메뉴 건너뛰기




Volumn 176, Issue , 2013, Pages 960-965

Deflection cantilever detection of interferon gamma

Author keywords

Cantilever; Deflection; Interferon gamma; Protein detection; Sensor Linking

Indexed keywords

ANTIBIOTICS; ANTIBODIES; BINS; BIOMARKERS; GLYCOPROTEINS; NANOCANTILEVERS; PROTEINS;

EID: 84875464351     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.09.023     Document Type: Article
Times cited : (13)

References (32)
  • 2
    • 70349742564 scopus 로고    scopus 로고
    • C-Reactive protein as a risk factor for coronary heart disease: A systematic review and meta-analyses for the U.S. preventive services task force
    • D.I. Buckley, R. Fu, M. Freeman, K. Rogers, M. Helfand, C-reactive protein as a risk factor for coronary heart disease: a systematic review and meta-analyses for the U.S. preventive services task force, Annals of Internal Medicine 151 (7) (2009) 483-495.
    • (2009) Annals of Internal Medicine , vol.151 , Issue.7 , pp. 483-495
    • Buckley, D.I.1    Fu, R.2    Freeman, M.3    Rogers, K.4    Helfand, M.5
  • 5
    • 34250689035 scopus 로고    scopus 로고
    • Interferonγ/IL10 ratio defines the disease severity in pulmonary and extra pulmonary tuberculosis
    • DOI 10.1016/j.tube.2007.03.004, PII S1472979207000364
    • B. Jamil, F. Shahid, Z. Hasan, N. Nasir, T. Razzaki, G. Dawood, R. Hussain, Interferon gamma/IL10 ratio defines the disease severity in pulmonary and extra pulmonary tuberculosis, Tuberculosis (Edinburgh) 87 (4) (2007) 279-287. (Pubitemid 46936246)
    • (2007) Tuberculosis , vol.87 , Issue.4 , pp. 279-287
    • Jamil, B.1    Shahid, F.2    Hasan, Z.3    Nasir, N.4    Razzaki, T.5    Dawood, G.6    Hussain, R.7
  • 8
    • 84862885682 scopus 로고    scopus 로고
    • Critical issues in sensor science to aid food and water safety
    • R.H. Farahi, A. Passian, L. Tetard, T. Thundat, Critical issues in sensor science to aid food and water safety, ACS Nano 6 (6) (2012) 4548-4556.
    • (2012) ACS Nano , vol.6 , Issue.6 , pp. 4548-4556
    • Farahi, R.H.1    Passian, A.2    Tetard, L.3    Thundat, T.4
  • 9
    • 0034874270 scopus 로고    scopus 로고
    • Bioassay of prostate-specific antigen (PSA) using microcantilevers
    • DOI 10.1038/nbt0901-856
    • G. Wu, R.H. Datar, K.M. Hansen, T. Thundat, R.J. Cote, A. Majumdar, Bioassay of prostate-specific antigen (PSA) using microcantilevers, Nature Biotechnology 19 (9) (2001) 856-860. (Pubitemid 32816756)
    • (2001) Nature Biotechnology , vol.19 , Issue.9 , pp. 856-860
    • Wu, G.1    Datar, R.H.2    Hansen, K.M.3    Thundat, T.4    Cote, R.J.5    Majumdar, A.6
  • 10
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • DOI 10.1016/j.bios.2004.09.023, PII S0956566304004282
    • K.W. Wee, G.Y. Kang, J. Park, J.Y. Kang, D.S. Yoon, J.H. Park, T.S. Kim, Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers, Biosensors and Bioelectronics 20 (10) (2005) 1932-1938. (Pubitemid 40312087)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.10 SPEC. ISS. , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6    Kim, T.S.7
  • 11
    • 40449105434 scopus 로고    scopus 로고
    • Label-free protein recognition two-dimensional array using nanomechanical sensors
    • DOI 10.1021/nl072740c
    • M. Yue, J.C. Stachowiak, H. Lin, R. Datar, R. Cote, A. Majumdar, Label-free protein recognition two-dimensional array using nanomechanical sensors, Nano Letters 8 (2) (2008) 520-524. (Pubitemid 351346011)
    • (2008) Nano Letters , vol.8 , Issue.2 , pp. 520-524
    • Yue, M.1    Stachowiak, J.C.2    Lin, H.3    Datar, R.4    Cote, R.5    Majumdar, A.6
  • 14
    • 33947598123 scopus 로고    scopus 로고
    • Antibody-based protein detection using piezoresistive cantilever arrays
    • V. Dauksaite, M. Lorentzen, F. Besenbacher, J. Kjems, Antibody-based protein detection using piezoresistive cantilever arrays, Nanotechnology 18 (2007) 125503-125507.
    • (2007) Nanotechnology , vol.18 , pp. 125503-125507
    • Dauksaite, V.1    Lorentzen, M.2    Besenbacher, F.3    Kjems, J.4
  • 16
    • 0036166152 scopus 로고    scopus 로고
    • Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor
    • DOI 10.1016/S0956-5663(01)00276-7, PII S0956566301002767
    • C. Grogan, R. Raiteri, G.M. O'Connor, T.J. Glynn, V. Cunningham, M. Kane, M. Charlton, D. Leech, Characterization of an antibody coated microcantilever as a potential immuno-based biosensor, Biosensors and Bioelectronics 17 (3) (2002) 201-207. (Pubitemid 34142600)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.3 , pp. 201-207
    • Grogan, C.1    Raiteri, R.2    O'Connor, G.M.3    Glynn, T.J.4    Cunningham, V.5    Kane, M.6    Charlton, M.7    Leech, D.8
  • 17
    • 30644459606 scopus 로고    scopus 로고
    • Cantilever sensor for nanomechanical detection of specific protein conformations
    • DOI 10.1021/nl051449z
    • R. Mukhopadhyay, V.V. Sumbayev, M. Lorentzen, J. Kjems, P.A. Andreasen, F. Besenbacher, Cantilever sensor for nanomechanical detection of specific protein conformations, Nano Letters 5 (12) (2005) 2385-2388. (Pubitemid 43088882)
    • (2005) Nano Letters , vol.5 , Issue.12 , pp. 2385-2388
    • Mukhopadhyay, R.1    Sumbayev, V.V.2    Lorentzen, M.3    Kjems, J.4    Andreasen, P.A.5    Besenbacher, F.6
  • 18
    • 48149099409 scopus 로고    scopus 로고
    • Highly specific label-free protein detection from lysed cells using internally referenced microcantilever sensors
    • W. Shu, S. Laurenson, T.P. Knowles, P. Ko Ferrigno, A.A. Seshia, Highly specific label-free protein detection from lysed cells using internally referenced microcantilever sensors, Biosensors and Bioelectronics 24 (2) (2008) 233-237.
    • (2008) Biosensors and Bioelectronics , vol.24 , Issue.2 , pp. 233-237
    • Shu, W.1    Laurenson, S.2    Knowles, T.P.3    Ko Ferrigno, P.4    Seshia, A.A.5
  • 19
    • 2642579896 scopus 로고    scopus 로고
    • Micromechanical detection of proteins using aptamer-based receptor molecules
    • DOI 10.1021/ac049859f
    • C.A. Savran, S.M. Knudsen, A.D. Ellington, S.R. Manalis, Micromechanical detection of proteins using aptamer-based receptor molecules, Analytical Chemistry 76 (11) (2004) 3194-3198. (Pubitemid 38715714)
    • (2004) Analytical Chemistry , vol.76 , Issue.11 , pp. 3194-3198
    • Savran, C.A.1    Knudsen, S.M.2    Ellington, A.D.3    Manalis, S.R.4
  • 22
    • 33847381431 scopus 로고    scopus 로고
    • Investigation of biotin-streptavidin binding interactions using microcantilever sensors
    • DOI 10.1016/j.bios.2006.08.047, PII S0956566306004155, Selected Papers from the Ninth World Congress On Biosensors
    • W. Shu, E.D. Laue, A.A. Seshia, Investigation of biotin-streptavidin binding interactions using microcantilever sensors, Biosensors and Bioelectronics 22 (9-10) (2007) 2003-2009. (Pubitemid 46349637)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2003-2009
    • Shu, W.1    Laue, E.D.2    Seshia, A.A.3
  • 25
    • 33645085279 scopus 로고    scopus 로고
    • MOSFET-embedded microcantilevers for measuring deflection in biomolecular sensors
    • G. Shekhawat, S.H. Tark, V.P. Dravid, MOSFET-embedded microcantilevers for measuring deflection in biomolecular sensors, Science 311 (5767) (2006) 1592-1595.
    • (2006) Science , vol.311 , Issue.5767 , pp. 1592-1595
    • Shekhawat, G.1    Tark, S.H.2    Dravid, V.P.3
  • 26
    • 33646884184 scopus 로고    scopus 로고
    • Nanostructured cantilevers as nanomechanical immunosensors for cytokine detection
    • DOI 10.1385/NBT:1:3:237
    • P. Dutta, J. Sanseverino, P.G. Datskos, M.J. Sepaniak, Nanostructured cantilevers as nanomechanical immunosensors for cytokine detection, NanoBiotechnology 1 (3) (2005) 237-244. (Pubitemid 43780220)
    • (2005) Nanobiotechnology , vol.1 , Issue.3 , pp. 237-244
    • Dutta, P.1    Sanseverino, J.2    Datskos, P.G.3    Sepaniak, M.J.4
  • 27
    • 55049127624 scopus 로고    scopus 로고
    • Characterization of Young's modulus of silicon versus temperature using a beam deflection method with a four-point bending fixture
    • C.-H. Cho, Characterization of Young's modulus of silicon versus temperature using a "beam deflection" method with a four-point bending fixture, Current Applied Physics 9 (2) (2009) 538-545.
    • (2009) Current Applied Physics , vol.9 , Issue.2 , pp. 538-545
    • Cho, C.-H.1
  • 29
    • 0030070499 scopus 로고    scopus 로고
    • Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport
    • P. Schuck, Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport, Biophysical Journal 70 (3) (1996) 1230-1249. (Pubitemid 26073037)
    • (1996) Biophysical Journal , vol.70 , Issue.3 , pp. 1230-1249
    • Schuck, P.1
  • 30
    • 0026153423 scopus 로고
    • Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins
    • E. Stenberg, B. Persson, H. Roos, C. Urbaniczky, Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins, Journal of Colloid and Interface Science 143 (2) (1991) 513-526.
    • (1991) Journal of Colloid and Interface Science , vol.143 , Issue.2 , pp. 513-526
    • Stenberg, E.1    Persson, B.2    Roos, H.3    Urbaniczky, C.4
  • 32
    • 34347209835 scopus 로고
    • Calculation of thermal noise in atomic force microscopy
    • H.-J. Butt, M. Jaschke, Calculation of thermal noise in atomic force microscopy, Nanotechnology 6 (1) (1995) 1-7.
    • (1995) Nanotechnology , vol.6 , Issue.1 , pp. 1-7
    • Butt, H.-J.1    Jaschke, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.