메뉴 건너뛰기




Volumn 178, Issue , 2013, Pages 683-688

Rapid detection and quantification of bacteria using an integrated micro/nanofluidic device

Author keywords

Bacteria; Detection; Escherichia coli (E. coli); Micromixer; Preconcentration

Indexed keywords

BACTERIAL CELLS; ELECTRIC SHOCK; ESCHERICHIA COLI (E. COLI); FLUID STREAMS; FLUORESCENCE INTENSITIES; FLUORESCENT DYES; MICRO MIXERS; NANO CHANNELS; POLYDIMETHYLSILOXANE MEMBRANE; PRE-CONCENTRATION; PRE-CONCENTRATOR; RAPID DETECTION; TARGET POSITION;

EID: 84873691812     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.01.017     Document Type: Article
Times cited : (32)

References (34)
  • 1
    • 0033080856 scopus 로고    scopus 로고
    • Variable selection and multivariate methods for the identification of microorganisms by flow cytometry
    • DOI 10.1002/(SICI)1097-0320(19990201)35:2<162::AID-CYTO8>3.0.CO;2-U
    • H.M. Davey, A. Jones, A.D. Shaw, and D.B. Kell Variable selection and multivariate methods for the identification of microorganisms by flow cytometry Cytometry 35 1999 162 168 (Pubitemid 29053253)
    • (1999) Cytometry , vol.35 , Issue.2 , pp. 162-168
    • Davey, H.M.1    Jones, A.2    Shaw, A.D.3    Kell, D.B.4
  • 3
    • 0032745921 scopus 로고    scopus 로고
    • Biosensors for detection of pathogenic bacteria
    • DOI 10.1016/S0956-5663(99)00039-1, PII S0956566399000391
    • D. Ivnitski, I. Abdel-Hamid, P. Atanasov, and E. Wilkins Biosensors for detection of pathogenic bacteria Biosensors & Bioelectronics 14 1999 599 624 (Pubitemid 29528191)
    • (1999) Biosensors and Bioelectronics , vol.14 , Issue.7 , pp. 599-624
    • Ivnitski, D.1    Abdel-Hamid, I.2    Atanasov, P.3    Wilkins, E.4
  • 5
    • 18544374127 scopus 로고    scopus 로고
    • Real-time PCR detection of Listeria monocytogenes using an integrated microfluidics platform
    • DOI 10.1016/j.snb.2004.10.022, PII S0925400504007142
    • N.C. Cady, S. Stelick, M.V. Kunnavakkam, and C.A. Batt Real-time PCR detection of Listeria monocytogenes using an integrated microfluidics platform Sensors and Actuators B-Chemical 107 2005 332 341 (Pubitemid 40655089)
    • (2005) Sensors and Actuators, B: Chemical , vol.107 , Issue.SPEC. ISS.1 , pp. 332-341
    • Cady, N.C.1    Stelick, S.2    Kunnavakkam, M.V.3    Batt, C.A.4
  • 6
  • 7
    • 79955645600 scopus 로고    scopus 로고
    • Rapid detection of bacterial cell from whole blood: Integration of DNA sample preparation into single micro-PCR chip
    • K.Y. Hwang, S.Y. Jeong, Y.R. Kim, K. Namkoong, H.K. Lim, and W.S. Chung Rapid detection of bacterial cell from whole blood: integration of DNA sample preparation into single micro-PCR chip Sensors and Actuators B-Chemical 154 2011 46 51
    • (2011) Sensors and Actuators B-Chemical , vol.154 , pp. 46-51
    • Hwang, K.Y.1    Jeong, S.Y.2    Kim, Y.R.3    Namkoong, K.4    Lim, H.K.5    Chung, W.S.6
  • 9
    • 84455202278 scopus 로고    scopus 로고
    • Microfluidic electrochemical assay for rapid detection and quantification of Escherichia coli
    • M. Safavieh, M.U. Ahmed, M. Tolba, and M. Zourob Microfluidic electrochemical assay for rapid detection and quantification of Escherichia coli Biosensors & Bioelectronics 31 2012 523 528
    • (2012) Biosensors & Bioelectronics , vol.31 , pp. 523-528
    • Safavieh, M.1    Ahmed, M.U.2    Tolba, M.3    Zourob, M.4
  • 10
    • 34548639001 scopus 로고    scopus 로고
    • On-chip microfluidic biosensor for bacterial detection and identification
    • DOI 10.1016/j.snb.2007.03.043, PII S0925400507002456
    • D.A. Boehm, P.A. Gottlieb, and S.Z. Hua On-chip microfluidic biosensor for bacterial detection and identification Sensors and Actuators B-Chemical 126 2007 508 514 (Pubitemid 47405177)
    • (2007) Sensors and Actuators, B: Chemical , vol.126 , Issue.2 , pp. 508-514
    • Boehm, D.A.1    Gottlieb, P.A.2    Hua, S.Z.3
  • 11
    • 35748931751 scopus 로고    scopus 로고
    • A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food samples
    • DOI 10.1016/j.snb.2007.03.045, PII S0925400507003887
    • M. Varshney, Y.B. Li, B. Srinivasan, and S. Tung A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food samples Sensors and Actuators B-Chemical 128 2007 99 107 (Pubitemid 350051796)
    • (2007) Sensors and Actuators, B: Chemical , vol.128 , Issue.1 , pp. 99-107
    • Varshney, M.1    Li, Y.2    Srinivasan, B.3    Tung, S.4
  • 12
    • 80052326253 scopus 로고    scopus 로고
    • A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane
    • F. Tan, P.H.M. Leung, Z.B. Liu, Y. Zhang, L.D. Xiao, and W.W. Ye A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane Sensors and Actuators B-Chemical 159 2011 328 335
    • (2011) Sensors and Actuators B-Chemical , vol.159 , pp. 328-335
    • Tan, F.1    Leung, P.H.M.2    Liu, Z.B.3    Zhang, Y.4    Xiao, L.D.5    Ye, W.W.6
  • 14
    • 0035146289 scopus 로고    scopus 로고
    • Continuous concentration of bacteria in a microfluidic flow cell using electrokinetic techniques
    • C.R. Cabrera, and P. Yager Continuous concentration of bacteria in a microfluidic flow cell using electrokinetic techniques Electrophoresis 22 2001 355 362
    • (2001) Electrophoresis , vol.22 , pp. 355-362
    • Cabrera, C.R.1    Yager, P.2
  • 15
    • 70449843673 scopus 로고    scopus 로고
    • Bacteria concentration using a membrane type insulator-based dielectrophoresis in a plastic chip
    • Y.K. Cho, S. Kim, K. Lee, C. Park, J.G. Lee, and C. Ko Bacteria concentration using a membrane type insulator-based dielectrophoresis in a plastic chip Electrophoresis 30 2009 3153 3159
    • (2009) Electrophoresis , vol.30 , pp. 3153-3159
    • Cho, Y.K.1    Kim, S.2    Lee, K.3    Park, C.4    Lee, J.G.5    Ko, C.6
  • 16
    • 3042856485 scopus 로고    scopus 로고
    • Insulator-based dielectrophoresis for the selective concentration and separation of live bacteria in water
    • B.H. Lapizco-Encinas, B.A. Simmons, E.B. Cummings, and Y. Fintschenko Insulator-based dielectrophoresis for the selective concentration and separation of live bacteria in water Electrophoresis 25 2004 1695 1704 (Pubitemid 38885835)
    • (2004) Electrophoresis , vol.25 , Issue.10-11 , pp. 1695-1704
    • Lapizco-Encinas, B.H.1    Simmons, B.A.2    Cummings, E.B.3    Fintschenko, Y.4
  • 17
    • 33645808482 scopus 로고    scopus 로고
    • Bacteria capture, concentration and detection by alternating current dielectrophoresis and self-assembly of dispersed single-wall carbon nanotubes
    • R.H. Zhou, P. Wang, and H.C. Chang Bacteria capture, concentration and detection by alternating current dielectrophoresis and self-assembly of dispersed single-wall carbon nanotubes Electrophoresis 27 2006 1376 1385
    • (2006) Electrophoresis , vol.27 , pp. 1376-1385
    • Zhou, R.H.1    Wang, P.2    Chang, H.C.3
  • 20
    • 38849088088 scopus 로고    scopus 로고
    • Integrated nanopore/microchannel devices for ac electrokinetic trapping of particles
    • DOI 10.1021/ac701759f
    • M.L. Kovarik, and S.C. Jacobson Integrated nanopore/microchannel devices for ac electrokinetic trapping of particles Analytical Chemistry 80 2008 657 664 (Pubitemid 351206853)
    • (2008) Analytical Chemistry , vol.80 , Issue.3 , pp. 657-664
    • Kovarik, M.L.1    Jacobson, S.C.2
  • 21
    • 44449116732 scopus 로고    scopus 로고
    • A microfluidic device for physical trapping and electrical lysis of bacterial cells
    • N. Bao, and C. Lu A microfluidic device for physical trapping and electrical lysis of bacterial cells Applied Physics Letters 92 2008 214103
    • (2008) Applied Physics Letters , vol.92 , pp. 214103
    • Bao, N.1    Lu, C.2
  • 23
    • 79955897566 scopus 로고    scopus 로고
    • Integrated micro/nano-fluidic system for mixing and preconcentration of dissolved proteins
    • K. Anwar, T. Han, S. Yu, and S.M. Kim Integrated micro/nano-fluidic system for mixing and preconcentration of dissolved proteins Microchimica Acta 173 2011 331 335
    • (2011) Microchimica Acta , vol.173 , pp. 331-335
    • Anwar, K.1    Han, T.2    Yu, S.3    Kim, S.M.4
  • 24
    • 0035580730 scopus 로고    scopus 로고
    • Fabrication of a configurable, single-use microfluidic device
    • DOI 10.1021/ac010631r
    • J.C. McDonald, S.J. Metallo, and G.M. Whitesides Fabrication of a configurable, single-use microfluidic device Analytical Chemistry 73 2001 5645 5650 (Pubitemid 33126719)
    • (2001) Analytical Chemistry , vol.73 , Issue.23 , pp. 5645-5650
    • McDonald, J.C.1    Metallo, S.J.2    Whitesides, G.M.3
  • 25
    • 52649103141 scopus 로고    scopus 로고
    • A simple, disposable microfluidic device for rapid protein concentration and purification via direct-printing
    • H. Yu, Y. Lu, Y.G. Zhou, F.B. Wang, F.Y. He, and X.H. Xia A simple, disposable microfluidic device for rapid protein concentration and purification via direct-printing Lab on a Chip 8 2008 1496 1501
    • (2008) Lab on A Chip , vol.8 , pp. 1496-1501
    • Yu, H.1    Lu, Y.2    Zhou, Y.G.3    Wang, F.B.4    He, F.Y.5    Xia, X.H.6
  • 26
    • 82755189890 scopus 로고    scopus 로고
    • Interconnected ordered nanoporous networks of colloidal crystals integrated on a microfluidic chip for highly efficient protein concentration
    • Y.L. Hu, C. Wang, Z.Q. Wu, J.J. Xu, H.Y. Chen, and X.H. Xia Interconnected ordered nanoporous networks of colloidal crystals integrated on a microfluidic chip for highly efficient protein concentration Electrophoresis 32 2011 3424 3430
    • (2011) Electrophoresis , vol.32 , pp. 3424-3430
    • Hu, Y.L.1    Wang, C.2    Wu, Z.Q.3    Xu, J.J.4    Chen, H.Y.5    Xia, X.H.6
  • 28
    • 34548588442 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane)-based protein preconcentration using a nanogap generated by junction gap breakdown
    • DOI 10.1021/ac071162h
    • J.H. Lee, S. Chung, S.J. Kim, and J.Y. Han Poly(dimethylsiloxane)-based protein preconcentration using a nanogap generated by junction gap breakdown Analytical Chemistry 79 2007 6868 6873 (Pubitemid 47395080)
    • (2007) Analytical Chemistry , vol.79 , Issue.17 , pp. 6868-6873
    • Jeong, H.L.1    Chung, S.2    Sung, J.K.3    Han, J.4
  • 29
    • 84863216194 scopus 로고    scopus 로고
    • Active micromixer using electrokinetic effects in the micro/nanochannel junction
    • S. Yu, T.-J. Jeon, and S.M. Kim Active micromixer using electrokinetic effects in the micro/nanochannel junction Chemical Engineering Journal 197 2012 289 294
    • (2012) Chemical Engineering Journal , vol.197 , pp. 289-294
    • Yu, S.1    Jeon, T.-J.2    Kim, S.M.3
  • 30
    • 0032587252 scopus 로고    scopus 로고
    • LIVE/DEAD(®) BacLight(TM): Application of a new rapid staining method for direct enumeration of viable and total bacteria in drinking water
    • DOI 10.1016/S0167-7012(99)00048-2, PII S0167701299000482
    • L. Boulos, M. Prevost, B. Barbeau, J. Coallier, and R. Desjardins LIVE/DEAD (R) BacLight (TM): application of a new rapid staining method for direct enumeration of viable and total bacteria in drinking water Journal of Microbiological Methods 37 1999 77 86 (Pubitemid 29248770)
    • (1999) Journal of Microbiological Methods , vol.37 , Issue.1 , pp. 77-86
    • Boulos, L.1    Prevost, M.2    Barbeau, B.3    Coallier, J.4    Desjardins, R.5
  • 31
    • 33746260423 scopus 로고    scopus 로고
    • Electrokinetic protein preconcentration using a simple glass/ poly(dimethylsiloxane) microfluidic chip
    • DOI 10.1021/ac060031y
    • S.M. Kim, M.A. Burns, and E.F. Hasselbrink Electrokinetic protein preconcentration using a simple glass/poly(dimethylsiloxane) microfluidic chip Analytical Chemistry 78 2006 4779 4785 (Pubitemid 44100610)
    • (2006) Analytical Chemistry , vol.78 , Issue.14 , pp. 4779-4785
    • Kim, S.M.1    Burns, M.A.2    Hasselbrink, E.F.3
  • 32
    • 34547465510 scopus 로고    scopus 로고
    • Concentration polarization and nonlinear electrokinetic flow near a nanofluidic channel
    • S.J. Kim, Y.C. Wang, J.H. Lee, H. Jang, and J. Han Concentration polarization and nonlinear electrokinetic flow near a nanofluidic channel Physical Review Letters 99 2007 044501
    • (2007) Physical Review Letters , vol.99 , pp. 044501
    • Kim, S.J.1    Wang, Y.C.2    Lee, J.H.3    Jang, H.4    Han, J.5
  • 33
    • 67650095727 scopus 로고    scopus 로고
    • Amplified electrokinetic response by concentration polarization near nanofluidic channel
    • S.J. Kim, L.D. Li, and J. Han Amplified electrokinetic response by concentration polarization near nanofluidic channel Langmuir 25 2009 7759 7765
    • (2009) Langmuir , vol.25 , pp. 7759-7765
    • Kim, S.J.1    Li, L.D.2    Han, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.