메뉴 건너뛰기




Volumn 26, Issue 3, 2013, Pages 302-309

Aortic annulus measurement and relevance to successful transcatheter aortic valve replacement: A new technique using 3D TEE

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMY; AORTA ANNULUS; AORTA ROOT; ARTICLE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; DIAGNOSTIC ACCURACY; ELECTROCARDIOGRAM; GOLD STANDARD; HUMAN; MEASUREMENT; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; PROCEDURES; RADIODIAGNOSIS; RISK BENEFIT ANALYSIS; SYSTOLE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84879012206     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/joic.12033     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 78649669798 scopus 로고    scopus 로고
    • Aortic annulus evaluation in transcatheter aortic valve implantation
    • Hutter A, Opitz A, Bleiziffer S, et al. Aortic annulus evaluation in transcatheter aortic valve implantation. Cath Cardiovasc Inter 2010; 76: 1009-1019.
    • (2010) Cath Cardiovasc Inter , vol.76 , pp. 1009-1019
    • Hutter, A.1    Opitz, A.2    Bleiziffer, S.3
  • 2
    • 83955161782 scopus 로고    scopus 로고
    • Role of computed tomography imaging for transcatheter valvular repair/insertion
    • Ewe SH, Klautz RJ, Schalij M, et al. Role of computed tomography imaging for transcatheter valvular repair/insertion. Int J Cardiovasc Imaging 2011; 27: 1179-1193.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 1179-1193
    • Ewe, S.H.1    Klautz, R.J.2    Schalij, M.3
  • 3
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • Jilaihawi H, Kashif M, Fontana G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 2012; 59: 1275-1286.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3
  • 4
    • 78449265988 scopus 로고    scopus 로고
    • Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation
    • Gurvitch R, Wood DA, Leipsic J, et al. Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. J Am Coll Cardiol Cardiovasc Interv 2010; 3: 1157-1165.
    • (2010) J Am Coll Cardiol Cardiovasc Interv , vol.3 , pp. 1157-1165
    • Gurvitch, R.1    Wood, D.A.2    Leipsic, J.3
  • 5
    • 69949131787 scopus 로고    scopus 로고
    • The evolving role of MDCT in transcatheter aortic valve replacement: A radiologists' perspective
    • Leipsic J, Wood D, Manders D, et al. The evolving role of MDCT in transcatheter aortic valve replacement: A radiologists' perspective. Am J Roentgenol 2009; 193: W214-W219.
    • (2009) Am J Roentgenol , vol.193
    • Leipsic, J.1    Wood, D.2    Manders, D.3
  • 6
    • 70349899313 scopus 로고    scopus 로고
    • CT angiography of the cardiac valves: Normal, diseased, and postoperative appearances
    • Chen JJ, Manning MA, Frazier A, et al. CT angiography of the cardiac valves: Normal, diseased, and postoperative appearances. Radiographics 2009; 29: 1393-1412.
    • (2009) Radiographics , vol.29 , pp. 1393-1412
    • Chen, J.J.1    Manning, M.A.2    Frazier, A.3
  • 7
    • 84870541288 scopus 로고    scopus 로고
    • Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: Differences between systole and diastole
    • Bertaso AG, Wong DT, Liew GY, et al. Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: Differences between systole and diastole. Int J Cardiovasc Imaging 2012; 28 (8): 2091-2098.
    • (2012) Int J Cardiovasc Imaging , vol.28 , Issue.8 , pp. 2091-2098
    • Bertaso, A.G.1    Wong, D.T.2    Liew, G.Y.3
  • 8
    • 79954492455 scopus 로고    scopus 로고
    • Multidetector computed tomography in transcatheter aortic valve implantation
    • Leipsic J, Gurvitch R, Labounty TM, et al. Multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Cardiovasc Imaging 2011; 4: 416-429.
    • (2011) J Am Coll Cardiol Cardiovasc Imaging , vol.4 , pp. 416-429
    • Leipsic, J.1    Gurvitch, R.2    Labounty, T.M.3
  • 9
    • 81855227692 scopus 로고    scopus 로고
    • Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation
    • Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Cardiovasc Interv 2011; 4: 1235-1245.
    • (2011) J Am Coll Cardiol Cardiovasc Interv , vol.4 , pp. 1235-1245
    • Gurvitch, R.1    Webb, J.G.2    Yuan, R.3
  • 10
    • 77951718294 scopus 로고    scopus 로고
    • Paravalvular regurgitation 1 year transcatheter aortic valve implantation
    • Rajani R, Kakad M, Khwaja MZ, et al. Paravalvular regurgitation 1 year transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2010; 75: 868-872.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 868-872
    • Rajani, R.1    Kakad, M.2    Khwaja, M.Z.3
  • 11
    • 84864215288 scopus 로고    scopus 로고
    • Aortic annulus sizing: Echocardiographic versus CT derived measurements in comparison with direct aortic sizing
    • Kempfert J, Van Linden A, Lehmkuhl L, et al. Aortic annulus sizing: Echocardiographic versus CT derived measurements in comparison with direct aortic sizing. Eur J Cardio-Thoracic Surg 2012; 42 (4): 627-633.
    • (2012) Eur J Cardio-Thoracic Surg , vol.42 , Issue.4 , pp. 627-633
    • Kempfert, J.1    Van Linden, A.2    Lehmkuhl, L.3
  • 12
    • 79955470195 scopus 로고    scopus 로고
    • Assessment of the aortic annulus by MSCT, contrast aortography and TTE in patients referred for transcatheter aortic valve implantation
    • Tzikas A, Schultz C, Piazza N, et al. Assessment of the aortic annulus by MSCT, contrast aortography and TTE in patients referred for transcatheter aortic valve implantation. Cath Cardiovasc Interv 2011; 77: 868-875.
    • (2011) Cath Cardiovasc Interv , vol.77 , pp. 868-875
    • Tzikas, A.1    Schultz, C.2    Piazza, N.3
  • 13
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter
    • Messika-Zeitoun D, Serfaty J, Brochet E, et al. Multimodal assessment of the aortic annulus diameter. J Am Coll Cardiol 2010; 55: 186-194.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 186-194
    • Messika-Zeitoun, D.1    Serfaty, J.2    Brochet, E.3
  • 14
    • 79952980048 scopus 로고    scopus 로고
    • Measurement of the aortic annulus size by real time 3D TEE
    • Janosi R, Kahlert P, Plicht B, et al. Measurement of the aortic annulus size by real time 3D TEE. Minim Invasive Ther 2011; 20: 85-94.
    • (2011) Minim Invasive Ther , vol.20 , pp. 85-94
    • Janosi, R.1    Kahlert, P.2    Plicht, B.3
  • 15
    • 84869494217 scopus 로고    scopus 로고
    • Impact of 3D TEE on prosthesis sizing for transcatheter aortic valve implantation
    • Husser O, Rauch S, Endemann D, et al. Impact of 3D TEE on prosthesis sizing for transcatheter aortic valve implantation. Cath Cardiovasc Interv 2012; 80 (6): 956-963.
    • (2012) Cath Cardiovasc Interv , vol.80 , Issue.6 , pp. 956-963
    • Husser, O.1    Rauch, S.2    Endemann, D.3
  • 16
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • Ng ACT, Delgado V, van der Kley., Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 2010; 3: 94-102.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.T.1    Delgado, V.2    Van Der, Kley.3
  • 17
    • 79955891681 scopus 로고    scopus 로고
    • German transcatheter aortic valve interventions registry investigators. Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome
    • Abdel-Wahab M, Zahn R, Horack M, et al. German transcatheter aortic valve interventions registry investigators. Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Heart 2011; 97: 899-906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 18
    • 84867515040 scopus 로고    scopus 로고
    • Prosthesis/annular discongruence assessed by 3D TEE: A predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation
    • Santos N, deAugustin J, Almeria C, et al. Prosthesis/annular discongruence assessed by 3D TEE: A predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 2012; 13 (11): 931-937.
    • (2012) Eur Heart J Cardiovasc Imaging , vol.13 , Issue.11 , pp. 931-937
    • Santos, N.1    Deaugustin, J.2    Almeria, C.3
  • 19
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after TAVI
    • Detaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after TAVI. J Am Coll Cardiol Intv 2009; 2: 821-827.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 20
    • 84879014604 scopus 로고    scopus 로고
    • CT based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation
    • Buzzatti N, Maisano F, Latib A, et al. CT based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation. Eur J Cardiothorac Surg 2013; 43 (1): 43-50.
    • (2013) Eur J Cardiothorac Surg , vol.43 , Issue.1 , pp. 43-50
    • Buzzatti, N.1    Maisano, F.2    Latib, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.