메뉴 건너뛰기




Volumn 35, Issue 8, 2013, Pages 1204-1211

Knee wear simulation under conditions of highly demanding daily activities - Influence on an unicompartmental fixed bearing knee design

Author keywords

Delamination; High demanding activities; Oxidation grade; Unicompartmental knee arthroplasty; Wear simulation

Indexed keywords

ARTIFICIAL AGEING; DAILY ACTIVITY; HIGH DEMANDING ACTIVITIES; KNEE ARTHROPLASTY; PATIENT ACTIVITIES; POLYETHYLENE INSERTS; TEST CONFIGURATIONS; WEAR SIMULATION;

EID: 84879029945     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2012.12.015     Document Type: Article
Times cited : (28)

References (55)
  • 2
    • 10444261188 scopus 로고    scopus 로고
    • The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    • McEwen H.M.J., Barnett P.I., Bell C.J., Farrar R., Auger D.D., Stone M.H., et al. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech 2005, 38:357-365.
    • (2005) J Biomech , vol.38 , pp. 357-365
    • McEwen, H.M.J.1    Barnett, P.I.2    Bell, C.J.3    Farrar, R.4    Auger, D.D.5    Stone, M.H.6
  • 3
    • 67650655738 scopus 로고    scopus 로고
    • Fixed bearing knee congruency - influence on contact mechanics, abrasive wear and kinematics
    • Grupp T.M., Stulberg D.S., Kaddick C., Maas A., Fritz B., Schwiesau J., et al. Fixed bearing knee congruency - influence on contact mechanics, abrasive wear and kinematics. Int J Artif Organs 2009, 32(4):213-223.
    • (2009) Int J Artif Organs , vol.32 , Issue.4 , pp. 213-223
    • Grupp, T.M.1    Stulberg, D.S.2    Kaddick, C.3    Maas, A.4    Fritz, B.5    Schwiesau, J.6
  • 4
    • 0026589837 scopus 로고
    • Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants
    • Wright T.M., Rimnac C.M., Stulberg S.D., Mintz L. Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. Clin Orthop Relat Res 1992, 276:126-134.
    • (1992) Clin Orthop Relat Res , vol.276 , pp. 126-134
    • Wright, T.M.1    Rimnac, C.M.2    Stulberg, S.D.3    Mintz, L.4
  • 5
    • 0031924955 scopus 로고    scopus 로고
    • Effect of oxidation of delamination of ultrahigh-molecular-weight polyethylene tibial components
    • Bell C.J., Walker P.S., Abeysundera M.R., Simmons J.M.H., King P.M., Blunn G.W. Effect of oxidation of delamination of ultrahigh-molecular-weight polyethylene tibial components. J Arthroplasty 1998, 13(3):280-290.
    • (1998) J Arthroplasty , vol.13 , Issue.3 , pp. 280-290
    • Bell, C.J.1    Walker, P.S.2    Abeysundera, M.R.3    Simmons, J.M.H.4    King, P.M.5    Blunn, G.W.6
  • 6
    • 34547646937 scopus 로고    scopus 로고
    • Unilateral tibial polyethylene liner failure in bilateral total knee arthroplasty - bilateral retrieval analysis at 8 years
    • Burnett R.S.J., Biggerstaff S., Currier B.H., Collier J.P., Barrack R.L. Unilateral tibial polyethylene liner failure in bilateral total knee arthroplasty - bilateral retrieval analysis at 8 years. J Arthroplasty 2007, 22(5):753-758.
    • (2007) J Arthroplasty , vol.22 , Issue.5 , pp. 753-758
    • Burnett, R.S.J.1    Biggerstaff, S.2    Currier, B.H.3    Collier, J.P.4    Barrack, R.L.5
  • 7
    • 65649122605 scopus 로고    scopus 로고
    • Premature failure of kinemax plus total knee replacements
    • Reay E., Wu J., Holland J., Deehan D. Premature failure of kinemax plus total knee replacements. J Bone Joint Surg Br 2009, 91B(5):604-611.
    • (2009) J Bone Joint Surg Br , vol.91 B , Issue.5 , pp. 604-611
    • Reay, E.1    Wu, J.2    Holland, J.3    Deehan, D.4
  • 8
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel D.L., Bicknell V.L., Wright T.M. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am 1986, 68A(7):1041-1051.
    • (1986) J Bone Joint Surg Am , vol.68 A , Issue.7 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 9
    • 0035235808 scopus 로고    scopus 로고
    • Maximizing ultra high molecular weight polyethylene performance in total knee replacement
    • Ayers D.C. Maximizing ultra high molecular weight polyethylene performance in total knee replacement. Instr Course Lect 2001, 50:421-429.
    • (2001) Instr Course Lect , vol.50 , pp. 421-429
    • Ayers, D.C.1
  • 10
    • 8644226074 scopus 로고    scopus 로고
    • Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee replacements - the Coventry Award Paper
    • [No. 428]
    • Fehring T.K., Murphy J.A., Hayes T.D., Roberts D.W., Pomeroy D.L., Griffin W.L. Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee replacements - the Coventry Award Paper. Clin Orth Relat Res 2004, 40-50. [No. 428].
    • (2004) Clin Orth Relat Res , pp. 40-50
    • Fehring, T.K.1    Murphy, J.A.2    Hayes, T.D.3    Roberts, D.W.4    Pomeroy, D.L.5    Griffin, W.L.6
  • 12
    • 35848960588 scopus 로고    scopus 로고
    • Sterilization and wear-related failure in first- and second-generation Press-Fit Condylar total knee arthroplasty - the Mark Coventry Award
    • [No. 464]
    • Griffin W.L., Fehring T.K., Pomeroy D.L., Gruen T.A., Murphy J.A. Sterilization and wear-related failure in first- and second-generation Press-Fit Condylar total knee arthroplasty - the Mark Coventry Award. Clin Orth Relat Res 2007, 16-20. [No. 464].
    • (2007) Clin Orth Relat Res , pp. 16-20
    • Griffin, W.L.1    Fehring, T.K.2    Pomeroy, D.L.3    Gruen, T.A.4    Murphy, J.A.5
  • 13
    • 33749235115 scopus 로고    scopus 로고
    • In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals
    • Wannomae K.K., Bhattacharyya S., Freiberg A., Estok D., Harris W.H., Muratoglu O. In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty 2006, 21(7):1005-1011.
    • (2006) J Arthroplasty , vol.21 , Issue.7 , pp. 1005-1011
    • Wannomae, K.K.1    Bhattacharyya, S.2    Freiberg, A.3    Estok, D.4    Harris, W.H.5    Muratoglu, O.6
  • 14
    • 33845444781 scopus 로고    scopus 로고
    • Significance of in vivo degradation for polyethylene in total hip arthroplasty - the 2006 Otto Aufranc Award Paper
    • [No. 443]
    • Kurtz S.M., Hozack W.J., Purtill J.J., Marcolongo M., Kraay M.J., Goldberg V.M., et al. Significance of in vivo degradation for polyethylene in total hip arthroplasty - the 2006 Otto Aufranc Award Paper. Clin Orth Relat Res 2006, 47-57. [No. 443].
    • (2006) Clin Orth Relat Res , pp. 47-57
    • Kurtz, S.M.1    Hozack, W.J.2    Purtill, J.J.3    Marcolongo, M.4    Kraay, M.J.5    Goldberg, V.M.6
  • 19
    • 84879026026 scopus 로고    scopus 로고
    • ISO 14243-1:2002(E) - Implants for surgery - Wear of total knee-joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test
    • ISO 14243-1:2002(E) - Implants for surgery - Wear of total knee-joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test, 2002.
    • (2002)
  • 20
    • 0014619661 scopus 로고
    • Function of the knee joint in various activities
    • Morrison J.B. Function of the knee joint in various activities. Biomed Eng (NY) 1969, 4:573-580.
    • (1969) Biomed Eng (NY) , vol.4 , pp. 573-580
    • Morrison, J.B.1
  • 21
    • 0141924490 scopus 로고    scopus 로고
    • Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation
    • [No. 7]
    • Kurtz S.M., Hozack W., Marcolongo M., Turner J., Rimnac C., Edidin A. Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplasty 2003, 18(Suppl. 1):68-78. [No. 7].
    • (2003) J Arthroplasty , vol.18 , Issue.SUPPL. 1 , pp. 68-78
    • Kurtz, S.M.1    Hozack, W.2    Marcolongo, M.3    Turner, J.4    Rimnac, C.5    Edidin, A.6
  • 23
    • 84877599773 scopus 로고    scopus 로고
    • Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities
    • Schwiesau J, Schilling C, Kaddick C, Utzschneider S, Jansson V, Fritz B, Blömer W, Grupp TM. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities. Med Eng Phys, http://dx.doi.org/10.1016/j.medengphy.2012.07.003.
    • Med Eng Phys
    • Schwiesau, J.1    Schilling, C.2    Kaddick, C.3    Utzschneider, S.4    Jansson, V.5    Fritz, B.6    Blömer, W.7    Grupp, T.M.8
  • 24
    • 84879010558 scopus 로고    scopus 로고
    • ASTM F 2003-02 (Reapproved 2008) - Standard practice for accelerated aging of ultra-high molecular weight polyethylene after gamma irradiation in air
    • ASTM F 2003-02 (Reapproved 2008) - Standard practice for accelerated aging of ultra-high molecular weight polyethylene after gamma irradiation in air, 2008.
    • (2008)
  • 25
    • 84879011605 scopus 로고    scopus 로고
    • ISO 5834-4 2005(E) - Implants for surgery - ultra-high-molecular-weight polyethylene - Part 4: Oxidation index measurement method
    • ISO 5834-4 2005(E) - Implants for surgery - ultra-high-molecular-weight polyethylene - Part 4: Oxidation index measurement method, 2005.
    • (2005)
  • 26
    • 71649101993 scopus 로고    scopus 로고
    • Synovial fluid from patients with prosthetic joint arthroplasty - Protein concentration and in vivo wear of polyethylene
    • Noordin S., Schmalzried T.P., Campbell P.A., Amstutz H.C. Synovial fluid from patients with prosthetic joint arthroplasty - Protein concentration and in vivo wear of polyethylene. Orthop Trans 1997, 21:1022-1023.
    • (1997) Orthop Trans , vol.21 , pp. 1022-1023
    • Noordin, S.1    Schmalzried, T.P.2    Campbell, P.A.3    Amstutz, H.C.4
  • 28
    • 1642351728 scopus 로고    scopus 로고
    • Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty - correlation with flow properties
    • Mazzucco D., Scott R., Spector M. Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty - correlation with flow properties. Biomaterials 2004, 25:4433-4445.
    • (2004) Biomaterials , vol.25 , pp. 4433-4445
    • Mazzucco, D.1    Scott, R.2    Spector, M.3
  • 29
    • 84879021491 scopus 로고    scopus 로고
    • ISO 14243-2 2009(E) - Implants for surgery - Wear of total knee-joint prostheses - Part 2: Methods of Measurement
    • ISO 14243-2 2009(E) - Implants for surgery - Wear of total knee-joint prostheses - Part 2: Methods of Measurement, 2009.
    • (2009)
  • 30
    • 0033946299 scopus 로고    scopus 로고
    • Unicompartmental arthroplasty - results in Sweden 1986-1995
    • Robertsson O. Unicompartmental arthroplasty - results in Sweden 1986-1995. Orthopäde 2000, 29(Suppl. 1):S6-S8.
    • (2000) Orthopäde , vol.29 , Issue.SUPPL. 1
    • Robertsson, O.1
  • 31
    • 0141993060 scopus 로고    scopus 로고
    • Unicompartmental knee arthroplasty in patients sixty years of age or younger
    • Pennington D.W., Swienckowski J.J., Lutes W.B., Drake G.N. Unicompartmental knee arthroplasty in patients sixty years of age or younger. J Bone Joint Surg Am 2003, 85A(10):1968-1973.
    • (2003) J Bone Joint Surg Am , vol.85 A , Issue.10 , pp. 1968-1973
    • Pennington, D.W.1    Swienckowski, J.J.2    Lutes, W.B.3    Drake, G.N.4
  • 32
    • 33847736288 scopus 로고    scopus 로고
    • Failure mechanism after unicompartmental and tricompartmental primary knee replacement with cement
    • Furnes O., Espehaug B., Lie S.A., Vollset S.E., Engesaeter L.B., Havelin L. Failure mechanism after unicompartmental and tricompartmental primary knee replacement with cement. J Bone Joint Surg Am 2007, 89A(3):519-525.
    • (2007) J Bone Joint Surg Am , vol.89 A , Issue.3 , pp. 519-525
    • Furnes, O.1    Espehaug, B.2    Lie, S.A.3    Vollset, S.E.4    Engesaeter, L.B.5    Havelin, L.6
  • 34
    • 52049120412 scopus 로고    scopus 로고
    • Contemporary unicompartmental knee arthroplasty - fixed vs. mobile bearing
    • [No. 7, e2]
    • Bonutti P.M., Dethmers D.A. Contemporary unicompartmental knee arthroplasty - fixed vs. mobile bearing. J Arthroplasty 2008, 23(Suppl. 1):24-27. [No. 7, e2].
    • (2008) J Arthroplasty , vol.23 , Issue.SUPPL. 1 , pp. 24-27
    • Bonutti, P.M.1    Dethmers, D.A.2
  • 35
    • 0036897567 scopus 로고    scopus 로고
    • Modern unicompartmental knee arthroplasty with cement. A three to ten-year follow-up study
    • Argenson J.N.A., Chevrol-Benkeddache Y., Aubaniac J.M. Modern unicompartmental knee arthroplasty with cement. A three to ten-year follow-up study. J Bone Joint Surg Am 2002, 84A(12):2235-2239.
    • (2002) J Bone Joint Surg Am , vol.84 A , Issue.12 , pp. 2235-2239
    • Argenson, J.N.A.1    Chevrol-Benkeddache, Y.2    Aubaniac, J.M.3
  • 36
    • 33748766054 scopus 로고    scopus 로고
    • Survivorship of the St. Georg sled medial unicompartmental knee replacement beyond ten years
    • Steele R.G., Hutabarat S., Evans R.L., Ackroyd C.E., Newman J.H. Survivorship of the St. Georg sled medial unicompartmental knee replacement beyond ten years. J Bone Joint Surg 2006, 88B:1164-1168.
    • (2006) J Bone Joint Surg , vol.88 B , pp. 1164-1168
    • Steele, R.G.1    Hutabarat, S.2    Evans, R.L.3    Ackroyd, C.E.4    Newman, J.H.5
  • 39
    • 77956725438 scopus 로고    scopus 로고
    • Polyethylene stresses in unicompartmental knee replacements during a step-up activity: a comparison between a fixed and mobile bearing
    • Simpson D.J., Gill H.S. Polyethylene stresses in unicompartmental knee replacements during a step-up activity: a comparison between a fixed and mobile bearing. J Biomech 2007, 40(Suppl. 2):S59.
    • (2007) J Biomech , vol.40 , Issue.SUPPL. 2
    • Simpson, D.J.1    Gill, H.S.2
  • 40
    • 0022504260 scopus 로고
    • The problem of surface damage in polyethylene total knee components
    • [No. 205]
    • Wright T.M., Bartel D.L. The problem of surface damage in polyethylene total knee components. Clin Orthop Relat Res 1986, 67-74. [No. 205].
    • (1986) Clin Orthop Relat Res , pp. 67-74
    • Wright, T.M.1    Bartel, D.L.2
  • 41
    • 0042847853 scopus 로고
    • Ultra-high-molecular-weight-polyethylene
    • Churchill Livingstone, New York, F. Bernard, Morrey (Eds.)
    • Wright T.M., Rimnac C.M. Ultra-high-molecular-weight-polyethylene. Joint replacement arthroplasty 1991, 37-45. Churchill Livingstone, New York. F. Bernard, Morrey (Eds.).
    • (1991) Joint replacement arthroplasty , pp. 37-45
    • Wright, T.M.1    Rimnac, C.M.2
  • 42
    • 52049090195 scopus 로고    scopus 로고
    • Cross-linked polyethylene in total knee arthroplasty - in opposition
    • [No. 7]
    • Rodriguez J.A. Cross-linked polyethylene in total knee arthroplasty - in opposition. J Arthroplasty 2008, 23(Suppl. 1):31-34. [No. 7].
    • (2008) J Arthroplasty , vol.23 , Issue.SUPPL. 1 , pp. 31-34
    • Rodriguez, J.A.1
  • 43
    • 77956752722 scopus 로고    scopus 로고
    • Correlation of knee simulation to in vivo use: evaluating the Oxford unicompartmental knee
    • Schroeder D
    • Scott E., Schroeder D Correlation of knee simulation to in vivo use: evaluating the Oxford unicompartmental knee. 46th Annual meeting orthopaedic research society 2000.
    • (2000) 46th Annual meeting orthopaedic research society
    • Scott, E.1
  • 45
    • 78650722759 scopus 로고    scopus 로고
    • Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study
    • Kretzer J.P., Jakubowitz E., Reinders J., Lietz E., Moradi B., Hofmann K., et al. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study. Acta Biomater 2011, 7:710-715.
    • (2011) Acta Biomater , vol.7 , pp. 710-715
    • Kretzer, J.P.1    Jakubowitz, E.2    Reinders, J.3    Lietz, E.4    Moradi, B.5    Hofmann, K.6
  • 46
    • 79961149577 scopus 로고    scopus 로고
    • The wear of fixed and mobile bearing unicompartmental knee replacements
    • Brockett C.L., Jennings L.M., Fisher J. The wear of fixed and mobile bearing unicompartmental knee replacements. Proc Inst Mech Engrs Part H 2011, 225(6):511-519.
    • (2011) Proc Inst Mech Engrs Part H , vol.225 , Issue.6 , pp. 511-519
    • Brockett, C.L.1    Jennings, L.M.2    Fisher, J.3
  • 47
    • 0031734854 scopus 로고    scopus 로고
    • Wear of congruent meniscal bearings in unicompartmental knee arthroplasty
    • Psychoyios V., Crawford R.W., O'Connor J.J., Murray D.W. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty. J Bone Joint Surg Br 1998, 80B(6):976-982.
    • (1998) J Bone Joint Surg Br , vol.80 B , Issue.6 , pp. 976-982
    • Psychoyios, V.1    Crawford, R.W.2    O'Connor, J.J.3    Murray, D.W.4
  • 48
    • 2942543100 scopus 로고    scopus 로고
    • Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis
    • Ashraf T., Newman J.H., Desai V.V., Beard D., Nevelos J.E. Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis. Knee 2004, 11:177-181.
    • (2004) Knee , vol.11 , pp. 177-181
    • Ashraf, T.1    Newman, J.H.2    Desai, V.V.3    Beard, D.4    Nevelos, J.E.5
  • 49
    • 77956777003 scopus 로고    scopus 로고
    • Biotribology of alternative bearing materials for unicompartmental knee arthroplasty
    • Grupp T.M., Utzschneider S., Schröder C., Schwiesau J., Fritz B., Maas A., et al. Biotribology of alternative bearing materials for unicompartmental knee arthroplasty. Acta Biomater 2010, 6:3601-3610.
    • (2010) Acta Biomater , vol.6 , pp. 3601-3610
    • Grupp, T.M.1    Utzschneider, S.2    Schröder, C.3    Schwiesau, J.4    Fritz, B.5    Maas, A.6
  • 51
    • 0036903452 scopus 로고    scopus 로고
    • In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty
    • Argenson J.N.A., Komistek R.D., Aubaniac J.M., Dennis D.A., Northcut E.J., Anderson D.T., et al. In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplasty 2002, 17(8):1049-1054.
    • (2002) J Arthroplasty , vol.17 , Issue.8 , pp. 1049-1054
    • Argenson, J.N.A.1    Komistek, R.D.2    Aubaniac, J.M.3    Dennis, D.A.4    Northcut, E.J.5    Anderson, D.T.6
  • 52
    • 0026655386 scopus 로고
    • Polyethylene wear in unicondylar knee prostheses - 106 retrieved Marmor, PCA and St. Georg tibial components compared
    • Blunn G.W., Joshi A.B., Lilley P.A., Engelbrecht E., Ryd L., Lidgren L., et al. Polyethylene wear in unicondylar knee prostheses - 106 retrieved Marmor, PCA and St. Georg tibial components compared. Acta Orthop Scand 1992, 63(3):247-255.
    • (1992) Acta Orthop Scand , vol.63 , Issue.3 , pp. 247-255
    • Blunn, G.W.1    Joshi, A.B.2    Lilley, P.A.3    Engelbrecht, E.4    Ryd, L.5    Lidgren, L.6
  • 53
    • 0033922918 scopus 로고    scopus 로고
    • Effect of resin type and manufacturing method on wear of polyethylene tibial components
    • No.376
    • Won C.H., Rohatgi S., Kraay M.J., Goldberg V.M., Rimnac C.M. Effect of resin type and manufacturing method on wear of polyethylene tibial components. Clin Orth Relat Res 2000, 161-171. No.376.
    • (2000) Clin Orth Relat Res , pp. 161-171
    • Won, C.H.1    Rohatgi, S.2    Kraay, M.J.3    Goldberg, V.M.4    Rimnac, C.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.