates for fixation of mandibular fractures. J Oral Maxillofac Surg 68: 2065-2069.
    • (2010) J Oral Maxillofac Surg , vol.68 , pp. 2065-2069
    • Lee, H.B.1    Oh, J.S.2    Kim, S.G.3    Kim, H.K.4    Moon, S.Y.5
  • 22
    • 77955660533 scopus 로고    scopus 로고
    • Equivalence randomized controlled trial of bioresorbable versus titanium miniplates in treatment of mandibular fracture: a pilot study
    • Bhatt K, Roychoudhury A, Bhutia O, Trikha A, Seith A, et al. (2010) Equivalence randomized controlled trial of bioresorbable versus titanium miniplates in treatment of mandibular fracture: a pilot study. J Oral Maxillofac Surg 68: 1842-1848.
    • (2010) J Oral Maxillofac Surg , vol.68 , pp. 1842-1848
    • Bhatt, K.1    Roychoudhury, A.2    Bhutia, O.3    Trikha, A.4    Seith, A.5
  • 23
    • 55249096242 scopus 로고    scopus 로고
    • INION compared with titanium osteosynthesis: a prospective investigation of the treatment of mandibular fractures
    • Leonhardt H, Demmrich A, Mueller A, Mai R, Loukota R, et al. (2008) INION compared with titanium osteosynthesis: a prospective investigation of the treatment of mandibular fractures. Br J Oral Maxillofac Surg 46: 631-634.
    • (2008) Br J Oral Maxillofac Surg , vol.46 , pp. 631-634
    • Leonhardt, H.1    Demmrich, A.2    Mueller, A.3    Mai, R.4    Loukota, R.5
  • 24
    • 33644976252 scopus 로고    scopus 로고
    • Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis
    • Wittwer G, Adeyemo WL, Yerit K, Voracek M, Turhani D, et al. (2006) Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101: 419-425.
    • (2006) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.101 , pp. 419-425
    • Wittwer, G.1    Adeyemo, W.L.2    Yerit, K.3    Voracek, M.4    Turhani, D.5
  • 25
    • 36148954262 scopus 로고    scopus 로고
    • Evaluation of Bioresorbable vis-à-vis Titanium Plates and Screws for Craniofacial Fractures and Osteotomies
    • Menon S, Chowdhury S, (2007) Evaluation of Bioresorbable vis-à-vis Titanium Plates and Screws for Craniofacial Fractures and Osteotomies. MJAFI 63: 331-333.
    • (2007) MJAFI , vol.63 , pp. 331-333
    • Menon, S.1    Chowdhury, S.2
  • 26
    • 5144224366 scopus 로고    scopus 로고
    • A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery
    • Cheung LK, Chow LK, Chiu WK, (2004) A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 98: 386-397.
    • (2004) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.98 , pp. 386-397
    • Cheung, L.K.1    Chow, L.K.2    Chiu, W.K.3
  • 27
    • 73949154010 scopus 로고    scopus 로고
    • Comparative study between resorbable and nonresorbable plates in orthognathic surgery
    • Ahn YS, Kim SG, Baik SM, Kim BO, Kim HK, et al. (2010) Comparative study between resorbable and nonresorbable plates in orthognathic surgery. J Oral Maxillofac Surg 68: 287-292.
    • (2010) J Oral Maxillofac Surg , vol.68 , pp. 287-292
    • Ahn, Y.S.1    Kim, S.G.2    Baik, S.M.3    Kim, B.O.4    Kim, H.K.5
  • 28
    • 78049313110 scopus 로고    scopus 로고
    • Comparison of the stability of bioabsorbable and titanium osteosynthesis materials for rigid internal fixation in orthognathic surgery. A prospective randomized controlled study in 101 patients with 192 osteotomies
    • Tuovinen V, Suuronen R, Teittinen M, Nurmenniemi P, (2010) Comparison of the stability of bioabsorbable and titanium osteosynthesis materials for rigid internal fixation in orthognathic surgery. A prospective randomized controlled study in 101 patients with 192 osteotomies. Int J Oral Maxillofac Surg 39: 1059-1065.
    • (2010) Int J Oral Maxillofac Surg , vol.39 , pp. 1059-1065
    • Tuovinen, V.1    Suuronen, R.2    Teittinen, M.3    Nurmenniemi, P.4
  • 30
    • 36048974479 scopus 로고    scopus 로고
    • Incidence of complications and problems related to orthognathic surgery
    • Kim SG, Park SS, (2007) Incidence of complications and problems related to orthognathic surgery. J Oral Maxillofac Surg 65: 2438-2444.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 2438-2444
    • Kim, S.G.1    Park, S.S.2
  • 31
    • 33845394842 scopus 로고    scopus 로고
    • Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity
    • Lee JG, Kim SG, Lim KJ, Choi KC, (2007) Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity. J Oral Maxillofac Surg 65: 74-78.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 74-78
    • Lee, J.G.1    Kim, S.G.2    Lim, K.J.3    Choi, K.C.4
  • 32
    • 64149086673 scopus 로고    scopus 로고
    • Evaluation of bone formation after sagittal split ramus osteotomy with bent plate fixation using computed tomography
    • Ueki K, Hashiba Y, Marukawa K, Okabe K, Nakagawa K, et al. (2009) Evaluation of bone formation after sagittal split ramus osteotomy with bent plate fixation using computed tomography. J Oral Maxillofac Surg 67: 1062-1068.
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 1062-1068
    • Ueki, K.1    Hashiba, Y.2    Marukawa, K.3    Okabe, K.4    Nakagawa, K.5
  • 33
    • 0026518970 scopus 로고
    • Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
    • Bostman OM (1992) Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res: 193-199.
    • (1992) Clin Orthop Relat Res , pp. 193-199
    • Bostman, O.M.1
  • 34
    • 0023205611 scopus 로고
    • Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
    • Bos RR, Boering G, Rozema FR, Leenslag JW, (1987) Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures. J Oral Maxillofac Surg 45: 751-753.
    • (1987) J Oral Maxillofac Surg , vol.45 , pp. 751-753
    • Bos, R.R.1    Boering, G.2    Rozema, F.R.3    Leenslag, J.W.4
  • 35
    • 46449100337 scopus 로고    scopus 로고
    • Comparison of titanium and resorbable copolymer fixation after Le Fort I maxillary impaction
    • Dhol WS, Reyneke JP, Tompson B, Sandor GK, (2008) Comparison of titanium and resorbable copolymer fixation after Le Fort I maxillary impaction. Am J Orthod Dentofacial Orthop 134: 67-73.
    • (2008) Am J Orthod Dentofacial Orthop , vol.134 , pp. 67-73
    • Dhol, W.S.1    Reyneke, J.P.2    Tompson, B.3    Sandor, G.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.