메뉴 건너뛰기




Volumn 61, Issue 1, 2009, Pages 84-92

On the steady-state properties of actual flip angle imaging (AFI)

Author keywords

B1 mapping; RF excitation; RF spoiling, configuration theory, diffusion

Indexed keywords

TISSUE;

EID: 60349112457     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21592     Document Type: Article
Times cited : (93)

References (23)
  • 1
    • 36348998721 scopus 로고    scopus 로고
    • Fast, accurate, and precise mapping of the RF field in vivo using the 180 degrees signal null
    • Dowell NG, Tofts PS. Fast, accurate, and precise mapping of the RF field in vivo using the 180 degrees signal null. Magn Reson Med 2007;58:622-630.
    • (2007) Magn Reson Med , vol.58 , pp. 622-630
    • Dowell, N.G.1    Tofts, P.S.2
  • 3
    • 1842586446 scopus 로고    scopus 로고
    • Parallel excitation with an array of transmit coils
    • Zhu Y. Parallel excitation with an array of transmit coils. Magn Reson Med 2004;51:775-784.
    • (2004) Magn Reson Med , vol.51 , pp. 775-784
    • Zhu, Y.1
  • 4
    • 0022647027 scopus 로고
    • High-order coils as transmitters for NMR imaging
    • Sotgiu A, Hyde JS. High-order coils as transmitters for NMR imaging. Magn Reson Med 1986;3:55-62.
    • (1986) Magn Reson Med , vol.3 , pp. 55-62
    • Sotgiu, A.1    Hyde, J.S.2
  • 5
    • 0029664366 scopus 로고    scopus 로고
    • Imaging of the active B1 field in vivo
    • Stollberger R, Wach P. Imaging of the active B1 field in vivo. Magn Reson Med 1996;35:246-251.
    • (1996) Magn Reson Med , vol.35 , pp. 246-251
    • Stollberger, R.1    Wach, P.2
  • 6
    • 0034026246 scopus 로고    scopus 로고
    • Correction for B1 and B0 variations in quantitative T2 measurements using MRI
    • Sled JG, Pike GB. Correction for B1 and B0 variations in quantitative T2 measurements using MRI. Magn Reson Med 2000;43:589-593.
    • (2000) Magn Reson Med , vol.43 , pp. 589-593
    • Sled, J.G.1    Pike, G.B.2
  • 7
    • 0034956814 scopus 로고    scopus 로고
    • Trabecular bone volume fraction mapping by low-resolution MRI
    • Fernandez-Seara MA, Song HK, Wehrli FW. Trabecular bone volume fraction mapping by low-resolution MRI. Magn Reson Med 2001;46:103-113.
    • (2001) Magn Reson Med , vol.46 , pp. 103-113
    • Fernandez-Seara, M.A.1    Song, H.K.2    Wehrli, F.W.3
  • 8
    • 14744284381 scopus 로고    scopus 로고
    • In vivo method for correcting transmit/receive nonuniformities with phased array coils
    • Wang J, Qiu M, Constable RT. In vivo method for correcting transmit/receive nonuniformities with phased array coils. Magn Reson Med 2005;53:666-674.
    • (2005) Magn Reson Med , vol.53 , pp. 666-674
    • Wang, J.1    Qiu, M.2    Constable, R.T.3
  • 9
    • 33744956872 scopus 로고    scopus 로고
    • Saturated double-angle method for rapid B1 mapping
    • Cunningham CH, Pauly JM, Nayak KS. Saturated double-angle method for rapid B1 mapping. Magn Reson Med 2006;55:1326-1333.
    • (2006) Magn Reson Med , vol.55 , pp. 1326-1333
    • Cunningham, C.H.1    Pauly, J.M.2    Nayak, K.S.3
  • 11
    • 0025160242 scopus 로고
    • Rapid radiofrequency calibration in MRI
    • Carlson JW, Kramer DM. Rapid radiofrequency calibration in MRI. Magn Reson Med 1990;15:438-445.
    • (1990) Magn Reson Med , vol.15 , pp. 438-445
    • Carlson, J.W.1    Kramer, D.M.2
  • 13
    • 33845263696 scopus 로고    scopus 로고
    • Fast 3D radiofrequency field mapping using echoplanar imaging
    • Jiru F, Klose U. Fast 3D radiofrequency field mapping using echoplanar imaging. Magn Reson Med 2006;56:1375-1379.
    • (2006) Magn Reson Med , vol.56 , pp. 1375-1379
    • Jiru, F.1    Klose, U.2
  • 14
    • 33744953870 scopus 로고    scopus 로고
    • Actual flip angle imaging in the pulsed steady state
    • Kyoto, Japan;, Abstract 194
    • Yarnykh VL, Yuan C. Actual flip angle imaging in the pulsed steady state. In: Proc 12th Annual Meeting ISMRM, Kyoto, Japan; 2004 (Abstract 194).
    • (2004) Proc 12th Annual Meeting ISMRM
    • Yarnykh, V.L.1    Yuan, C.2
  • 15
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radio-frequency field
    • Yarnykh VL. Actual flip angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radio-frequency field. Magn Reson Med 2007;57:192-200.
    • (2007) Magn Reson Med , vol.57 , pp. 192-200
    • Yarnykh, V.L.1
  • 16
    • 33847765063 scopus 로고    scopus 로고
    • Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI
    • Treier R, Steingoetter A, Fried M, Schwizer W, Boesiger P. Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI. Magn Reson Med 2007;57:568-576.
    • (2007) Magn Reson Med , vol.57 , pp. 568-576
    • Treier, R.1    Steingoetter, A.2    Fried, M.3    Schwizer, W.4    Boesiger, P.5
  • 17
    • 0001423628 scopus 로고
    • Effects of diffusion in nuclear magnetic resonance spin-echo experiments
    • Woessner DE. Effects of diffusion in nuclear magnetic resonance spin-echo experiments. J Chem Phys 1961;34:2057-2061.
    • (1961) J Chem Phys , vol.34 , pp. 2057-2061
    • Woessner, D.E.1
  • 18
    • 84985848260 scopus 로고
    • Echoes: How to generate, recognise, use or avoid them in MR imaging sequences
    • Hennig J. Echoes: how to generate, recognise, use or avoid them in MR imaging sequences. Concepts Magn Reson 1991;3:125-143.
    • (1991) Concepts Magn Reson , vol.3 , pp. 125-143
    • Hennig, J.1
  • 19
    • 30344464111 scopus 로고    scopus 로고
    • Steady state of gradient echo sequences with radiofrequency phase cycling: Analytical solution, contrast enhancement with partial spoiling
    • Ganter C. Steady state of gradient echo sequences with radiofrequency phase cycling: analytical solution, contrast enhancement with partial spoiling. Magn Reson Med 2006;55:98-107.
    • (2006) Magn Reson Med , vol.55 , pp. 98-107
    • Ganter, C.1
  • 20
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer J. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991;21:251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, J.3
  • 22
    • 33748923109 scopus 로고    scopus 로고
    • Mild cognitive impairment: Apparent diffusion coefficient in regional gray matter and white matter structures
    • Ray KM, Wang H, Chu Y, Chen YF, Bert A, Hasso AN, Su MY. Mild cognitive impairment: apparent diffusion coefficient in regional gray matter and white matter structures. Radiology 2006;241:197-205.
    • (2006) Radiology , vol.241 , pp. 197-205
    • Ray, K.M.1    Wang, H.2    Chu, Y.3    Chen, Y.F.4    Bert, A.5    Hasso, A.N.6    Su, M.Y.7
  • 23
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, Aung W, Himeno Y, Nakagawa T, Shibuya H. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 1999;210:617-623.
    • (1999) Radiology , vol.210 , pp. 617-623
    • Yamada, I.1    Aung, W.2    Himeno, Y.3    Nakagawa, T.4    Shibuya, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.