메뉴 건너뛰기




Volumn 24, Issue 1, 2006, Pages 197-202

Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materials

Author keywords

FDTD; High field MRI; RF field focusing; RF field inhomogeneity; RF field passive shim

Indexed keywords

ARTICLE; BRAIN; DIELECTRIC CONSTANT; ELECTRIC FIELD; HEAD; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; MAGNETIC FIELD; MATERIALS; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOFREQUENCY; WHOLE BODY SCANNER;

EID: 33745700347     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20603     Document Type: Article
Times cited : (138)

References (28)
  • 2
    • 0034962138 scopus 로고    scopus 로고
    • 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
    • Vaughan JT, Garwood M, Collins CM, et al. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med 2001;46:24-30.
    • (2001) Magn Reson Med , vol.46 , pp. 24-30
    • Vaughan, J.T.1    Garwood, M.2    Collins, C.M.3
  • 4
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult DI, Phil D. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 2000;12:46-67.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 46-67
    • Hoult, D.I.1    Phil, D.2
  • 5
    • 0036238849 scopus 로고    scopus 로고
    • Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
    • Collins CM, Yang QX, Wang JH, et al. Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz. Magn Reson Med 2002;47:1026-1028.
    • (2002) Magn Reson Med , vol.47 , pp. 1026-1028
    • Collins, C.M.1    Yang, Q.X.2    Wang, J.H.3
  • 6
    • 0036240672 scopus 로고    scopus 로고
    • Analysis of wave behavior in lossy dielectric samples at high field
    • Yang QX, Wang J, Zhang X, et al. Analysis of wave behavior in lossy dielectric samples at high field. Magn Reson Med 2002;47:982-989.
    • (2002) Magn Reson Med , vol.47 , pp. 982-989
    • Yang, Q.X.1    Wang, J.2    Zhang, X.3
  • 7
    • 0036324249 scopus 로고    scopus 로고
    • Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0 T
    • Wang J, Yang QX, Zhang X, et al. Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0 T. Magn Reson Med 2002;48:362-369.
    • (2002) Magn Reson Med , vol.48 , pp. 362-369
    • Wang, J.1    Yang, Q.X.2    Zhang, X.3
  • 8
    • 0026567364 scopus 로고
    • Reduction of RF penetration effects in high field imaging
    • Foo TK, Hayes C, Kang YW. Reduction of RF penetration effects in high field imaging. Magn Reson Med 1992;23:287-301.
    • (1992) Magn Reson Med , vol.23 , pp. 287-301
    • Foo, T.K.1    Hayes, C.2    Kang, Y.W.3
  • 9
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • Alsop DC, Connick TJ, Mizsei G. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength. Magn Reson Med 1998;40:49-54.
    • (1998) Magn Reson Med , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizsei, G.3
  • 12
    • 0035088714 scopus 로고    scopus 로고
    • Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • Collins CM, Smith MB. Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 2001;45:692-699.
    • (2001) Magn Reson Med , vol.45 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 14
    • 0024020391 scopus 로고
    • Spectroscopy and imaging with a 4 tesla whole-body MR system
    • Bomsdorf H, Helzel T, Kunz D, et al. Spectroscopy and imaging with a 4 tesla whole-body MR system. NMR Biomed 1988;1:151-158.
    • (1988) NMR Biomed , vol.1 , pp. 151-158
    • Bomsdorf, H.1    Helzel, T.2    Kunz, D.3
  • 15
    • 4243556316 scopus 로고
    • Standing waves in uniform water phantoms
    • Tofts PS. Standing waves in uniform water phantoms. J Magn Reson Ser B 1994;104:1-5.
    • (1994) J Magn Reson Ser B , vol.104 , pp. 1-5
    • Tofts, P.S.1
  • 16
    • 0027989884 scopus 로고
    • High frequency volume coils for clinical NMR imaging and spectroscopy
    • Vaughan JT, Hetherington HP, Otu JO, et al. High frequency volume coils for clinical NMR imaging and spectroscopy. Magn Reson Med 1994;32:206-218.
    • (1994) Magn Reson Med , vol.32 , pp. 206-218
    • Vaughan, J.T.1    Hetherington, H.P.2    Otu, J.O.3
  • 17
    • 0032129166 scopus 로고    scopus 로고
    • Standing wave and RF penetration artifacts caused by elliptic geometry: An electrodynamics analysis
    • Sled JG, Pike GB. Standing wave and RF penetration artifacts caused by elliptic geometry: an electrodynamics analysis. IEEE Trans Med Imaging 1998;17:653-662.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 653-662
    • Sled, J.G.1    Pike, G.B.2
  • 18
    • 12744262814 scopus 로고    scopus 로고
    • Central brightening due to constructive interference with, without, and despite dielectric resonance
    • Collins CM, Liu W, Schreiber W, Yang QX, Smith MB. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging 2005;21:192-196.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 192-196
    • Collins, C.M.1    Liu, W.2    Schreiber, W.3    Yang, Q.X.4    Smith, M.B.5
  • 19
    • 0001184266 scopus 로고
    • Comparison of linear and circular polarization for magnetic resonance imaging
    • Glover GH, Hayes CE, Helc NJ, et al. Comparison of linear and circular polarization for magnetic resonance imaging. J Magn Reson 1985;64:255-270.
    • (1985) J Magn Reson , vol.64 , pp. 255-270
    • Glover, G.H.1    Hayes, C.E.2    Helc, N.J.3
  • 20
    • 33745723633 scopus 로고    scopus 로고
    • Simulation on passive RF shimming in ultra-high field with high permittivity dielectrics
    • Miami Beach, FL, USA
    • Mao W, Smith MB, Yang QY. Simulation on passive RF shimming in ultra-high field with high permittivity dielectrics. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005. p 821.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 821
    • Mao, W.1    Smith, M.B.2    Yang, Q.Y.3
  • 23
    • 0033853121 scopus 로고    scopus 로고
    • Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging
    • Cohen MS, DuBois RM, Zeineh MM. Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging. Hum Brain Mapp 2000;10:204-211.
    • (2000) Hum Brain Mapp , vol.10 , pp. 204-211
    • Cohen, M.S.1    Dubois, R.M.2    Zeineh, M.M.3
  • 24
    • 0035112409 scopus 로고    scopus 로고
    • A multi-scale method for automatic correction of intensity non-uniformity in MR images
    • Han C, Hatsukami TS, Yuan C. A multi-scale method for automatic correction of intensity non-uniformity in MR images. J Magn Reson Imaging. 2001;13:428-436.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 428-436
    • Han, C.1    Hatsukami, T.S.2    Yuan, C.3
  • 25
    • 28444463083 scopus 로고    scopus 로고
    • Compensation of dielectric resonance effects by means of composite excitation pulses
    • Toronto, Canada
    • Thesen S, Krueger G, Mueller E. Compensation of dielectric resonance effects by means of composite excitation pulses. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 715.
    • (2003) Proceedings of the 11th Annual Meeting of ISMRM , pp. 715
    • Thesen, S.1    Krueger, G.2    Mueller, E.3
  • 26
    • 0038150142 scopus 로고    scopus 로고
    • A microstrip transmission line volume coil for human head MR imaging at 4T
    • Zhang X, Ugurbil K, Chen W. A microstrip transmission line volume coil for human head MR imaging at 4T. J Magn Reson 2003; 161:242-251.
    • (2003) J Magn Reson , vol.161 , pp. 242-251
    • Zhang, X.1    Ugurbil, K.2    Chen, W.3
  • 27
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.