-
1
-
-
0030954702
-
A bioresorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery
-
Bessho K. T. Iizuka K. Murakami A bioresorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery J. Oral. Maxillofac. Surg. 55 1997 941 945
-
(1997)
J. Oral. Maxillofac. Surg.
, vol.55
, pp. 941-945
-
-
Bessho, K.1
Iizuka, T.2
Murakami, K.3
-
4
-
-
0015076420
-
Fracture reduction using a biodegradable material, polylactic acid
-
Cutright D.E. E.E. Hunsuck J.D. Beasley Fracture reduction using a biodegradable material, polylactic acid J. Oral Surg. 29 1971 393 397
-
(1971)
J. Oral Surg.
, vol.29
, pp. 393-397
-
-
Cutright, D.E.1
Hunsuck, E.E.2
Beasley, J.D.3
-
5
-
-
0027225920
-
In-vivo and clinical evaluations of Poly(L-lactide) plates and screws for use in maxillofacial traumatology
-
Gerlach K.L. In-vivo and clinical evaluations of Poly(L-lactide) plates and screws for use in maxillofacial traumatology Clin. Mater. 13 1993 21 28
-
(1993)
Clin. Mater.
, vol.13
, pp. 21-28
-
-
Gerlach, K.L.1
-
6
-
-
85119811077
-
Kieferorthopädisch-chirurgische Korrekturen von Dysgnathien
-
Haers P.E. H.F. Sailer Kieferorthopädisch-chirurgische Korrekturen von Dysgnathien Denecke Reichart Muhr Saegesser: Spezielle chirurgische Therapie, 11. Auflage 1996 Hans Huber Stuttgart 21 40
-
(1996)
, pp. 21-40
-
-
Haers, P.E.1
Sailer, H.F.2
-
7
-
-
0026514596
-
Rigid internal fixation of mandibular fractures. An analysis of 270 fractures using the AO/ASIF method
-
Iizuka T. C. Lindqvist Rigid internal fixation of mandibular fractures. An analysis of 270 fractures using the AO/ASIF method Int. J. Oral Maxillofac. Surg. 21 1992 65 69
-
(1992)
Int. J. Oral Maxillofac. Surg.
, vol.21
, pp. 65-69
-
-
Iizuka, T.1
Lindqvist, C.2
-
8
-
-
0025784377
-
Resorbable implants in craniofacial surgery in childhood. A contribution to the development of poly(lactide) implants
-
Illi O.E. U.G. Stauffer H.F. Sailer H. Weigum Resorbable implants in craniofacial surgery in childhood. A contribution to the development of poly(lactide) implants Helv. Chir. Acta 58 1991 123 127
-
(1991)
Helv. Chir. Acta
, vol.58
, pp. 123-127
-
-
Illi, O.E.1
Stauffer, U.G.2
Sailer, H.F.3
Weigum, H.4
-
12
-
-
0030991038
-
Tissue response to titanium plates: a transmitted electron microscopic study
-
Kim Y.K. H.M. Yeo Hh S.C. Lim Tissue response to titanium plates: a transmitted electron microscopic study J. Oral Maxillofac. Surg. 55 1997 322 326
-
(1997)
J. Oral Maxillofac. Surg.
, vol.55
, pp. 322-326
-
-
Kim, Y.K.1
Yeo Hh, H.M.2
Lim, S.C.3
-
14
-
-
0021842535
-
Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle
-
Rokkanen P. O. Bostman S. Vainionpaa K. Vithonen P. Tormala J. Laiho J. Laiho J. Kilpikari M. Tamminmaki Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle Lancet. 1 8443 1985 1422 1424
-
(1985)
Lancet.
, vol.1
, Issue.8443
, pp. 1422-1424
-
-
Rokkanen, P.1
Bostman, O.2
Vainionpaa, S.3
Vithonen, K.4
Tormala, P.5
Laiho, J.6
Laiho, J.7
Kilpikari, J.8
Tamminmaki, M.9
-
16
-
-
0027417781
-
Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment
-
Schliephake H. H. Lehmann U. Kunz R. Schmelzeisen Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment Int. J. Oral Maxillofac. Surg. 22 1993 20 25
-
(1993)
Int. J. Oral Maxillofac. Surg.
, vol.22
, pp. 20-25
-
-
Schliephake, H.1
Lehmann, H.2
Kunz, U.3
Schmelzeisen, R.4
-
17
-
-
0025941602
-
Comparison of absorbable self-reinforced poly-1-lactide screws and metallic screws in the fixation of mandibular condyle osteotomies. Experimental study in sheep
-
Suuronen R. Comparison of absorbable self-reinforced poly-1-lactide screws and metallic screws in the fixation of mandibular condyle osteotomies. Experimental study in sheep J. Oral Maxillofac. Surg. 49 1991
-
(1991)
J. Oral Maxillofac. Surg.
, vol.49
-
-
Suuronen, R.1
-
18
-
-
0026516277
-
New generation biodegradable plate for fracture fixation. Comparison of bending strengths of mandibular osteotomies fixed with absorbable self-reinforced multi-layer poly-1-lactide plates and metallic plates. An experimental study in sheep
-
Suuronen R. T. Pohjonen L. Wessman P. Törmälä S. Vainionpää New generation biodegradable plate for fracture fixation. Comparison of bending strengths of mandibular osteotomies fixed with absorbable self-reinforced multi-layer poly-1-lactide plates and metallic plates. An experimental study in sheep Clin. Mater. 9 1992 77 84
-
(1992)
Clin. Mater.
, vol.9
, pp. 77-84
-
-
Suuronen, R.1
Pohjonen, T.2
Wessman, L.3
Törmälä, P.4
Vainionpää, S.5
-
19
-
-
0042878289
-
Comparison of shear strength of osteotomies fixed with absorbable self-reinforced poly-1-lactide and metallic screws
-
Suuronen R. P. Törmälä J. Vasenius L. Wessman M. Mero E. Partio K. Vihtonen S. Vainionpää Comparison of shear strength of osteotomies fixed with absorbable self-reinforced poly-1-lactide and metallic screws J. Mater. Sci. Materials in Medicine 3 1992 288 292
-
(1992)
J. Mater. Sci. Materials in Medicine
, vol.3
, pp. 288-292
-
-
Suuronen, R.1
Törmälä, P.2
Vasenius, J.3
Wessman, L.4
Mero, M.5
Partio, E.6
Vihtonen, K.7
Vainionpää, S.8
-
20
-
-
0026556049
-
Comparison of absorbable self-reinforced multi-layer poly-1-lactide and metallic plates in the fixation of mandibular body osteotomies: An experimental study in sheep
-
Suuronen R. T. Pohjonen J. Vasenius S. Vainionpää Comparison of absorbable self-reinforced multi-layer poly-1-lactide and metallic plates in the fixation of mandibular body osteotomies: An experimental study in sheep J. Oral Maxillofac. Surg. 50 1992 255 262
-
(1992)
J. Oral Maxillofac. Surg.
, vol.50
, pp. 255-262
-
-
Suuronen, R.1
Pohjonen, T.2
Vasenius, J.3
Vainionpää, S.4
-
21
-
-
0026676926
-
Sagittal split osteotomy fixed with biodegradable, self-reinforced poly-1-lactide screws. A pilot study in sheep
-
Suuronen R. P. Laine E. Sarkiala T. Pohjonen C. Lindqvist Sagittal split osteotomy fixed with biodegradable, self-reinforced poly-1-lactide screws. A pilot study in sheep Int. J. Oral Maxillofac. Surg. 21 1992 303 308
-
(1992)
Int. J. Oral Maxillofac. Surg.
, vol.21
, pp. 303-308
-
-
Suuronen, R.1
Laine, P.2
Sarkiala, E.3
Pohjonen, T.4
Lindqvist, C.5
-
22
-
-
0028343026
-
Sagittal osteotomies fixed with biodegradable screws: A preliminary report
-
Suuronen R. P. Laine C. Lindqvist Sagittal osteotomies fixed with biodegradable screws: A preliminary report J. Oral Maxillofacial. Surg. 52 1994 715 720
-
(1994)
J. Oral Maxillofacial. Surg.
, vol.52
, pp. 715-720
-
-
Suuronen, R.1
Laine, P.2
Lindqvist, C.3
-
24
-
-
0642366427
-
Ultrahigh-strength self-reinforced polylactide composites and their surgical applications
-
Tormala P. T. Pohjonen P. Rokkanen Ultrahigh-strength self-reinforced polylactide composites and their surgical applications Macromol. Symp. 123 1997 123 131
-
(1997)
, pp. 123-131
-
-
Tormala, P.1
Pohjonen, T.2
Rokkanen, P.3
-
25
-
-
0030958962
-
Resorbable fixation in head and neck surgery
-
Weissberger E.C. B.L. Eppley Resorbable fixation in head and neck surgery Laryngoscope 107 1997 716 719
-
(1997)
Laryngoscope
, vol.107
, pp. 716-719
-
-
Weissberger, E.C.1
Eppley, B.L.2
|