메뉴 건너뛰기




Volumn 19, Issue 2, 1998, Pages 285-296

Patient-instrument connection errors in bioelectrical impedance measurement

Author keywords

Bioelectrical impedance; Impedance spectroscopy; Instrumentation; Measurement errors; Patient instrument interface

Indexed keywords

CABLES; DIGITAL ARITHMETIC; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; MEASUREMENT ERRORS; VOLTAGE REGULATORS;

EID: 0031834864     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/19/2/015     Document Type: Article
Times cited : (25)

References (29)
  • 1
    • 0027560146 scopus 로고
    • Complex bioimpedance measurement system for the frequency range from 5 Hz to 1 MHz
    • Ackman J J 1993 Complex bioimpedance measurement system for the frequency range from 5 Hz to 1 MHz Ann. Biomed. Eng. 21 135-46
    • (1993) Ann. Biomed. Eng. , vol.21 , pp. 135-146
    • Ackman, J.J.1
  • 2
    • 0345250097 scopus 로고
    • Some thoughts regarding electrical bioimpedance and its clinical use
    • Baker L 1993 Some thoughts regarding electrical bioimpedance and its clinical use J. Clin. Eng. 18 221-3
    • (1993) J. Clin. Eng. , vol.18 , pp. 221-223
    • Baker, L.1
  • 3
    • 0008583292 scopus 로고
    • A model of the effect of variations in contact and skin impedance on electrical impedance tomography measurement artefacts
    • Boone K G and Holder D S 1995 A model of the effect of variations in contact and skin impedance on electrical impedance tomography measurement artefacts Innov. Technol. Biol. Med. 16 62-70
    • (1995) Innov. Technol. Biol. Med. , vol.16 , pp. 62-70
    • Boone, K.G.1    Holder, D.S.2
  • 4
    • 0029819404 scopus 로고    scopus 로고
    • Current approaches to analogue instrumentation design in electrical impedance tomography
    • _1996 Current approaches to analogue instrumentation design in electrical impedance tomography Physiol. Meas. 17 229-47
    • (1996) Physiol. Meas. , vol.17 , pp. 229-247
  • 5
    • 0029988236 scopus 로고    scopus 로고
    • Water distribution in insulin-dependent diabetes mellitus in various states of metabolic control
    • Brizzolara A, Barbieri M P, Adezati I and Viviani G L 1997 Water distribution in insulin-dependent diabetes mellitus in various states of metabolic control Eur J. Endocrinol. 135 609-15
    • (1997) Eur J. Endocrinol. , vol.135 , pp. 609-615
    • Brizzolara, A.1    Barbieri, M.P.2    Adezati, I.3    Viviani, G.L.4
  • 6
    • 0029918355 scopus 로고    scopus 로고
    • Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans
    • Cornish B H, Ward L C, Thomas B J, Jebb S A and Elia M 1996 Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans Eur. J. Clin. Nutr. 50 159-64
    • (1996) Eur. J. Clin. Nutr. , vol.50 , pp. 159-164
    • Cornish, B.H.1    Ward, L.C.2    Thomas, B.J.3    Jebb, S.A.4    Elia, M.5
  • 7
    • 0026504863 scopus 로고
    • Loss of total body water and extracellular water assessed by multifrequency impedance
    • Deurenberg P and Schouten F J M 1992 Loss of total body water and extracellular water assessed by multifrequency impedance Eur. J. Clin. Nutr 46 247-55
    • (1992) Eur. J. Clin. Nutr , vol.46 , pp. 247-255
    • Deurenberg, P.1    Schouten, F.J.M.2
  • 8
    • 0027595080 scopus 로고
    • Electrical impedance spectroscopic monitoring of body compartmental volume changes
    • Gerth W A and Watke C M 1993 Electrical impedance spectroscopic monitoring of body compartmental volume changes J. Clin. Eng. 18 253-60
    • (1993) J. Clin. Eng. , vol.18 , pp. 253-260
    • Gerth, W.A.1    Watke, C.M.2
  • 10
    • 0028881307 scopus 로고
    • Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients
    • Hannan W J, Cowen S J, Plester C E, Fearon K C and de Beau A 1995 Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients Clin. Sci. 89 651-8
    • (1995) Clin. Sci. , vol.89 , pp. 651-658
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.E.3    Fearon, K.C.4    De Beau, A.5
  • 12
    • 0002993830 scopus 로고
    • The electrode and electronic interface in an EIT spectroscopy system
    • Lu L and Brown B H 1994 The electrode and electronic interface in an EIT spectroscopy system Innov. Technol. Biol Med. 15 98-103
    • (1994) Innov. Technol. Biol Med. , vol.15 , pp. 98-103
    • Lu, L.1    Brown, B.H.2
  • 13
    • 0026638245 scopus 로고
    • Impedance spectroscopy
    • Macdonald R J 1992 Impedance spectroscopy Ann Biomed. Eng. 20 289-305
    • (1992) Ann Biomed. Eng. , vol.20 , pp. 289-305
    • Macdonald, R.J.1
  • 14
    • 0025483042 scopus 로고
    • High-quality recording of bioelectric events. Part 1 Interference reduction, theory and practice
    • Metting van Rijn A C, Peper A and Grimbergen C A 1990 High-quality recording of bioelectric events. Part 1 Interference reduction, theory and practice Med. Biol Eng. Comput 28 389-97
    • (1990) Med. Biol Eng. Comput , vol.28 , pp. 389-397
    • Van Metting Rijn, A.C.1    Peper, A.2    Grimbergen, C.A.3
  • 15
    • 0029741650 scopus 로고    scopus 로고
    • Overview of bioelectrical impedance analysers
    • Oldham N M 1996 Overview of bioelectrical impedance analysers Am. J. Clin. Nutr 64 (suppl) 405S-412S
    • (1996) Am. J. Clin. Nutr , vol.64 , Issue.SUPPL.
    • Oldham, N.M.1
  • 16
    • 0024118972 scopus 로고
    • Interference-rejection characteristics of biopotential amplifiers: A comparative analysis
    • Pallas-Areny R 1988 Interference-rejection characteristics of biopotential amplifiers: a comparative analysis IEEE Trans. Biomed. Eng 35 953-9
    • (1988) IEEE Trans. Biomed. Eng , vol.35 , pp. 953-959
    • Pallas-Areny, R.1
  • 17
    • 0027715230 scopus 로고
    • AC instrumentation amplifier for bioimpedance measurements
    • Pallas-Areny R and Webster J G 1993 AC instrumentation amplifier for bioimpedance measurements IEEE Trans. Biomed. Eng. 40 830-3
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 830-833
    • Pallas-Areny, R.1    Webster, J.G.2
  • 20
    • 0029823582 scopus 로고    scopus 로고
    • Broadband quasi-differential multifrequency electrical impedance imaging system
    • Riu P J, Bragos R and Rosell J 1996 Broadband quasi-differential multifrequency electrical impedance imaging system Physiol. Meas. 17 (suppl 4A) A39-A47
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL. 4A
    • Riu, P.J.1    Bragos, R.2    Rosell, J.3
  • 21
    • 0029394737 scopus 로고
    • Multi-frequency static imaging in electrical impedance tomography: Part 1 instrumentation requirements
    • Riu P J, Rosell J, Lozano A and Pallas-Areny 1995 Multi-frequency static imaging in electrical impedance tomography: part 1 instrumentation requirements Med. Biol. Eng. Comput. 33 784-92
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 784-792
    • Riu, P.J.1    Rosell, J.2    Lozano, A.3    Pallas-Areny4
  • 22
    • 0026479324 scopus 로고
    • Common-mode feedback in electrical impedance tomography
    • Rosell J and Riu P 1992 Common-mode feedback in electrical impedance tomography Clin. Phys. Physiol. Meas. 13 (suppl A) 11-14
    • (1992) Clin. Phys. Physiol. Meas. , vol.13 , Issue.SUPPL. A , pp. 11-14
    • Rosell, J.1    Riu, P.2
  • 24
    • 0028356064 scopus 로고
    • Comments on a comparison of four commercial systems used to measure whole-body electrical impedance
    • Smith D N 1994 Comments on a comparison of four commercial systems used to measure whole-body electrical impedance Physiol. Meas. 15 231-4
    • (1994) Physiol. Meas. , vol.15 , pp. 231-234
    • Smith, D.N.1
  • 25
    • 6844263858 scopus 로고
    • Tissue impedivity and electro-mathematical modelling of bioimpedances
    • _1995 Tissue impedivity and electro-mathematical modelling of bioimpedances Innov. Technol. Biol. Med. 16 695-702
    • (1995) Innov. Technol. Biol. Med. , vol.16 , pp. 695-702
  • 26
    • 0027361223 scopus 로고
    • A comparison of four commercial systems used to measure whole-body electrical impedance
    • Smye S, Sutcliffe J and Pitt E 1993 A comparison of four commercial systems used to measure whole-body electrical impedance Physiol Meas. 14 473-8
    • (1993) Physiol Meas. , vol.14 , pp. 473-478
    • Smye, S.1    Sutcliffe, J.2    Pitt, E.3
  • 27
    • 0020858683 scopus 로고
    • Errors in four-electrode impedance plethysmography
    • Swanson D K and Webster J G 1983 Errors in four-electrode impedance plethysmography Med. Biol. Eng. Comput. 21 674-80
    • (1983) Med. Biol. Eng. Comput. , vol.21 , pp. 674-680
    • Swanson, D.K.1    Webster, J.G.2
  • 28
    • 0020752224 scopus 로고
    • Equipment using an impedance technique for automatic recording of fluid-volume changes during hemodialysis
    • Tedner B 1983 Equipment using an impedance technique for automatic recording of fluid-volume changes during hemodialysis Med. Biol Eng. Comput. 21 285-90
    • (1983) Med. Biol Eng. Comput. , vol.21 , pp. 285-290
    • Tedner, B.1