메뉴 건너뛰기




Volumn 32, Issue 2, 2011, Pages 151-165

In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray

Author keywords

Abdominal haemorrhage; Electrical impedance tomography; Electrode array; Flow rate; Noninvasive monitoring; Peritoneal dialysis

Indexed keywords

DATA ACQUISITION; DIALYSIS; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; FLOW RATE;

EID: 79551481198     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/32/2/001     Document Type: Article
Times cited : (10)

References (42)
  • 1
    • 0030657934 scopus 로고    scopus 로고
    • Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    • Adler A, Amyot R, Guardo R, Bates J H T and Berthiaum y 1997 Monitoring changes in lung air and liquid volumes with electrical impedance tomography J. Appl. Physiol. 83 1762-7
    • (1997) J. Appl. Physiol. , vol.83 , pp. 1762-1767
    • Adler, A.1    Amyot, R.2    Guardo, R.3    Bates, J.H.T.4    Berthiaum, Y.5
  • 5
    • 0036192609 scopus 로고    scopus 로고
    • Intraperitoneal blood missed on a FAST examination using portable ultrasound
    • Blaivas M and Theodoro D 2002 Intraperitoneal blood missed on a FAST examination using portable ultrasound Am. J. Emerg. Med. 20 105-7
    • (2002) Am. J. Emerg. Med. , vol.20 , pp. 105-107
    • Blaivas, M.1    Theodoro, D.2
  • 7
    • 84980085014 scopus 로고
    • A generalization of reciprocal theorem
    • Carson J R 1924 A generalization of reciprocal theorem Bell Syst. Tech. J. 3 393-9
    • (1924) Bell Syst. Tech. J , vol.3 , pp. 393-399
    • Carson, J.R.1
  • 9
    • 0025337946 scopus 로고
    • Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography
    • Cheng K S, Simske S J, Isaacson D, Newell J C and Gisser D G 1990 Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography IEEE Trans. Biomed. Eng. 37 60-5
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 60-65
    • Cheng, K.S.1    Simske, S.J.2    Isaacson, D.3    Newell, J.C.4    Gisser, D.G.5
  • 10
    • 0036591483 scopus 로고    scopus 로고
    • Weighted regularization in electrical impedance tomography with applications to acute cerebral stroke
    • Clay M and Ferree T 2002 Weighted regularization in electrical impedance tomography with applications to acute cerebral stroke IEEE Trans. Med. Imaging 21 629-37
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 629-637
    • Clay, M.1    Ferree, T.2
  • 12
    • 0037978025 scopus 로고    scopus 로고
    • Technology-driven triage of abdominal trauma: The emerging era of nonoperative management
    • Demetriades D and Velmahos G 2003 Technology-driven triage of abdominal trauma: the emerging era of nonoperative management Annu. Rev. Med. 54 1-15
    • (2003) Annu. Rev. Med. , vol.54 , pp. 1-15
    • Demetriades, D.1    Velmahos, G.2
  • 13
    • 0024602999 scopus 로고
    • Diagnostic peritoneal lavage: Questions and answers
    • Feied C 1989 Diagnostic peritoneal lavage: questions and answers Postgrad. Med. 85 40-549
    • (1989) Postgrad. Med. , vol.85 , pp. 40-549
    • Feied, C.1
  • 15
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • Geselowitz D B 1971 An application of electrocardiographic lead theory to impedance plethysmography IEEE Trans. Biomed. Eng. 18 38-41
    • (1971) IEEE Trans. Biomed. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 16
    • 0023570429 scopus 로고
    • The truncated SVD as a method for regularization
    • Hansen P C 1987 The truncated SVD as a method for regularization BIT 27 543-53
    • (1987) BIT , vol.27 , pp. 543-553
    • Hansen, P.C.1
  • 17
    • 0001632418 scopus 로고
    • The use of the L-curve in the regularization of discrete ill-posed problems
    • Hansen P C and O'Leary D P 1993 The use of the L-curve in the regularization of discrete ill-posed problems SIAM J. Sci. Comput. 14 1487-503
    • (1993) SIAM J. Sci. Comput. , vol.14 , pp. 1487-1503
    • Hansen, P.C.1    O'Leary, D.P.2
  • 18
    • 0025222295 scopus 로고
    • Diagnostic peritoneal lavage: Accuracy in predicting necessary laparotomy following blunt and penetrating trauma
    • Henneman P L, Marx J A, Moore E E, Cantrill S V and Ammons L A 1990 Diagnostic peritoneal lavage: accuracy in predicting necessary laparotomy following blunt and penetrating trauma J. Trauma 30 1345-55
    • (1990) J. Trauma. , vol.30 , pp. 1345-1355
    • Henneman, P.L.1    Marx, J.A.2    Moore, E.E.3    Cantrill, S.V.4    Ammons, L.A.5
  • 20
    • 0015301269 scopus 로고
    • A vector derivation useful in impedance plethymographic field calculations
    • Lehr J 1972 A vector derivation useful in impedance plethymographic field calculations IEEE Trans. Biomed. Eng. 19 156-7
    • (1972) IEEE Trans. Biomed. Eng. , vol.19 , pp. 156-157
    • Lehr, J.1
  • 23
    • 0028935312 scopus 로고
    • The dependence of EIT images on the assumed initial conductivity distribution: A study of pelvic imaging
    • Meeson S, Killingback A L T and Blott B H 1995 The dependence of EIT images on the assumed initial conductivity distribution: a study of pelvic imaging Phys. Med. Biol. 40 643-57
    • (1995) Phys. Med. Biol. , vol.40 , pp. 643-657
    • Meeson, S.1    Killingback, A.L.T.2    Blott, B.H.3
  • 24
    • 0021892133 scopus 로고
    • Electrical impedance computed tomography based on a finite element model
    • Murai T and Kagawa y 1985 Electrical impedance computed tomography based on a finite element model IEEE Trans. Biomed. Eng. 32 177-84
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , pp. 177-184
    • Murai, T.1    Kagawa, Y.2
  • 25
    • 0024231306 scopus 로고
    • Aspects of instrumentation design for impedance imaging
    • Murphy D and Rolfe P 1988 Aspects of instrumentation design for impedance imaging Clin. Phys. Physiol. Meas. 9 5-14
    • (1988) Clin. Phys. Physiol. Meas. , vol.9 , pp. 5-14
    • Murphy, D.1    Rolfe, P.2
  • 27
    • 0005430160 scopus 로고
    • Abdominal injuries
    • Odling-Smee W 1984 Abdominal injuries Surgery 15 348-53
    • (1984) Surgery , vol.15 , pp. 348-353
    • Odling-Smee, W.1
  • 28
    • 63649113281 scopus 로고    scopus 로고
    • Normalization of a spatially variant image reconstruction problem in electrical impedance tomography using system blurring properties
    • Oh S, Tang T, Tucker A S and Sadleir R J 2009 Normalization of a spatially variant image reconstruction problem in electrical impedance tomography using system blurring properties Physiol. Meas. 30 275-89
    • (2009) Physiol. Meas. , vol.30 , pp. 275-289
    • Oh, S.1    Tang, T.2    Tucker, A.S.3    Sadleir, R.J.4
  • 29
    • 0027319470 scopus 로고
    • Prospective evaluation of surgeons' use of ultrasound in the evaluation of trauma patients
    • Rozycki G S, Ochsner M G, Jaffin J H and Champion H R 1993 Prospective evaluation of surgeons' use of ultrasound in the evaluation of trauma patients J. Trauma 34 516-27
    • (1993) J. Trauma. , vol.34 , pp. 516-527
    • Rozycki, G.S.1    Ochsner, M.G.2    Jaffin, J.H.3    Champion, H.R.4
  • 30
    • 0031789144 scopus 로고    scopus 로고
    • Quantification of blood volume by electrical impedance tomography using a tissue-equivalent phantom
    • Sadleir R and Fox R 1998 Quantification of blood volume by electrical impedance tomography using a tissue-equivalent phantom Physiol. Meas. 19 501-16
    • (1998) Physiol. Meas. , vol.19 , pp. 501-516
    • Sadleir, R.1    Fox, R.2
  • 31
    • 0035066201 scopus 로고    scopus 로고
    • Detection and quantification of intraperitoneal fluid using electrical impedance tomography
    • Sadleir R and Fox R 2001 Detection and quantification of intraperitoneal fluid using electrical impedance tomography IEEE Trans. Biomed. Eng. 48 484-91
    • (2001) IEEE Trans. Biomed. Eng. , vol.48 , pp. 484-491
    • Sadleir, R.1    Fox, R.2
  • 32
    • 51849093392 scopus 로고    scopus 로고
    • Imaging and quantification of anomaly volume using an eight-electrode 'hemiarray' EIT reconstruction method
    • Sadleir R J, Zhang S U, Tucker A S and Oh S 2008 Imaging and quantification of anomaly volume using an eight-electrode 'hemiarray' EIT reconstruction method Physiol. Meas. 29 913-27
    • (2008) Physiol. Meas. , vol.29 , pp. 913-927
    • Sadleir, R.J.1    Zhang, S.U.2    Tucker, A.S.3    Oh, S.4
  • 33
    • 34447102203 scopus 로고    scopus 로고
    • EIT instrumentation
    • ed D S Holder Bristol: Institute of Physics Publishing
    • Saulnier G J 2005 EIT instrumentation Electrical Impedance Tomography ed D S Holder (Bristol: Institute of Physics Publishing) pp 67-104
    • (2005) Electrical Impedance Tomography , pp. 67-104
    • Saulnier, G.J.1
  • 34
    • 0032033364 scopus 로고    scopus 로고
    • Current patterns and electrode types for single-source electrical impedance tomography of the thorax
    • Schuessler T F and Bates J H 1998 Current patterns and electrode types for single-source electrical impedance tomography of the thorax Ann. Biomed. Eng. 26 253-9
    • (1998) Ann. Biomed. Eng. , vol.26 , pp. 253-259
    • Schuessler, T.F.1    Bates, J.H.2
  • 35
    • 0023072056 scopus 로고
    • Theoretical limits to sensitivity and resolution in impedance imaging
    • Seagar A D, Barber D C and Brown B H 1987 Theoretical limits to sensitivity and resolution in impedance imaging Clin. Phys. Physiol. Meas. 8 13-31
    • (1987) Clin. Phys. Physiol. Meas. , vol.8 , pp. 13-31
    • Seagar, A.D.1    Barber, D.C.2    Brown, B.H.3
  • 37
    • 0033061651 scopus 로고    scopus 로고
    • Oral contrast solution and computed tomography for blunt abdominal trauma: A randomized study
    • Stafford R E, McGonigal M D, Weigelt J A and Johnson T J 1999 Oral contrast solution and computed tomography for blunt abdominal trauma: a randomized study Arch. Surg. 134 622-7
    • (1999) Arch. Surg. , vol.134 , pp. 622-627
    • Stafford, R.E.1    McGonigal, M.D.2    Weigelt, J.A.3    Johnson, T.J.4
  • 40
    • 0035118995 scopus 로고    scopus 로고
    • Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank
    • Tidswell A T, Gibson A, Bayford R H and Holder D S 2001a Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank Physiol. Meas. 22 177-85
    • (2001) Physiol. Meas. , vol.22 , pp. 177-185
    • Tidswell, A.T.1    Gibson, A.2    Bayford, R.H.3    Holder, D.S.4
  • 41
    • 0035722843 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography of human brain activity
    • Tidswell T, Gibson A, Bayford R H and Holder D S 2001b Three-dimensional electrical impedance tomography of human brain activity Neuroimage 13 283-94
    • (2001) Neuroimage , vol.13 , pp. 283-294
    • Tidswell, T.1    Gibson, A.2    Bayford, R.H.3    Holder, D.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.