메뉴 건너뛰기




Volumn 30, Issue 10, 2009, Pages 999-1007

Comparison of a new integrated current source with the modified howland circuit for EIT applications

Author keywords

Current source; Electrical impedance tomography (EIT)

Indexed keywords

ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; TIMING CIRCUITS;

EID: 70350441296     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/30/10/001     Document Type: Article
Times cited : (51)

References (16)
  • 1
    • 33748171065 scopus 로고    scopus 로고
    • Bioimpedance tomography (electrical impedance tomography)
    • Bayford R 2006 Bioimpedance tomography (electrical impedance tomography) Annu. Rev. Biomed. Eng. 8 63-91
    • (2006) Annu. Rev. Biomed. Eng. , vol.8 , Issue.1 , pp. 63-91
    • Bayford, R.1
  • 3
    • 0033999537 scopus 로고    scopus 로고
    • A comparison of modified Howland circuits as current generators with current mirror type circuit
    • Bertermes-Filho P, Brown B H and Wilson A J 2000 A comparison of modified Howland circuits as current generators with current mirror type circuit Physiol. Meas. 21 1-6
    • (2000) Physiol. Meas. , vol.21 , Issue.1 , pp. 1-6
    • Bertermes-Filho, P.1    Brown, B.H.2    Wilson, A.J.3
  • 5
    • 0023087764 scopus 로고
    • The Sheffield data collection system
    • Brown B H and Seagar A D 1987 The Sheffield data collection system Clin. Phys. Physiol. Meas. 8 (Suppl. 1A) 91-7
    • (1987) Clin. Phys. Physiol. Meas. , vol.8 , Issue.SUPPL. 1A , pp. 91-97
    • Brown, B.H.1    Seagar, A.D.2
  • 6
    • 0029831174 scopus 로고    scopus 로고
    • A parallel broadband real-time system for electrical impedance tomography
    • Casas O, Rosell J, Bragós R, Lozano A and Riu P J 1996 A parallel broadband real-time system for electrical impedance tomography Physiol. Meas. 17 (Suppl. 4A) A1-6
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL. 4A
    • Casas, O.1    Rosell, J.2    Bragós, R.3    Lozano, A.4    Riu, P.J.5
  • 10
    • 34447101159 scopus 로고    scopus 로고
    • A review of errors in multi-frequency EIT instrumentation
    • McEwan A, Cusick G and Holder D S 2007 A review of errors in multi-frequency EIT instrumentation Physiol. Meas. 28 S197-215
    • (2007) Physiol. Meas. , vol.28 , Issue.7
    • McEwan, A.1    Cusick, G.2    Holder, D.S.3
  • 15
    • 0038100605 scopus 로고    scopus 로고
    • Current source design for electrical impedance tomography
    • DOI 10.1088/0967-3334/24/2/361, PII S0967333403542034
    • Ross A S, Saulnier G J, Newell J C and Isaacson D 2003 Current source design for electrical impedance tomography Physiol. Meas. 24 509-16 (Pubitemid 36648415)
    • (2003) Physiological Measurement , vol.24 , Issue.2 , pp. 509-516
    • Ross, A.S.1    Saulnier, G.J.2    Newell, J.C.3    Isaacson, D.4
  • 16
    • 0019635874 scopus 로고
    • A low-distortion bipolar feedback current amplifier technique
    • Wilson B 1981 A low-distortion bipolar feedback current amplifier technique Proc. IEEE 69 1514-5
    • (1981) Proc. IEEE , vol.69 , Issue.11 , pp. 1514-1515
    • Wilson, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.