-
1
-
-
84875588717
-
-
European Pharmacopeia 7.4, Amlodipine besilate 04/2012:
-
European Pharmacopeia 7.4, Amlodipine besilate 04/2012: 1491, 4275-4276.
-
(1491)
, pp. 4275-4276
-
-
-
2
-
-
84875592296
-
-
ICH Q8 (R2). Guidance for industry. Pharmaceutical Development
-
ICH Q8 (R2). Guidance for industry. Pharmaceutical Development, 2009.
-
(2009)
-
-
-
3
-
-
77951977827
-
Aspects of the " Design Space" in high pressure liquid chromatography method development
-
Molnár I., Rieger H.-J., Monks K.E. Aspects of the " Design Space" in high pressure liquid chromatography method development. J. Chromatogr. A 2010, 1217:3193-3200.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 3193-3200
-
-
Molnár, I.1
Rieger, H.-J.2
Monks, K.E.3
-
4
-
-
84888280147
-
Experimental combination of method development strategies in a working environment of different instrumental set-ups
-
Molnár I., Monks K.E., Rieger H.-J., Erxleben B.-T. Experimental combination of method development strategies in a working environment of different instrumental set-ups. LCGC-Magazine 2011, 7:2-8.
-
(2011)
LCGC-Magazine
, vol.7
, pp. 2-8
-
-
Molnár, I.1
Monks, K.E.2
Rieger, H.-J.3
Erxleben, B.-T.4
-
6
-
-
70349801683
-
Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2_m particles and Design Space computer modelling
-
Sz.Fekete, Fekete J., Molnár I., Ganzler K. Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2_m particles and Design Space computer modelling. J. Chromatogr. A 2009, 1216:7816-7823.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 7816-7823
-
-
Fekete, S.Z.1
Fekete, J.2
Molnár, I.3
Ganzler, K.4
-
7
-
-
84858079402
-
Quality by Design: multidimensional exploration of the design space in high performance liquid chromatography method development for better robustness before validation
-
Monks K., Molnár I., Rieger H.J., Bogáti B., Szabó E. Quality by Design: multidimensional exploration of the design space in high performance liquid chromatography method development for better robustness before validation. J. Chromatogr. A 2012, 1232:218-230.
-
(2012)
J. Chromatogr. A
, vol.1232
, pp. 218-230
-
-
Monks, K.1
Molnár, I.2
Rieger, H.J.3
Bogáti, B.4
Szabó, E.5
-
8
-
-
79957512754
-
A stepwise strategy employing automated screening and DryLab modeling for the development of robust methods for challenging high performance liquid chromatography separations: a case study
-
Jayaraman K., Alexander A.J., Hu Y., Tomasella F.P. A stepwise strategy employing automated screening and DryLab modeling for the development of robust methods for challenging high performance liquid chromatography separations: a case study. Anal. Chim. Acta 2011, 696:116-124.
-
(2011)
Anal. Chim. Acta
, vol.696
, pp. 116-124
-
-
Jayaraman, K.1
Alexander, A.J.2
Hu, Y.3
Tomasella, F.P.4
-
9
-
-
33747030441
-
Retention modeling in ternary solvent gradient elution reversed phase chromatography using 30mm columns
-
Euerby M.R., Scannapieco F., Rieger H.-J., Molnár I. Retention modeling in ternary solvent gradient elution reversed phase chromatography using 30mm columns. J. Chromatogr. A 2006, 1121:219-227.
-
(2006)
J. Chromatogr. A
, vol.1121
, pp. 219-227
-
-
Euerby, M.R.1
Scannapieco, F.2
Rieger, H.-J.3
Molnár, I.4
-
10
-
-
79958269017
-
3-Dimensional retention modelling of gradient time, ternary solvent-strength and temperature of the reversed-phase gradient liquid chromatography of a complex mixture of 22 basic and neutral analytes using DryLab® 2010
-
Euerby M., Schad G., Rieger H.-J., Molnár I. 3-Dimensional retention modelling of gradient time, ternary solvent-strength and temperature of the reversed-phase gradient liquid chromatography of a complex mixture of 22 basic and neutral analytes using DryLab® 2010. Chromatogr. Today 2010, 3:13-20.
-
(2010)
Chromatogr. Today
, vol.3
, pp. 13-20
-
-
Euerby, M.1
Schad, G.2
Rieger, H.-J.3
Molnár, I.4
-
11
-
-
9644284417
-
The hydrophobic-subtraction model of reversed-phase column selectivity
-
Snyder L.R., Dolan J.W., Carr P.W. The hydrophobic-subtraction model of reversed-phase column selectivity. J. Chromatogr. A 2004, 1060:77-116.
-
(2004)
J. Chromatogr. A
, vol.1060
, pp. 77-116
-
-
Snyder, L.R.1
Dolan, J.W.2
Carr, P.W.3
-
12
-
-
84857042240
-
Practical implications of the Tanaka stationary phase characterization methodology using ultra high performance liquid chromatographic conditions
-
Euerby M.R., Jamesa M., Petersson P. Practical implications of the Tanaka stationary phase characterization methodology using ultra high performance liquid chromatographic conditions. J. Chromatogr. A 2012, 1228:165-174.
-
(2012)
J. Chromatogr. A
, vol.1228
, pp. 165-174
-
-
Euerby, M.R.1
Jamesa, M.2
Petersson, P.3
-
13
-
-
84866719302
-
Validation of the extended Tanaka column characterization protocol by multivariate analysis of chromatographic retention of low-molecular-weight analytes on reversed phase columns using methanol and acetonitrile as organic modifiers
-
Euerby M.R., James M., Axelsson B.-O., Rosén O., Petersson P. Validation of the extended Tanaka column characterization protocol by multivariate analysis of chromatographic retention of low-molecular-weight analytes on reversed phase columns using methanol and acetonitrile as organic modifiers. J. Sep. Sci. 2012, 35:2592-2598.
-
(2012)
J. Sep. Sci.
, vol.35
, pp. 2592-2598
-
-
Euerby, M.R.1
James, M.2
Axelsson, B.-O.3
Rosén, O.4
Petersson, P.5
-
14
-
-
0034601924
-
Selectivity differences for C18 reversed-phase columns as a function of temperature and gradient steepness. I. Optimizing selectivity and resolution
-
Dolan J.W., Snyder L.R., Blanc T., L.Van Heukelem Selectivity differences for C18 reversed-phase columns as a function of temperature and gradient steepness. I. Optimizing selectivity and resolution. J. Chromatogr. A 2000, 897:37-50.
-
(2000)
J. Chromatogr. A
, vol.897
, pp. 37-50
-
-
Dolan, J.W.1
Snyder, L.R.2
Blanc, T.3
Van Heukelem, L.4
-
17
-
-
9644295485
-
Solvophobic interactions in liquid chromatography with nonpolar stationary phases
-
Cs.Horváth, Melander W., Molnár I. Solvophobic interactions in liquid chromatography with nonpolar stationary phases. J. Chromatogr. 1976, 125:129-156.
-
(1976)
J. Chromatogr.
, vol.125
, pp. 129-156
-
-
Horváth, C.S.1
Melander, W.2
Molnár, I.3
-
18
-
-
0024832467
-
Computer-assisted method development for high-performance liquid chromatography, edited by J.L. Glajch and L.R. Snyder, Elsevier 1990, ISBN 0-444-88748-2
-
Snyder L.R., Glajch J.L. Computer-assisted method development for high-performance liquid chromatography, edited by J.L. Glajch and L.R. Snyder, Elsevier 1990, ISBN 0-444-88748-2. J. Chromatogr. 1989, 485:1-640.
-
(1989)
J. Chromatogr.
, vol.485
, pp. 1-640
-
-
Snyder, L.R.1
Glajch, J.L.2
-
19
-
-
0037008237
-
Computerized design of separation strategies by reversed-phase liquid chromatography: development of DryLab software
-
Molnár I. Computerized design of separation strategies by reversed-phase liquid chromatography: development of DryLab software. J. Chromatogr. A 2002, 965:175-194.
-
(2002)
J. Chromatogr. A
, vol.965
, pp. 175-194
-
-
Molnár, I.1
-
20
-
-
79958256388
-
From Csaba Horváth to Quality by Design: visualizing design space in selectivity exploration of HPLC separations
-
Molnár I., Monks K. From Csaba Horváth to Quality by Design: visualizing design space in selectivity exploration of HPLC separations. Chromatographia 2011, 73(Suppl. 1):S5-S14.
-
(2011)
Chromatographia
, vol.73
, Issue.SUPPL. 1
-
-
Molnár, I.1
Monks, K.2
-
21
-
-
84874532654
-
Using an innovative Quality-by-Design approach for development of a stability indicating UHPLC method for ebastine in the API and pharmaceutical formulations
-
Schmidt A.H., Molnár I. Using an innovative Quality-by-Design approach for development of a stability indicating UHPLC method for ebastine in the API and pharmaceutical formulations. J. Pharm. Biomed. Anal. 2013, 78-79:65-74. 10.1016/j.jpba.2013.01.032.
-
(2013)
J. Pharm. Biomed. Anal.
, vol.78-79
, pp. 65-74
-
-
Schmidt, A.H.1
Molnár, I.2
|