메뉴 건너뛰기




Volumn 14, Issue , 2013, Pages

2D-fluoroscopic based navigation for Gamma 3 nail insertion versus conventional procedure- A feasibility study

Author keywords

Cephalomedullary nail; Computer assisted surgery; Femoral fracture; Fluoroscopic navigation; Gamma nail; Geriatric traumatology; Navigation; Proximal femoral nailing; Radiation exposure; Trochanteric fracture

Indexed keywords

ACCURACY; ARTICLE; CLINICAL EFFECTIVENESS; COMPUTER ASSISTED TOMOGRAPHY; FEMUR; FLUOROSCOPY; GAMMA3 NAIL; INTERMETHOD COMPARISON; INTRAMEDULLARY NAIL; INTRAMEDULLARY NAILING; OPERATION DURATION; POSTOPERATIVE PERIOD; PRACTICE GUIDELINE; RADIATION EXPOSURE; TWO DIMENSIONAL FLUOROSCOPY;

EID: 84874868102     PISSN: None     EISSN: 14712474     Source Type: Journal    
DOI: 10.1186/1471-2474-14-74     Document Type: Article
Times cited : (9)

References (17)
  • 1
    • 84874877922 scopus 로고    scopus 로고
    • Bundesauswertung zum Verfahrensjahr Gottingen: AQUA - Institut für angewandte Qualitätsförderung und Forschung im Gesundheitswesen GmbH 2010 23469380
    • Bundesauswertung zum Verfahrensjahr, Hüftgelenksnahe Frakturen Gottingen: AQUA-Institut für angewandte Qualitätsförderung und Forschung im Gesundheitswesen GmbH 2010 2009 23469380
    • (2009) Hüftgelenksnahe Frakturen
  • 2
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries
    • DOI 10.1016/S0140-6736(04)15433-0
    • Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Berrington de Gonzalez A, Darby S, Lancet 2004 363 9406 345 351 10.1016/S0140-6736(04)15433-0 15070562 (Pubitemid 38169539)
    • (2004) Lancet , vol.363 , Issue.9406 , pp. 345-351
    • De Gonzalez, A.B.1    Darby, S.2
  • 3
    • 33746012646 scopus 로고    scopus 로고
    • The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures-The experience in Singapore
    • DOI 10.1016/j.injury.2006.03.002, PII S0020138306001252
    • The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures-The experience in Singapore. Chong KW, Wong MK, Rikhraj IS, Howe TS, Injury 2006 37 8 755 762 10.1016/j.injury.2006.03.002 16765957 (Pubitemid 44066984)
    • (2006) Injury , vol.37 , Issue.8 , pp. 755-762
    • Chong, K.W.1    Wong, M.K.2    Rikhraj, I.S.3    Howe, T.S.4
  • 4
    • 21244434304 scopus 로고    scopus 로고
    • Radiation exposure to the hands of orthopaedic surgeons: Are we underestimating the risk?
    • DOI 10.1007/s00402-005-0807-5
    • Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk? Hafez MA, Smith RM, Matthews SJ, Kalap G, Sherman KP, Arch Orthop Trauma Surg 2005 125 5 330 335 10.1007/s00402-005-0807-5 15843947 (Pubitemid 40895354)
    • (2005) Archives of Orthopaedic and Trauma Surgery , vol.125 , Issue.5 , pp. 330-335
    • Hafez, M.A.1    Smith, R.M.2    Matthews, S.J.3    Kalap, G.4    Sherman, K.P.5
  • 5
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?" Mehlman CT, DiPasquale TG, J Orthop Trauma 1997 11 6 392 398 10.1097/00005131-199708000-00002 9314144 (Pubitemid 127728684)
    • (1997) Journal of Orthopaedic Trauma , vol.11 , Issue.6 , pp. 392-398
    • Mehlman, C.T.1    DiPasquale, T.G.2
  • 6
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • 7608228
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM, J Bone Joint Surg Am 1995 77 7 1058 1064 7608228
    • (1995) J Bone Joint Surg Am , vol.77 , Issue.7 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3    Keggi, J.M.4
  • 7
    • 84864367875 scopus 로고    scopus 로고
    • Screw placement for acetabular fractures: Which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study
    • 10.1097/BOT.0b013e318234d443 22357092
    • Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study. Gras F, Marintschev I, Klos K, Muckley T, Hofmann GO, Kahler DM, J Orthop Trauma 2012 26 8 466 473 10.1097/BOT.0b013e318234d443 22357092
    • (2012) J Orthop Trauma , vol.26 , Issue.8 , pp. 466-473
    • Gras, F.1    Marintschev, I.2    Klos, K.3    Muckley, T.4    Hofmann, G.O.5    Kahler, D.M.6
  • 8
    • 77953903600 scopus 로고    scopus 로고
    • Sustentaculum tali screw placement for calcaneus fractures-different navigation procedures compared to the conventional technique
    • 10.1055/s-0029-1240973 20414866
    • Sustentaculum tali screw placement for calcaneus fractures-different navigation procedures compared to the conventional technique. Gras F, Marintschev I, Wilharm A, Lindner R, Klos K, Muckley T, Hofmann GO, Z Orthop Unfall 2010 148 3 309 318 10.1055/s-0029-1240973 20414866
    • (2010) Z Orthop Unfall , vol.148 , Issue.3 , pp. 309-318
    • Gras, F.1    Marintschev, I.2    Wilharm, A.3    Lindner, R.4    Klos, K.5    Muckley, T.6    Hofmann, G.O.7
  • 9
    • 84866903880 scopus 로고    scopus 로고
    • Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws: An experimental study
    • Sep 10.1007/s00113-010-1915-4 21327810
    • Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws: An experimental study. Muller MC, Belei P, de la Fuente M, Strake M, Kabir K, Weber O, Burger C, Radermacher K, Wirtz DC, Unfallchirurg 2012 115 9 802 810 Sep 10.1007/s00113-010-1915-4 21327810
    • (2012) Unfallchirurg , vol.115 , Issue.9 , pp. 802-810
    • Muller, M.C.1    Belei, P.2    De La Fuente, M.3    Strake, M.4    Kabir, K.5    Weber, O.6    Burger, C.7    Radermacher, K.8    Wirtz, D.C.9
  • 10
    • 79957636299 scopus 로고    scopus 로고
    • Evaluation of a 2D Fluoroscopy-Based Navigation System for Insertion of the Dynamic Hip Screw (DHS): An Experimental Study
    • 10.1055/s-0031-1273329 21506071
    • Evaluation of a 2D Fluoroscopy-Based Navigation System for Insertion of the Dynamic Hip Screw (DHS): an Experimental Study. Muller MC, Belei P, de la Fuente M, Strake M, Weber O, Burger C, Radermacher K, Wirtz DC, Rofo 2011 183 6 536 542 10.1055/s-0031-1273329 21506071
    • (2011) Rofo , vol.183 , Issue.6 , pp. 536-542
    • Muller, M.C.1    Belei, P.2    De La Fuente, M.3    Strake, M.4    Weber, O.5    Burger, C.6    Radermacher, K.7    Wirtz, D.C.8
  • 11
    • 0020684975 scopus 로고
    • Radiation exposure and associated risks to operating room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures
    • Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. Miller ME, Davis ML, MacClean CR, Davis JG, Smith BL, Humphries JR, J Bone Joint Surg Am 1983 65 1 1 4 6848524 (Pubitemid 13186226)
    • (1983) Journal of Bone and Joint Surgery - Series A , vol.65 , Issue.1 , pp. 1-4
    • Miller, M.E.1    Davis, M.L.2    MacClean, C.R.3
  • 12
    • 0025612507 scopus 로고
    • Shielding of the patient's gonads during intramedullary interlocking femoral nailing
    • 2254361
    • Shielding of the patient's gonads during intramedullary interlocking femoral nailing. Kwong LM, Johanson PH, Zinar DM, Lenihan MR, Herman MW, J Bone Joint Surg Am 1990 72 10 1523 1526 2254361
    • (1990) J Bone Joint Surg Am , vol.72 , Issue.10 , pp. 1523-1526
    • Kwong, L.M.1    Johanson, P.H.2    Zinar, D.M.3    Lenihan, M.R.4    Herman, M.W.5
  • 13
    • 77951974751 scopus 로고    scopus 로고
    • Pin track induced fractures around computer-assisted TKA
    • May 10.1016/j.otsr.2009.12.005 20488143
    • Pin track induced fractures around computer-assisted TKA. Beldame J, Boisrenoult P, Beaufils P, Orthop Traumatol Surg Res 2010 96 3 249 255 May 10.1016/j.otsr.2009.12.005 20488143
    • (2010) Orthop Traumatol Surg Res , vol.96 , Issue.3 , pp. 249-255
    • Beldame, J.1    Boisrenoult, P.2    Beaufils, P.3
  • 14
    • 33750300647 scopus 로고    scopus 로고
    • Eine neue doppelbohrbüchse zur navigierten schenkelhalsverschraubung: Entwicklung und evaluation
    • DOI 10.1007/s00113-006-1142-1
    • A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation. Kendoff D, Hufner T, Citak M, Maier C, Wesemeier F, Pearle A, Krettek C, Unfallchirurg 2006 109 10 875 880 10.1007/s00113-006-1142-1 17004045 (Pubitemid 44624512)
    • (2006) Unfallchirurg , vol.109 , Issue.10 , pp. 875-880
    • Kendoff, D.1    Hufner, T.2    Citak, M.3    Maier, C.4    Wesemeier, F.5    Pearle, A.6    Krettek, C.7
  • 17
    • 34250174736 scopus 로고    scopus 로고
    • Navigierte anbohrung der femurkopfnekrose. Experimentelle und klinische ergebnisse
    • DOI 10.1007/s00132-007-1086-3
    • Navigated drilling for femoral head necrosis. Experimental and clinical results. Beckmann J, Tingart M, Perlick L, Luring C, Grifka J, Anders S, Orthopade 2007 36 5 458 465 10.1007/s00132-007-1086-3 17468844 (Pubitemid 46895882)
    • (2007) Orthopade , vol.36 , Issue.5 , pp. 458-465
    • Beckmann, J.1    Tingart, M.2    Perlick, L.3    Luring, C.4    Grifka, J.5    Anders, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.