메뉴 건너뛰기




Volumn 7, Issue 1, 2013, Pages 63-70

Biocompatible, high precision, wideband, improved howland current source with lead-lag compensation

Author keywords

Bioimpedance; electrical impedance tomography (EIT); electrical stimulation; Howland current source

Indexed keywords

ALTERNATING CURRENT; BIO-IMPEDANCE; COMPENSATION STRATEGY; CURRENT SOURCES; ELECTRICAL IMPE DANCE TOMOGRAPHY (EIT); ELECTRICAL STIMULATIONS; HIGH FREQUENCY OUTPUT; PRECISION DELIVERY;

EID: 84875054926     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2012.2199114     Document Type: Article
Times cited : (106)

References (30)
  • 2
    • 84858677019 scopus 로고
    • Impedance & admittance transformations using operational amplifiers
    • D. H. Sheingold, "Impedance & admittance transformations using operational amplifiers," Lightning Empiricist, vol. 12, no. 1, p. 7, 1964
    • (1964) Lightning Empiricist , vol.12 , Issue.1 , pp. 7
    • Sheingold, D.H.1
  • 3
    • 0033999537 scopus 로고    scopus 로고
    • A comparison of modified Howland circuits as current generators with current mirror type circuits
    • DOI 10.1088/0967-3334/21/1/301, PII S0967333400098853
    • P. Bertemes-Filho, B. Brown, and A. Wilson, "A comparison of modified Howland circuits as current generators with current mirror type circuits," Physiol. Meas., vol. 21, pp. 1-6, 2000 (Pubitemid 30120664)
    • (2000) Physiological Measurement , vol.21 , Issue.1 , pp. 1-6
    • Bertemes-Filho, P.1    Brown, B.H.2    Wilson, A.J.3
  • 5
    • 74949107202 scopus 로고    scopus 로고
    • Circuit and coil design for in-vitro magnetic neural stimulation systems
    • Oct.
    • E. Basham, Z. Yang, and W. Liu, "Circuit and coil design for in-vitro magnetic neural stimulation systems," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 5, pp. 321-331, Oct. 2009
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.5 , pp. 321-331
    • Basham, E.1    Yang, Z.2    Liu, W.3
  • 6
    • 77952959018 scopus 로고    scopus 로고
    • An active approach for charge balancing in functional electrical stimulation
    • Jun.
    • K. Sooksood, T. Stieglitz, and M. Ortmanns, "An active approach for charge balancing in functional electrical stimulation," IEEE Trans. Biomed. Circuits Syst., vol. 4, no. 3, pp. 162-170, Jun. 2010
    • (2010) IEEE Trans. Biomed. Circuits Syst. , vol.4 , Issue.3 , pp. 162-170
    • Sooksood, K.1    Stieglitz, T.2    Ortmanns, M.3
  • 7
    • 84861633326 scopus 로고    scopus 로고
    • Tissue Characterisation Using an Impedance Spectroscopy Probe
    • Univ. Sheffield, Sheffield, U.K.
    • P. B. Filho, "Tissue Characterisation Using an Impedance Spectroscopy Probe," Ph.D. dissertation, Dept. Med. Phys. and Clin. Psych., Univ. Sheffield, Sheffield, U.K., 2002
    • (2002) Ph.D. Dissertation, Dept. Med. Phys. and Clin. Psych.
    • Filho, P.B.1
  • 8
    • 77950589809 scopus 로고    scopus 로고
    • Comparison of three current sources for single-electrode capacitance measurement
    • Mar.
    • D. X. Chen, X. Deng, andW. Q. Yang, "Comparison of three current sources for single-electrode capacitance measurement," Rev. Sci. Instrum., vol. 81, no. 3, Mar. 2010
    • (2010) Rev. Sci. Instrum. , vol.81 , Issue.3
    • Chen, D.X.1    Deng, X.2    Yang, A.Q.3
  • 9
    • 0038100605 scopus 로고    scopus 로고
    • Current source design for electrical impedance tomography
    • DOI 10.1088/0967-3334/24/2/361, PII S0967333403542034
    • A. S. Ross, G. J. Saulnier, J. C. Newell, and D. Isaacson, "Current source design for electrical impedance tomography," Physiol. Meas., vol. 24, no. 2, pp. 509-516, 2003 (Pubitemid 36648415)
    • (2003) Physiological Measurement , vol.24 , Issue.2 , pp. 509-516
    • Ross, A.S.1    Saulnier, G.J.2    Newell, J.C.3    Isaacson, D.4
  • 10
    • 34447092724 scopus 로고    scopus 로고
    • Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
    • DOI 10.1088/0967-3334/28/7/S14, PII S0967333407405457, S14
    • T. I. Oh, E. J. Woo, and D. Holder, "Multi-frequency EIT systemwith radially symmetric architecture: KHU mark1," Physiol.Meas., vol. 28, no. 7, pp. S183-S196, 2007 (Pubitemid 47028481)
    • (2007) Physiological Measurement , vol.28 , Issue.7
    • Oh, T.I.1    Woo, E.J.2    Holder, D.3
  • 12
    • 79551481198 scopus 로고    scopus 로고
    • In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray
    • Feb.
    • A. S. Tucker, E. A. Ross, J. Paugh-Miller, and R. J. Sadleir, "In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray," Physiol. Meas., vol. 32, no. 2, pp. 151-165, Feb. 2011
    • (2011) Physiol. Meas. , vol.32 , Issue.2 , pp. 151-165
    • Tucker, A.S.1    Ross, E.A.2    Paugh-Miller, J.3    Sadleir, R.J.4
  • 13
    • 0029819404 scopus 로고    scopus 로고
    • Current approaches to analogue instrumentation design in electrical impedance tomography
    • DOI 10.1088/0967-3334/17/4/001
    • K. G. Boone and D. S. Holder, "Current approaches to analogue instrumentation design in electrical impedance tomography," Physiol.Meas., vol. 17, no. 4, pp. 229-247, 1996 (Pubitemid 26400521)
    • (1996) Physiological Measurement , vol.17 , Issue.4 , pp. 229-247
    • Boone, K.G.1    Holder, D.S.2
  • 14
    • 70350441296 scopus 로고    scopus 로고
    • Comparison of a new integrated current source with the modified Howland circuit for EIT applications
    • H. Hong, M. Rahal, A. Demosthenous, and R. H. Bayford, "Comparison of a new integrated current source with the modified Howland circuit for EIT applications," Physiol. Meas., vol. 30, pp. 999-1007, 2009
    • (2009) Physiol. Meas. , vol.30 , pp. 999-1007
    • Hong, H.1    Rahal, M.2    Demosthenous, A.3    Bayford, R.H.4
  • 15
    • 45749087766 scopus 로고    scopus 로고
    • Low-noise current excitation sub-system for medical EIT
    • DOI 10.1088/0967-3334/29/6/S15, PII S0967333408667854
    • M. Rafiei-Naeini and H. McCann, "Low-noise current excitation subsystem formedical EIT," Physiol.Meas., vol. 29, no. 6, pp. S173-S184, 2008 (Pubitemid 351875547)
    • (2008) Physiological Measurement , vol.29 , Issue.6
    • Rafiei-Naeini, M.1    McCann, H.2
  • 16
    • 45749152617 scopus 로고    scopus 로고
    • On-electrode autonomous current generator for multi-frequency EIT
    • DOI 10.1088/0967-3334/29/6/S17, PII S0967333408666265
    • I. Jivet and B. Dragoi, "On-electrode autonomous current generator for multi-frequency EIT," Physiol. Meas., vol. 29, pp. S193-201, 2008 (Pubitemid 351875549)
    • (2008) Physiological Measurement , vol.29 , Issue.6
    • Jivet, I.1    Dragoi, B.2
  • 17
    • 34447101159 scopus 로고    scopus 로고
    • A review of errors in multi-frequency EIT instrumentation
    • DOI 10.1088/0967-3334/28/7/S15, PII S0967333407405007, S15
    • A. McEwan, G. Cusick, and D. S. Holder, "A review of errors in multifrequency EIT instrumentation," Physiol. Meas., vol. 28, no. 7, pp. S197-S215, 2007 (Pubitemid 47028482)
    • (2007) Physiological Measurement , vol.28 , Issue.7
    • McEwan, A.1    Cusick, G.2    Holder, D.S.3
  • 20
    • 84863827734 scopus 로고    scopus 로고
    • A comprehensive study of the Howland current source
    • Santa Clara, CA, Jan. 29 AN-1515
    • R. A. Pease, "A comprehensive study of the Howland current source," National Semiconductor, Santa Clara, CA, Jan. 29, 2008, AN-1515
    • (2008) National Semiconductor
    • Pease, R.A.1
  • 22
    • 0026904806 scopus 로고
    • A comparison of two approaches to feedback circuit analysis
    • P. J. Hurst, "A comparison of two approaches to feedback circuit analysis," IEEE Trans. Educ., vol. 35, no. 3, pp. 253-261, 1992
    • (1992) IEEE Trans. Educ. , vol.35 , Issue.3 , pp. 253-261
    • Hurst, P.J.1
  • 23
    • 0038519322 scopus 로고
    • Tame those versatile current-source circuits
    • Oct.
    • J. Steele and T. Green, "Tame those versatile current-source circuits," Electron. Des., pp. 61-72, Oct. 1992
    • (1992) Electron. Des. , pp. 61-72
    • Steele, J.1    Green, T.2
  • 25
    • 0024719927 scopus 로고
    • Null double injection and the extra element theorem
    • DOI 10.1109/13.34149
    • R. D. Middlebrook, "Null double injection and the extra element theorem," IEEE Trans. Educ., vol. 32, no. 3, pp. 167-180, Aug. 1989 (Pubitemid 20617697)
    • (1989) IEEE Transactions on Education , vol.32 , Issue.3 , pp. 167-180
    • Middlebrook, R.D.1
  • 29
    • 0031834864 scopus 로고    scopus 로고
    • Patient-instrument connection errors in bioelectrical impedance measurement
    • DOI 10.1088/0967-3334/19/2/015, PII S0967333498874789
    • F. al-Hatib, "Patient-instrument connection errors in bioelectrical impedance measurement," Physiol. Meas., vol. 19, no. 2, pp. 285-296, May 1998 (Pubitemid 28247618)
    • (1998) Physiological Measurement , vol.19 , Issue.2 , pp. 285-296
    • Al-Hatib, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.