메뉴 건너뛰기




Volumn 37, Issue 2, 2009, Pages 650-658

Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model

Author keywords

Fluid responsiveness, preload, monitoring,pulse pressure variation, stroke volume variation, global end diastolic volume; Intraabdominal hypertension; Pneumoperitoneum, intra abdominal pressure

Indexed keywords

HETASTARCH;

EID: 64149097210     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e3181959864     Document Type: Article
Times cited : (105)

References (41)
  • 1
    • 0022637871 scopus 로고
    • Poor correlation between pulmonary arterial wedge pressure and left ventricular end-diastolic volume after coronary artery bypass graft surgery
    • Hansen RM, Viquerat CE, Matthay MA, et al: Poor correlation between pulmonary arterial wedge pressure and left ventricular end-diastolic volume after coronary artery bypass graft surgery. Anesthesiology 1986; 64: 764-770
    • (1986) Anesthesiology , vol.64 , pp. 764-770
    • Hansen, R.M.1    Viquerat, C.E.2    Matthay, M.A.3
  • 2
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • Hofer CK, Muller SM, Furrer L, et al: Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005; 128:848-854
    • (2005) Chest , vol.128 , pp. 848-854
    • Hofer, C.K.1    Muller, S.M.2    Furrer, L.3
  • 3
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence. Chest 2002; 121:2000-2008
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 4
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume
    • De Backer D, Heenen S, Piagnerelli M, et al: Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume. Intensive Care Med 2005; 31:517-523
    • (2005) Intensive Care Med , vol.31 , pp. 517-523
    • De Backer, D.1    Heenen, S.2    Piagnerelli, M.3
  • 5
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, et al: Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162: 134-138
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3
  • 6
    • 34648825072 scopus 로고    scopus 로고
    • Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions
    • Renner J, Gruenewald M, Brand P, et al: Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions. J Cardiothorac Vasc Anesth 2007; 21:650-654
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 650-654
    • Renner, J.1    Gruenewald, M.2    Brand, P.3
  • 7
    • 37349093358 scopus 로고    scopus 로고
    • Global end-diastolic volume during different loading conditions in a pediatric animal model
    • table of contents
    • Renner J, Meybohm P, Gruenewald M, et al: Global end-diastolic volume during different loading conditions in a pediatric animal model. Anesth Analg 2007; 105:1243-1249, table of contents
    • (2007) Anesth Analg , vol.105 , pp. 1243-1249
    • Renner, J.1    Meybohm, P.2    Gruenewald, M.3
  • 8
    • 33847653298 scopus 로고    scopus 로고
    • Cheatham ML, Malbrain ML, Kirkpatrick A, et al: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations. Intensive Care Med 2007; 33:951-962
    • Cheatham ML, Malbrain ML, Kirkpatrick A, et al: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations. Intensive Care Med 2007; 33:951-962
  • 9
    • 33750217742 scopus 로고    scopus 로고
    • Malbrain ML, Cheatham ML, Kirkpatrick A, et al: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions. Intensive Care Med 2006; 32:1722-1732
    • Malbrain ML, Cheatham ML, Kirkpatrick A, et al: Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions. Intensive Care Med 2006; 32:1722-1732
  • 10
    • 2442616190 scopus 로고    scopus 로고
    • Prevalence of intra-abdominal hypertension in critically ill patients: A multicentre epidemio-logical study
    • Malbrain ML, Chiumello D, Pelosi P, et al: Prevalence of intra-abdominal hypertension in critically ill patients: A multicentre epidemio-logical study. Intensive Care Med 2004; 30: 822-829
    • (2004) Intensive Care Med , vol.30 , pp. 822-829
    • Malbrain, M.L.1    Chiumello, D.2    Pelosi, P.3
  • 11
    • 0033770260 scopus 로고    scopus 로고
    • Abdominal perfusion pressure: A superior parameter in the assessment of intra-abdomi-nal hypertension
    • discussion 626-627
    • Cheatham ML, White MW, Sagraves SG, et al: Abdominal perfusion pressure: A superior parameter in the assessment of intra-abdomi-nal hypertension. J Trauma 2000; 49: 621-626; discussion 626-627
    • (2000) J Trauma , vol.49 , pp. 621-626
    • Cheatham, M.L.1    White, M.W.2    Sagraves, S.G.3
  • 12
    • 13444252257 scopus 로고    scopus 로고
    • Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: A multiple-center epidemi-ological study
    • Malbrain ML, Chiumello D, Pelosi P, et al: Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: A multiple-center epidemi-ological study. Crit Care Med 2005; 33: 315-322
    • (2005) Crit Care Med , vol.33 , pp. 315-322
    • Malbrain, M.L.1    Chiumello, D.2    Pelosi, P.3
  • 13
    • 0033931329 scopus 로고    scopus 로고
    • Incidence and clinical pattern of the abdominal compartment syndrome after "damage-control" lapa-rotomy in 311 patients with severe abdominal and/or pelvic trauma
    • Ertel W, Oberholzer A, Platz A, et al: Incidence and clinical pattern of the abdominal compartment syndrome after "damage-control" lapa-rotomy in 311 patients with severe abdominal and/or pelvic trauma. Crit Care Med 2000; 28: 1747-1753
    • (2000) Crit Care Med , vol.28 , pp. 1747-1753
    • Ertel, W.1    Oberholzer, A.2    Platz, A.3
  • 14
    • 0017804427 scopus 로고
    • Hemo-dynamics of increased intra-abdominal pressure: Interaction with hypovolemia and halo-thane anesthesia
    • Diamant M, Benumof JL, Saidman LJ: Hemo-dynamics of increased intra-abdominal pressure: Interaction with hypovolemia and halo-thane anesthesia. Anesthesiology 1978; 48: 23-27
    • (1978) Anesthesiology , vol.48 , pp. 23-27
    • Diamant, M.1    Benumof, J.L.2    Saidman, L.J.3
  • 15
    • 34047141699 scopus 로고    scopus 로고
    • Cardiovascular implications of abdominal compartment syndrome
    • Cheatham ML, Malbrain ML: Cardiovascular implications of abdominal compartment syndrome. Acta Clin Belg 2007; 1:98-112
    • (2007) Acta Clin Belg , vol.1 , pp. 98-112
    • Cheatham, M.L.1    Malbrain, M.L.2
  • 16
    • 0019394320 scopus 로고
    • Hemodynamic effect of increased abdominal pressure
    • Kashtan J, Green JF, Parsons EQ, et al: Hemodynamic effect of increased abdominal pressure. J Surg Res 1981; 30:249-255
    • (1981) J Surg Res , vol.30 , pp. 249-255
    • Kashtan, J.1    Green, J.F.2    Parsons, E.Q.3
  • 17
    • 34548587538 scopus 로고    scopus 로고
    • Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
    • Bliacheriene F, Machado SB, Fonseca EB, et al: Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum. Acta Anaesthesiol Scand 2007; 51:1268-1272
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 1268-1272
    • Bliacheriene, F.1    Machado, S.B.2    Fonseca, E.B.3
  • 18
    • 33846284531 scopus 로고    scopus 로고
    • Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs
    • Duperret S, Lhuillier F, Piriou V, et al: Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs. Intensive Care Med 2007; 33:163-171
    • (2007) Intensive Care Med , vol.33 , pp. 163-171
    • Duperret, S.1    Lhuillier, F.2    Piriou, V.3
  • 19
    • 0030029301 scopus 로고    scopus 로고
    • Total respiratory system, lung, and chest wall mechanics in sedated-paralyzed postoperative morbidly obese patients
    • Pelosi P, Croci M, Ravagnan I, et al: Total respiratory system, lung, and chest wall mechanics in sedated-paralyzed postoperative morbidly obese patients. Chest 1996; 109: 144-151
    • (1996) Chest , vol.109 , pp. 144-151
    • Pelosi, P.1    Croci, M.2    Ravagnan, I.3
  • 20
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • Wesseling KH, Jansen JR, Settels JJ, et al: Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 1993; 74:2566-2573
    • (1993) J Appl Physiol , vol.74 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.2    Settels, J.J.3
  • 21
    • 0034027184 scopus 로고    scopus 로고
    • Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilu-tion
    • Sakka SG, Ruhl CC, Pfeiffer UJ, et al: Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilu-tion. Intensive Care Med 2000; 26:180 -187
    • (2000) Intensive Care Med , vol.26 , pp. 180-187
    • Sakka, S.G.1    Ruhl, C.C.2    Pfeiffer, U.J.3
  • 22
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, et al: Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982; 126:1001-1004
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3
  • 23
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983; 148:839-843
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 24
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • quiz 449-415
    • Michard F: Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103:419-428; quiz 449-415
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 25
    • 19944404764 scopus 로고    scopus 로고
    • Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs
    • Berkenstadt H, Friedman Z, Preisman S, et al: Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Br J Anaesth 2005; 94:721-726
    • (2005) Br J Anaesth , vol.94 , pp. 721-726
    • Berkenstadt, H.1    Friedman, Z.2    Preisman, S.3
  • 26
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter DA, Felbinger TW, Schmidt C, et al: Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28:392-398
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3
  • 27
    • 40849136326 scopus 로고    scopus 로고
    • Functional haemo-dynamics during intra-abdominal hypertension: What to use and what not use
    • Malbrain ML, De Laet I: Functional haemo-dynamics during intra-abdominal hypertension: What to use and what not use. Acta Anaesthesiol Scand 2008; 52:576-577
    • (2008) Acta Anaesthesiol Scand , vol.52 , pp. 576-577
    • Malbrain, M.L.1    De Laet, I.2
  • 28
    • 0032988086 scopus 로고    scopus 로고
    • Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
    • Michard F, Chemla D, Richard C, et al: Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 1999; 159:935-939
    • (1999) Am J Respir Crit Care Med , vol.159 , pp. 935-939
    • Michard, F.1    Chemla, D.2    Richard, C.3
  • 29
    • 0034053741 scopus 로고    scopus 로고
    • Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum
    • Tournadre JP, Allaouchiche B, Cayrel V, et al: Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum. Acta Anaesthesiol Scand 2000; 44:231-235
    • (2000) Acta Anaesthesiol Scand , vol.44 , pp. 231-235
    • Tournadre, J.P.1    Allaouchiche, B.2    Cayrel, V.3
  • 30
    • 34249732090 scopus 로고    scopus 로고
    • Effect of intra-abdominal pressure on respiratory mechanics
    • Pelosi P, Quintel M, Malbrain ML: Effect of intra-abdominal pressure on respiratory mechanics. Acta Clin Belg 2007 ; 1:78-88
    • (2007) Acta Clin Belg , vol.1 , pp. 78-88
    • Pelosi, P.1    Quintel, M.2    Malbrain, M.L.3
  • 31
    • 10744219512 scopus 로고    scopus 로고
    • An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury
    • Quintel M, Pelosi P, Caironi P, et al: An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury. Am J Respir Crit Care Med 2004; 169:534-541
    • (2004) Am J Respir Crit Care Med , vol.169 , pp. 534-541
    • Quintel, M.1    Pelosi, P.2    Caironi, P.3
  • 32
    • 35448947970 scopus 로고    scopus 로고
    • The polycompart-ment syndrome: Towards an understanding of the interactions between different compartments!
    • Malbrain ML, Wilmer A: The polycompart-ment syndrome: Towards an understanding of the interactions between different compartments! Intensive Care Med 2007; 33:1869-1872
    • (2007) Intensive Care Med , vol.33 , pp. 1869-1872
    • Malbrain, M.L.1    Wilmer, A.2
  • 33
    • 34249716396 scopus 로고    scopus 로고
    • Abdomino-thoracic transmission during ACS: Facts and figures
    • Wauters J, Wilmer A, Valenza F: Abdomino-thoracic transmission during ACS: Facts and figures. Acta Clin Belg 2007; 1:200-205
    • (2007) Acta Clin Belg , vol.1 , pp. 200-205
    • Wauters, J.1    Wilmer, A.2    Valenza, F.3
  • 34
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac cardiac output monitoring system
    • Opdam HI, Wan L, Bellomo R: A pilot assessment of the FloTrac cardiac output monitoring system. Intensive Care Med 2007; 33: 344-349
    • (2007) Intensive Care Med , vol.33 , pp. 344-349
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3
  • 35
    • 24944439222 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
    • Pittman J, Bar-Yosef S, SumPing J, et al: Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 2005; 33:2015-2021
    • (2005) Crit Care Med , vol.33 , pp. 2015-2021
    • Pittman, J.1    Bar-Yosef, S.2    SumPing, J.3
  • 36
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    • Bein B, Meybohm P, Cavus E, et al: The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg 2007; 105:107-113
    • (2007) Anesth Analg , vol.105 , pp. 107-113
    • Bein, B.1    Meybohm, P.2    Cavus, E.3
  • 37
    • 34250341289 scopus 로고    scopus 로고
    • Kubitz JC, Annecke T, Forkl S, et al: Validation of pulse contour derived stroke variation during modifications of cardiac afterload. Br J Anaesth 2007; 98:591-597
    • Kubitz JC, Annecke T, Forkl S, et al: Validation of pulse contour derived stroke volume \ variation during modifications of cardiac afterload. Br J Anaesth 2007; 98:591-597
  • 38
    • 26244465249 scopus 로고    scopus 로고
    • Estimation of errors in determining intratho-racic blood volume using the single transpulmonary thermal dilution technique in hypovolemic shock
    • Nirmalan M, Willard TM, Edwards DJ, et al: Estimation of errors in determining intratho-racic blood volume using the single transpulmonary thermal dilution technique in hypovolemic shock. Anesthesiology 2005; 103: 805-812
    • (2005) Anesthesiology , vol.103 , pp. 805-812
    • Nirmalan, M.1    Willard, T.M.2    Edwards, D.J.3
  • 39
    • 0031824069 scopus 로고    scopus 로고
    • Mathematical coupling in medical research: Lessons from studies of oxygen kinetics
    • Walsh TS, Lee A: Mathematical coupling in medical research: Lessons from studies of oxygen kinetics. Br J Anaesth 1998; 81:118 -120
    • (1998) Br J Anaesth , vol.81 , pp. 118-120
    • Walsh, T.S.1    Lee, A.2
  • 40
    • 0033801682 scopus 로고    scopus 로고
    • Investigating the relationship between intrathoracic blood volume index and cardiac index
    • McLuckie A, Bihari D: Investigating the relationship between intrathoracic blood volume index and cardiac index. Intensive Care Med 2000; 26:1376-1378
    • (2000) Intensive Care Med , vol.26 , pp. 1376-1378
    • McLuckie, A.1    Bihari, D.2
  • 41
    • 0034911132 scopus 로고    scopus 로고
    • Changes in cardiac output and intrathoracic blood volume: A mathematical coupling of data?
    • Buhre W, Kazmaier S, Sonntag H, et al: Changes in cardiac output and intrathoracic blood volume: A mathematical coupling of data? Acta Anaesthesiol Scand 2001; 45: 863-867
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 863-867
    • Buhre, W.1    Kazmaier, S.2    Sonntag, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.