메뉴 건너뛰기




Volumn 178, Issue , 2013, Pages 418-425

Investigation of the hydrogen response characteristics for sol-gel-derived Pd-doped, Fe-doped and PEG-added SnO2 nano-thin films

Author keywords

Bulk modification; Gas sensing properties; SnO2 thin film; Sol gel

Indexed keywords

BULK MODIFICATION; CO AND CH; CORRELATION COEFFICIENT; FE-DOPED; GAS RESPONSE; GAS SENSING PROPERTIES; LINEAR RESPONSE; LOW TEMPERATURES; MASS SENSOR; NANO-THIN FILMS; PEG-400; REPRODUCIBILITIES; RESPONSE CHARACTERISTIC; RESPONSE MAGNITUDE; RESPONSE PROFILE; SOL-GEL TECHNOLOGY;

EID: 84873824635     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.12.101     Document Type: Article
Times cited : (19)

References (24)
  • 4
    • 57949107361 scopus 로고    scopus 로고
    • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II-selected sensor test results
    • L. Boon-Brett, J. Bousek, and P. Moretto Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: part II-selected sensor test results International Journal of Hydrogen Energy 34 2009 562 571
    • (2009) International Journal of Hydrogen Energy , vol.34 , pp. 562-571
    • Boon-Brett, L.1    Bousek, J.2    Moretto, P.3
  • 6
    • 0035923362 scopus 로고    scopus 로고
    • Theory of gas-diffusion controlled sensitivity for thin film semiconductor gas sensor
    • DOI 10.1016/S0925-4005(01)00890-5, PII S0925400501008905
    • G. Sakai, N. Matsunaga, K. Shimanoe, and N. Yamazoe Theory of gas-diffusion controlled sensitivity for thin film semiconductor gas sensor Sensors and Actuators B 80 2001 125 131 (Pubitemid 32951428)
    • (2001) Sensors and Actuators, B: Chemical , vol.80 , Issue.2 , pp. 125-131
    • Sakai, G.1    Matsunaga, N.2    Shimanoe, K.3    Yamazoe, N.4
  • 9
    • 0037086394 scopus 로고    scopus 로고
    • Diffusion equation-based study of thin film semiconductor gas sensor-response transient
    • DOI 10.1016/S0925-4005(01)01043-7, PII S0925400501010437
    • N. Matsunaga, G. Sakai, K. Shimanoe, and N. Yamazoe Diffusion equation-based study of thin film semiconductor gas sensor-response transient Sensors and Actuators B 83 2002 216 221 (Pubitemid 34232248)
    • (2002) Sensors and Actuators, B: Chemical , vol.83 , Issue.1-3 , pp. 216-221
    • Matsunaga, N.1    Sakai, G.2    Shimanoe, K.3    Yamazoe, N.4
  • 12
    • 0034322663 scopus 로고    scopus 로고
    • Preparation, characterisation and applications of thin films for gas sensors prepared by cheap chemical method
    • P. Siciliano Preparation, characterisation and applications of thin films for gas sensors prepared by cheap chemical method Sensors and Actuators B 70 2000 153 164 (Pubitemid 32058199)
    • (2000) Sens. Actuators, B , vol.B70 , Issue.1-3 , pp. 153-164
    • Siciliano, P.1
  • 13
    • 77958152720 scopus 로고    scopus 로고
    • Ultra-sensitive hydrogen gas sensors based on Pd-decorated tin dioxide nanostructures: Room temperature operating sensors
    • M.L. Jun, P. Seri, K. Ji-eun, K. Sol, L. Eunyoung, K. Sung-Jin, and L. Wooyoung Ultra-sensitive hydrogen gas sensors based on Pd-decorated tin dioxide nanostructures: room temperature operating sensors Journal of Hydrogen Energy 35 2010 12568 12573
    • (2010) Journal of Hydrogen Energy , vol.35 , pp. 12568-12573
    • Jun, M.L.1    Seri, P.2    Ji-Eun, K.3    Sol, K.4    Eunyoung, L.5    Sung-Jin, K.6    Wooyoung, L.7
  • 14
    • 67349270546 scopus 로고    scopus 로고
    • Development of microstructure In/Pd-doped SnO2 sensor for low-level CO detection
    • T. Zhang, L. Liua, Q. Qi, S. Li, and G. Lu Development of microstructure In/Pd-doped SnO2 sensor for low-level CO detection Sensors and Actuators B 139 2009 287 291
    • (2009) Sensors and Actuators B , vol.139 , pp. 287-291
    • Zhang, T.1    Liua, L.2    Qi, Q.3    Li, S.4    Lu, G.5
  • 15
    • 51649119757 scopus 로고    scopus 로고
    • Investigation of gas-sensitivity of sensor structures to hydrogen in a wide range of temperature, concentration and humidity of gas medium
    • V.V. Malyshev, and A.V. Pislyakov Investigation of gas-sensitivity of sensor structures to hydrogen in a wide range of temperature, concentration and humidity of gas medium Sensors and Actuators B 134 2008 913 921
    • (2008) Sensors and Actuators B , vol.134 , pp. 913-921
    • Malyshev, V.V.1    Pislyakov, A.V.2
  • 17
    • 84862959427 scopus 로고    scopus 로고
    • Research on the micro gas sensor test system based on constant gas-distribution method
    • Z. Bin, Y. Chenbo, T. Chunmin, and Z. Zili Research on the micro gas sensor test system based on constant gas-distribution method Chinese Journal of Scientific Instruments 32 2011 2681 2687
    • (2011) Chinese Journal of Scientific Instruments , vol.32 , pp. 2681-2687
    • Bin, Z.1    Chenbo, Y.2    Chunmin, T.3    Zili, Z.4
  • 20
    • 57549088014 scopus 로고    scopus 로고
    • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part I-testing facility and methodologies
    • L. Boon-Brett, J. Bousek, P. Castello, O. Salyk, F. Harskamp, L. Aldea, and F. Tinaut Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: part I-testing facility and methodologies International Journal of Hydrogen Energy 33 2008 7648 7657
    • (2008) International Journal of Hydrogen Energy , vol.33 , pp. 7648-7657
    • Boon-Brett, L.1    Bousek, J.2    Castello, P.3    Salyk, O.4    Harskamp, F.5    Aldea, L.6    Tinaut, F.7
  • 21
    • 77953912555 scopus 로고    scopus 로고
    • A comparison of test methods for the measurement of hydrogen sensor response and recovery times
    • L. Boon-Brett, G. Black, P. Moretto, and J. Bousek A comparison of test methods for the measurement of hydrogen sensor response and recovery times International Journal of Hydrogen Energy 35 2010 7652 7663
    • (2010) International Journal of Hydrogen Energy , vol.35 , pp. 7652-7663
    • Boon-Brett, L.1    Black, G.2    Moretto, P.3    Bousek, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.