1
-
-
23944509795
-
Eine vergleichende untersuchung der versorgung instabiler per- und intertrochantärer femurfrakturen mittels DHS-osteosynthese unter verwendung der trochanterabstützplatte und dem proximalen femurnagel (PFN)
-
DOI 10.1055/s-2005-836784
-
Klinger HM, Baums MH, Eckert M, et al. [A comparative study of unstable per-and intertrochanteric femoral fractures treated with dynamic hip screw (DHS) and trochanteric butt-press plate vs. proximal femoral nail (PFN)]. Zentralbl Chir. 2005;130:301-306. (Pubitemid 41205749)
-
(2005)
Zentralblatt fur Chirurgie
, vol.130
, Issue.4
, pp. 301-306
-
-
Klinger, H.M.1
Baums, M.H.2
Eckert, M.3
Neugebauer, R.4
-
2
-
-
35648957731
-
Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate
-
DOI 10.1016/j.clinbiomech.2007.07.016, PII S0268003307001507
-
Krischak GD, Augat P, Beck A, et al. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: sliding hip screw and percutaneous compression plate. Clin Biomech (Bristol, Avon). 2007;22:1112-1118. (Pubitemid 350019516)
-
(2007)
Clinical Biomechanics
, vol.22
, Issue.10
, pp. 1112-1118
-
-
Krischak, G.D.1
Augat, P.2
Beck, A.3
Arand, M.4
Baier, B.5
Blakytny, R.6
Gebhard, F.7
Claes, L.8
-
3
-
-
78751617201
-
A biomechanical analysis of locking plate fixation with minimally invasive plate osteosynthesis in a subtrochanteric fracture model
-
Kim JW, Oh CW, Byun YS, et al. A biomechanical analysis of locking plate fixation with minimally invasive plate osteosynthesis in a subtrochanteric fracture model. J Trauma. 2010;70:E19-E23.
-
(2010)
J Trauma.
, vol.70
-
-
Kim, J.W.1
Oh, C.W.2
Byun, Y.S.3
-
4
-
-
70349730382
-
A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model
-
Crist BD, Khalafi A, Hazelwood SJ, et al. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model. J Orthop Trauma. 2009;23:622-627.
-
(2009)
J Orthop Trauma.
, vol.23
, pp. 622-627
-
-
Crist, B.D.1
Khalafi, A.2
Hazelwood, S.J.3
-
5
-
-
70349748929
-
Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures
-
Floyd JC, O'Toole RV, Stall A, et al. Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures. J Orthop Trauma. 2009;23:628-633.
-
(2009)
J Orthop Trauma.
, vol.23
, pp. 628-633
-
-
Floyd, J.C.1
O'Toole, R.V.2
Stall, A.3
-
6
-
-
79551557597
-
Failure of proximal femoral locking compression plate: A case series
-
Glassner PJ, Tejwani NC. Failure of proximal femoral locking compression plate: a case series. J Orthop Trauma. 2011;25:76-83.
-
(2011)
J Orthop Trauma.
, vol.25
, pp. 76-83
-
-
Glassner, P.J.1
Tejwani, N.C.2
-
7
-
-
77957340313
-
Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur
-
Wieser K, Babst R. Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur. Arch Orthop Trauma Surg. 2010;130:1281-1287.
-
(2010)
Arch Orthop Trauma Surg.
, vol.130
, pp. 1281-1287
-
-
Wieser, K.1
Babst, R.2
-
8
-
-
39149129995
-
Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association Classification, Database and Outcomes Committee
-
PII 0000513120071110100001
-
Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium-2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma. 2007;21:S1-S133. (Pubitemid 351253435)
-
(2007)
Journal of Orthopaedic Trauma
, vol.21
, Issue.10 SUPPL.
-
-
Marsh, J.L.1
Slongo, T.F.2
Agel, J.3
Broderick, J.S.4
Creevey, W.5
DeCoster, T.A.6
Prokuski, L.7
Sirkin, M.S.8
Ziran, B.9
Henley, B.10
Audige, L.11
-
10
-
-
0036512930
-
Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate: A prospective, randomized study
-
Sadowski C, Lubbeke A, Saudan M, et al. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am. 2002;84-A:372-381. (Pubitemid 37107707)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.3
, pp. 372-381
-
-
Sadowski, C.1
Lubbeke, A.2
Saudan, M.3
Riand, N.4
Stern, R.5
Hoffmeyer, P.6
-
11
-
-
17144467492
-
Reverse obliquity fractures of the intertrochanteric region of the femur
-
Haidukewych GJ, Israel TA, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am. 2001;83-A:643-650.
-
(2001)
J Bone Joint Surg Am.
, vol.83 A
, pp. 643-650
-
-
Haidukewych, G.J.1
Israel, T.A.2
Berry, D.J.3
-
12
-
-
0024954584
-
4-FRAGMENT-FRAKTUREN DES PROXIMALEN FEMURS: IST DIE DYNAMISCHE HUFTSCHRAUBE (DHS) EIN GEEIGNETES IMPLANTAT?
-
Hersche O, Heim D, Bodoky A, et al. [4 fragment fractures of the proximal femur: is the dynamic hip screw a suitable implant?]. Helv Chir Acta. 1989;56:577-580. (Pubitemid 20101434)
-
(1989)
Helvetica Chirurgica Acta
, vol.56
, Issue.4
, pp. 577-580
-
-
Hersche, O.1
Heim, D.2
Bodoky, A.3
Regazzoni, P.4
-
13
-
-
0025321432
-
Unstable intertrochanteric/subtrochanteric fractures of the femur
-
Whitelaw GP, Segal D, Sanzone CF, et al. Unstable intertrochanteric/ subtrochanteric fractures of the femur. Clin Orthop Relat Res. 1990;238-245. (Pubitemid 20109443)
-
(1990)
Clinical Orthopaedics and Related Research
, Issue.252
, pp. 238-245
-
-
Whitelaw, G.P.1
Segal, D.2
Sanzone, C.F.3
Ober, N.S.4
Hadley, N.5
-
14
-
-
59449105770
-
The treatment of intertrochanteric fractures: Results using an intramedullary nail with integrated cephalocervical screws and linear compression
-
Ruecker AH, Rupprecht M, Gruber M, et al. The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma. 2009;23:22-30.
-
(2009)
J Orthop Trauma.
, vol.23
, pp. 22-30
-
-
Ruecker, A.H.1
Rupprecht, M.2
Gruber, M.3
-
15
-
-
47549119043
-
The new proximal femoral nail antirotation (PFNA) in daily practice: Results of a multicentre clinical study
-
Simmermacher RK, Ljungqvist J, Bail H, et al. The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury. 2008;39:932-939.
-
(2008)
Injury
, vol.39
, pp. 932-939
-
-
Simmermacher, R.K.1
Ljungqvist, J.2
Bail, H.3
-
16
-
-
17644364373
-
Trochanteric Gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the Gamma nail
-
DOI 10.1097/01.bot.0000151819.95075.ad
-
Utrilla AL, Reig JS, Munoz FM, et al. Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma. 2005;19:229-233. (Pubitemid 40561584)
-
(2005)
Journal of Orthopaedic Trauma
, vol.19
, Issue.4
, pp. 229-233
-
-
Utrilla, A.L.1
Reig, J.S.2
Munoz, F.M.3
Tufanisco, C.B.4
-
17
-
-
0032134683
-
Clinical Results Using the Trochanter Stabilizing Plate (TSP): The Modular Extension of the Dynamic Hip Screw (DHS) for Internal Fixation of Selected Unstable Intertrochanteric Fractures
-
Babst R, Renner N, Biedermann M, et al. Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma. 1998;12:392-399. (Pubitemid 128454952)
-
(1998)
Journal of Orthopaedic Trauma
, vol.12
, Issue.6
, pp. 392-399
-
-
Babst, R.1
Renner, N.2
Biedermann, M.3
Rosso, R.4
Heberer, M.5
Harder, F.6
Regazzoni, P.7
-
19
-
-
36048999458
-
Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation [9]
-
Gotfried Y. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. J Bone Joint Surg Am. 2007;89:2552-2553; author reply 2553. (Pubitemid 350086357)
-
(2007)
Journal of Bone and Joint Surgery - Series A
, vol.89
, Issue.11
, pp. 2552-2553
-
-
Gotfried, Y.1
-
20
-
-
0031808886
-
Use of an intramedullary hipscrew compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients
-
Hardy DC, Descamps PY, Krallis P, et al. Use of an intramedullary hipscrew compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am. 1998;80:618-630.
-
(1998)
J Bone Joint Surg Am.
, vol.80
, pp. 618-630
-
-
Hardy, D.C.1
Descamps, P.Y.2
Krallis, P.3
-
21
-
-
0034991415
-
Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw
-
Olsson O, Ceder L, Hauggaard A. Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw. J Bone Joint Surg Br. 2001;83:572-578.
-
(2001)
J Bone Joint Surg Br.
, vol.83
, pp. 572-578
-
-
Olsson, O.1
Ceder, L.2
Hauggaard, A.3
-
22
-
-
0031872488
-
The Medoff sliding plate and a standard sliding hip screw for unstable intertrochanteric fractures. A mechanical comparison in cadaver femurs
-
Olsson O, Kummer FJ, Ceder L, et al. The Medoff sliding plate and a standard sliding hip screw for unstable intertrochanteric fractures: a mechanical comparison in cadaver femurs. Acta Orthop Scand. 1998;69:266-272. (Pubitemid 28369473)
-
(1998)
Acta Orthopaedica Scandinavica
, vol.69
, Issue.3
, pp. 266-272
-
-
Olsson, O.1
Kummer, F.J.2
Ceder, L.3
Koval, K.J.4
Larsson, S.5
Zuckerman, J.D.6
-
23
-
-
0026550876
-
Proximal femoral fractures. Is there an indication for the condylar screw (DCS) ?
-
Rosso R, Babst R, Marx A, et al. [Proximal femoral fractures. Is there an indication for the condylar screw (DCS) ?]. Helv Chir Acta. 1992;58:679-682.
-
(1992)
Helv Chir Acta.
, vol.58
, pp. 679-682
-
-
Rosso, R.1
Babst, R.2
Marx, A.3
-
24
-
-
0031646968
-
Problemlosung der extraartikularen, koxalen femurfraktur durch das 'gleitschrauben-nagel-prinzip'. Ergebnisse zweier verschiedener systeme (classic nail und γ-nagel)
-
DOI 10.1007/s001130050355
-
Wagner R, Blattert TR, Weckbach A. [Solution to the problem of extraarticular, femoral hip fracture by the "sliding screw-nail principle". Results of 2 different systems (classical nail and gamma nail)]. Unfallchirurg. 1998;101:894-900. (Pubitemid 28565058)
-
(1998)
Unfallchirurg
, vol.101
, Issue.12
, pp. 894-900
-
-
Wagner, R.1
Blattert, T.R.2
Weckbach, A.3
-
25
-
-
0025954887
-
A new device for the fixation of unstable pertrochanteric fractures of the hip
-
Medoff RJ, Maes K. A new device for the fixation of unstable pertrochanteric fractures of the hip. J Bone Joint Surg Am. 1991;73:1192-1199.
-
(1991)
J Bone Joint Surg Am.
, vol.73
, pp. 1192-1199
-
-
Medoff, R.J.1
Maes, K.2
-
26
-
-
0029012764
-
The value of the tipapex distance in predicting failure of fixation of peritrochanteric fractures of the hip
-
Baumgaertner MR, Curtin SL, Lindskog DM, et al. The value of the tipapex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058-1064.
-
(1995)
J Bone Joint Surg Am.
, vol.77
, pp. 1058-1064
-
-
Baumgaertner, M.R.1
Curtin, S.L.2
Lindskog, D.M.3
-
29
-
-
14644446095
-
Unstable pertrochanteric femoral fractures
-
DOI 10.1097/00005131-200501000-00014
-
Kregor PJ, Obremskey WT, Kreder HJ, et al. Unstable pertrochanteric femoral fractures. J Orthop Trauma. 2005;19:63-66. (Pubitemid 40309443)
-
(2005)
Journal of Orthopaedic Trauma
, vol.19
, Issue.1
, pp. 63-66
-
-
Kregor, P.J.1
Obremskey, W.T.2
Kreder, H.J.3
Swiontkowski, M.F.4
|