메뉴 건너뛰기




Volumn 13, Issue 4, 2013, Pages 1363-1370

Application of microfluidic device for lactic biosensor

Author keywords

Biosensor; lactic sensor; microfluidic; multi sensor; pH sensor

Indexed keywords

COMPUTER NUMERICAL CONTROL; DIFFERENTIAL PRESSURE METERS; FLEXIBLE SENSOR; FLUIDIC CHANNELS; MICRO-FLUIDIC DEVICES; MULTI SENSOR; POTENTIOMETRIC BIOSENSORS; REFERENCE ELECTRODES; RELATED FACTORS; SCREEN-PRINTED; SENSING FILMS; SPUTTERING SYSTEMS;

EID: 84874626254     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2012.2234552     Document Type: Article
Times cited : (16)

References (24)
  • 1
    • 76949103582 scopus 로고    scopus 로고
    • In-channel modification of biosensor electrodes integrated on a polycarbonate microfluidic chip for micro flow-injection amperometric determination of glucose
    • Y. Wang, Q. He, Y. Dong, and H. Chen, "In-channel modification of biosensor electrodes integrated on a polycarbonate microfluidic chip for micro flow-injection amperometric determination of glucose, " Sens. Actuators B, Chem., vol. 145, no. 1, pp. 553-560, 2009
    • (2009) Sens. Actuators B, Chem. , vol.145 , Issue.1 , pp. 553-560
    • Wang, Y.1    He, Q.2    Dong, Y.3    Chen, H.4
  • 2
    • 18044390709 scopus 로고    scopus 로고
    • Microfluidic immunosensor systems
    • DOI 10.1016/j.bios.2004.10.016, 20th Anniversary of Biosendors and Bioelectronics
    • A. Bange, H. B. Halsall, and W. R. Heineman, "Microfluidic immunosensor systems, " Biosens. Bioelectron., vol. 20, no. 12, pp. 2488-2503, 2005 (Pubitemid 40602185)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.12 , pp. 2488-2503
    • Bange, A.1    Halsall, H.B.2    Heineman, W.R.3
  • 3
    • 59249092120 scopus 로고    scopus 로고
    • Microfluidics: Applications for analytical purposes in chemistry and biochemistry
    • K. Ohno, K. Tachikawa, and A. Manz, "Microfluidics: Applications for analytical purposes in chemistry and biochemistry, " Electrophoresis, vol. 29, no. 22, pp. 4443-4453, 2008
    • (2008) Electrophoresis , vol.29 , Issue.22 , pp. 4443-4453
    • Ohno, K.1    Tachikawa, K.2    Manz, A.3
  • 4
    • 0842329030 scopus 로고    scopus 로고
    • An Integrated Approach to a Portable and Low-Cost Immunoassay for Resource-Poor Settings
    • DOI 10.1002/anie.200353016
    • S. K. Sia, V. Linder, B. A. Parviz, A. Siegel, and G. M. Whitesides, "An integrated approach to a portable and low-cost immunoassay for resource-poor settings, " Angewandte Chem. Int. Ed., vol. 43, no. 4, pp. 498-502, 2004 (Pubitemid 38168405)
    • (2004) Angewandte Chemie - International Edition , vol.43 , Issue.4 , pp. 498-502
    • Sia, S.K.1    Linder, V.2    Parviz, B.A.3    Siegel, A.4    Whitesides, G.M.5
  • 5
    • 0030649160 scopus 로고    scopus 로고
    • Simple and low cost fabrication of embedded micro-channels by using a new thick-film photoplastic
    • L. J. Guerin, M. Bossel, M. Demierre, S. Calmes, and P. Renaud, "Simple and low cost fabrication of embedded micro-channels by using a new thick-film photoplastic, " Sens. Actuators A., vol. 2, no. 6, pp. 1419-1422, 1997
    • (1997) Sens. Actuators A. , vol.2 , Issue.6 , pp. 1419-1422
    • Guerin, L.J.1    Bossel, M.2    Demierre, M.3    Calmes, S.4    Renaud, P.5
  • 6
    • 68849085937 scopus 로고    scopus 로고
    • Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay
    • Y. Lu, W. Shi, L. Jiang, J. Qin, and B. Lin, "Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay, " Electrophoresis, vol. 30, no. 9, pp. 1497-1500, 2009
    • (2009) Electrophoresis , vol.30 , Issue.9 , pp. 1497-1500
    • Lu, Y.1    Shi, W.2    Jiang, L.3    Qin, J.4    Lin, B.5
  • 7
    • 70349303094 scopus 로고    scopus 로고
    • Low cost and manufacturable complete microTAS for detecting bacteria
    • A. F. Budge, P. Mirer, A. Chatterjee, C. M. Klapperich, D. Chargin, and A. Sharon, "Low cost and manufacturable complete microTAS for detecting bacteria, " LabChip, vol. 9, no. 19, pp. 2803-2810, 2009
    • (2009) LabChip , vol.9 , Issue.19 , pp. 2803-2810
    • Budge, A.F.1    Mirer, P.2    Chatterjee, A.3    Klapperich, C.M.4    Chargin, D.5    Sharon, A.6
  • 8
    • 33645527362 scopus 로고    scopus 로고
    • Facile fabrication of microfluidic systems using electron beam lithography
    • A. Sarkar and R. Lal, "Facile fabrication of microfluidic systems using electron beam lithography, " LabChip., vol. 6, no. 2, pp. 310-315, 2006
    • (2006) LabChip. , vol.6 , Issue.2 , pp. 310-315
    • Sarkar, A.1    Lal, R.2
  • 10
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • S. K. Sia and G. M. Whitesides, "Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies, " Electrophoresis, vol. 24, no. 21, pp. 3563-3576, 2009
    • (2009) Electrophoresis , vol.24 , Issue.21 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2
  • 11
    • 29744439707 scopus 로고    scopus 로고
    • Microfluidics for processing surfaces and miniaturizing biological assays
    • DOI 10.1002/adma.200501129
    • E. Delamarche, D. Juncker, and H. Schmid, "Microfluidics for processing surfaces and miniaturizing biological assays, " Adv. Mater., vol. 17, no. 24, pp. 2911-2933, 2005 (Pubitemid 43026692)
    • (2005) Advanced Materials , vol.17 , Issue.24 , pp. 2911-2933
    • Delamarche, E.1    Juncker, D.2    Schmid, H.3
  • 12
    • 0035095801 scopus 로고    scopus 로고
    • Analysis of piezoelectric bimorphs and plates with segmented actuators
    • DOI 10.1016/S0263-8231(00)00052-5
    • S. S. Vel and R. C. Batra, "Analysis of piezoelectric bimorphs and plates with segmented actuators, " Thin-Walled Struct., vol. 39, no. 1, pp. 23-44, 2001 (Pubitemid 32196083)
    • (2001) Thin-Walled Structures , vol.39 , Issue.1 , pp. 23-44
    • Vel, S.S.1    Batra, R.C.2
  • 13
    • 19944418306 scopus 로고    scopus 로고
    • Sensing characteristics of ruthenium films fabricated by radio frequency sputtering
    • J. C. Chou, S. I. Liu, and S. H. Chen, "Sensing characteristics of ruthenium films fabricated by radio frequency sputtering, " Jap. J. Appl. Phys., vol. 44, no. 3, pp. 1403-1408, 2005
    • (2005) Jap. J. Appl. Phys. , vol.44 , Issue.3 , pp. 1403-1408
    • Chou, J.C.1    Liu, S.I.2    Chen, S.H.3
  • 14
    • 37549003643 scopus 로고    scopus 로고
    • Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system
    • Y. H. Liao and J. C. Chou, "Preparation and characteristics of ruthenium dioxide for pH array sensors with real-time measurement system, " Sens. Actuators B, vol. 128, no. 12, pp. 603-612, 2008
    • (2008) Sens. Actuators B , vol.128 , Issue.12 , pp. 603-612
    • Liao, Y.H.1    Chou, J.C.2
  • 15
    • 67650333378 scopus 로고    scopus 로고
    • Fabrication and application of rutheniumdoped titanium dioxide films as electrode material for ion-sensitive extended-gate FETs
    • Mar.
    • J. C. Chou and C. W. Chen, "Fabrication and application of rutheniumdoped titanium dioxide films as electrode material for ion-sensitive extended-gate FETs, " IEEE Sens. J., vol. 9, no. 3, pp. 277-284, Mar. 2009
    • (2009) IEEE Sens. J. , vol.9 , Issue.3 , pp. 277-284
    • Chou, J.C.1    Chen, C.W.2
  • 16
    • 63049117552 scopus 로고    scopus 로고
    • Material analysis of ruthenium-doped titanium dioxide sensing film and applied as calcium ion sensor
    • J. C. Chou and C. W. Chen, "Material analysis of ruthenium-doped titanium dioxide sensing film and applied as calcium ion sensor, " Sens. Lett., vol. 6, no. 6, pp. 983-986, 2008
    • (2008) Sens. Lett. , vol.6 , Issue.6 , pp. 983-986
    • Chou, J.C.1    Chen, C.W.2
  • 17
    • 3042825092 scopus 로고    scopus 로고
    • Using Polypyrrole as the contrast pH detector to fabricate a whole solid-state pH sensing device
    • Apr.
    • C. W. Pan, J. C. Chou, I. K. Kao, T. P. Sun, and S. K. Hsiung, "Using Polypyrrole as the contrast pH detector to fabricate a whole solid-state pH sensing device, " IEEE Sens. J., vol. 3, no. 2, pp. 164-170, Apr. 2003
    • (2003) IEEE Sens. J. , vol.3 , Issue.2 , pp. 164-170
    • Pan, C.W.1    Chou, J.C.2    Kao, I.K.3    Sun, T.P.4    Hsiung, S.K.5
  • 19
    • 0030597205 scopus 로고    scopus 로고
    • Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode
    • DOI 10.1016/0003-2670(96)00258-9, PII S0003267096002589
    • Z. Chen and P. W. Alexander, "Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode, " Anal. Chim. Acta, vol. 332, no. 2, pp. 187-192, 1996 (Pubitemid 26358900)
    • (1996) Analytica Chimica Acta , vol.332 , Issue.2-3 , pp. 187-192
    • Chen, Z.1    Alexander, P.W.2
  • 20
    • 0028195438 scopus 로고
    • Comparison of the hysteresis of Ta2O5 and Si3N4 pH-sensing insulators
    • L. Bousse, S. Mostarshed, B. Schoot, and N. F. Rooij, "Comparison of the hysteresis of Ta2O5 and Si3N4 pH-sensing insulators, " Sens. Actuators B, vol. 17, no. 2, pp. 157-164, 1994
    • (1994) Sens. Actuators B , vol.17 , Issue.2 , pp. 157-164
    • Bousse, L.1    Mostarshed, S.2    Schoot, B.3    Rooij, N.F.4
  • 21
    • 78651350629 scopus 로고    scopus 로고
    • Ru incorporation on marked enhancement of diffusion resistance of multi-component alloy barrier layers
    • S. Y. Chang, C. Y. Wang, M. K. Chen, and C. E. Li, "Ru incorporation on marked enhancement of diffusion resistance of multi-component alloy barrier layers, " J. Alloys Comp., vol. 509, no. 3, pp. 85-89, 2011
    • (2011) J. Alloys Comp. , vol.509 , Issue.3 , pp. 85-89
    • Chang, S.Y.1    Wang, C.Y.2    Chen, M.K.3    Li, C.E.4
  • 22
    • 84874584820 scopus 로고
    • Potentiometric enzyme electrode for lactate
    • T. Shinbo and M. Sugiura, "Potentiometric enzyme electrode for lactate, " Anal. Chem., vol. 519, pp. 100-104, 1984
    • (1984) Anal. Chem. , vol.519 , pp. 100-104
    • Shinbo, T.1    Sugiura, M.2
  • 23
    • 0037058664 scopus 로고    scopus 로고
    • Microfluidic device integrated with pre-reactor and dual enzyme-modified microelectrodes for monitoring in vivo glucose and lactate
    • DOI 10.1016/S0925-4005(02)00249-6, PII S0925400502002496
    • R. Kurita, K. Hayashi, X. Fan, K. Yamamoto, T. Kato, and O. Niwa, "Microfluidic device integrated with pre-reactor and dual enzymemodified microelectrodes for monitoring in vivo glucose and lactate, " Sens. Actuators B, vol. 87, no. 2, pp. 296-303, 2002 (Pubitemid 35282276)
    • (2002) Sensors and Actuators, B: Chemical , vol.87 , Issue.2 , pp. 296-303
    • Kurita, R.1    Hayashi, K.2    Fan, X.3    Yamamoto, K.4    Kato, T.5    Niwa, O.6
  • 24
    • 31044435107 scopus 로고    scopus 로고
    • Miniaturized one-chip electrochemical sensing device integrated with a dialysis membrane and double thin-layer flow channels for measuring blood samples
    • DOI 10.1016/j.bios.2005.07.016, PII S0956566305002228
    • R. Kurita, N. Yabumoto, and O. Niwa, "Miniaturized one-chip electrochemical sensing device integrated with a dialysis membrane and double thin-layer flow channels for measuring blood samples, " Biosens. Bioelectron., vol. 21, pp. 1649-1653, Aug. 2006. (Pubitemid 43122034)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.8 , pp. 1649-1653
    • Kurita, R.1    Yabumoto, N.2    Niwa, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.