메뉴 건너뛰기




Volumn 183, Issue 6, 2011, Pages 536-542

Evaluation of a 2D fluoroscopy-based navigation system for insertion of the dynamic hip screw (DHS): An experimental study;Evaluation eines 2-D-Fluoroskopie-basierten Navigationssystems zur Implantation der dynamischen Hüftschraube (DHS): Eine experimentelle Studie

Author keywords

experimental study; extremities; femur; percutaneous; surgery; trauma

Indexed keywords

ARTICLE; BONE SCREW; COMPUTER ASSISTED RADIOGRAPHY; DYNAMIC HIP SCREW; FLUOROSCOPY; HUMAN; IMAGE ANALYSIS; INTRAOPERATIVE PERIOD; OPERATION DURATION; PRIORITY JOURNAL; TWO DIMENSIONAL FLUOROSCOPY;

EID: 79957636299     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0031-1273329     Document Type: Article
Times cited : (4)

References (30)
  • 1
    • 0033528550 scopus 로고    scopus 로고
    • Hip fractures in Finland between 1970 and 1997 and predictions for the future
    • DOI 10.1016/S0140-6736(98)04235-4
    • Kannus P, Niemi S, Parkkari J et al. Hip fractures in Finland between 1970 and 1977 and predictions for the future. Lancet 1999 353 802-805 (Pubitemid 29110406)
    • (1999) Lancet , vol.353 , Issue.9155 , pp. 802-805
    • Kannus, P.1    Niemi, S.2    Parkkari, J.3    Palvanen, M.4    Vuori, I.5    Jarvinen, M.6
  • 2
    • 0035513877 scopus 로고    scopus 로고
    • Die minimal-invasive Schraubenosteosynthese der medialen Schenkelhalsfraktur bei betagten Patienten
    • DOI 10.1007/s001040170034
    • Bosch U, Schreiber T, Skutek M et al. Die minimal-invasive Schraubenosteosynthese der medialen Schenkelhalsfraktur bei betagten Patienten. Chirurg 2001 72 1292-1297 (Pubitemid 33683569)
    • (2001) Chirurg , vol.72 , Issue.11 , pp. 1292-1297
    • Bosch, U.1    Schreiber, T.2    Skutek, M.3    Cserhati, P.4    Fekete, K.5    Krettek, C.6
  • 3
    • 0346727437 scopus 로고    scopus 로고
    • Predicting the mechanical outcome of femoral neck fractures fixed with cancellous screws: An in vivo study
    • Weinrobe M, Stankewich C J., Mueller B et al. Predicting the mechanical outcome of femoral neck fractures fixed with cancellous screws: an in vivo study. JOrthop Trauma 1998 12 27-36
    • (1998) JOrthop Trauma , vol.12 , pp. 27-36
    • Weinrobe, M.1    Stankewich, C.J.2    Mueller, B.3
  • 4
    • 0029012764 scopus 로고
    • The value of the Tip-Apex Distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner M R., Curtin S L., Lindskog D M. The value of the Tip-Apex Distance in predicting failure of fixation of peritrochanteric fractures of the hip. JBone Joint Surg 1995 77 1058-1064
    • (1995) JBone Joint Surg , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 6
    • 0029315622 scopus 로고
    • Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method
    • Lindequist S, Tornkvist M. Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method. JOrthop Trauma 1995 9 215-221
    • (1995) JOrthop Trauma , vol.9 , pp. 215-221
    • Lindequist, S.1    Tornkvist, M.2
  • 7
    • 19244369914 scopus 로고    scopus 로고
    • Intra- und perioperative komplikationen bei der stabilisierung von per- und subtrochantären femurfrakturen mittels PFN
    • DOI 10.1007/s00113-002-0416-5
    • Werner-Tutschku W, Lajtai G, Schmiedhuber G et al. Intra- und perioperative Komplikationen bei der Stabilisierung von per- und subtrochantren Femurfrakturen mittels PFN. Unfallchirurg 2002 105 881-885 (Pubitemid 36062215)
    • (2002) Unfallchirurg , vol.105 , Issue.10 , pp. 881-885
    • Werner-Tutschku, W.1    Lajtai, G.2    Schmiedhuber, G.3    Lang, T.4    Pirkl, C.5    Orthner, E.6
  • 8
    • 28744438421 scopus 로고    scopus 로고
    • Behandlungsergebnisse und komplikationen nach PFN-osteosynthese
    • DOI 10.1007/s00113-005-0962-8
    • Hohendorff B, Meyer P, Menezes D et al. Behandlungsergebnisse und Komplikationen nach PFN-Osteosynthese. Unfallchirurg 2005 108 938-953 (Pubitemid 41758360)
    • (2005) Unfallchirurg , vol.108 , Issue.11 , pp. 938-953
    • Hohendorff, B.1    Meyer, P.2    Menezes, D.3    Meier, L.4    Elke, R.5
  • 9
    • 33746012646 scopus 로고    scopus 로고
    • The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures-The experience in Singapore
    • DOI 10.1016/j.injury.2006.03.002, PII S0020138306001252
    • Chong K W., Wong M K., Rikhraj I S. et al. The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures - The experience in Singapore. Injury 2006 37 755-762 (Pubitemid 44066984)
    • (2006) Injury , vol.37 , Issue.8 , pp. 755-762
    • Chong, K.W.1    Wong, M.K.2    Rikhraj, I.S.3    Howe, T.S.4
  • 10
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries
    • DOI 10.1016/S0140-6736(04)15433-0
    • Berrington de Gonzalez A, Darby S. Risk of cancer from diagnostic x-rays: estimates for the UK and 14 other countries. Lancet 2004 363 345-351 (Pubitemid 38169539)
    • (2004) Lancet , vol.363 , Issue.9406 , pp. 345-351
    • De Gonzalez, A.B.1    Darby, S.2
  • 11
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
    • Mehlman C T., DiPasquale T G. Radiation exposure to the orthopaedic surgical team during fluoroscopy: how far away is far enough? JOrthop Trauma 1997 11 392-398 (Pubitemid 127728684)
    • (1997) Journal of Orthopaedic Trauma , vol.11 , Issue.6 , pp. 392-398
    • Mehlman, C.T.1    DiPasquale, T.G.2
  • 13
    • 2942585202 scopus 로고    scopus 로고
    • Basic principles of CAOS
    • Nolte L P., Beutler T. Basic principles of CAOS. Injury 2004 35 S-A6-S-A16
    • (2004) Injury , vol.35
    • Nolte, L.P.1    Beutler, T.2
  • 15
    • 66949172476 scopus 로고    scopus 로고
    • Vergleich zweier Navigationshilfen für CT-gesteuerte Interventionen unter besonderer Berücksichtigung der Nutzungseigenschaften der verwendeten Systeme
    • Schulz T, Röttger S, Bahner-Heyne E J. et al. Vergleich zweier Navigationshilfen für CT-gesteuerte Interventionen unter besonderer Berücksichtigung der Nutzungseigenschaften der verwendeten Systeme. Fortschr Röntgenstr 2009 181 564-572
    • (2009) Fortschr Röntgenstr , vol.181 , pp. 564-572
    • Schulz, T.1    Röttger, S.2    Bahner-Heyne, E.J.3
  • 16
    • 0025612507 scopus 로고
    • Shielding of the patient's gonads during intramedullary interlocking femoral nailing
    • Kwong L, Johanson P H., Zinar D M. et al. Shielding of the patient's gonads during intramedullary interlocking femoral nailing. JBone Joint Surg 1990 72 1523-1526
    • (1990) JBone Joint Surg , vol.72 , pp. 1523-1526
    • Kwong, L.1    Johanson, P.H.2    Zinar, D.M.3
  • 17
    • 79957643859 scopus 로고    scopus 로고
    • Stellenwert der 2D-Navigation bei der Osteosynthese von Schenkelhalsfrakturen
    • (online first)
    • Müller M C., Belei P, Wirtz D C. et al. Stellenwert der 2D-Navigation bei der Osteosynthese von Schenkelhalsfrakturen. Trauma Berufskrankheit 2010 (online first) 4
    • (2010) Trauma Berufskrankheit , vol.4
    • Müller, M.C.1    Belei, P.2    Wirtz, D.C.3
  • 20
    • 84881060183 scopus 로고    scopus 로고
    • Zero-dose C-arm navigation: An efficient approach based on virtual X-ray targeting
    • Fuente M de la, Belei P, Ohnsorge J et al. Zero-dose C-arm navigation: an efficient approach based on virtual X-ray targeting. Int J CARS 2 2007 2 249-250
    • (2007) Int J CARS 2 , vol.2 , pp. 249-250
    • De La, F.M.1    Belei, P.2    Ohnsorge, J.3
  • 21
    • 77957708301 scopus 로고    scopus 로고
    • Evaluation der Effizienz des Zero-Dose C-Arm-Navigations-Ansatzes
    • Barbe A G., Fuente M de la, Belei B et al. Evaluation der Effizienz des Zero-Dose C-Arm-Navigations-Ansatzes. Z Orthop Unfall 2010 148 554-558
    • (2010) Z Orthop Unfall , vol.148 , pp. 554-558
    • Barbe, A.G.1    De La, F.M.2    Belei, B.3
  • 22
    • 48249133605 scopus 로고    scopus 로고
    • Funktionalitt und Genauigkeit eines fluoroskopischen Navigationssystems zur Implantation von Hüftkopf-Oberflchenersatzprothesen: Eine Anatomiestudie
    • Gravius S, Belei P, Fuente M de la et al. Funktionalitt und Genauigkeit eines fluoroskopischen Navigationssystems zur Implantation von Hüftkopf-Oberflchenersatzprothesen: Eine Anatomiestudie. Z Orthop Unfall 2008 146 357-363
    • (2008) Z Orthop Unfall , vol.146 , pp. 357-363
    • Gravius, S.1    Belei, P.2    De La, F.M.3
  • 23
    • 50049107331 scopus 로고    scopus 로고
    • Navigation versus konventionelle manuelle Positionierung der Femurkomponente beim Oberflchenersatz der Hüfte: Erste experimentelle Erprobung
    • Gravius S, Belei P, Fuente M de la et al. Navigation versus konventionelle manuelle Positionierung der Femurkomponente beim Oberflchenersatz der Hüfte: erste experimentelle Erprobung. Biomed Tech 2008 53 204-212
    • (2008) Biomed Tech , vol.53 , pp. 204-212
    • Gravius, S.1    Belei, P.2    De La, F.M.3
  • 26
    • 0029315622 scopus 로고
    • Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method
    • Lindequist S, Tornkvist H. Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method. JOrthop Trauma 1995 9 215-221
    • (1995) JOrthop Trauma , vol.9 , pp. 215-221
    • Lindequist, S.1    Tornkvist, H.2
  • 27
    • 2542497793 scopus 로고    scopus 로고
    • Computer-guidance in percutaneous screw stabilization of the iliosacral joint
    • Arand M, Kinzl K, Gebhard F. Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res 2004 422 201-207 (Pubitemid 38685495)
    • (2004) Clinical Orthopaedics and Related Research , Issue.422 , pp. 201-207
    • Arand, M.1    Kinzl, L.2    Gebhard, F.3
  • 28
    • 33750300647 scopus 로고    scopus 로고
    • Eine neue doppelbohrbüchse zur navigierten schenkelhalsverschraubung: Entwicklung und evaluation
    • DOI 10.1007/s00113-006-1142-1
    • Kendoff D, Hüfner T, Citak M et al. Eine neue Doppelbohrbüchse zur navigierten Schenkelhalsverschraubung. Entwicklung und Evaluation. Unfallchirurg 2006 109 875-880 (Pubitemid 44624512)
    • (2006) Unfallchirurg , vol.109 , Issue.10 , pp. 875-880
    • Kendoff, D.1    Hufner, T.2    Citak, M.3    Maier, C.4    Wesemeier, F.5    Pearle, A.6    Krettek, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.