메뉴 건너뛰기




Volumn 44, Issue 6, 2013, Pages 751-756

High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate

Author keywords

Osteosynthesis; PF LCP; Proximal femoral fractures

Indexed keywords

ADULT; AGED; ARTICLE; BONE RADIOGRAPHY; BONE RESECTION; CLINICAL ASSESSMENT; COMPRESSION OSTEOSYNTHESIS; COMPRESSION PLATE; CONDYLAR PLATE; DEVICE REMOVAL; DISLOCATION; EMERGENCY HEALTH SERVICE; EQUIPMENT FAILURE; FEMALE; FEMUR SUBTROCHANTERIC FRACTURE; FOLLOW UP; FRACTURE DISLOCATION; HUMAN; LOCKING SCREW; MAJOR CLINICAL STUDY; MALE; OPEN REDUCTION; PEROPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSTHESIS FAILURE; RADIOLOGICAL PROCEDURES; TOTAL HIP PROSTHESIS; WEIGHT BEARING;

EID: 84877747007     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2013.02.020     Document Type: Article
Times cited : (59)

References (30)
  • 2
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • S.H. Bridle, A.D. Patel, M. Bircher, and P.T. Calvert Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw J Bone Joint Surg Br 73 1991 330 334
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 3
    • 0027520904 scopus 로고
    • Treatment of subtrochanteric fractures with the AO dynamic condylar screw
    • K.S. Nungu, C. Olerud, and L. Rehnberg Treatment of subtrochanteric fractures with the AO dynamic condylar screw Injury 24 1993 90 92
    • (1993) Injury , vol.24 , pp. 90-92
    • Nungu, K.S.1    Olerud, C.2    Rehnberg, L.3
  • 4
    • 0036512930 scopus 로고    scopus 로고
    • Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: A prospective, randomized study
    • C. Sadowski, A. Liibbeke, M. Saudan, N. Riand, R. Stem, and P. Hoffmeyer Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study J Bone Joint Surg Am 84 2002 372 381
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 372-381
    • Sadowski, C.1    Liibbeke, A.2    Saudan, M.3    Riand, N.4    Stem, R.5    Hoffmeyer, P.6
  • 5
    • 0024328634 scopus 로고
    • Sliding hip screws: Modes of failure
    • A.H. Simpson, K. Varty, and C.A. Dodd Sliding hip screws: modes of failure Injury 20 1989 227 231
    • (1989) Injury , vol.20 , pp. 227-231
    • Simpson, A.H.1    Varty, K.2    Dodd, C.A.3
  • 7
    • 35348840906 scopus 로고    scopus 로고
    • Evaluation of complications of three different types of proximal extraarticular femur fractures: Differences in complications, age, sex and surviving rates
    • A.A. Suckel, K. Dietz, N. Wuelker, and P. Helwig Evaluation of complications of three different types of proximal extraarticular femur fractures: differences in complications, age, sex and surviving rates Int Orthop 31 2007 689 695
    • (2007) Int Orthop , vol.31 , pp. 689-695
    • Suckel, A.A.1    Dietz, K.2    Wuelker, N.3    Helwig, P.4
  • 8
    • 0020076988 scopus 로고
    • Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation
    • G.L. Wolfgang, M.H. Bryant, and J.P. O'Neill Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation Clin Orthop Relat Res 163 1982 148 158
    • (1982) Clin Orthop Relat Res , vol.163 , pp. 148-158
    • Wolfgang, G.L.1    Bryant, M.H.2    O'Neill, J.P.3
  • 9
    • 68949186305 scopus 로고    scopus 로고
    • Unstable peritrochanteric femur fractures. Failure rate, lag screw sliding and outcome with extra- and intramedullary devices (PCCP, DHS and PFN)
    • M. Knobe, R. Münker, R.M. Sellei, B. Schmidt-Rohlfing, H.J. Erli, and C.S. Strobl Unstable peritrochanteric femur fractures. Failure rate, lag screw sliding and outcome with extra- and intramedullary devices (PCCP, DHS and PFN) Z Orthop Unfall 147 2009 306 313
    • (2009) Z Orthop Unfall , vol.147 , pp. 306-313
    • Knobe, M.1    Münker, R.2    Sellei, R.M.3    Schmidt-Rohlfing, B.4    Erli, H.J.5    Strobl, C.S.6
  • 10
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the gamma nail and compression hip screw
    • J.E. Madsen, L. Naess, A.K. Aune, A. Alho, A. Ekeland, and K. Strømsøe Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw J Orthop Trauma 12 1998 241 248
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Strømsøe, K.6
  • 11
    • 44449129620 scopus 로고    scopus 로고
    • Intramedullary nailing versus fixed angle blade plating for subtrochanteric femoral fractures: A prospective randomised controlled trial
    • D.M. Rahme, and I.A. Harris Intramedullary nailing versus fixed angle blade plating for subtrochanteric femoral fractures: a prospective randomised controlled trial J Orthop Surg 15 2007 278 281
    • (2007) J Orthop Surg , vol.15 , pp. 278-281
    • Rahme, D.M.1    Harris, I.A.2
  • 13
    • 59049089233 scopus 로고    scopus 로고
    • The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint
    • A. Brunner, J.A. Jöckel, and R. Babst The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint J Orthop Trauma 22 2008 731 736
    • (2008) J Orthop Trauma , vol.22 , pp. 731-736
    • Brunner, A.1    Jöckel, J.A.2    Babst, R.3
  • 14
    • 34548288913 scopus 로고    scopus 로고
    • Treatment of complex proximal femoral fractures with the proximal femur locking compression plate
    • E.A. Hasenboehler, J.F. Agudelo, S.J. Morgan, W.R. Smith, D.J. Hak, and P.F. Stahel Treatment of complex proximal femoral fractures with the proximal femur locking compression plate Orthopedics 30 2007 618 623
    • (2007) Orthopedics , vol.30 , pp. 618-623
    • Hasenboehler, E.A.1    Agudelo, J.F.2    Morgan, S.J.3    Smith, W.R.4    Hak, D.J.5    Stahel, P.F.6
  • 15
    • 84877784209 scopus 로고    scopus 로고
    • Synthes technique guide "LCP Proximal Femoral Plate 4.5/5.0. Part of the LCP Periarticular Plating System." Synthes GMBH Eimattstrasse, CH-4436 Oberdorf
    • Synthes technique guide "LCP Proximal Femoral Plate 4.5/5.0. Part of the LCP Periarticular Plating System." Synthes GMBH Eimattstrasse, CH-4436 Oberdorf. Available at: http://products.synthes.com/KYO-US/kyo-us-trauma/ Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/SUSA/ SUTG4.5LCPprxfemurJ4868D.pdf.
  • 16
    • 0030466101 scopus 로고    scopus 로고
    • Fractures of the acetabulum: Accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury
    • J.M. Matta Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury J Bone Joint Surg Am 78 1996 1632 1645
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1632-1645
    • Matta, J.M.1
  • 17
    • 0000505408 scopus 로고
    • The radiological diagnosis of osteoporosis; A new approach
    • E. Barnett, and B.E. Nordin The radiological diagnosis of osteoporosis; a new approach Clin Radiol 11 1960 166 174
    • (1960) Clin Radiol , vol.11 , pp. 166-174
    • Barnett, E.1    Nordin, B.E.2
  • 18
    • 54349097973 scopus 로고    scopus 로고
    • The current status of locked plating: The good, the bad, and the ugly
    • E.J. Strauss, R. Schwarzkopf, F. Kummer, and K.A. Egol The current status of locked plating: the good, the bad, and the ugly J Orthop Trauma 22 2008 479 486
    • (2008) J Orthop Trauma , vol.22 , pp. 479-486
    • Strauss, E.J.1    Schwarzkopf, R.2    Kummer, F.3    Egol, K.A.4
  • 19
    • 70450175850 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: A prospective series of 20 fractures
    • C.W. Oh, J.J. Kim, Y.S. Byun, J.K. Oh, J.W. Kim, and S.Y. Kim Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures Arch Orthop Trauma Surg 129 2009 1659 1665
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1659-1665
    • Oh, C.W.1    Kim, J.J.2    Byun, Y.S.3    Oh, J.K.4    Kim, J.W.5    Kim, S.Y.6
  • 20
    • 84872083396 scopus 로고    scopus 로고
    • Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures
    • P.N. Streubel, M.J. Moustoukas, and W.T. Obremskey Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures J Orthop Trauma 27 2013 22 28
    • (2013) J Orthop Trauma , vol.27 , pp. 22-28
    • Streubel, P.N.1    Moustoukas, M.J.2    Obremskey, W.T.3
  • 21
    • 70349748929 scopus 로고    scopus 로고
    • Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures
    • J.C. Floyd, R.V. O'Toole, A. Stall, D.P. Forward, M. Nabili, and D. Shillingburg Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures J Orthop Trauma 23 2009 628 633
    • (2009) J Orthop Trauma , vol.23 , pp. 628-633
    • Floyd, J.C.1    O'Toole, R.V.2    Stall, A.3    Forward, D.P.4    Nabili, M.5    Shillingburg, D.6
  • 22
    • 70349730382 scopus 로고    scopus 로고
    • A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model
    • B.D. Crist, M.A. Lee, and A.K. Khalaw A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model J Orthop Trauma 23 2009 622 627
    • (2009) J Orthop Trauma , vol.23 , pp. 622-627
    • Crist, B.D.1    Lee, M.A.2    Khalaw, A.K.3
  • 23
    • 77957340313 scopus 로고    scopus 로고
    • Fixation failure of the LCP proximal femoral Plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur
    • K. Wieser, and R. Babst Fixation failure of the LCP proximal femoral Plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur Arch Orthop Trauma Surg 130 2010 1281 1287
    • (2010) Arch Orthop Trauma Surg , vol.130 , pp. 1281-1287
    • Wieser, K.1    Babst, R.2
  • 24
    • 79551557597 scopus 로고    scopus 로고
    • Failure of proximal femoral locking compression plate: A case series
    • P.J. Glassner, and N.C. Tejwani Failure of proximal femoral locking compression plate: a case series J Orthop Trauma 25 2011 76 83
    • (2011) J Orthop Trauma , vol.25 , pp. 76-83
    • Glassner, P.J.1    Tejwani, N.C.2
  • 25
    • 84920207932 scopus 로고
    • The laws of bone architecture
    • J.C. Koch The laws of bone architecture Am J Anat 21 1917 177 298
    • (1917) Am J Anat , vol.21 , pp. 177-298
    • Koch, J.C.1
  • 28
    • 77952238721 scopus 로고    scopus 로고
    • Modern implant design for the osteosynthesis of osteoporotic bone fractures
    • P. Augat, and V. Bühren Modern implant design for the osteosynthesis of osteoporotic bone fractures Orthopäde 39 2010 397 406
    • (2010) Orthopäde , vol.39 , pp. 397-406
    • Augat, P.1    Bühren, V.2
  • 29
    • 35548978552 scopus 로고    scopus 로고
    • A review of locking compression plate biomechanics and their advantages as internal fixators and fracture healing
    • D.L. Miller, and T. Goswami A review of locking compression plate biomechanics and their advantages as internal fixators and fracture healing Clin Biomech 22 2007 1049 1062
    • (2007) Clin Biomech , vol.22 , pp. 1049-1062
    • Miller, D.L.1    Goswami, T.2
  • 30
    • 4844225504 scopus 로고    scopus 로고
    • Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    • J. Seebeck, J. Goldhahn, H. Stadele, P. Messmer, M.M. Morlock, and E. Schneider Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws J Orthop Res 22 2004 1237 1242
    • (2004) J Orthop Res , vol.22 , pp. 1237-1242
    • Seebeck, J.1    Goldhahn, J.2    Stadele, H.3    Messmer, P.4    Morlock, M.M.5    Schneider, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.