메뉴 건너뛰기




Volumn 88, Issue 8, 2006, Pages 1748-1754

Computerized navigation for the internal fixation of femoral neck fractures

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BONE SCREW; CALIBRATION; CANNULATION; CLINICAL ARTICLE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER BASED NAVIGATION; DIAGNOSTIC VALUE; FEMALE; FEMUR NECK FRACTURE; FLUOROSCOPY; FRACTURE FIXATION; HUMAN; INTERMETHOD COMPARISON; MALE; OSTEOSYNTHESIS; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE; TREATMENT OUTCOME;

EID: 33746901218     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/JBJS.E.00137     Document Type: Article
Times cited : (83)

References (16)
  • 1
    • 0031771032 scopus 로고    scopus 로고
    • Femoral neck fracture fixation: A biomechanical study of two cannulated screw placement techniques
    • Booth KC, Donaldson KJ, Dai QG. Femoral neck fracture fixation: a biomechanical study of two cannulated screw placement techniques. Orthopedics. 1998; 21:1173.
    • (1998) Orthopedics , vol.21 , pp. 1173
    • Booth, K.C.1    Donaldson, K.J.2    Dai, Q.G.3
  • 2
    • 0032957728 scopus 로고    scopus 로고
    • Erratum
    • Erratum in: Orthopedics. 1999;22:477.
    • (1999) Orthopedics , vol.22 , pp. 477
  • 3
    • 0037350504 scopus 로고    scopus 로고
    • Subtrocanterich fracture after cannulated screw fixation of femoral neck fractures: A report of four cases
    • Kloen P, Rubel IF, Lyden JP, Helfet DL. Subtrocanterich fracture after cannulated screw fixation of femoral neck fractures: a report of four cases. J Orthop Trauma. 2003;17:225-9.
    • (2003) J Orthop Trauma , vol.17 , pp. 225-229
    • Kloen, P.1    Rubel, I.F.2    Lyden, J.P.3    Helfet, D.L.4
  • 5
    • 18944374772 scopus 로고    scopus 로고
    • The complications of displaced intracapsular fractures of the hip: The effect of screw positioning and angulation on fracture healing
    • Gurusamy K, Parker MJ, Rowlands TK. The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg Br. 2005;87:632-4.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 632-634
    • Gurusamy, K.1    Parker, M.J.2    Rowlands, T.K.3
  • 6
    • 0347003735 scopus 로고    scopus 로고
    • Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study
    • Selvan VT, Oakley MJ, Rangan A, Al-Lami MK. Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury. 2004;35:136-41.
    • (2004) Injury , vol.35 , pp. 136-141
    • Selvan, V.T.1    Oakley, M.J.2    Rangan, A.3    Al-Lami, M.K.4
  • 7
    • 0037247655 scopus 로고    scopus 로고
    • Sub- or intertrochanteric fracture following screw fixation of an intracapsular proximal femoral fracture: True complication or technical error?
    • Pelet S, Leyvraz PF, Garofalo R, Borens O, Mouhsine E. Sub- or intertrochanteric fracture following screw fixation of an intracapsular proximal femoral fracture: true complication or technical error? Swiss Surg. 2003;9:82-6.
    • (2003) Swiss Surg , vol.9 , pp. 82-86
    • Pelet, S.1    Leyvraz, P.F.2    Garofalo, R.3    Borens, O.4    Mouhsine, E.5
  • 8
    • 33746866423 scopus 로고    scopus 로고
    • Computer-assisted guidance systems improve accuracy and reduced radiation exposure for freehand fluoroscopic targeting. Basic Science Focus Forum
    • Oct 7; Hollywood, FL
    • Ricci WM, Kahler DM, Russel TA, Terrill-Grisoni L, Culley P. Computer-assisted guidance systems improve accuracy and reduced radiation exposure for freehand fluoroscopic targeting. Basic Science Focus Forum. Presented at the Annual Meeting of the Orthopaedic Trauma Association; 2004 Oct 7; Hollywood, FL.
    • (2004) Annual Meeting of the Orthopaedic Trauma Association
    • Ricci, W.M.1    Kahler, D.M.2    Russel, T.A.3    Terrill-Grisoni, L.4    Culley, P.5
  • 9
    • 2342574698 scopus 로고    scopus 로고
    • Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study
    • Suhm N, Messmer P, Zuna I, Jacob LA, Regazzoni P. Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study. Injury. 2004;35:567-74.
    • (2004) Injury , vol.35 , pp. 567-574
    • Suhm, N.1    Messmer, P.2    Zuna, I.3    Jacob, L.A.4    Regazzoni, P.5
  • 10
    • 17644405424 scopus 로고    scopus 로고
    • Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: A cadaver model
    • Collinge C, Coons D, Tornetta P, Aschenbrenner J. Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma. 2005; 19:254-8.
    • (2005) J Orthop Trauma , vol.19 , pp. 254-258
    • Collinge, C.1    Coons, D.2    Tornetta, P.3    Aschenbrenner, J.4
  • 11
    • 0003179093 scopus 로고    scopus 로고
    • Fracture and dislocation compendium
    • Committee of Coding and Classification of the Orthopaedic Trauma Association. Fracture and Dislocation Compendium. J Orthop Trauma. 1996;10(Suppl 1):315.
    • (1996) J Orthop Trauma , vol.10 , Issue.SUPPL. 1 , pp. 315
  • 12
    • 0000363188 scopus 로고
    • Low-angle fixation in fractures of the femoral neck
    • Garden RS. Low-angle fixation in fractures of the femoral neck. J Bone Joint Surg Br. 1961;43:647-63.
    • (1961) J Bone Joint Surg Br , vol.43 , pp. 647-663
    • Garden, R.S.1
  • 13
    • 0035707082 scopus 로고    scopus 로고
    • Computer-assisted implantation of total knee prostheses: A case-control comparative study with classical instrumentation
    • Jenny JY, Boeri C. Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg. 2001;6:217-20.
    • (2001) Comput Aided Surg , vol.6 , pp. 217-220
    • Jenny, J.Y.1    Boeri, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.