Structure and properties of soft tissues in the spine
-
Academic Press, Burlington, S.M. Kurtz, A.A. Edidin (Eds.)
-
Guerin H.A., Elliott D.M. Structure and properties of soft tissues in the spine. Spine Technology Handbook 2006, 35-62. Academic Press, Burlington. S.M. Kurtz, A.A. Edidin (Eds.).
-
(2006)
Spine Technology Handbook
, pp. 35-62
-
-
Guerin, H.A.1
Elliott, D.M.2
-
2
-
-
8644271684
-
Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion?
-
Hilibrand A.S., Robbins M. Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion?. Spine Journal 2004, 4:S190-S194.
-
(2004)
Spine Journal
, vol.4
-
-
Hilibrand, A.S.1
Robbins, M.2
-
3
-
-
79951680468
-
Artificial total disc replacement versus fusion for the cervical spine: a systematic review
-
Zechmeister I., Winkler R., Mad P. Artificial total disc replacement versus fusion for the cervical spine: a systematic review. European Spine Journal 2011, 20:177-184.
-
(2011)
European Spine Journal
, vol.20
, pp. 177-184
-
-
Zechmeister, I.1
Winkler, R.2
Mad, P.3
-
4
-
-
78449313863
-
Results at 24 months from the prospective, randomized, multicenter Investigational Device Exemption trial of ProDisc-C versus anterior cervical discectomy and fusion with 4-year follow-up and continued access patients
-
Delamarter R.B., Murrey D., Janssen M.E., Goldstein J.A., Zigler J., Tay B.K.B., Darden B. Results at 24 months from the prospective, randomized, multicenter Investigational Device Exemption trial of ProDisc-C versus anterior cervical discectomy and fusion with 4-year follow-up and continued access patients. SAS Journal 2010, 4:122-128.
-
(2010)
SAS Journal
, vol.4
, pp. 122-128
-
-
Delamarter, R.B.1
Murrey, D.2
Janssen, M.E.3
Goldstein, J.A.4
Zigler, J.5
Tay, B.K.B.6
Darden, B.7
-
5
-
-
33644663841
-
Assessment of adjacent-segment disease in patients treated with cervical fusion or arthroplasty: a prospective 2-year study
-
Robertson J.T., Papadopoulos S.M., Traynelis V.C. Assessment of adjacent-segment disease in patients treated with cervical fusion or arthroplasty: a prospective 2-year study. Journal of Neurosurgery-Spine 2005, 3:417-423.
-
(2005)
Journal of Neurosurgery-Spine
, vol.3
, pp. 417-423
-
-
Robertson, J.T.1
Papadopoulos, S.M.2
Traynelis, V.C.3
-
6
-
-
50049122121
-
The prevalence of indications and contraindications to cervical total disc replacement
-
Auerbach J.D., Jones K.J., Fras C.I., Balderston J.R., Rushton S.A., Chin K.R. The prevalence of indications and contraindications to cervical total disc replacement. Spine Journal 2008, 8:711-716.
-
(2008)
Spine Journal
, vol.8
, pp. 711-716
-
-
Auerbach, J.D.1
Jones, K.J.2
Fras, C.I.3
Balderston, J.R.4
Rushton, S.A.5
Chin, K.R.6
-
7
-
-
84882513853
-
Total disc arthroplasty
-
Academic Press, Burlington, S.M. Kurtz, A.A. Edidin (Eds.)
-
Kurtz S.M. Total disc arthroplasty. Spine Technology Handbook 2006, 303-370. Academic Press, Burlington. S.M. Kurtz, A.A. Edidin (Eds.).
-
(2006)
Spine Technology Handbook
, pp. 303-370
-
-
Kurtz, S.M.1
-
8
-
-
84857448904
-
ProDisc-C cervical disk arthroplasty
-
Darden B.V. ProDisc-C cervical disk arthroplasty. Seminars in Spine Surgery 2012, 24:8-13.
-
(2012)
Seminars in Spine Surgery
, vol.24
, pp. 8-13
-
-
Darden, B.V.1
-
9
-
-
8644228556
-
A. Cappuccino, F.P. Bellera, H.D. Link, Clinical experience with the new artificial cervical PCM (Cervitech) disc
-
Pimenta L., McAfee P.C. A. Cappuccino, F.P. Bellera, H.D. Link, Clinical experience with the new artificial cervical PCM (Cervitech) disc. Spine Journal 2004, 4:S315-S321.
-
(2004)
Spine Journal
, vol.4
-
-
Pimenta, L.1
McAfee, P.C.2
-
10
-
-
8644280476
-
The Prestige cervical disc replacement
-
Traynelis V.C. The Prestige cervical disc replacement. Spine Journal 2004, 4:310S-314S.
-
(2004)
Spine Journal
, vol.4
-
-
Traynelis, V.C.1
-
11
-
-
58149293408
-
Bryan cervical disc prostheses: preservation of function over time
-
Wenger M., van Hoonacker P., Zachee B., Lange R., Markwalder T.M. Bryan cervical disc prostheses: preservation of function over time. Journal of Clinical Neuroscience 2009, 16:220-225.
-
(2009)
Journal of Clinical Neuroscience
, vol.16
, pp. 220-225
-
-
Wenger, M.1
van Hoonacker, P.2
Zachee, B.3
Lange, R.4
Markwalder, T.M.5
-
12
-
-
84861843486
-
Intervertebral disc joint replacement technology
-
Woodhead Publishing Limited, Cambridge, A.P. Revell (Ed.)
-
Hallab N. Intervertebral disc joint replacement technology. Joint Replacement Technology 2008, 515-544. Woodhead Publishing Limited, Cambridge. A.P. Revell (Ed.).
-
(2008)
Joint Replacement Technology
, pp. 515-544
-
-
Hallab, N.1
-
13
-
-
33846670233
-
Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek)
-
Zeh A., Planert M., Siegert G., Lattke P., Held A., Hein W. Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek). Spine 2007, 32:348-352.
-
(2007)
Spine
, vol.32
, pp. 348-352
-
-
Zeh, A.1
Planert, M.2
Siegert, G.3
Lattke, P.4
Held, A.5
Hein, W.6
-
14
-
-
70349438594
-
Synthetic biomaterials for spinal applications
-
Academic Press, Burlington, S.M. Kurtz, A.A. Edidin (Eds.)
-
Brown S.A. Synthetic biomaterials for spinal applications. Spine Technology Handbook 2006, 11-33. Academic Press, Burlington. S.M. Kurtz, A.A. Edidin (Eds.).
-
(2006)
Spine Technology Handbook
, pp. 11-33
-
-
Brown, S.A.1
-
15
-
-
4744355541
-
The role of macrophages in osteolysis of total joint replacement
-
Ingham E., Fisher J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005, 26:1271-1286.
-
(2005)
Biomaterials
, vol.26
, pp. 1271-1286
-
-
Ingham, E.1
Fisher, J.2
-
19
-
-
26844437429
-
Polyetheretherketone as a biomaterial for spinal applications
-
Toth J.M., Wang M., Estes B.T., Scifert J.L., Seim H.B., Turner A.S. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 2006, 27:324-334.
-
(2006)
Biomaterials
, vol.27
, pp. 324-334
-
-
Toth, J.M.1
Wang, M.2
Estes, B.T.3
Scifert, J.L.4
Seim, H.B.5
Turner, A.S.6
-
20
-
-
84855419443
-
Macrophage reactivity to different polymers demonstrates particle size- and material-specific reactivity: PEEK-OPTIMA particles versus UHMWPE particles in the submicron, micron, and 10μm size ranges
-
Hallab N.J., McAllister K., Brady M., Jarman-Smith M. Macrophage reactivity to different polymers demonstrates particle size- and material-specific reactivity: PEEK-OPTIMA particles versus UHMWPE particles in the submicron, micron, and 10μm size ranges. Journal of Biomedial Materials Research Part B Applied Biomaterials 2012, 100:480-492.
-
(2012)
Journal of Biomedial Materials Research Part B Applied Biomaterials
, vol.100
, pp. 480-492
-
-
Hallab, N.J.1
McAllister, K.2
Brady, M.3
Jarman-Smith, M.4
-
21
-
-
84877347400
-
-
ISO 18192-1:2011. Implants for Surgery-Wear of Total Intervertebral Spinal Disc Prostheses Part 1: Loading and Displacement Parameters for Wear Testing and Corresponding Environmental Conditions for Test ISO International Standards. International Organization for Standarization, Geneva, Switzerland,
-
ISO 18192-1:2011. Implants for Surgery-Wear of Total Intervertebral Spinal Disc Prostheses Part 1: Loading and Displacement Parameters for Wear Testing and Corresponding Environmental Conditions for Test ISO International Standards. International Organization for Standarization, Geneva, Switzerland, 2011.
-
(2011)
-
-
-
22
-
-
0035736451
-
The wear of metal-on-metal total hip prostheses measured in a hip simulator
-
Scholes S.C., Green S.M., Unsworth A. The wear of metal-on-metal total hip prostheses measured in a hip simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 2001, 215:523-530.
-
(2001)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.215
, pp. 523-530
-
-
Scholes, S.C.1
Green, S.M.2
Unsworth, A.3
-
23
-
-
0035482516
-
Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator
-
Tipper J.L., Firkins P.J., Besong A.A., Barbour P.S.M., Nevelos J., Stone M.H., Ingham E., Fisher J. Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear 2001, 250:120-128.
-
(2001)
Wear
, vol.250
, pp. 120-128
-
-
Tipper, J.L.1
Firkins, P.J.2
Besong, A.A.3
Barbour, P.S.M.4
Nevelos, J.5
Stone, M.H.6
Ingham, E.7
Fisher, J.8
-
24
-
-
84877340999
-
Wear in metal-on-metal total disc arthroplasty
-
Moghadas P.M., Mahomed A., Hukins D.W.L., Shepherd D.E.T. Wear in metal-on-metal total disc arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 2013, 227:356-361.
-
(2013)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.227
, pp. 356-361
-
-
Moghadas, P.M.1
Mahomed, A.2
Hukins, D.W.L.3
Shepherd, D.E.T.4
-
25
-
-
70449532383
-
Alternative bearing materials for intervertebral disc arthroplasty
-
Grupp T.M., Meisel H.J., Cotton J.A., Schwiesau J., Fritz B., Blömer W., Jansson V. Alternative bearing materials for intervertebral disc arthroplasty. Biomaterials 2010, 31:523-531.
-
(2010)
Biomaterials
, vol.31
, pp. 523-531
-
-
Grupp, T.M.1
Meisel, H.J.2
Cotton, J.A.3
Schwiesau, J.4
Fritz, B.5
Blömer, W.6
Jansson, V.7
-
26
-
-
84856058762
-
Friction in metal-on-metal total disc arthroplasty: effect of ball radius
-
Moghadas P.M., Mahomed A., Hukins D.W.L., Shepherd D.E.T. Friction in metal-on-metal total disc arthroplasty: effect of ball radius. Journal of Biomechanics 2012, 45:504-509.
-
(2012)
Journal of Biomechanics
, vol.45
, pp. 504-509
-
-
Moghadas, P.M.1
Mahomed, A.2
Hukins, D.W.L.3
Shepherd, D.E.T.4
-
27
-
-
84899868215
-
Tribology in joint replacement
-
Woodhead Publishing Limited, Cambridge, A.P. Revell (Ed.)
-
Jin Z., Fisher J. Tribology in joint replacement. Joint Replacement Technology 2008, 31-50. Woodhead Publishing Limited, Cambridge. A.P. Revell (Ed.).
-
(2008)
Joint Replacement Technology
, pp. 31-50
-
-
Jin, Z.1
Fisher, J.2
-
28
-
-
84861842629
-
Biopolymer tribology
-
Imperial College Press, London, S.K. Sinha, B.J. Briscoe (Eds.)
-
Joyce T.J. Biopolymer tribology. Polymer Tribology 2009, 227-266. Imperial College Press, London. S.K. Sinha, B.J. Briscoe (Eds.).
-
(2009)
Polymer Tribology
, pp. 227-266
-
-
Joyce, T.J.1
-
29
-
-
84861866725
-
PEEK (Polyther-ether-ketone) based cervical total disc arthroplasty: contact stress and lubrication analysis
-
Xin H., Shepherd D.E.T., Dearn K.D. PEEK (Polyther-ether-ketone) based cervical total disc arthroplasty: contact stress and lubrication analysis. Open Biomedical Engineering Journal 2012, 6:73-79.
-
(2012)
Open Biomedical Engineering Journal
, vol.6
, pp. 73-79
-
-
Xin, H.1
Shepherd, D.E.T.2
Dearn, K.D.3
-
30
-
-
84867030650
-
Polymer-on-metal or metal-on-polymer total disc arthroplasty: does it make a difference?
-
Moghadas P.M., Shepherd D.E.T., Hukins D.W.L., Mahomed A. Polymer-on-metal or metal-on-polymer total disc arthroplasty: does it make a difference?. Spine 2012, 37:1834-1838.
-
(2012)
Spine
, vol.37
, pp. 1834-1838
-
-
Moghadas, P.M.1
Shepherd, D.E.T.2
Hukins, D.W.L.3
Mahomed, A.4
-
31
-
-
84877320674
-
-
Victrex PEEK™ 450G datasheet. Victrex Ltd. Avaliable from
-
Victrex PEEK™ 450G datasheet. 2012. Victrex Ltd. Avaliable from http://www.victrex.com/en/peek-450g-polymer.php.
-
(2012)
-
-
-
32
-
-
84877336740
-
Evaluation of PEEK on PEEK as a new articulation concept for cervical total disc replacement devices
-
Annunal meeting of the German spine society. Avaliable from
-
M. Kraft, D. Koch, M. Bushelow, Evaluation of PEEK on PEEK as a new articulation concept for cervical total disc replacement devices. Annunal meeting of the German spine society. 2011. Avaliable from http://www.medicalpeek.org/pub_reports/view/143.
-
(2011)
-
-
Kraft, M.1
Koch, D.2
Bushelow, M.3
-
33
-
-
70449533709
-
-
SAS, London, England
-
Brown T., Bao Q.B., Hallab N. Biotribological Assessment of Nunec, a PEEK on PEEK Cervical Disc Replacement According to ISO and ASTM Recommendations 2009, SAS, London, England.
-
(2009)
Biotribological Assessment of Nunec, a PEEK on PEEK Cervical Disc Replacement According to ISO and ASTM Recommendations
-
-
Brown, T.1
Bao, Q.B.2
Hallab, N.3
-
34
-
-
73149087679
-
The wear performance of PEEK-OPTIMA based self-mating couples
-
Scholes S.C., Unsworth A. The wear performance of PEEK-OPTIMA based self-mating couples. Wear 2010, 268:380-387.
-
(2010)
Wear
, vol.268
, pp. 380-387
-
-
Scholes, S.C.1
Unsworth, A.2
|