Reactions of the articular capsule to wear products of artificial joint prostheses
-
Willert HG. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 1977;11:157-164
-
(1977)
J Biomed Mater Res
, vol.11
, pp. 157-164
-
-
Willert, H.G.1
-
2
-
-
0032949430
-
Analysis of 118 second-generation metal-on-metal retrieved hip implants
-
Sieber H-P, Rieker CB, Kottig P. Analysis of 118 second-generation metal-on-metal retrieved hip implants. J Bone Joint Surg Br B 1999;81:46-50
-
(1999)
J Bone Joint Surg Br B
, vol.81
, pp. 46-50
-
-
Sieber, H.-P.1
Rieker, C.B.2
Kottig, P.3
-
3
-
-
9644275369
-
Development and validation of a second-generation metal-on-metal bearing: Laboratory studies and analysis of retrievals
-
Rieker CB, Schön R, Köttig P. Development and validation of a second-generation metal-on-metal bearing: Laboratory studies and analysis of retrievals. J Arthroplast 2004;19(8, Suppl 1):5-11
-
(2004)
J Arthroplast
, vol.19
, Issue.8 SUPPL.1
, pp. 5-11
-
-
Rieker, C.B.1
Schön, R.2
Köttig, P.3
-
4
-
-
16244380151
-
The long-term wear of retrieved mckee-farrar metalon-metal total hip prostheses
-
Howie DW, McCalden RW, Nawana NS, Costi K, Pearcy MJ, Subramanian C. The long-term wear of retrieved mckee-farrar metalon- metal total hip prostheses. J Arthroplast 2005;20:350-357
-
(2005)
J Arthroplast
, vol.20
, pp. 350-357
-
-
Howie, D.W.1
McCalden, R.W.2
Nawana, N.S.3
Costi, K.4
Pearcy, M.J.5
Subramanian, C.6
-
5
-
-
33845409669
-
The John Charnley Award: A study of implant failure in metal-on-metal surface arthroplasties
-
Campbell P, Beaule PE, Ebramzadeh E, LeDuff M, De Smet K, Lu Z, Amstutz HC. The John Charnley Award: A study of implant failure in metal-on-metal surface arthroplasties. Clin Orthop Relat Res 2006;453:35-46
-
(2006)
Clin Orthop Relat Re
, vol.453
, pp. 35-46
-
-
Campbell, P.1
Beaule, P.E.2
Ebramzadeh, E.3
LeDuff, M.4
De Smet, K.5
Lu, Z.6
Amstutz, H.C.7
-
6
-
-
49849087899
-
Modes of implant failure after hip resurfacing: Morphological and wear analysis of 267 retrieval specimens
-
Morlock MM, Bishop N, Zustin J, Hahn M, Ruther W, Amling M. Modes of implant failure after hip resurfacing: Morphological and wear analysis of 267 retrieval specimens. J Bone Joint Surg-Am A 2008;90:89-95
-
(2008)
J Bone Joint Surg-Am A
, vol.90
, pp. 89-95
-
-
Morlock, M.M.1
Bishop, N.2
Zustin, J.3
Hahn, M.4
Ruther, W.5
Amling, M.6
-
7
-
-
0033256670
-
The otto aufranc award. Wear and lubrication of metal-on-metal hip implants
-
Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M. The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin Orthop Relat Res 1999:10-24
-
(1999)
Clin Orthop Relat Res
, pp. 10-24
-
-
Chan, F.W.1
Bobyn, J.D.2
Medley, J.B.3
Krygier, J.J.4
Tanzer, M.5
-
8
-
-
0035045395
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
-
Firkins PJ, Tipper JL, Saadatzadeh MR, Ingham E, Stone MH, Farrar R, Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001;11:143-157
-
(2001)
Biomed Mater Eng
, vol.11
, pp. 143-157
-
-
Firkins, P.J.1
Tipper, J.L.2
Saadatzadeh, M.R.3
Ingham, E.4
Stone, M.H.5
Farrar, R.6
Fisher, J.7
-
9
-
-
0033630259
-
A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
-
Goldsmith AA, Dowson D, Isaac GH, Lancaster JG. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proc Inst Mech Eng [H] 2000;214:39-47
-
(2000)
Proc Inst Mech Eng [H]
, vol.214
, pp. 39-47
-
-
Goldsmith, A.A.1
Dowson, D.2
Isaac, G.H.3
Lancaster, J.G.4
-
10
-
-
77649206363
-
Analysis of wear of retrieved metal-onmetal hip resurfacing implants revised due to pseudotumours
-
Kwon Y-M, Glyn-Jones S, Simpson DJ, Kamali A, McLardy-Smith P, Gill HS, Murray DW. Analysis of wear of retrieved metal-onmetal hip resurfacing implants revised due to pseudotumours. J Bone Joint Surg Br B 2010;92:356-361
-
(2010)
J Bone Joint Surg Br B
, vol.92
, pp. 356-361
-
-
Kwon, Y.-M.1
Glyn-Jones, S.2
Simpson, D.J.3
Kamali, A.4
McLardy-Smith, P.5
Gill, H.S.6
Murray, D.W.7
-
11
-
-
53849111555
-
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
-
De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 2008;90:1291-1297
-
(2008)
J Bone Joint Surg Br
, vol.90
, pp. 1291-1297
-
-
De Haan, R.1
Pattyn, C.2
Gill, H.S.3
Murray, D.W.4
Campbell, P.A.5
De Smet, K.6
-
12
-
-
3442890535
-
Metal-onmetal bearing wear with different swing phase loads
-
Williams S, Stewart TD, Ingham E, Stone MH, Fisher J. Metal-onmetal bearing wear with different swing phase loads. J Biomed Mater Res Part B: Appl Biomater 2004;70:233-239
-
(2004)
J Biomed Mater Res Part B: Appl Biomater
, vol.70
, pp. 233-239
-
-
Williams, S.1
Stewart, T.D.2
Ingham, E.3
Stone, M.H.4
Fisher, J.5
-
14
-
-
69249208803
-
High cup angle and microseparation increase the wear of hip surface replacements
-
Leslie IJ, Williams S, Isaac G, Ingham E, Fisher J. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthopaed Related Res 2009;467:2259-2265
-
(2009)
Clin Orthopaed Related Res
, vol.467
, pp. 2259-2265
-
-
Leslie, I.J.1
Williams, S.2
Isaac, G.3
Ingham, E.4
Fisher, J.5
-
15
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
-
Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999;20:1833-1840
-
(1999)
Biomaterials
, vol.20
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Fisher, J.4
Nevelos, A.B.5
-
16
-
-
0034981637
-
Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening
-
Nevelos JE, Prudhommeaux F, Hamadouche M, Doyle C, Ingham E, Meunier A, Nevelos AB, Sedel L, Fisher J. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br 2001;83:598-603
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 598-603
-
-
Nevelos, J.E.1
Prudhommeaux, F.2
Hamadouche, M.3
Doyle, C.4
Ingham, E.5
Meunier, A.6
Nevelos, A.B.7
Sedel, L.8
Fisher, J.9
-
17
-
-
0035114433
-
The influence of acetabular cup angle on the wear of BIOLOX forte alumina ceramic bearing couples in a hip joint simulator
-
Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J. The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001;12:141-144
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 141-144
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
18
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Nevelos J, Ingham E, Doyle C, Streicher R, Nevelos A, Walter W, Fisher J. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplast 2000;15:793-795
-
(2000)
J Arthroplast
, vol.15
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
Fisher, J.7
-
19
-
-
0035989711
-
Alumina-alumina artificial hip joints, Part 1: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision
-
Hatton A, Nevelos JE, Nevelos AA, Banks RE, Fisher J, Ingham E. Alumina-alumina artificial hip joints, Part 1: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials 2002;23:3429-3440
-
(2002)
Biomaterials
, vol.23
, pp. 3429-3440
-
-
Hatton, A.1
Nevelos, J.E.2
Nevelos, A.A.3
Banks, R.E.4
Fisher, J.5
Ingham, E.6
-
20
-
-
0035989715
-
Alumina-alumina artificial hip joints, Part 2: Characterisation of the wear debris from in vitro hip joint simulations
-
Tipper JL, Hatton A, Nevelos JE, Ingham E, Doyle C, Streicher R, Nevelos AB, Fisher J. Alumina-alumina artificial hip joints, Part 2:Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002;23:3441-3448
-
(2002)
Biomaterials
, vol.23
, pp. 3441-3448
-
-
Tipper, J.L.1
Hatton, A.2
Nevelos, J.E.3
Ingham, E.4
Doyle, C.5
Streicher, R.6
Nevelos, A.B.7
Fisher, J.8
-
21
-
-
0028805203
-
Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty
-
McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME. Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br 1995;77:865-869
-
(1995)
J Bone Joint Surg Br
, vol.77
, pp. 865-869
-
-
McGrory, B.J.1
Morrey, B.F.2
Cahalan, T.D.3
An, K.N.4
Cabanela, M.E.5
-
22
-
-
0028042344
-
High hip center in revision arthroplasty
-
Kelley SS. High hip center in revision arthroplasty. J Arthroplast 1994;9:503-510
-
(1994)
J Arthroplast
, vol.9
, pp. 503-510
-
-
Kelley, S.S.1
-
23
-
-
0036220260
-
Factors predisposing to dislocation after primary total hip arthroplasty: A multivariate analysis
-
Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip arthroplasty: A multivariate analysis. J Arthroplast 2002;17:282-288
-
(2002)
J Arthroplast
, vol.17
, pp. 282-288
-
-
Jolles, B.M.1
Zangger, P.2
Leyvraz, P.F.3
-
24
-
-
0036713568
-
Relationship between radiographic measurements of reconstructed hip joint position and the Trendelenburg sign
-
Asayama I, Naito M, Fujisawa M, Kambe T. Relationship between radiographic measurements of reconstructed hip joint position and the Trendelenburg sign. J Arthroplast 2002;17:747-751
-
(2002)
J Arthroplast
, vol.17
, pp. 747-751
-
-
Asayama, I.1
Naito, M.2
Fujisawa, M.3
Kambe, T.4
-
25
-
-
79960628879
-
Bioengineering reasons for the failure of metal-on-metal hip prostheses: An engineer's perspective
-
Fisher J. Bioengineering reasons for the failure of metal-on-metal hip prostheses: An engineer's perspective. J Bone Joint Surg Br 2011;93:1001-1004
-
(2011)
J Bone Joint Surg Br
, vol.93
, pp. 1001-1004
-
-
Fisher, J.1
-
26
-
-
49849095334
-
Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
-
Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J. Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position. J Bone Joint Surg Am 2008;90 (Suppl 3):111-117
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL.3
, pp. 111-117
-
-
Williams, S.1
Leslie, I.2
Isaac, G.3
Jin, Z.4
Ingham, E.5
Fisher, J.6
-
27
-
-
58149375619
-
A groin mass caused by metal particle debris after hip resurfacing
-
Counsell A, Heasley R, Arumilli B, Paul A. A groin mass caused by metal particle debris after hip resurfacing. Acta Orthop Belg 2008;74:870-874
-
(2008)
Acta Orthop Belg
, vol.74
, pp. 870-874
-
-
Counsell, A.1
Heasley, R.2
Arumilli, B.3
Paul, A.4
-
28
-
-
66349089540
-
The painful metal-on-metal hip resurfacing
-
Hart AJ, Sabah S, Henckel J, Lewis A, Cobb J, Sampson B, Mitchell A, Skinner JA. The painful metal-on-metal hip resurfacing. J Bone Joint Surg Br 2009;91:738-744
-
(2009)
J Bone Joint Surg Br
, vol.91
, pp. 738-744
-
-
Hart, A.J.1
Sabah, S.2
Henckel, J.3
Lewis, A.4
Cobb, J.5
Sampson, B.6
Mitchell, A.7
Skinner, J.A.8
-
29
-
-
47549111326
-
Pseudotumours associated with metal-on-metal hip resurfacings
-
Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2008;90:847-851
-
(2008)
J Bone Joint Surg Br
, vol.90
, pp. 847-851
-
-
Pandit, H.1
Glyn-Jones, S.2
McLardy-Smith, P.3
Gundle, R.4
Whitwell, D.5
Gibbons, C.L.6
Ostlere, S.7
Athanasou, N.8
Gill, H.S.9
Murray, D.W.10
-
30
-
-
55849087920
-
Clicking and squeaking: In vivo correlation of sound and separation for different bearing surfaces
-
Glaser D, Komistek RD, Cates HE, Mahfouz MR. Clicking and squeaking: In vivo correlation of sound and separation for different bearing surfaces. J Bone Joint Surg Am 2008;90 (Suppl 4):112-120
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL.4
, pp. 112-120
-
-
Glaser, D.1
Komistek, R.D.2
Cates, H.E.3
Mahfouz, M.R.4
-
31
-
-
0036796360
-
In vivo comparison of hip separation after metal-on-metal or metal-onpolyethylene total hip arthroplasty
-
Komistek RD, Dennis DA, Ochoa JA, Haas BD, Hammill C. In vivo comparison of hip separation after metal-on-metal or metal-onpolyethylene total hip arthroplasty. J Bone Joint Surg Am A 2002;84:1836-1841
-
(2002)
J Bone Joint Surg Am A
, vol.84
, pp. 1836-1841
-
-
Komistek, R.D.1
Dennis, D.A.2
Ochoa, J.A.3
Haas, B.D.4
Hammill, C.5
-
32
-
-
79952266303
-
Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing
-
Matthies A, Underwood R, Cann P, Ilo K, Nawaz Z, Skinner J, Hart AJ. Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. J Bone Joint Surg Br 2011;93:307-314
-
(2011)
J Bone Joint Surg Br
, vol.93
, pp. 307-314
-
-
Matthies, A.1
Underwood, R.2
Cann, P.3
Ilo, K.4
Nawaz, Z.5
Skinner, J.6
Hart, A.J.7
-
33
-
-
0035680629
-
Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
-
Stewart T, Tipper J, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001;12:1053-1056
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.2
Streicher, R.3
Ingham, E.4
Fisher, J.5
-
34
-
-
78649658341
-
Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX(R) delta ceramic-on-ceramic total hip replacement
-
Al-Hajjar M, Leslie IJ, Tipper J, Williams S, Fisher J, Jennings LM. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX(R) delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res Part B: Appl Biomater 2010;95:263-268
-
(2010)
J Biomed Mater Res Part B: Appl Biomater
, vol.95
, pp. 263-268
-
-
Al-Hajjar, M.1
Leslie, I.J.2
Tipper, J.3
Williams, S.4
Fisher, J.5
Jennings, L.M.6
-
35
-
-
0035882726
-
Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
-
Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001;22:2191-2197
-
(2001)
Biomaterials
, vol.22
, pp. 2191-2197
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
36
-
-
0141535277
-
Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. J Arthroplast 2003;18:726-734
-
(2003)
J Arthroplast
, vol.18
, pp. 726-734
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
37
-
-
0345168992
-
Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res Part B: Appl Biomater 2003;66:567-573
-
(2003)
J Biomed Mater Res Part B: Appl Biomater
, vol.66
, pp. 567-573
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
38
-
-
0035236287
-
New joints for the Millennium: Wear control in total replacement hip joints
-
Dowson D. New joints for the Millennium: Wear control in total replacement hip joints. Proc Inst Mech Eng [H] 2001;215:335-358
-
(2001)
Proc Inst Mech Eng [H]
, vol.215
, pp. 335-358
-
-
Dowson, D.1
-
39
-
-
0035065646
-
Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
-
Firkins PJ, Tipper JL, Ingham E, Stone MH, Farrar R, Fisher J. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proc Inst Mech Eng, Part H: J Eng Med 2001;215: 119-122
-
(2001)
Proc Inst Mech Eng, Part H: J Eng Med
, vol.215
, pp. 119-122
-
-
Firkins, P.J.1
Tipper, J.L.2
Ingham, E.3
Stone, M.H.4
Farrar, R.5
Fisher, J.6
-
40
-
-
34247543032
-
Larger diameter bearings reduce wear in metal-on-metal hip implants
-
Affatato S, Leardini W, Jedenmalm A, Ruggeri O, Toni A. Larger diameter bearings reduce wear in metal-on-metal hip implants. Clin Orthop Relat Res 2007;456:153-158
-
(2007)
Clin Orthop Relat Res
, vol.456
, pp. 153-158
-
-
Affatato, S.1
Leardini, W.2
Jedenmalm, A.3
Ruggeri, O.4
Toni, A.5
-
41
-
-
2542607724
-
Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses
-
Hu XQ, Isaac GH, Fisher J. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses. Biomed Mater Eng 2004;14:145-149
-
(2004)
Biomed Mater Eng
, vol.14
, pp. 145-149
-
-
Hu, X.Q.1
Isaac, G.H.2
Fisher, J.3
-
42
-
-
52449102219
-
Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements-An in vitro study
-
Leslie I, Williams S, Brown C, Isaac G, Jin ZM, Ingham E, Fisher J. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements-An in vitro study. J Biomed Mater Res Part B: Appl Biomater 2008;87: 163-172
-
(2008)
J Biomed Mater Res Part B: Appl Biomater
, vol.87
, pp. 163-172
-
-
Leslie, I.1
Williams, S.2
Brown, C.3
Isaac, G.4
Jin, Z.M.5
Ingham, E.6
Fisher, J.7
-
43
-
-
0035229408
-
The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
-
Smith SL, Dowson D, Goldsmith AA. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc Inst Mech Eng [H] 2001;215:161-170
-
(2001)
Proc Inst Mech Eng [H]
, vol.215
, pp. 161-170
-
-
Smith, S.L.1
Dowson, D.2
Goldsmith, A.A.3
-
44
-
-
37349127412
-
The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: A comparative in vitro and in vivo study
-
Williams S, Schepers A, Isaac G, Hardaker C, Ingham E, van der Jagt D, Breckon A, Fisher J. The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 2007;465:23-32
-
(2007)
Clin Orthop Relat Res
, vol.465
, pp. 23-32
-
-
Williams, S.1
Schepers, A.2
Isaac, G.3
Hardaker, C.4
Ingham, E.5
Van Der Jagt, D.6
Breckon, A.7
Fisher, J.8
-
46
-
-
84887084970
-
-
Long Beach, CA: Wiley
-
Wang L, Williams S, Isaac G, Jin Z, Fisher J. Effect of Acetabular Cup Orientation and Design on the Contact Mechanics and Range of Motion of Metal-on-Metal Hip Resurfacing Prostheses. Long Beach, CA: Wiley; 2011
-
(2011)
Effect of Acetabular Cup Orientation and Design on the Contact Mechanics and Range of Motion of Metal-on-Metal Hip Resurfacing Prostheses
-
-
Wang, L.1
Williams, S.2
Isaac, G.3
Jin, Z.4
Fisher, J.5
-
47
-
-
33645227809
-
Wear particles from metal-on-metal total hip replacements: Effects of implant design and implantation time
-
Catelas I, Campbell PA, Bobyn JD, Medley JB, Huk OL. Wear particles from metal-on-metal total hip replacements: Effects of implant design and implantation time. Proc Inst Mech Eng [H] 2006;220:195-208
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, pp. 195-208
-
-
Catelas, I.1
Campbell, P.A.2
Bobyn, J.D.3
Medley, J.B.4
Huk, O.L.5
-
48
-
-
2442507670
-
Stripe wear rates in alumina THR-Comparison of microseparation simulator study with retrieved implants
-
Manaka M, Clarke IC, Yamamoto K, Shishido T, Gustafson A, Imakiire A. Stripe wear rates in alumina THR-Comparison of microseparation simulator study with retrieved implants. J Biomed Mater Res Part B: Appl Biomater 2004;69:149-157
-
(2004)
J Biomed Mater Res Part B: Appl Biomater
, vol.69
, pp. 149-157
-
-
Manaka, M.1
Clarke, I.C.2
Yamamoto, K.3
Shishido, T.4
Gustafson, A.5
Imakiire, A.6
|