-
1
-
-
0028221284
-
Osteosynthesis using biodegradable Poly-p-dioxanon (PDS II) in Le Fort I - Osteotomy without postoperative intermaxillary fixation
-
DOI 10.1016/S1010-5182(05)80377-4
-
J.A. Obwegeser Osteosynthesis using biodegradable Poly-p-dioxanon (PDS II) in Le Fort I osteotomy without postoperative intermaxillary fixation J Craniomaxillofac Surg 22 1994 129 137 (Pubitemid 24171199)
-
(1994)
Journal of Cranio-Maxillo-Facial Surgery
, vol.22
, Issue.3
, pp. 129-137
-
-
Obwegeser, J.A.1
-
2
-
-
0031005670
-
Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-l-lactic acid (PLLA) screws
-
K. Harada, and S. Enomoto Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-l-lactic acid (PLLA) screws J Oral Maxillofac Surg 55 1997 464 468
-
(1997)
J Oral Maxillofac Surg
, vol.55
, pp. 464-468
-
-
Harada, K.1
Enomoto, S.2
-
3
-
-
64149086673
-
Evaluation of bone formation after sagittal split ramus osteotomy with bent plate fixation using computed tomography
-
K. Ueki, Y. Hashiba, K. Marukawa, K. Okabe, K. Nakagawa, and S. Alam Evaluation of bone formation after sagittal split ramus osteotomy with bent plate fixation using computed tomography J Oral Maxillofac Surg 67 2009 1062 1068
-
(2009)
J Oral Maxillofac Surg
, vol.67
, pp. 1062-1068
-
-
Ueki, K.1
Hashiba, Y.2
Marukawa, K.3
Okabe, K.4
Nakagawa, K.5
Alam, S.6
-
4
-
-
21844468496
-
Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-l-lactic acid or titanium plate fixation
-
DOI 10.1016/j.ijom.2005.02.013, PII S0901502705000846
-
K. Ueki, K. Nakagawa, K. Marukawa, D. Takazakura, M. Shimada, and S. Takatsuka Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-l-lactic acid or titanium plate fixation Int J Oral Maxillofac Surg 34 2005 627 634 (Pubitemid 40960074)
-
(2005)
International Journal of Oral and Maxillofacial Surgery
, vol.34
, Issue.6
, pp. 627-634
-
-
Ueki, K.1
Nakagawa, K.2
Marukawa, K.3
Takazakura, D.4
Shimada, M.5
Takatsuka, S.6
Yamamoto, E.7
-
5
-
-
29144449965
-
Maxillary stability following le Fort i osteotomy in combination with sagittal split ramus osteotomy and intraoral vertical ramus osteotomy: A comparative study between titanium miniplate and poly-l-lactic acid plate
-
K. Ueki, K. Marukawa, M. Shimada, K. Nakagawa, S. Alam, and E. Yamamoto Maxillary stability following Le Fort I osteotomy in combination with sagittal split ramus osteotomy and intraoral vertical ramus osteotomy: a comparative study between titanium miniplate and poly-l-lactic acid plate J Oral Maxillofac Surg 64 2006 74 78
-
(2006)
J Oral Maxillofac Surg
, vol.64
, pp. 74-78
-
-
Ueki, K.1
Marukawa, K.2
Shimada, M.3
Nakagawa, K.4
Alam, S.5
Yamamoto, E.6
-
6
-
-
17844398221
-
The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly l-lactide (F-u-HA/PLLA)
-
DOI 10.1016/j.biomaterials.2005.02.016
-
Y. Shikinami, and T. Matsusue Nakamura The complete process of bioresorption and bone replacement using devices made of forged composite of raw hydroxyapatite particles/poly l-lactide (F-u-HA/PLLA) Biomaterials 26 2005 5542 5551 (Pubitemid 40592141)
-
(2005)
Biomaterials
, vol.26
, Issue.27
, pp. 5542-5551
-
-
Shikinami, Y.1
Matsusue, Y.2
Nakamura, T.3
-
7
-
-
0033135945
-
Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. Basic characteristics
-
DOI 10.1016/S0142-9612(98)00241-5, PII S0142961298002415
-
Y. Shikinami, and M. Okuno Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-l-lactide (PLLA): part I. Basic characteristics Biomaterials 20 1999 859 877 (Pubitemid 29184767)
-
(1999)
Biomaterials
, vol.20
, Issue.9
, pp. 859-877
-
-
Shikinami, Y.1
Okuno, M.2
-
8
-
-
0034845979
-
Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly L-lactide (PLLA). Part II: Practical properties of miniscrews and miniplates
-
DOI 10.1016/S0142-9612(01)00072-2, PII S0142961201000722
-
Y. Shikinami, and M. Okuno Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-l-lactide (PLLA): part II. Practical properties of miniscrews and miniplates Biomaterials 22 2001 3197 3211 (Pubitemid 32826230)
-
(2001)
Biomaterials
, vol.22
, Issue.23
, pp. 3197-3211
-
-
Shikinami, Y.1
Okuno, M.2
-
9
-
-
79955019483
-
Skeletal stability after mandibular setback surgery: Comparisons among unsintered hydroxyapatite (u-HA)/poly-l-lactic acid (PLLA) plate. PLLA plate and titanium plate
-
January 6 [epub ahead of print]
-
K. Ueki, K. Okabe, M. Miyazaki, A. Mukozawa, A. Moroi, and K. Marukawa Skeletal stability after mandibular setback surgery: comparisons among unsintered hydroxyapatite (u-HA)/poly-l-lactic acid (PLLA) plate. PLLA plate and titanium plate J Oral Maxillifac Surg 2011 January 6 [epub ahead of print]
-
(2011)
J Oral Maxillifac Surg
-
-
Ueki, K.1
Okabe, K.2
Miyazaki, M.3
Mukozawa, A.4
Moroi, A.5
Marukawa, K.6
-
10
-
-
34547145165
-
G*power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
-
F. Faul, E. Erdfelder, A. Buchner, and A.G. Lang G*power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences Behav Res Methods 39 2007 175 191
-
(2007)
Behav Res Methods
, vol.39
, pp. 175-191
-
-
Faul, F.1
Erdfelder, E.2
Buchner, A.3
Lang, A.G.4
-
11
-
-
0028919553
-
Stability of le Fort i osteotomy with maxillary advancement: A comparison of combined wire fixation and rigid fixation
-
M. Egbert, B. Hepworth, R. Myall, and R. West Stability of Le Fort I osteotomy with maxillary advancement: a comparison of combined wire fixation and rigid fixation J Oral Maxillofac Surg 53 1995 243 248
-
(1995)
J Oral Maxillofac Surg
, vol.53
, pp. 243-248
-
-
Egbert, M.1
Hepworth, B.2
Myall, R.3
West, R.4
-
12
-
-
0026276551
-
Stability after surgical-orthodontic correction of skeletal class III malocclusion. II. Maxillary advancement
-
W.R. Proffit, C. Phillips, J.W. Prewitt, and T.A. Turvey Stability after surgical-orthodontic correction of skeletal class III malocclusion. II. Maxillary advancement Int J Adult Orthodon Orthognath Surg 6 1991 71 80
-
(1991)
Int J Adult Orthodon Orthognath Surg
, vol.6
, pp. 71-80
-
-
Proffit, W.R.1
Phillips, C.2
Prewitt, J.W.3
Turvey, T.A.4
-
13
-
-
0024245578
-
Stability of simultaneous maxillary intrusion and mandibular advancement: A comparison of rigid and nonrigid fixation techniques
-
L.J. Skoczlas, E. Ellis, R.J. Fonseca, and W.J. Gallo Stability of simultaneous maxillary intrusion and mandibular advancement: a comparison of rigid and nonrigid fixation techniques J Oral Maxillofac Surg 46 1988 1056 1064 (Pubitemid 19007814)
-
(1988)
Journal of Oral and Maxillofacial Surgery
, vol.46
, Issue.12
, pp. 1056-1064
-
-
Skoczylas, L.J.1
Ellis III, E.2
Fonseca, R.J.3
Gallo, W.J.4
-
15
-
-
0027082475
-
Long-term stability after inferior maxillary repositioning by miniplate fixation
-
DOI 10.1016/S0901-5027(05)80752-0
-
D.L. Baker, P.J.W. Stoelinga, P.A. Blijdorp, and J.J.l. Brous Long-term stability after inferior maxillary repositioning by miniplate fixation Int J Oral Maxillofac Surg 21 1992 320 326 (Pubitemid 23031264)
-
(1992)
International Journal of Oral and Maxillofacial Surgery
, vol.21
, Issue.6
, pp. 320-326
-
-
Baker, D.L.1
Stoelinga, P.J.W.2
Blijdorp, P.A.3
Brouns, J.J.A.4
-
16
-
-
0031753168
-
Stability of le Fort i osteotomy with advanced: A comparison of single maxillary surgery and two-jaw procedure
-
S. Bothur, J.E. Blomqvist, and S. Isaksson Stability of Le Fort I osteotomy with advanced: a comparison of single maxillary surgery and two-jaw procedure J Oral Maxillofac Surg 56 1998 1029 1033
-
(1998)
J Oral Maxillofac Surg
, vol.56
, pp. 1029-1033
-
-
Bothur, S.1
Blomqvist, J.E.2
Isaksson, S.3
-
18
-
-
0024501477
-
Stability following combined maxillary and mandibular osteotomies treated with rigid internal fixation
-
J.H. Law, K.S. Rotskoff, and R.J. Smith Stability following combined maxillary and mandibular osteotomies treated with rigid internal fixation J Oral Maxillofac Surg 47 1989 128 136 (Pubitemid 19056140)
-
(1989)
Journal of Oral and Maxillofacial Surgery
, vol.47
, Issue.2
, pp. 128-136
-
-
Law, J.H.1
Rotskoff, K.S.2
Smith, R.J.3
-
20
-
-
2342536354
-
Le Fort I miniplate osteosynthesis: A randomized, prospective study comparing resorbable PLLA/PGA with titanium
-
DOI 10.1006/ijom.2003.0505
-
S.E. Norholt, and T.K. Pedersen Le Fort I miniplate osteosynthesis: a randomized, prospective study comparing resorbable PLLA/PGA with titanium Int J Oral Maxillofac Surg 33 2004 245 252 (Pubitemid 38584952)
-
(2004)
International Journal of Oral and Maxillofacial Surgery
, vol.33
, Issue.3
, pp. 245-252
-
-
Norholt, S.E.1
Pedersen, T.K.2
Jensen, J.3
-
21
-
-
40249114842
-
Stability and morbidity of Le Fort I osteotomy with bioresorbable fixation: A randomized controlled trial
-
DOI 10.1016/j.ijom.2007.09.169, PII S0901502707009526
-
L.K. Cheung, I.H. Yip, and R.L. Chow Stability and morbidity of Le Fort I osteotomy with bioabsorbable fixation: a randomized controlled trial Int J Oral Surg 37 2008 232 241 (Pubitemid 351335240)
-
(2008)
International Journal of Oral and Maxillofacial Surgery
, vol.37
, Issue.3
, pp. 232-241
-
-
Cheung, L.K.1
Yip, I.H.S.2
Chow, R.L.K.3
-
22
-
-
33645062147
-
Stability of skeletal Class III malocclusion after combined maxillary and mandibular procedures: Titanium versus resorbable plates and screws for maxillary fixation
-
F. Costa, M. Robiony, E. Zorzan, N. Zerman, and M. Politi Stability of skeletal Class III malocclusion after combined maxillary and mandibular procedures: titanium versus resorbable plates and screws for maxillary fixation J Oral Maxillofac Surg 64 2006 642 651
-
(2006)
J Oral Maxillofac Surg
, vol.64
, pp. 642-651
-
-
Costa, F.1
Robiony, M.2
Zorzan, E.3
Zerman, N.4
Politi, M.5
-
23
-
-
0026549107
-
Biodegradable self-reinforced composite materials: Manufacturing structure and mechanical properties
-
P. Törmälä Biodegradable self-reinforced composite materials: manufacturing structure and mechanical properties Clin Mater 10 1992 29 34
-
(1992)
Clin Mater
, vol.10
, pp. 29-34
-
-
Törmälä, P.1
-
24
-
-
0026996669
-
In vitro and in vivo studies on bioabsorbable ultra-high-strength poly (l-lactide) rods
-
Y. Matsusue, T. Yamamuro, M. Oka, Y. Shikinami, S.H. Hyon, and Y. Ikada In vitro and in vivo studies on bioabsorbable ultra-high-strength poly (l-lactide) rods J Biomed Mater Res 26 1992 1553 1567
-
(1992)
J Biomed Mater Res
, vol.26
, pp. 1553-1567
-
-
Matsusue, Y.1
Yamamuro, T.2
Oka, M.3
Shikinami, Y.4
Hyon, S.H.5
Ikada, Y.6
-
26
-
-
0025389116
-
Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone
-
A.U. Daniel, M.K.O. Chang, and K.P. Andriano Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone J Appl Biomater 1 1990 57 78
-
(1990)
J Appl Biomater
, vol.1
, pp. 57-78
-
-
Daniel, A.U.1
Chang, M.K.O.2
Andriano, K.P.3
-
27
-
-
0036200479
-
Study by finite element method of the mechanical stress of selected biodegradable osteosynthesis screws in sagittal ramus osteotomy
-
DOI 10.1054/bjom.2001.0752
-
P. Maurer, S. Holweg, W.D. Knoll, and J. Schubert Study by finite element method of the mechanical stress of selected biodegradable osteosynthesis screws in sagittal ramus osteotomy Br J Oral Maxillofac Surg 40 2002 76 83 (Pubitemid 34257290)
-
(2002)
British Journal of Oral and Maxillofacial Surgery
, vol.40
, Issue.1
, pp. 76-83
-
-
Maurer, P.1
Holweg, S.2
Knoll, W.-D.3
Schubert, J.4
-
28
-
-
0036159280
-
Influence of bioresorbable, unsintered hydroxyapatite/poly-L-lactide composite films on spinal cord, nerve roots, and epidural space
-
DOI 10.1002/jbm.1283
-
M. Matsumoto, E. Chosa, K. Nabeshima, Y. Shikinami, and N. Tajima Influence of bioresorbable, unsintered hydroxyapatite/poly-l-lactide composite films on spinal corc, nerve roots, and epidural space J Biomed Mater Res 60 2002 101 109 (Pubitemid 34126991)
-
(2002)
Journal of Biomedical Materials Research
, vol.60
, Issue.1
, pp. 101-109
-
-
Matsumoto, M.1
Chosa, E.2
Nabeshima, K.3
Shikinami, Y.4
Tajima, N.5
-
29
-
-
0033527930
-
Bonding behavior of ultrahigh strength unsintered hydroxyapatite particles/poly (l-lactide) composites to surface of tibia cortex in rabbits
-
T. Yasunaga, Y. Matsusue, T. Furukawa, Y. Shikinami, M. Okuno, and T. Nakamura Bonding behavior of ultrahigh strength unsintered hydroxyapatite particles/poly (l-lactide) composites to surface of tibia cortex in rabbits J Biomed Mater Res 47 1999 412 419
-
(1999)
J Biomed Mater Res
, vol.47
, pp. 412-419
-
-
Yasunaga, T.1
Matsusue, Y.2
Furukawa, T.3
Shikinami, Y.4
Okuno, M.5
Nakamura, T.6
-
30
-
-
0034029863
-
Histomorphometric study on high-strength hydroxyapatite/poly(L-lactide) composite rods for internal fixation of bone fractures
-
DOI 10.1002/(SICI)1097-4636(20000605)50:3<410::AID-JBM16>3.0.CO;2-Y
-
T. Furukawa, Y. Matsusue, T. Yasunaga, Y. Nakagawa, Y. Okada, and Y. Shikinami Histomorphometric study on high-strength hydroxyapatite/poly (l-lactide) composite rods for internal fixation of bone fractures J Biomed Mater Res 50 2000 410 419 (Pubitemid 30180734)
-
(2000)
Journal of Biomedical Materials Research
, vol.50
, Issue.3
, pp. 410-419
-
-
Furukawa, T.1
Matsusue, Y.2
Yasunaga, T.3
Nakagawa, Y.4
Okada, Y.5
Shikinami, Y.6
Okuno, M.7
Nakamura, T.8
-
31
-
-
84860693900
-
Assessment of bone healing after le Fort i osteotomy with 3-dimensional computed tomography
-
August 10 [epub ahead of print]
-
K. Ueki, M. Miyazaki, K. Okabe, K. Mukozawa, A. Moroi, and K. Nakagawa Assessment of bone healing after Le Fort I osteotomy with 3-dimensional computed tomography J Cranio-Maxillofac Surg 2010 August 10 [epub ahead of print]
-
(2010)
J Cranio-Maxillofac Surg
-
-
Ueki, K.1
Miyazaki, M.2
Okabe, K.3
Mukozawa, K.4
Moroi, A.5
Nakagawa, K.6
|