Volumn 61, Issue 5, 2013, Pages 2170-2176

Analysis of electromagnetic fields induced in operation of a wireless fully passive backscattering neurorecording microsystem in emulated human head tissue

Author keywords

Backscattering; brain machine interfaces; implantable electronics; microelectromechanical systems (MEMS); passive devices; specific absorption rate (SAR)

Indexed keywords

BRAIN MACHINE INTERFACE; IMPLANTABLE ELECTRONICS; MICRO ELECTROMECHANICAL SYSTEM (MEMS); PASSIVE DEVICES; SPECIFIC ABSORPTION RATE;

EID: 84877749053     PISSN: 00189480     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMTT.2013.2252916     Document Type: Article
Times cited : (24)

References (29)
  • 2
    • 58149333214 scopus 로고    scopus 로고
    • Advanced neurotechnologies for chronic neural interfaces: New horizons and clinical opportunities
    • Nov
    • D. R. Kipke, W. Shain, G. Buzsáki, E. Fetz, J. M. Henderson, J. F. Hetke, and G. Schalk, "Advanced neurotechnologies for chronic neural interfaces: New horizons and clinical opportunities," J. Neurosci., vol. 28, no. 46, pp. 11830-11838, Nov. 2008.
    • (2008) J. Neurosci , vol.28 , Issue.46 , pp. 11830-11838
    • Kipke, D.R.1    Shain, W.2    Buzsáki, G.3    Fetz, E.4    Henderson, J.M.5    Hetke, J.F.6    Schalk, G.7
  • 5
    • 77950319551 scopus 로고    scopus 로고
    • Microelectrodes, microelectronics, and implantable neural microsystems
    • Jul
    • K. D. Wise, A. M. Sodagar, Y. Yao, M. N. Gulari, G. E. Perlin, and K. Najafi, "Microelectrodes, microelectronics, and implantable neural microsystems," Proc. IEEE, vol. 96, no. 7, pp. 1184-1202, Jul. 2008.
    • (2008) Proc IEEE , vol.96 , Issue.7 , pp. 1184-1202
    • Wise, K.D.1    Sodagar, A.M.2    Yao, Y.3    Gulari, M.N.4    Perlin, G.E.5    Najafi, K.6
  • 6
    • 79955629423 scopus 로고    scopus 로고
    • Biocompatibility of intracortical microelectrodes: Current status and future prospects
    • May
    • C. Marin and E. Fernández, "Biocompatibility of intracortical microelectrodes: Current status and future prospects," Frontiers in Neuroeng., vol. 3, no. 8, pp. 1-6, May 2010.
    • (2010) Frontiers in Neuroeng , vol.3 , Issue.8 , pp. 1-6
    • Marin, C.1    Fernández, E.2
  • 7
    • 67649670105 scopus 로고    scopus 로고
    • Toward a comparison of microelectrodes for acute and chronic recordings
    • May
    • M. P. Ward, P. Rajdev, C. Ellison, and P. P. Irazoqui, "Toward a comparison of microelectrodes for acute and chronic recordings," Brain Res., vol. 1282, pp. 183-200, May 2009.
    • (2009) Brain Res , vol.1282 , pp. 183-200
    • Ward, M.P.1    Rajdev, P.2    Ellison, C.3    Irazoqui, P.P.4
  • 10
    • 79551600219 scopus 로고    scopus 로고
    • A high-quality-factor film bulk acoustic resonator in liquid for biosensing applications
    • Feb.
    • W. Xu, X. Zhang, S. Choi, and J. Chae, "A high-quality-factor film bulk acoustic resonator in liquid for biosensing applications," J. Microelectromech. Syst., vol. 20, no. 1, pp. 213-220, Feb. 2011.
    • (2011) J. Microelectromech. Syst , vol.20 , Issue.1 , pp. 213-220
    • Xu, W.1    Zhang, X.2    Choi, S.3    Chae, J.4
  • 11
    • 80053571396 scopus 로고    scopus 로고
    • A fully passive wireless microsystem for recording of neuropotentials using RF backscattering methods
    • Oct.
    • H. N. Schwerdt, W. Xu, S. Shekhar, A. Abbaspour-Tamijani, B. C. Towe, F. A. Miranda, and J. Chae, "A fully passive wireless microsystem for recording of neuropotentials using RF backscattering methods," J. Microelectromech. Syst., vol. 20, no. 5, pp. 1119-1130, Oct. 2011.
    • (2011) J. Microelectromech. Syst , vol.20 , Issue.5 , pp. 1119-1130
    • Schwerdt, H.N.1    Xu, W.2    Shekhar, S.3    Abbaspour-Tamijani, A.4    Towe, B.C.5    Miranda, F.A.6    Chae, J.7
  • 12
    • 69949173593 scopus 로고    scopus 로고
    • Reusable biosensors via in situ electrochemical surface regeneration in microfluidic applications
    • Oct
    • S. Choi and J. Chae, "Reusable biosensors via in situ electrochemical surface regeneration in microfluidic applications," Biosensors Bioelectron., vol. 25, no. 2, pp. 527-531, Oct. 2009.
    • (2009) Biosensors Bioelectron , vol.25 , Issue.2 , pp. 527-531
    • Choi, S.1    Chae, J.2
  • 13
    • 58149347095 scopus 로고    scopus 로고
    • Miniaturized protein separation using a liquid chromatography column on a flexible substrate
    • Oct
    • Y. Yang and J. Chae, "Miniaturized protein separation using a liquid chromatography column on a flexible substrate," J. Micromech. Microeng., vol. 18, no. 12, Oct. 2008.
    • (2008) J. Micromech. Microeng , vol.18 , Issue.12
    • Yang, Y.1    Chae, J.2
  • 14
    • 80055061438 scopus 로고    scopus 로고
    • A wireless and passive wafer cleanliness monitoring unit via electromagnetic coupling for semiconductor/MEMS manufacturing facilities
    • Nov.
    • X. Zhang and J. Chae, "A wireless and passive wafer cleanliness monitoring unit via electromagnetic coupling for semiconductor/MEMS manufacturing facilities," Sens. Actuators A, Phys., vol. 171, no. 2, pp. 414-420, Nov. 2011.
    • (2011) Sens. Actuators A, Phys , vol.171 , Issue.2 , pp. 414-420
    • Zhang, X.1    Chae, J.2
  • 15
    • 84861659175 scopus 로고    scopus 로고
    • A fully passive wireless backscattering neuro-recording microsystem embedded in dispersive human head phantom medium
    • Jun.
    • H. N. Schwerdt, F. A. Miranda, and J. Chae, "A fully passive wireless backscattering neuro-recording microsystem embedded in dispersive human head phantom medium," IEEE Electron Device Lett., vol. 33, no. 6, pp. 908-910, Jun. 2012.
    • (2012) IEEE Electron Device Lett , vol.33 , Issue.6 , pp. 908-910
    • Schwerdt, H.N.1    Miranda, F.A.2    Chae, J.3
  • 16
    • 75149114610 scopus 로고    scopus 로고
    • Totally passive wireless biopotential measurement sensor by utilizing inductive coupled resonance circuits
    • Dec
    • J. Riistama, E. Aittokallio, J. Verho, and J. Lekkala, "Totally passive wireless biopotential measurement sensor by utilizing inductive coupled resonance circuits," Sens. Actuators A, Phys., vol. 157, pp. 313-321, Dec. 2009.
    • (2009) Sens. Actuators A, Phys , vol.157 , pp. 313-321
    • Riistama, J.1    Aittokallio, E.2    Verho, J.3    Lekkala, J.4
  • 17
    • 77955770333 scopus 로고    scopus 로고
    • Changes in electromagnetic field absorption in the presence of subcutaneous implanted devices: Minimizing increases in absorption
    • Aug.
    • N. Vidal and J. M. Lopez, "Changes in electromagnetic field absorption in the presence of subcutaneous implanted devices: Minimizing increases in absorption," IEEE Trans. Electromagn. Compat., vol. 52, no. 3, pp. 545-555, Aug. 2010.
    • (2010) IEEE Trans. Electromagn. Compat , vol.52 , Issue.3 , pp. 545-555
    • Vidal, N.1    Lopez, J.M.2
  • 18
    • 0024954610 scopus 로고
    • Stimulus-activated changes in brain tissue temperature in the anesthetized rat
    • J. C. LaManna, K. A. McCracken,M. Patil, and O. J. Prohaska, "Stimulus-activated changes in brain tissue temperature in the anesthetized rat," Metabolic Brain Disease, vol. 4, pp. 225-237, 1989. (Pubitemid 20091504)
    • (1989) Metabolic Brain Disease , vol.4 , Issue.4 , pp. 225-237
    • LaManna, J.C.1    McCracken, K.A.2    Patil, M.3    Prohaska, O.J.4
  • 20
    • 0003610612 scopus 로고    scopus 로고
    • Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields
    • D. L. Means andK. W. Chan, "Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields," FCC Office of Eng. Technol., Bull. 65, supplement C, 2001.
    • (2001) FCC Office of Eng. Technol., Bull , vol.65 , Issue.SUPPL. C
    • Means, D.L.1    Chan, K.W.2
  • 21
    • 0347101817 scopus 로고    scopus 로고
    • Effects of electromagnetic radiation of mobile phones on the central nervous system
    • DOI 10.1002/bem.10068
    • K.-A. Hossmann and D. M. Hermann, "Effects of electromagnetic radiation of mobile phones on the central nervous system," Bioelectromagn., vol. 24, no. 1, pp. 49-62, Jan. 2003. (Pubitemid 38622842)
    • (2003) Bioelectromagnetics , vol.24 , Issue.1 , pp. 49-62
    • Hossmann, K.-A.1    Hermann, D.M.2
  • 22
    • 84938011958 scopus 로고
    • Analyses of electromagnetic fields induced in biological tissues by thermographic studies on equivalent phantom models
    • Feb
    • A. W. Guy, "Analyses of electromagnetic fields induced in biological tissues by thermographic studies on equivalent phantom models," IEEE Trans. Microw. Theory Tech., vol. MTT-19, no. 2, pp. 205-214, Feb. 1971.
    • (1971) IEEE Trans. Microw. Theory Tech. , vol.MTT-19 , Issue.2 , pp. 205-214
    • Guy, A.W.1
  • 23
    • 0034314631 scopus 로고    scopus 로고
    • SAR evaluation method by a combination of thermographic experiments and biological tissue-equivalent phantoms
    • DOI 10.1109/22.884200
    • Y. Okano, K. Ito, I. Ida, and M. Takahashi, "The SAR evaluation method by a combination of thermographic experiments and biological tissue-equivalent phantoms," IEEE Trans. Microw. Theory Tech., vol. 48, no. 1, pp. 2094-2103, Nov. 2000. (Pubitemid 32076010)
    • (2000) IEEE Transactions on Microwave Theory and Techniques , vol.48 , Issue.II 11 , pp. 2094-2103
    • Okano, Y.1    Ito, K.2    Ida, I.3    Takahashi, M.4
  • 24
    • 0035121278 scopus 로고    scopus 로고
    • Development and characteristics of a biological tissue-equivalent phantom for microwaves
    • K. Ito, K. Furuya, Y. Okano, and L. Hamada, "Development and characteristics of a biological tissue-equivalent phantom for microwaves," Electron. Commun. Japan I, Commun., vol. 84, pp. 67-77, 2001.
    • (2001) Electron. Commun. Japan I, Commun , vol.84 , pp. 67-77
    • Ito, K.1    Furuya, K.2    Okano, Y.3    Hamada, L.4
  • 25
    • 77949857812 scopus 로고
    • Fundamental limitations of small antennas
    • Dec
    • H. A. Wheeler, "Fundamental limitations of small antennas," Proc. IRE, vol. 35, no. 12, pp. 1479-1484, Dec. 1947.
    • (1947) Proc. IRE , vol.35 , Issue.12 , pp. 1479-1484
    • Wheeler, H.A.1
  • 27
    • 0003870805 scopus 로고    scopus 로고
    • Compilation of the dielectric properties of body tissues at RF and microwave frequencies
    • Brooks AFB, TX, USA, Rep. N.AL/OE-TR-1996-0037 Jun
    • C. Gabriel, "Compilation of the dielectric properties of body tissues at RF and microwave frequencies," Occupational and Environmental Health Directorate, Radiofrequency Radiation Div., Brooks AFB, TX, USA, Rep. N.AL/OE-TR-1996-0037, Jun. 1996, .
    • (1996) Occupational and Environmental Health Directorate, Radiofrequency Radiation Div.
    • Gabriel, C.1
  • 28
    • 80053625568 scopus 로고    scopus 로고
    • Design, realization, and measurements of a miniature antenna for implantable wireless communication systems
    • Oct.
    • F. Merli, L. Bolomey, J.-F. Zürcher, G. Corradini, E. Meurville, and A. K. Skrivervik, "Design, realization, and measurements of a miniature antenna for implantable wireless communication systems," IEEE Trans. Antennas Prop., vol. 59, no. 10, pp. 3544-3555, Oct. 2011.
    • (2011) IEEE Trans. Antennas Prop , vol.59 , Issue.10 , pp. 3544-3555
    • Merli, F.1    Bolomey, L.2    Zürcher, J.-F.3    Corradini, G.4    Meurville, E.5    Skrivervik, A.K.6
  • 29
    • 79960148488 scopus 로고    scopus 로고
    • Rectenna application ofminiaturized implantable antenna design for triple-band biotelemetry communication
    • Jul.
    • F.-J. Huang, C.-M. Lee, C.-L. Chang, L.-K. Chen, T.-C. Yo, and C.-H. Luo, "Rectenna application ofminiaturized implantable antenna design for triple-band biotelemetry communication," IEEE Trans. Antennas Prop., vol. 59, no. 7, pp. 2646-2653, Jul. 2011.
    • (2011) IEEE Trans. Antennas Prop , vol.59 , Issue.7 , pp. 2646-2653
    • Huang, F.-J.1    Lee, C.-M.2    Chang, C.-L.3    Chen, L.-K.4    Yo, T.-C.5    Luo, C.-H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.