메뉴 건너뛰기




Volumn 130, Issue 10, 2010, Pages 1281-1287

Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur

Author keywords

LCP proximal femoral plate 4.5 5.0; Per , inter , and subtrochanteric fractures of the proximal femur; PF LCP; Secondary varus collapse of the fracture with hardware failure

Indexed keywords

ACETABULUM FRACTURE; ADULT; AGED; ARTICLE; BONE PLATE; BONE SCREW; BONE TRANSPLANTATION; CASE REPORT; COMMINUTED FRACTURE; DEVICE REMOVAL; FALLING; FEMUR FRACTURE; FEMUR INTERTROCHANTERIC FRACTURE; FEMUR PERTROCHANTERIC FRACTURE; FEMUR SUBTROCHANTERIC FRACTURE; FOLLOW UP; FRACTURE HEALING; GREATER TROCHANTER FRACTURE; HIP PAIN; HUMAN; MALE; MECHANICAL STRESS; MOBILIZATION; OPEN REDUCTION; OSTEOSYNTHESIS; PRIORITY JOURNAL; PROSTHESIS FAILURE; RANGE OF MOTION; REOPERATION; WEIGHT BEARING;

EID: 77957340313     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-010-1074-7     Document Type: Article
Times cited : (43)

References (17)
  • 1
    • 68949186305 scopus 로고    scopus 로고
    • Unstable pertrochanteric femur fractures. Failure rate, lag screw sliding and outcome with extra- and intramedullary devices (PCCP, DHS and PFN)
    • 1:STN:280:DC%2BD1MvpvVKgsw%3D%3D 10.1055/s-0029-1185349 19551581
    • M Knobe R Münker RM Sellei, et al. 2009 Unstable pertrochanteric femur fractures. Failure rate, lag screw sliding and outcome with extra- and intramedullary devices (PCCP, DHS and PFN) Z Orthop Unfall 147 306 313 1:STN:280:DC%2BD1MvpvVKgsw%3D%3D 10.1055/s-0029-1185349 19551581
    • (2009) Z Orthop Unfall , vol.147 , pp. 306-313
    • Knobe, M.1    Münker, R.2    Sellei, R.M.3
  • 2
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the gamma nail and compression hip screw
    • 1:STN:280:DyaK1c3otVOmtQ%3D%3D 10.1097/00005131-199805000-00005 9619458
    • JE Madsen L Naess AK Aune, et al. 1998 Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw J Orthop Trauma 12 241 248 1:STN:280:DyaK1c3otVOmtQ%3D%3D 10.1097/00005131- 199805000-00005 9619458
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3
  • 3
    • 44449129620 scopus 로고    scopus 로고
    • Intramedullary nailing versus fixed angle blade plating for subtrochanteric femoral fractures: A prospective randomised controlled trial
    • 1:STN:280:DC%2BD2sjmvVCgsw%3D%3D
    • DM Rahme IA Harris 2007 Intramedullary nailing versus fixed angle blade plating for subtrochanteric femoral fractures: a prospective randomised controlled trial J Orthop Surg 15 278 281 1:STN:280:DC%2BD2sjmvVCgsw%3D%3D
    • (2007) J Orthop Surg , vol.15 , pp. 278-281
    • Rahme, D.M.1    Harris, I.A.2
  • 4
    • 33750428548 scopus 로고    scopus 로고
    • First results with the Trochanter Fixation Nail (TFN): A report on 120 cases
    • DOI 10.1007/s00402-006-0117-6
    • A Lenich E Mayr A Rüter, et al. 2006 First results with the trochanter fixation nail (TFN): a report on 120 cases Arch Orthop Trauma Surg 126 706 712 1:STN:280:DC%2BD28njtlOjsg%3D%3D 10.1007/s00402-006-0117-6 16896745 (Pubitemid 44650702)
    • (2006) Archives of Orthopaedic and Trauma Surgery , vol.126 , Issue.10 , pp. 706-712
    • Lenich, A.1    Mayr, E.2    Ruter, A.3    Mockl, Ch.4    Fuchtmeier, B.5
  • 5
    • 59049089233 scopus 로고    scopus 로고
    • The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint
    • 10.1097/BOT.0b013e3181893b1b 18978550
    • A Brunner JA Jöckel R Babst 2008 The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint J Orthop Trauma 22 731 736 10.1097/BOT.0b013e3181893b1b 18978550
    • (2008) J Orthop Trauma , vol.22 , pp. 731-736
    • Brunner, A.1    Jöckel, J.A.2    Babst, R.3
  • 6
    • 54349097973 scopus 로고    scopus 로고
    • The current status of locked plating: The good, the bad, and the ugly
    • 10.1097/BOT.0b013e31817996d6 18670289
    • EJ Strauss R Schwarzkopf F Kummer, et al. 2008 The current status of locked plating: the good, the bad, and the ugly J Orthop Trauma 22 479 486 10.1097/BOT.0b013e31817996d6 18670289
    • (2008) J Orthop Trauma , vol.22 , pp. 479-486
    • Strauss, E.J.1    Schwarzkopf, R.2    Kummer, F.3
  • 7
    • 34548288913 scopus 로고    scopus 로고
    • Treatment of complex proximal femoral fractures with the proximal femur locking compression plate
    • 17727017
    • EA Hasenboehler JF Agudelo SJ Morgan, et al. 2007 Treatment of complex proximal femoral fractures with the proximal femur locking compression plate Orthopedics 30 618 623 17727017
    • (2007) Orthopedics , vol.30 , pp. 618-623
    • Hasenboehler, E.A.1    Agudelo, J.F.2    Morgan, S.J.3
  • 9
    • 0017857584 scopus 로고
    • Subtrochanteric fractures of the femur
    • 1:STN:280:DyaE1c7ntFKjsw%3D%3D 649632
    • F Seinsheimer 1978 Subtrochanteric fractures of the femur J Bone Joint Surg Am 60 300 306 1:STN:280:DyaE1c7ntFKjsw%3D%3D 649632
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 300-306
    • Seinsheimer, F.1
  • 11
    • 77957375817 scopus 로고    scopus 로고
    • A comparison of percutaneous versus traditional open plate fixation in a subtrochanteric fracture gap model
    • 5-7 October 2006, Phoenix, Ariz. Basic science poster #71
    • Christ BD, Lee MA, Khalafi AK et al (2006) A comparison of percutaneous versus traditional open plate fixation in a subtrochanteric fracture gap model. In: Proceedings of the annual meeting of the Orthopaedic Trauma Association (OTA), 5-7 October 2006, Phoenix, Ariz. Basic science poster #71
    • (2006) Proceedings of the Annual Meeting of the Orthopaedic Trauma Association (OTA)
    • Christ, B.D.1    Ma, L.2    Khalafi, A.K.3
  • 12
    • 84920207932 scopus 로고
    • The laws of bone architecture
    • 10.1002/aja.1000210202
    • JC Koch 1917 The laws of bone architecture Am J Anat 21 177 1298 10.1002/aja.1000210202
    • (1917) Am J Anat , vol.21 , pp. 177-1298
    • Koch, J.C.1
  • 13
    • 0027535152 scopus 로고
    • Low-energy subtrochanteric fractures in elderly patients: Results of fixation with the sliding screw plate
    • 1:STN:280:DyaK3s7nt1ejsg%3D%3D 10.1097/00005373-199301000-00010 8437196
    • AB Mullaji TL Thomas 1993 Low-energy subtrochanteric fractures in elderly patients: results of fixation with the sliding screw plate J Trauma 34 56 61 1:STN:280:DyaK3s7nt1ejsg%3D%3D 10.1097/00005373-199301000-00010 8437196
    • (1993) J Trauma , vol.34 , pp. 56-61
    • Mullaji, A.B.1    Thomas, T.L.2
  • 14
    • 0036512930 scopus 로고    scopus 로고
    • Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degree screw-plate: A prospective, randomized study
    • 11886906
    • C Sadowski A Lübbeke M Saudan, et al. 2002 Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degree screw-plate: a prospective, randomized study J Bone Joint Surg Am 84 372 381 11886906
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 372-381
    • Sadowski, C.1    Lübbeke, A.2    Saudan, M.3
  • 15
    • 0031646968 scopus 로고    scopus 로고
    • Problemlosung der extraartikularen, koxalen femurfraktur durch das 'gleitschrauben-nagel-prinzip'. Ergebnisse zweier verschiedener systeme (classic nail und γ-nagel)
    • DOI 10.1007/s001130050355
    • R Wagner TR Blattert A Weckbach 1998 Solution to the problem of extra-articular, femoral hip fracture by the "sliding screw-nail principle". Results of 2 different systems (classical nail and gamma nail) Unfallchirurg 101 894 900 1:STN:280:DyaK1M7kvFektQ%3D%3D 10.1007/s001130050355 10025238 (Pubitemid 28565058)
    • (1998) Unfallchirurg , vol.101 , Issue.12 , pp. 894-900
    • Wagner, R.1    Blattert, T.R.2    Weckbach, A.3
  • 16
    • 0032134683 scopus 로고    scopus 로고
    • Clinical results using the trochanter stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures
    • 1:STN:280:DyaK1czotFagtw%3D%3D 10.1097/00005131-199808000-00005 9715446
    • R Babst N Renner M Biedermann, et al. 1998 Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures J Orthop Trauma 12 392 399 1:STN:280:DyaK1czotFagtw%3D%3D 10.1097/00005131-199808000-00005 9715446
    • (1998) J Orthop Trauma , vol.12 , pp. 392-399
    • Babst, R.1    Renner, N.2    Biedermann, M.3
  • 17
    • 70450175850 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: A prospective series of 20 fractures
    • 10.1007/s00402-009-0815-y 19169695
    • CW Oh JJ Kim YS Byon, et al. 2009 Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures Arch Orthop Trauma Surg 129 1659 1665 10.1007/s00402-009-0815-y 19169695
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1659-1665
    • Oh, C.W.1    Kim, J.J.2    Byon, Y.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.