-
1
-
-
0037671253
-
Electrical safety
-
4th ed. Hoboken, NJ:Wiley
-
W. H. Olson, , J. G. Webster, Ed., "Electrical safety," in Medical Instrumentation: Application and Design, 4th ed. Hoboken, NJ:Wiley, 2010, pp. 638-675
-
(2010)
Medical Instrumentation: Application and Design
, pp. 638-675
-
-
Olson, W.H.1
Webster, J.G.2
-
2
-
-
84858677019
-
Impedance & admittance transformations using operational amplifiers
-
D. H. Sheingold, "Impedance & admittance transformations using operational amplifiers," Lightning Empiricist, vol. 12, no. 1, p. 7, 1964
-
(1964)
Lightning Empiricist
, vol.12
, Issue.1
, pp. 7
-
-
Sheingold, D.H.1
-
3
-
-
0033999537
-
A comparison of modified Howland circuits as current generators with current mirror type circuits
-
DOI 10.1088/0967-3334/21/1/301, PII S0967333400098853
-
P. Bertemes-Filho, B. Brown, and A. Wilson, "A comparison of modified Howland circuits as current generators with current mirror type circuits," Physiol. Meas., vol. 21, pp. 1-6, 2000 (Pubitemid 30120664)
-
(2000)
Physiological Measurement
, vol.21
, Issue.1
, pp. 1-6
-
-
Bertemes-Filho, P.1
Brown, B.H.2
Wilson, A.J.3
-
4
-
-
63649085539
-
Practical considerations for the use of a Howland current source for neuro-stimulation
-
Nov.
-
P. Pouliquen, J. Vogelstein, and R. Etienne-Cummings, "Practical considerations for the use of a Howland current source for neuro-stimulation, " in Proc. IEEE Biomedical Circuits and Systems Conf., Nov. 2008, pp. 33-36
-
(2008)
Proc. IEEE Biomedical Circuits and Systems Conf.
, pp. 33-36
-
-
Pouliquen, P.1
Vogelstein, J.2
Etienne-Cummings, R.3
-
5
-
-
74949107202
-
Circuit and coil design for in-vitro magnetic neural stimulation systems
-
Oct.
-
E. Basham, Z. Yang, and W. Liu, "Circuit and coil design for in-vitro magnetic neural stimulation systems," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 5, pp. 321-331, Oct. 2009
-
(2009)
IEEE Trans. Biomed. Circuits Syst.
, vol.3
, Issue.5
, pp. 321-331
-
-
Basham, E.1
Yang, Z.2
Liu, W.3
-
6
-
-
77952959018
-
An active approach for charge balancing in functional electrical stimulation
-
Jun.
-
K. Sooksood, T. Stieglitz, and M. Ortmanns, "An active approach for charge balancing in functional electrical stimulation," IEEE Trans. Biomed. Circuits Syst., vol. 4, no. 3, pp. 162-170, Jun. 2010
-
(2010)
IEEE Trans. Biomed. Circuits Syst.
, vol.4
, Issue.3
, pp. 162-170
-
-
Sooksood, K.1
Stieglitz, T.2
Ortmanns, M.3
-
7
-
-
84861633326
-
Tissue Characterisation Using an Impedance Spectroscopy Probe
-
Univ. Sheffield, Sheffield, U.K.
-
P. B. Filho, "Tissue Characterisation Using an Impedance Spectroscopy Probe," Ph.D. dissertation, Dept. Med. Phys. and Clin. Psych., Univ. Sheffield, Sheffield, U.K., 2002
-
(2002)
Ph.D. Dissertation, Dept. Med. Phys. and Clin. Psych.
-
-
Filho, P.B.1
-
8
-
-
77950589809
-
Comparison of three current sources for single-electrode capacitance measurement
-
Mar.
-
D. X. Chen, X. Deng, andW. Q. Yang, "Comparison of three current sources for single-electrode capacitance measurement," Rev. Sci. Instrum., vol. 81, no. 3, Mar. 2010
-
(2010)
Rev. Sci. Instrum.
, vol.81
, Issue.3
-
-
Chen, D.X.1
Deng, X.2
Yang, A.Q.3
-
9
-
-
0038100605
-
Current source design for electrical impedance tomography
-
DOI 10.1088/0967-3334/24/2/361, PII S0967333403542034
-
A. S. Ross, G. J. Saulnier, J. C. Newell, and D. Isaacson, "Current source design for electrical impedance tomography," Physiol. Meas., vol. 24, no. 2, pp. 509-516, 2003 (Pubitemid 36648415)
-
(2003)
Physiological Measurement
, vol.24
, Issue.2
, pp. 509-516
-
-
Ross, A.S.1
Saulnier, G.J.2
Newell, J.C.3
Isaacson, D.4
-
10
-
-
34447092724
-
Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
-
DOI 10.1088/0967-3334/28/7/S14, PII S0967333407405457, S14
-
T. I. Oh, E. J. Woo, and D. Holder, "Multi-frequency EIT systemwith radially symmetric architecture: KHU mark1," Physiol.Meas., vol. 28, no. 7, pp. S183-S196, 2007 (Pubitemid 47028481)
-
(2007)
Physiological Measurement
, vol.28
, Issue.7
-
-
Oh, T.I.1
Woo, E.J.2
Holder, D.3
-
12
-
-
79551481198
-
In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray
-
Feb.
-
A. S. Tucker, E. A. Ross, J. Paugh-Miller, and R. J. Sadleir, "In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray," Physiol. Meas., vol. 32, no. 2, pp. 151-165, Feb. 2011
-
(2011)
Physiol. Meas.
, vol.32
, Issue.2
, pp. 151-165
-
-
Tucker, A.S.1
Ross, E.A.2
Paugh-Miller, J.3
Sadleir, R.J.4
-
13
-
-
0029819404
-
Current approaches to analogue instrumentation design in electrical impedance tomography
-
DOI 10.1088/0967-3334/17/4/001
-
K. G. Boone and D. S. Holder, "Current approaches to analogue instrumentation design in electrical impedance tomography," Physiol.Meas., vol. 17, no. 4, pp. 229-247, 1996 (Pubitemid 26400521)
-
(1996)
Physiological Measurement
, vol.17
, Issue.4
, pp. 229-247
-
-
Boone, K.G.1
Holder, D.S.2
-
14
-
-
70350441296
-
Comparison of a new integrated current source with the modified Howland circuit for EIT applications
-
H. Hong, M. Rahal, A. Demosthenous, and R. H. Bayford, "Comparison of a new integrated current source with the modified Howland circuit for EIT applications," Physiol. Meas., vol. 30, pp. 999-1007, 2009
-
(2009)
Physiol. Meas.
, vol.30
, pp. 999-1007
-
-
Hong, H.1
Rahal, M.2
Demosthenous, A.3
Bayford, R.H.4
-
15
-
-
45749087766
-
Low-noise current excitation sub-system for medical EIT
-
DOI 10.1088/0967-3334/29/6/S15, PII S0967333408667854
-
M. Rafiei-Naeini and H. McCann, "Low-noise current excitation subsystem formedical EIT," Physiol.Meas., vol. 29, no. 6, pp. S173-S184, 2008 (Pubitemid 351875547)
-
(2008)
Physiological Measurement
, vol.29
, Issue.6
-
-
Rafiei-Naeini, M.1
McCann, H.2
-
16
-
-
45749152617
-
On-electrode autonomous current generator for multi-frequency EIT
-
DOI 10.1088/0967-3334/29/6/S17, PII S0967333408666265
-
I. Jivet and B. Dragoi, "On-electrode autonomous current generator for multi-frequency EIT," Physiol. Meas., vol. 29, pp. S193-201, 2008 (Pubitemid 351875549)
-
(2008)
Physiological Measurement
, vol.29
, Issue.6
-
-
Jivet, I.1
Dragoi, B.2
-
17
-
-
34447101159
-
A review of errors in multi-frequency EIT instrumentation
-
DOI 10.1088/0967-3334/28/7/S15, PII S0967333407405007, S15
-
A. McEwan, G. Cusick, and D. S. Holder, "A review of errors in multifrequency EIT instrumentation," Physiol. Meas., vol. 28, no. 7, pp. S197-S215, 2007 (Pubitemid 47028482)
-
(2007)
Physiological Measurement
, vol.28
, Issue.7
-
-
McEwan, A.1
Cusick, G.2
Holder, D.S.3
-
18
-
-
84875051809
-
-
Rev. H, Analog Devices, Norwood, MA
-
AD9850: CMOS, 125 MHz Complete DDS Synthesizer, Rev. H, Analog Devices, Norwood, MA, 2004
-
(2004)
AD9850: CMOS, 125 MHz Complete DDS Synthesizer
-
-
-
19
-
-
34447102203
-
EIT instrumentation
-
London, U.K.: Inst. Physics Publishing
-
G. J. Saulnier, , D. Holder, Ed., "EIT instrumentation," in Electrical Impedance Tomography: Methods, History and Applications. London, U.K.: Inst. Physics Publishing, 2005, pp. 67-104
-
(2005)
Electrical Impedance Tomography: Methods, History and Applications
, pp. 67-104
-
-
Saulnier, G.J.1
Holder, D.2
-
20
-
-
84863827734
-
A comprehensive study of the Howland current source
-
Santa Clara, CA, Jan. 29 AN-1515
-
R. A. Pease, "A comprehensive study of the Howland current source," National Semiconductor, Santa Clara, CA, Jan. 29, 2008, AN-1515
-
(2008)
National Semiconductor
-
-
Pease, R.A.1
-
21
-
-
0003417349
-
-
5th ed. New York: Wiley
-
P.R.Gray, P. J. Hurst, S. H. Lewis, andR.G.Meyer, Analysis and Design of Analog Integrated Circuits, 5th ed. New York: Wiley, 2009
-
(2009)
Analysis and Design of Analog Integrated Circuits
-
-
Gray, P.R.1
Hurst, P.J.2
Lewis, S.H.3
Meyer, R.G.4
-
22
-
-
0026904806
-
A comparison of two approaches to feedback circuit analysis
-
P. J. Hurst, "A comparison of two approaches to feedback circuit analysis," IEEE Trans. Educ., vol. 35, no. 3, pp. 253-261, 1992
-
(1992)
IEEE Trans. Educ.
, vol.35
, Issue.3
, pp. 253-261
-
-
Hurst, P.J.1
-
23
-
-
0038519322
-
Tame those versatile current-source circuits
-
Oct.
-
J. Steele and T. Green, "Tame those versatile current-source circuits," Electron. Des., pp. 61-72, Oct. 1992
-
(1992)
Electron. Des.
, pp. 61-72
-
-
Steele, J.1
Green, T.2
-
24
-
-
84875055711
-
-
Rev. E, Texas Instruments Incorporated, Dallas, TX, Dec. SBOS251E
-
OPA847: Wideband, Ultra-Low Noise, Voltage-Feedback Operational Amplifier With Shutdown, Rev. E, Texas Instruments Incorporated, Dallas, TX, Dec. 2008, SBOS251E
-
(2008)
OPA847: Wideband, Ultra-Low Noise, Voltage-Feedback Operational Amplifier with Shutdown
-
-
-
25
-
-
0024719927
-
Null double injection and the extra element theorem
-
DOI 10.1109/13.34149
-
R. D. Middlebrook, "Null double injection and the extra element theorem," IEEE Trans. Educ., vol. 32, no. 3, pp. 167-180, Aug. 1989 (Pubitemid 20617697)
-
(1989)
IEEE Transactions on Education
, vol.32
, Issue.3
, pp. 167-180
-
-
Middlebrook, R.D.1
-
27
-
-
0035129588
-
Striving for small-signal stability
-
DOI 10.1109/101.900125
-
B. M. Tian, V. Visvanathan, J. Hantgan, and K. Kundert, "Striving for small-signal stability," IEEE Circuits Devices Mag., vol. 17, no. 1, pp. 31-41, Jan. 2001 (Pubitemid 32189066)
-
(2001)
IEEE Circuits and Devices Magazine
, vol.17
, Issue.1
, pp. 31-41
-
-
Tian, M.1
Visvanathan, V.2
Hantgan, J.3
Kundert, K.4
-
28
-
-
51849138457
-
Capacitive-compensated current source used in electrical impedance tomography
-
Gdansk, Poland, Jun.
-
P. Bertemes-Filho, R. Lima, and M. Amato, "Capacitive-compensated current source used in electrical impedance tomography," in Proc. 12th Int. Conf. Electrical Bioimpedance and 5th Electrical Impedance Tomography, Gdansk, Poland, Jun. 2004, vol. 2, pp. 644-647
-
(2004)
Proc. 12th Int. Conf. Electrical Bioimpedance and 5th Electrical Impedance Tomography
, vol.2
, pp. 644-647
-
-
Bertemes-Filho, P.1
Lima, R.2
Amato, M.3
-
29
-
-
0031834864
-
Patient-instrument connection errors in bioelectrical impedance measurement
-
DOI 10.1088/0967-3334/19/2/015, PII S0967333498874789
-
F. al-Hatib, "Patient-instrument connection errors in bioelectrical impedance measurement," Physiol. Meas., vol. 19, no. 2, pp. 285-296, May 1998 (Pubitemid 28247618)
-
(1998)
Physiological Measurement
, vol.19
, Issue.2
, pp. 285-296
-
-
Al-Hatib, F.1
-
30
-
-
0028486188
-
ACT3: A high-speed, high-precision electrical impedance tomograph
-
DOI 10.1109/10.310086
-
R. D. Cook, G. J. Saulnier, D. G. Gisser, J. C. Goble, J. C. Newell, and D. Isaacson, "ACT3: A high-speed, high-precision electrical impedance tomograph," IEEE Trans. Biomed. Eng., vol. 41, no. 8, pp. 713-722, 1994. (Pubitemid 24273254)
-
(1994)
IEEE Transactions on Biomedical Engineering
, vol.41
, Issue.8
, pp. 713-722
-
-
Cook, R.D.1
Saulnier, G.J.2
Gisser, D.G.3
Goble, J.C.4
Newell, J.C.5
Isaacson, D.6
|