메뉴 건너뛰기




Volumn 96, Issue 3, 2010, Pages 249-255

Pin track induced fractures around computer-assisted TKA

Author keywords

Computer assisted surgery; Femur; Iatrogenic fracture; Robotic surgery complications; Total knee arthroplasty

Indexed keywords

AGED; ARTICLE; BODY MASS; BONE NAIL; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; DIAPHYSIS; FEMALE; FEMUR FRACTURE; FIXATION DEVICE; HUMAN; KNEE PAIN; KNEE RADIOGRAPHY; MALE; METAPHYSIS; OBESITY; PRIORITY JOURNAL; PROSTHESIS FAILURE; STRESS FRACTURE; TOTAL KNEE REPLACEMENT;

EID: 77951974751     PISSN: 18770568     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.otsr.2009.12.005     Document Type: Article
Times cited : (78)

References (17)
  • 1
    • 17144435044 scopus 로고    scopus 로고
    • Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study
    • Saragaglia D., Picard F., Chaussard C., Montbarbon E., Leitner F., and Cinquin P. Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87 (2001) 18-28
    • (2001) Rev Chir Orthop Reparatrice Appar Mot , vol.87 , pp. 18-28
    • Saragaglia, D.1    Picard, F.2    Chaussard, C.3    Montbarbon, E.4    Leitner, F.5    Cinquin, P.6
  • 2
    • 0036394724 scopus 로고    scopus 로고
    • Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients
    • Stulberg S.D., Loan P., and Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A Suppl. 2 (2002) 90-98
    • (2002) J Bone Joint Surg Am , vol.84 -A , Issue.SUPPL.-2 , pp. 90-98
    • Stulberg, S.D.1    Loan, P.2    Sarin, V.3
  • 3
    • 12344255623 scopus 로고    scopus 로고
    • The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty
    • Cossey A.J., and Spriggins A.J. The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty 20 (2005) 29-34
    • (2005) J Arthroplasty , vol.20 , pp. 29-34
    • Cossey, A.J.1    Spriggins, A.J.2
  • 4
    • 0035192870 scopus 로고    scopus 로고
    • Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation
    • Jenny J.Y., and Boeri C. Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87 (2001) 645-652
    • (2001) Rev Chir Orthop Reparatrice Appar Mot , vol.87 , pp. 645-652
    • Jenny, J.Y.1    Boeri, C.2
  • 5
    • 16244411067 scopus 로고    scopus 로고
    • Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation
    • Decking R., Markmann Y., Fuchs J., Puhl W., and Scharf H.P. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20 (2005) 282-288
    • (2005) J Arthroplasty , vol.20 , pp. 282-288
    • Decking, R.1    Markmann, Y.2    Fuchs, J.3    Puhl, W.4    Scharf, H.P.5
  • 7
    • 33748136386 scopus 로고    scopus 로고
    • Femoral stress fracture after computer navigated total knee arthroplasty
    • Ossendorf C., Fuchs B., and Koch P. Femoral stress fracture after computer navigated total knee arthroplasty. Knee 13 (2006) 397-399
    • (2006) Knee , vol.13 , pp. 397-399
    • Ossendorf, C.1    Fuchs, B.2    Koch, P.3
  • 8
    • 35348934218 scopus 로고    scopus 로고
    • Fractures associated with computer-navigated total knee arthroplasty. A report of two cases
    • Jung H.J., Jung Y.B., Song K.S., Park S.J., and Lee J.S. Fractures associated with computer-navigated total knee arthroplasty. A report of two cases. J Bone Joint Surg Am 89 (2007) 2280-2284
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2280-2284
    • Jung, H.J.1    Jung, Y.B.2    Song, K.S.3    Park, S.J.4    Lee, J.S.5
  • 9
    • 36849031282 scopus 로고    scopus 로고
    • Surgical site infection after total knee arthroplasty: a monocenter analysis of 923 first-intention implantations
    • Debarge R., Nicolle M.C., Pinaroli A., Ait Si Selmi T., and Neyret P. Surgical site infection after total knee arthroplasty: a monocenter analysis of 923 first-intention implantations. Rev Chir Orthop Reparatrice Appar Mot 93 (2007) 582-587
    • (2007) Rev Chir Orthop Reparatrice Appar Mot , vol.93 , pp. 582-587
    • Debarge, R.1    Nicolle, M.C.2    Pinaroli, A.3    Ait Si Selmi, T.4    Neyret, P.5
  • 10
    • 44949083609 scopus 로고    scopus 로고
    • Case report: femoral shaft fracture resulting from femoral tracker placement in navigated TKA
    • Bonutti P., Dethmers D., and Stiehl J.B. Case report: femoral shaft fracture resulting from femoral tracker placement in navigated TKA. Clin Orthop Relat Res 466 (2008) 1499-1502
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 1499-1502
    • Bonutti, P.1    Dethmers, D.2    Stiehl, J.B.3
  • 11
    • 38949126595 scopus 로고    scopus 로고
    • Periprosthetic femoral supracondylar fracture after total knee arthroplasty with navigation system
    • Li C.H., Chen T.H., Su Y.P., Shao P.C., Lee K.S., and Chen W.M. Periprosthetic femoral supracondylar fracture after total knee arthroplasty with navigation system. J Arthroplasty 23 (2008) 304-307
    • (2008) J Arthroplasty , vol.23 , pp. 304-307
    • Li, C.H.1    Chen, T.H.2    Su, Y.P.3    Shao, P.C.4    Lee, K.S.5    Chen, W.M.6
  • 12
    • 40749112731 scopus 로고    scopus 로고
    • Femoral fracture through a previous pin site after computer-assisted total knee arthroplasty
    • Wysocki R.W., Sheinkop M.B., Virkus W.W., and Della Valle C.J. Femoral fracture through a previous pin site after computer-assisted total knee arthroplasty. J Arthroplasty 23 (2008) 462-465
    • (2008) J Arthroplasty , vol.23 , pp. 462-465
    • Wysocki, R.W.1    Sheinkop, M.B.2    Virkus, W.W.3    Della Valle, C.J.4
  • 13
    • 0023225425 scopus 로고
    • Supracondylar fracture of the femur after total knee arthroplasty
    • Aaron R.K., and Scott R. Supracondylar fracture of the femur after total knee arthroplasty. Clin Orthop Relat Res (1987) 136-139
    • (1987) Clin Orthop Relat Res , pp. 136-139
    • Aaron, R.K.1    Scott, R.2
  • 15
    • 0025968284 scopus 로고
    • The effect of defect size on the stress concentration and fracture characteristics for a tubular torsional model with a transverse hole
    • Kuo R.F., Chao E.Y., Rim K., and Park J.B. The effect of defect size on the stress concentration and fracture characteristics for a tubular torsional model with a transverse hole. J Biomech 24 (1991) 147-155
    • (1991) J Biomech , vol.24 , pp. 147-155
    • Kuo, R.F.1    Chao, E.Y.2    Rim, K.3    Park, J.B.4
  • 16
    • 33846418406 scopus 로고    scopus 로고
    • Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports
    • Seon J.K., Song E.K., Yoon T.R., Seo H.Y., and Cho S.G. Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports. Knee Surg Sports Traumatol Arthrosc 15 (2007) 67-70
    • (2007) Knee Surg Sports Traumatol Arthrosc , vol.15 , pp. 67-70
    • Seon, J.K.1    Song, E.K.2    Yoon, T.R.3    Seo, H.Y.4    Cho, S.G.5
  • 17
    • 0025610753 scopus 로고
    • Structural consequences of transcortical holes in long bones loaded in torsion
    • Hipp J.A., Edgerton B.C., An K.N., and Hayes W.C. Structural consequences of transcortical holes in long bones loaded in torsion. J Biomech 23 (1990) 1261-1268
    • (1990) J Biomech , vol.23 , pp. 1261-1268
    • Hipp, J.A.1    Edgerton, B.C.2    An, K.N.3    Hayes, W.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.