메뉴 건너뛰기




Volumn 70, Issue 1, 2013, Pages 269-275

Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: Early experiments and simulations at 3 T

Author keywords

dielectric; MRI; signal to noise ratio

Indexed keywords

ELECTROMAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; PERMITTIVITY; SIGNAL TO NOISE RATIO; SINTERING;

EID: 84879411437     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24433     Document Type: Article
Times cited : (41)

References (29)
  • 2
    • 33947162337 scopus 로고    scopus 로고
    • A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3T
    • Sreenivas M, Lowry M, Gibbs P, Pickles M, Turnbull L,. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3T. Eur J Radiol 2007; 62: 143-146.
    • (2007) Eur J Radiol , vol.62 , pp. 143-146
    • Sreenivas, M.1    Lowry, M.2    Gibbs, P.3    Pickles, M.4    Turnbull, L.5
  • 4
    • 79251564440 scopus 로고    scopus 로고
    • Reducing SAR and enhancing cerebral signal-to-noise ratio with high permittivity padding at 3 T
    • Yang QX, Wang J, Wang J, Collins CM, Wang C, Smith MB,. Reducing SAR and enhancing cerebral signal-to-noise ratio with high permittivity padding at 3 T. Magn Reson Med 2011; 65: 358-362.
    • (2011) Magn Reson Med , vol.65 , pp. 358-362
    • Yang, Q.X.1    Wang, J.2    Wang, J.3    Collins, C.M.4    Wang, C.5    Smith, M.B.6
  • 6
    • 79960805414 scopus 로고    scopus 로고
    • Improvements in high-field localized MRS of the medial temporal lobe in humans using new deformable high-dielectric materials
    • Snaar J, Teeuwisse WM, Versluis MJ, Buchem Mv, Kan HE, Smith NB, Webb AG,. Improvements in high-field localized MRS of the medial temporal lobe in humans using new deformable high-dielectric materials. NMR Biomed 2010; 24: 873-879.
    • (2010) NMR Biomed , vol.24 , pp. 873-879
    • Snaar, J.1    Teeuwisse, W.M.2    Versluis, M.J.3    Buchem, M.4    Kan, H.E.5    Smith, N.B.6    Webb, A.G.7
  • 7
    • 77949491923 scopus 로고    scopus 로고
    • New high dielectric constant materials for tailoring the distribution at high magnetic fields
    • Haines K, Smith N, Webb A,. New high dielectric constant materials for tailoring the distribution at high magnetic fields. J Magn Reson 2010; 203: 323-327.
    • (2010) J Magn Reson , vol.203 , pp. 323-327
    • Haines, K.1    Smith, N.2    Webb, A.3
  • 8
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • Alsop DC, Connick TJ, Mizsei G,. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength. Magn Reson Med 1998; 40: 49-54.
    • (1998) Magn Reson Med , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizsei, G.3
  • 9
    • 68049087644 scopus 로고    scopus 로고
    • Dielectric inserts for sensitivity and RF magnetic field enhancement in NMR volume coils
    • Neufeld A, Landsberg N, Boag A,. Dielectric inserts for sensitivity and RF magnetic field enhancement in NMR volume coils. J Magn Reson 2009; 200: 49-55.
    • (2009) J Magn Reson , vol.200 , pp. 49-55
    • Neufeld, A.1    Landsberg, N.2    Boag, A.3
  • 10
    • 33745700347 scopus 로고    scopus 로고
    • Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materials
    • Yang QX, Mao W, Wang J, Smith MB, Lei H, Zhang X, Ugurbil K, Chen W,. Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials. J Magn Reson Imaging 2006; 24: 197-202.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 197-202
    • Yang, Q.X.1    Mao, W.2    Wang, J.3    Smith, M.B.4    Lei, H.5    Zhang, X.6    Ugurbil, K.7    Chen, W.8
  • 12
    • 79960758106 scopus 로고    scopus 로고
    • Dielectric materials in magnetic resonance
    • Webb AG,. Dielectric materials in magnetic resonance. Concept Magn Res A 2011; 38A: 148-184.
    • (2011) Concept Magn Res A , vol.38 A , pp. 148-184
    • Webb, A.G.1
  • 13
    • 84859099829 scopus 로고    scopus 로고
    • Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric
    • Teeuwisse WM, Brink WM, Haines KN, Webb AG,. Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric. Magn Reson Med 2012; 67: 912-918.
    • (2012) Magn Reson Med , vol.67 , pp. 912-918
    • Teeuwisse, W.M.1    Brink, W.M.2    Haines, K.N.3    Webb, A.G.4
  • 14
  • 15
    • 0004099829 scopus 로고
    • Reading, MA: Addison-Wesley Publishing Compnay
    • Pozar DM,. Microwave engineering. Reading, MA: Addison-Wesley Publishing Compnay; 1990.
    • (1990) Microwave Engineering
    • Pozar, D.M.1
  • 16
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200.
    • (2007) Magn Reson Med , vol.57 , pp. 192-200
    • Yarnykh, V.L.1
  • 17
    • 60349112457 scopus 로고    scopus 로고
    • On the steady-state properties of actual flip angle imaging (AFI)
    • Nehrke K,. On the steady-state properties of actual flip angle imaging (AFI). Magn Reson Med 2009; 61: 84-92.
    • (2009) Magn Reson Med , vol.61 , pp. 84-92
    • Nehrke, K.1
  • 18
    • 77952705528 scopus 로고    scopus 로고
    • Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques
    • Yarnykh VL,. Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques. Magn Reson Med 2010; 63: 1610-1626.
    • (2010) Magn Reson Med , vol.63 , pp. 1610-1626
    • Yarnykh, V.L.1
  • 19
    • 0035088714 scopus 로고    scopus 로고
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 2001; 45: 692-699.
    • (2001) Magn Reson Med , vol.45 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 20
    • 0035088728 scopus 로고    scopus 로고
    • Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil
    • Collins CM, Smith MB,. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil. Magn Reson Med 2001; 45: 684-691.
    • (2001) Magn Reson Med , vol.45 , pp. 684-691
    • Collins, C.M.1    Smith, M.B.2
  • 21
    • 84879418032 scopus 로고    scopus 로고
    • Quadrature surface coils
    • doi:10.1002/9780470034590.emrstm1115
    • Collins CM, Webb AG,. Quadrature surface coils. Encyclopedia Magn Reson 2010. doi:10.1002/9780470034590.emrstm1115
    • (2010) Encyclopedia Magn Reson
    • Collins, C.M.1    Webb, A.G.2
  • 23
    • 12744262814 scopus 로고    scopus 로고
    • Central brightening due to constructive interference with, without, and despite dielectric resonance
    • Collins CM, Liu W, Schreiber W, Yang QX, Smith MB,. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging 2005; 21: 192-196.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 192-196
    • Collins, C.M.1    Liu, W.2    Schreiber, W.3    Yang, Q.X.4    Smith, M.B.5
  • 24
    • 84859722309 scopus 로고    scopus 로고
    • Quantitative assessment of the effects of high-permittivity pads in 7 Tesla MRI of the brain
    • Webb AG, Teeuwisse WM, Brink WM,. Quantitative assessment of the effects of high-permittivity pads in 7 Tesla MRI of the brain. Magn Reson Med 2011; 67: 1285-1293.
    • (2011) Magn Reson Med , vol.67 , pp. 1285-1293
    • Webb, A.G.1    Teeuwisse, W.M.2    Brink, W.M.3
  • 25
    • 77949541162 scopus 로고    scopus 로고
    • Derivation of Lichtenecker's logarithmic mixture formula from Maxwell's equations
    • Simpkin R,. Derivation of Lichtenecker's logarithmic mixture formula from Maxwell's equations. IEEE Trans Microwave Theory Tech 2010; 58: 545-550.
    • (2010) IEEE Trans Microwave Theory Tech , vol.58 , pp. 545-550
    • Simpkin, R.1
  • 26
    • 56749096056 scopus 로고    scopus 로고
    • Dielectric constant of barium titanate powders near Curie temperature
    • Dogan F, Petrovsky V, Petrovsky T, Kamlapurkar S,. Dielectric constant of barium titanate powders near Curie temperature. J Am Ceram Soc 2008; 91: 3590-3592.
    • (2008) J Am Ceram Soc , vol.91 , pp. 3590-3592
    • Dogan, F.1    Petrovsky, V.2    Petrovsky, T.3    Kamlapurkar, S.4
  • 27
    • 84978580975 scopus 로고
    • Mechanical packing of spherical particles
    • McGeary RK,. Mechanical packing of spherical particles. J Am Ceram Soc 1961; 44: 513-522
    • (1961) J Am Ceram Soc , vol.44 , pp. 513-522
    • McGeary, R.K.1
  • 29
    • 0033876659 scopus 로고    scopus 로고
    • Room-temperature solubility behavior of barium titanate in aqueous media
    • Neubrand A, Lindner R, Hoffmann P,. Room-temperature solubility behavior of barium titanate in aqueous media. J Am Ceram Soc 2000; 83: 860-864.
    • (2000) J Am Ceram Soc , vol.83 , pp. 860-864
    • Neubrand, A.1    Lindner, R.2    Hoffmann, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.