메뉴 건너뛰기




Volumn 63, Issue 4, 2007, Pages 331-333

Evaluation of bioresorbable vis-à-vis titanium plates and screws for craniofacial fractures and osteotomies

Author keywords

Osteosynthesis; Resorbable system; Zygomatic complex

Indexed keywords

POLYMER; TITANIUM;

EID: 36148954262     PISSN: 03771237     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0377-1237(07)80008-6     Document Type: Article
Times cited : (9)

References (6)
  • 1
    • 0031949295 scopus 로고    scopus 로고
    • A five year in vitro and in vivo study of the biodegradation of Polylactide plates
    • Riitta S, et al. A five year in vitro and in vivo study of the biodegradation of Polylactide plates. J Oral Maxillofac Surg 1998:56; 604-14.
    • (1998) J Oral Maxillofac Surg , vol.56 , pp. 604-614
    • Riitta, S.1
  • 2
    • 0030991038 scopus 로고    scopus 로고
    • Tissue response to titanium plates: A transmitted electron microscopic study
    • Kim YK, Yeo HH, Um SC. Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg 1997;55:322-6.
    • (1997) J Oral Maxillofac Surg , vol.55 , pp. 322-326
    • Kim, Y.K.1    Yeo, H.H.2    Um, S.C.3
  • 3
    • 0035378622 scopus 로고    scopus 로고
    • Dynamic study about metal release from titanium miniplates in maxillofacial surgery
    • Meningaud JP, et al. Dynamic study about metal release from titanium miniplates in maxillofacial surgery. Int J Oral Maxillofac Surg 2001: 30; 185-8.
    • (2001) Int J Oral Maxillofac Surg , vol.30 , pp. 185-188
    • Meningaud, J.P.1
  • 4
    • 0013965320 scopus 로고
    • Poly lactic acid for surgical implant
    • Kulkarni RK, Pani KC, Neuman C, et al. Poly lactic acid for surgical implant. Arch Surg 1966: 93; 839.
    • (1966) Arch Surg , vol.93 , pp. 839
    • Kulkarni, R.K.1    Pani, K.C.2    Neuman, C.3
  • 5
    • 0035165602 scopus 로고    scopus 로고
    • The fate of Poly-L-Lactic/ polyglycolic acid(Lactosorb) bone fixation devices in orthognathic surgery
    • Edwards RC, Kiely KD, Eppley BL. The fate of Poly-L-Lactic/ polyglycolic acid(Lactosorb) bone fixation devices in orthognathic surgery. JOMS 2001: 59; 19-25.
    • (2001) JOMS , vol.59 , pp. 19-25
    • Edwards, R.C.1    Kiely, K.D.2    Eppley, B.L.3
  • 6
    • 0030954702 scopus 로고    scopus 로고
    • A bioresorbable Poly-L-Lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery
    • Kazuhisa B, Tadahiko I, Ken-ichiro M. A bioresorbable Poly-L-Lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery. J Oral maxillofac Surg 1997:55; 941-5.
    • (1997) J Oral maxillofac Surg , vol.55 , pp. 941-945
    • Kazuhisa, B.1    Tadahiko, I.2    Ken-ichiro, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.