메뉴 건너뛰기




Volumn 35, Issue 5, 2013, Pages 591-600

Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities

Author keywords

High demanding activities; Simulator performance; Test method; Wear simulation

Indexed keywords

ACCURACY AND PRECISION; ACTIVITIES OF DAILY LIVING; ANTERIOR POSTERIORS; HIGH DEMANDING ACTIVITIES; PATIENT ACTIVITIES; TEST METHOD; TOTAL KNEE ARTHROPLASTY; WEAR SIMULATION;

EID: 84877599773     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2012.07.003     Document Type: Article
Times cited : (39)

References (57)
  • 1
    • 0031059923 scopus 로고    scopus 로고
    • A knee simulating machine for performance evaluation of total knee replacements
    • Walker P.S., Blunn G.W., Broome D.R., Perry J., Watkins A., Sathasivam S., et al. A knee simulating machine for performance evaluation of total knee replacements. J Biomech 1997, 30(1):83-89.
    • (1997) J Biomech , vol.30 , Issue.1 , pp. 83-89
    • Walker, P.S.1    Blunn, G.W.2    Broome, D.R.3    Perry, J.4    Watkins, A.5    Sathasivam, S.6
  • 2
    • 0034308356 scopus 로고    scopus 로고
    • The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
    • DesJardins J.D., Walker P.S., Haider H., Perry J. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. J Biomech 2000, 33:1231-1242.
    • (2000) J Biomech , vol.33 , pp. 1231-1242
    • DesJardins, J.D.1    Walker, P.S.2    Haider, H.3    Perry, J.4
  • 3
    • 0014619661 scopus 로고
    • Function of the knee joint in various activities
    • Morrison J.B. Function of the knee joint in various activities. Biomed Eng 1969, 4:573-580.
    • (1969) Biomed Eng , vol.4 , pp. 573-580
    • Morrison, J.B.1
  • 4
    • 0014698584 scopus 로고
    • The mechanics of the knee joint in relation to normal walking
    • Morrison J.B. The mechanics of the knee joint in relation to normal walking. J Biomech 1970, 3:51-61.
    • (1970) J Biomech , vol.3 , pp. 51-61
    • Morrison, J.B.1
  • 5
    • 0000519766 scopus 로고
    • Bioengineering analysis of force actions transmitting by the knee joint
    • Morrison J.B. Bioengineering analysis of force actions transmitting by the knee joint. Biomed Eng 1968, 3:166-170.
    • (1968) Biomed Eng , vol.3 , pp. 166-170
    • Morrison, J.B.1
  • 8
    • 10444261188 scopus 로고    scopus 로고
    • The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    • McEwen H.M.J., Barnett P.I., Bell C.J., Farrar R., Auger D.D., Stone M.H., et al. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech 2005, 38:357-365.
    • (2005) J Biomech , vol.38 , pp. 357-365
    • McEwen, H.M.J.1    Barnett, P.I.2    Bell, C.J.3    Farrar, R.4    Auger, D.D.5    Stone, M.H.6
  • 9
    • 58649111026 scopus 로고    scopus 로고
    • Fixed and mobile bearing total knee arthroplasty - influence on wear generation, corresponding wear areas, knee kinematics and particle composition
    • Grupp T.M., Kaddick C., Schwiesau J., Maas A., Stulberg S.D. Fixed and mobile bearing total knee arthroplasty - influence on wear generation, corresponding wear areas, knee kinematics and particle composition. Clin Biomech 2009, 24:210-217.
    • (2009) Clin Biomech , vol.24 , pp. 210-217
    • Grupp, T.M.1    Kaddick, C.2    Schwiesau, J.3    Maas, A.4    Stulberg, S.D.5
  • 10
    • 84877630497 scopus 로고    scopus 로고
    • ISO 14243-1:2002(E) - Implants for surgery - wear of total knee-joint prostheses - part 1: loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test
    • ISO 14243-1:2002(E) - Implants for surgery - wear of total knee-joint prostheses - part 1: loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test; 2002.
    • (2002)
  • 11
    • 84877616531 scopus 로고    scopus 로고
    • ISO 14243-3:2004(E) - implants for surgery - wear of total knee-joint prostheses - part 3: loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test
    • ISO 14243-3:2004(E) - implants for surgery - wear of total knee-joint prostheses - part 3: loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test; 2004.
    • (2004)
  • 12
    • 0034988888 scopus 로고    scopus 로고
    • Forces and moments telemetered from two distal femoral replacements during various activities
    • Taylor S.J.G., Walker P.S. Forces and moments telemetered from two distal femoral replacements during various activities. J Biomech 2001, 34:839-848.
    • (2001) J Biomech , vol.34 , pp. 839-848
    • Taylor, S.J.G.1    Walker, P.S.2
  • 13
    • 34248335488 scopus 로고    scopus 로고
    • In vivo medial and lateral tibial loads during dynamic and high flexion activities
    • Zhao D., Banks S.A., D'Lima D.D., Colwell C.W., Fregly B.J. In vivo medial and lateral tibial loads during dynamic and high flexion activities. J Orthop Res 2007, 25(5):593-602.
    • (2007) J Orthop Res , vol.25 , Issue.5 , pp. 593-602
    • Zhao, D.1    Banks, S.A.2    D'Lima, D.D.3    Colwell, C.W.4    Fregly, B.J.5
  • 14
    • 62949229183 scopus 로고    scopus 로고
    • Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10months. ESB Clinical Biomechanics Award 2008
    • Heinlein B., Kutzner I., Graichen F., Bender A., Rohlmann A., Halder A., et al. Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10months. ESB Clinical Biomechanics Award 2008. Clin Biomech 2009, 24(4):315-326.
    • (2009) Clin Biomech , vol.24 , Issue.4 , pp. 315-326
    • Heinlein, B.1    Kutzner, I.2    Graichen, F.3    Bender, A.4    Rohlmann, A.5    Halder, A.6
  • 16
    • 84872617075 scopus 로고    scopus 로고
    • Wear of the tibial polyethylene component in total knee replacements - the significance of sliding velocity during gait
    • Schwenke, T. Wear of the tibial polyethylene component in total knee replacements - the significance of sliding velocity during gait. Dissertation TU Hamburg-Harburg Shaker Verlag Aachen; 2009.
    • (2009) Dissertation TU Hamburg-Harburg Shaker Verlag Aachen
    • Schwenke, T.1
  • 17
    • 0031924955 scopus 로고    scopus 로고
    • Effect of oxidation of delamination of ultrahigh-molecular-weight polyethylene tibial components
    • Bell C.J., Walker P.S., Abeysundera M.R., Simmons J.M.H., King P.M., Blunn G.W. Effect of oxidation of delamination of ultrahigh-molecular-weight polyethylene tibial components. J Arthroplasty 1998, 13(3):280-290.
    • (1998) J Arthroplasty , vol.13 , Issue.3 , pp. 280-290
    • Bell, C.J.1    Walker, P.S.2    Abeysundera, M.R.3    Simmons, J.M.H.4    King, P.M.5    Blunn, G.W.6
  • 18
    • 8644226074 scopus 로고    scopus 로고
    • Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee replacements - the Coventry Award Paper
    • Fehring T.K., Murphy J.A., Hayes T.D., Roberts D.W., Pomeroy D.L., Griffin W.L. Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee replacements - the Coventry Award Paper. Clin Orth Rel Res 2004, 428:40-50.
    • (2004) Clin Orth Rel Res , vol.428 , pp. 40-50
    • Fehring, T.K.1    Murphy, J.A.2    Hayes, T.D.3    Roberts, D.W.4    Pomeroy, D.L.5    Griffin, W.L.6
  • 19
    • 34547646937 scopus 로고    scopus 로고
    • Unilateral tibial polyethylene liner failure in bilateral total knee arthroplasty - bilateral retrieval analysis at 8years
    • Burnett R.S.J., Biggerstaff S., Currier B.H., Collier J.P., Barrack R.L. Unilateral tibial polyethylene liner failure in bilateral total knee arthroplasty - bilateral retrieval analysis at 8years. J Arthroplasty 2007, 22(5):753-758.
    • (2007) J Arthroplasty , vol.22 , Issue.5 , pp. 753-758
    • Burnett, R.S.J.1    Biggerstaff, S.2    Currier, B.H.3    Collier, J.P.4    Barrack, R.L.5
  • 20
    • 65649122605 scopus 로고    scopus 로고
    • Premature failure of Kinemax Plus total knee replacements
    • Reay E., Wu J., Holland J., Deehan D. Premature failure of Kinemax Plus total knee replacements. J Bone Joint Surg 2009, 91B(5):604-611.
    • (2009) J Bone Joint Surg , vol.91 B , Issue.5 , pp. 604-611
    • Reay, E.1    Wu, J.2    Holland, J.3    Deehan, D.4
  • 23
  • 26
    • 0020116475 scopus 로고
    • Forces during squatting and rising from a deep squat
    • Dahlkvist N.J., Mayo P., Seedhom B.B. Forces during squatting and rising from a deep squat. Eng Med 1982, 11(2):69-76.
    • (1982) Eng Med , vol.11 , Issue.2 , pp. 69-76
    • Dahlkvist, N.J.1    Mayo, P.2    Seedhom, B.B.3
  • 30
    • 0021412481 scopus 로고
    • Forces in the knee joint whilst rising from a seated position
    • Ellis M.I., Seedhom B.B., Wright V. Forces in the knee joint whilst rising from a seated position. J Biomed Eng 1984, 6(2):113-120.
    • (1984) J Biomed Eng , vol.6 , Issue.2 , pp. 113-120
    • Ellis, M.I.1    Seedhom, B.B.2    Wright, V.3
  • 31
    • 0023764557 scopus 로고
    • An integrated biomechanical analysis of normal stair ascent and descent
    • McFayden B.J., Winter D.A. An integrated biomechanical analysis of normal stair ascent and descent. J Biomech 1988, 21(9):733-744.
    • (1988) J Biomech , vol.21 , Issue.9 , pp. 733-744
    • McFayden, B.J.1    Winter, D.A.2
  • 34
    • 0003047036 scopus 로고    scopus 로고
    • Musculoskeletal dynamics, locomotion, and clinical applications
    • Lippincott-Raven, Philadelphia, C. Van, C. Wilson (Eds.)
    • Andriacchi T.P., Natarajan R.N., Hurwitz D.E. Musculoskeletal dynamics, locomotion, and clinical applications. Basic orthopaedic biomechanics 1997, 37-68. Lippincott-Raven, Philadelphia. 2nd ed. C. Van, C. Wilson (Eds.).
    • (1997) Basic orthopaedic biomechanics , pp. 37-68
    • Andriacchi, T.P.1    Natarajan, R.N.2    Hurwitz, D.E.3
  • 35
    • 79960660533 scopus 로고    scopus 로고
    • TKA wear testing input after kinematic and dynamic meta-analysis: technique and proof of concept
    • Franta L., Kronek J., Suchánek J. TKA wear testing input after kinematic and dynamic meta-analysis: technique and proof of concept. Wear 2011, 271:2687-2692.
    • (2011) Wear , vol.271 , pp. 2687-2692
    • Franta, L.1    Kronek, J.2    Suchánek, J.3
  • 36
    • 0015569382 scopus 로고
    • Wear of solid phase formed high density polyethylene in relation to the life of artificial hips and knees
    • Seedhom B.B., Dowson D., Wright V. Wear of solid phase formed high density polyethylene in relation to the life of artificial hips and knees. Wear 1973, 24:35-51.
    • (1973) Wear , vol.24 , pp. 35-51
    • Seedhom, B.B.1    Dowson, D.2    Wright, V.3
  • 37
    • 0028805779 scopus 로고
    • Physical activity assessment using a pedometer and its comparison with a questionaire in a large population survey
    • Sequeira M.M., Rickenbach M., Wietlisbach V., Tullen B., Schutz Y. Physical activity assessment using a pedometer and its comparison with a questionaire in a large population survey. Am J Epidemiol 1995, 142(9):989-999.
    • (1995) Am J Epidemiol , vol.142 , Issue.9 , pp. 989-999
    • Sequeira, M.M.1    Rickenbach, M.2    Wietlisbach, V.3    Tullen, B.4    Schutz, Y.5
  • 38
  • 40
    • 0022395089 scopus 로고
    • Walking activities and wear of prostheses
    • Seedhom B.B., Wallbridge N.C. Walking activities and wear of prostheses. Ann Rheum Dis 1985, 44(12):838-843.
    • (1985) Ann Rheum Dis , vol.44 , Issue.12 , pp. 838-843
    • Seedhom, B.B.1    Wallbridge, N.C.2
  • 45
    • 77955275024 scopus 로고    scopus 로고
    • Loading of the knee joint during activities of daily living measured in vivo in five subjects
    • Kutzner I., Heinlein B., Graichen F., Bender A., Rohlmann A., Halder A., et al. Loading of the knee joint during activities of daily living measured in vivo in five subjects. J Biomech 2010, 43:2164-2173.
    • (2010) J Biomech , vol.43 , pp. 2164-2173
    • Kutzner, I.1    Heinlein, B.2    Graichen, F.3    Bender, A.4    Rohlmann, A.5    Halder, A.6
  • 46
    • 49149114515 scopus 로고    scopus 로고
    • In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement
    • Muendermann A., Dyrby C.O., d'Lima D.D., Colwell C.W., Andriacchi T.P. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. J Orthop Res 2008, 26(9):1167-1172.
    • (2008) J Orthop Res , vol.26 , Issue.9 , pp. 1167-1172
    • Muendermann, A.1    Dyrby, C.O.2    d'Lima, D.D.3    Colwell, C.W.4    Andriacchi, T.P.5
  • 47
    • 34249932507 scopus 로고    scopus 로고
    • In vivo knee moments and shear after total knee arthroplasty
    • d'Lima D.D., Patil S., Steklov N., Chien S., Colwell C.W. In vivo knee moments and shear after total knee arthroplasty. J Biomech 2007, 44(Suppl. 1):S11-S17.
    • (2007) J Biomech , vol.44 , Issue.SUPPL. 1
    • d'Lima, D.D.1    Patil, S.2    Steklov, N.3    Chien, S.4    Colwell, C.W.5
  • 50
    • 77955269220 scopus 로고    scopus 로고
    • In vitro response of the natural cadaver knee to the loading profiles specified in a standard for knee implant wear testing
    • Sutton L.G., Werner F.W., Haider A., Hamblin T., Clabeaux J.J. In vitro response of the natural cadaver knee to the loading profiles specified in a standard for knee implant wear testing. J Biomech 2010, 43(11):2203-2207.
    • (2010) J Biomech , vol.43 , Issue.11 , pp. 2203-2207
    • Sutton, L.G.1    Werner, F.W.2    Haider, A.3    Hamblin, T.4    Clabeaux, J.J.5
  • 51
    • 77954821317 scopus 로고    scopus 로고
    • Bi-unicondylar knee prosthesis functional assessment utilizing force-control wear testing
    • Spinelli M., Affatato S., Harman M.K., DesJardins J.D. Bi-unicondylar knee prosthesis functional assessment utilizing force-control wear testing. Proc Inst Mech Eng Part H 2010, 224(7):813-821.
    • (2010) Proc Inst Mech Eng Part H , vol.224 , Issue.7 , pp. 813-821
    • Spinelli, M.1    Affatato, S.2    Harman, M.K.3    DesJardins, J.D.4
  • 52
    • 79551657626 scopus 로고    scopus 로고
    • Reduction of total knee replacement wear with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene
    • Vaidya C., Alvarez E., Vinciguerra J., Bruce D.A., DesJardins J.D. Reduction of total knee replacement wear with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene. Proc Inst Mech Eng Part H 2011, 225(1):1-7.
    • (2011) Proc Inst Mech Eng Part H , vol.225 , Issue.1 , pp. 1-7
    • Vaidya, C.1    Alvarez, E.2    Vinciguerra, J.3    Bruce, D.A.4    DesJardins, J.D.5
  • 53
    • 0034806870 scopus 로고    scopus 로고
    • Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics
    • Benson L.C., DesJardins J.D., LaBerge M. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics. J Biomed Mater Res 2001, 58(5):496-504.
    • (2001) J Biomed Mater Res , vol.58 , Issue.5 , pp. 496-504
    • Benson, L.C.1    DesJardins, J.D.2    LaBerge, M.3
  • 54
    • 34248191184 scopus 로고    scopus 로고
    • Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control
    • Haider H., Walker P., DesJardins J., Blunn G. Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control. J ASTM Int 2006, 3(10):3-17.
    • (2006) J ASTM Int , vol.3 , Issue.10 , pp. 3-17
    • Haider, H.1    Walker, P.2    DesJardins, J.3    Blunn, G.4
  • 56
    • 0036903452 scopus 로고    scopus 로고
    • In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty
    • Argenson J.N.A., Komistek R.D., Aubaniac J.M., Dennis D.A., Northcut E.J., Anderson D.T., et al. In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplasty 2002, 17(8):1049-1054.
    • (2002) J Arthroplasty , vol.17 , Issue.8 , pp. 1049-1054
    • Argenson, J.N.A.1    Komistek, R.D.2    Aubaniac, J.M.3    Dennis, D.A.4    Northcut, E.J.5    Anderson, D.T.6
  • 57
    • 77952542558 scopus 로고    scopus 로고
    • Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation
    • Harman M.K., Schmitt S., Rössing S., Banks S.A., Scharf H.P., Viceconti M., et al. Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation. Clin Biomech 2010, 25:570-575.
    • (2010) Clin Biomech , vol.25 , pp. 570-575
    • Harman, M.K.1    Schmitt, S.2    Rössing, S.3    Banks, S.A.4    Scharf, H.P.5    Viceconti, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.