메뉴 건너뛰기




Volumn 155, Issue 1, 2011, Pages 422-429

Low-cost polymer microfluidic device for on-chip extraction of bacterial DNA

Author keywords

Bacterial DNA; Organosilane; PCR; Photocatalyst; Polymer based microchip

Indexed keywords

BACTERIAL CELLS; BACTERIAL DNA; DEVICE FABRICATIONS; FABRICATION PROCESS; HIGH SURFACE-TO-VOLUME RATIO; HOT-EMBOSSING; IN-SITU; LATERAL SURFACE; MICRO-PILLARS; MOLECULAR DIAGNOSTICS; NI MOLD; ON CHIPS; OPEN MICROCHANNEL; ORGANOSILANE COATINGS; ORGANOSILANE COMPOUNDS; ORGANOSILANES; PCR; PDMS SUBSTRATE; PHOTOCATALYTIC OXIDATIONS; POLYMER MICROFLUIDICS; POLYMER-BASED MICROCHIPS; PROCESS INTEGRATION; ROOM TEMPERATURE; TIO; WAFER LEVEL;

EID: 79956341073     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.12.026     Document Type: Article
Times cited : (19)

References (36)
  • 3
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems. A novel concept for chemical sensing
    • A. Manz, N. Graber, and H.M. Widmer Miniaturized total chemical analysis systems: a novel concept for chemical sensing Sens. Actuator B 1 1990 244 248 (Pubitemid 20699475)
    • (1990) Sensors and Actuators, B: Chemical , vol.B1 , Issue.1-6 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 4
    • 51549087361 scopus 로고    scopus 로고
    • Purification of nucleic acids in microfluidic devices
    • J. Wen, L.A. Lgendre, J.M. Benvenue, and J.P. Landers Purification of nucleic acids in microfluidic devices Anal. Chem. 80 2008 6472 6479
    • (2008) Anal. Chem. , vol.80 , pp. 6472-6479
    • Wen, J.1    Lgendre, L.A.2    Benvenue, J.M.3    Landers, J.P.4
  • 5
    • 0343938892 scopus 로고    scopus 로고
    • Identification and characterization of immunoglobulin G in blood as a major inhibitor of diagnostic PCR
    • W.A. Al-Soud, L.J. Jonsson, and P. Radstrom Identification and characterization of immunoglobulin G in blood as a major inhibitor of diagnostic PCR J. Clin. Microbiol. 38 2000 345 350 (Pubitemid 30043314)
    • (2000) Journal of Clinical Microbiology , vol.38 , Issue.1 , pp. 345-350
    • Al-Soud, W.A.1    Jonsson, L.J.2    Radstrom, P.3
  • 6
    • 0035126283 scopus 로고    scopus 로고
    • Purification and characterization of PCR-inhibitory components in blood cells
    • DOI 10.1128/JCM.39.2.485-493.2001
    • W.A. Al-Soud, and P. Radstrom Purification and characterization of PCR-inhibitory components in blood cells J. Clin. Microbiol. 39 2001 485 493 (Pubitemid 32150805)
    • (2001) Journal of Clinical Microbiology , vol.39 , Issue.2 , pp. 485-493
    • Al-Soud, W.A.1    Radstrom, P.2
  • 8
    • 0037060122 scopus 로고    scopus 로고
    • Sample pretreatment on microfabricated devices
    • DOI 10.1016/S0039-9140(01)00593-8, PII S0039914001005938
    • J. Lichtenberg, N.F. De Rooij, and E. Verpoorte Sample pretreatment on microfabricated devices Talanta 56 2002 233 266 (Pubitemid 34149703)
    • (2002) Talanta , vol.56 , Issue.2 , pp. 233-266
    • Lichtenberg, J.1    Se Rooij, N.F.2    Verpoorte, E.3
  • 9
    • 70349331519 scopus 로고    scopus 로고
    • Nucleic acid extraction techniques and application to the microchip
    • C.W. Price, D.C. Leslie, and J.P. Landers Nucleic acid extraction techniques and application to the microchip Lab Chip 9 2009 2484 2494
    • (2009) Lab Chip , vol.9 , pp. 2484-2494
    • Price, C.W.1    Leslie, D.C.2    Landers, J.P.3
  • 10
    • 0030748867 scopus 로고    scopus 로고
    • Inhibition and facilitation of nucleic acid amplification
    • I.G. Wilson Inhibition and facilitation of nucleic acid amplification Appl. Environ. Microbiol. 63 1997 3741 3751 (Pubitemid 27411322)
    • (1997) Applied and Environmental Microbiology , vol.63 , Issue.10 , pp. 3741-3751
    • Wilson, I.G.1
  • 11
    • 0343550309 scopus 로고    scopus 로고
    • Polymer microfabrication methods for microfluidic analytical applications
    • H. Becker, and C. Gartner Polymer microfabrication methods for microfluidic analytical applications Electrophoresis 21 2000 12 26 (Pubitemid 30032693)
    • (2000) Electrophoresis , vol.21 , Issue.1 , pp. 12-26
    • Becker, H.1    Gartner, C.2
  • 12
    • 37549023085 scopus 로고    scopus 로고
    • Polymer microfabrication technologies for microfluidic systems
    • H. Becker, and C. Gartner Polymer microfabrication technologies for microfluidic systems Anal. Bioanal. Chem. 390 2008 89 111
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 89-111
    • Becker, H.1    Gartner, C.2
  • 13
    • 20144388594 scopus 로고    scopus 로고
    • High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding
    • DOI 10.1021/ac0485031
    • F. Dang, O. Tabata, M. Kurokawa, A.A. Ewis, L. Zhang, Y. Yamaoka, S. Shinohara, Y. Shinohara, M. Ishikawa, and Y. Baba High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding Anal. Chem. 77 2005 2140 2146 (Pubitemid 40463831)
    • (2005) Analytical Chemistry , vol.77 , Issue.7 , pp. 2140-2146
    • Dang, F.1    Tabata, O.2    Kurokawa, M.3    Ewis, A.A.4    Zhang, L.5    Yamaoka, Y.6    Shinohara, S.7    Shinohara, Y.8    Ishikawa, M.9    Baba, Y.10
  • 14
    • 58249090780 scopus 로고    scopus 로고
    • Bonding of thermoplastic polymer microfluidics
    • C.-W. Tsao, and D.L. De Voe Bonding of thermoplastic polymer microfluidics Microfluid Nanofluid 6 2009 1 16
    • (2009) Microfluid Nanofluid , vol.6 , pp. 1-16
    • Tsao, C.-W.1    De Voe, D.L.2
  • 16
    • 32444435013 scopus 로고    scopus 로고
    • Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics
    • DOI 10.1021/ac051449j
    • A. Bhattacharyya, and C.M. Klapperich Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics Anal. Chem. 78 2006 788 792 (Pubitemid 43228586)
    • (2006) Analytical Chemistry , vol.78 , Issue.3 , pp. 788-792
    • Bhattacharyya, A.1    Klapperich, C.M.2
  • 19
    • 42949121091 scopus 로고    scopus 로고
    • 96-Well polycarbonate-based microfluidic titer plate for high-throughput purification of DNA and RNA
    • DOI 10.1021/ac8002352
    • M.A. Witek, M.L. Hupert, D. Park, K. Fears, M.C. Murphy, and S.A. Soper 96-well polycarbonate-based microfluidic titer plate for high-throughput purification of DNA and RNA Anal. Chem. 80 2008 3483 3491 (Pubitemid 351620738)
    • (2008) Analytical Chemistry , vol.80 , Issue.9 , pp. 3483-3491
    • Witek, M.A.1    Hupert, M.L.2    Park, D.S.-W.3    Fears, K.4    Murphy, M.C.5    Soper, S.A.6
  • 20
    • 0037663231 scopus 로고    scopus 로고
    • Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments
    • DOI 10.1021/ac030031n
    • Y. Xu, B. Vaidya, A.B. Patel, S.M. Ford, R.L. McCarley, and S.A. Soper Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments Anal. Chem. 75 2003 2975 2984 (Pubitemid 36830423)
    • (2003) Analytical Chemistry , vol.75 , Issue.13 , pp. 2975-2984
    • Xu, Y.1    Vaidya, B.2    Patel, A.B.3    Ford, S.M.4    McCarley, R.L.5    Soper, S.A.6
  • 21
    • 33750205143 scopus 로고    scopus 로고
    • Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system
    • DOI 10.1021/ac060391l
    • W. Cao, C.J. Easley, J.P. Ferrance, and J.P. Landers Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system Anal. Chem. 78 2006 7222 7228 (Pubitemid 44607567)
    • (2006) Analytical Chemistry , vol.78 , Issue.20 , pp. 7222-7228
    • Cao, W.1    Easley, C.J.2    Ferrance, J.P.3    Landers, J.P.4
  • 22
    • 12344264814 scopus 로고    scopus 로고
    • Fabrication of amino silane-coated microchip for DNA extraction from whole blood
    • DOI 10.1016/j.jbiotec.2004.08.018, PII S0168165604005188
    • T. Nakagawa, T. Tanaka, D. Niwa, T. Osaka, H. Takeyama, and T. Matsunaga Fabrication of aminosilane-coated microchip for DNA extraction from whole blood J. Biotechnol. 116 2005 105 111 (Pubitemid 40128561)
    • (2005) Journal of Biotechnology , vol.116 , Issue.2 , pp. 105-111
    • Nakagawa, T.1    Tanaka, T.2    Niwa, D.3    Osaka, T.4    Takeyama, H.5    Matsunaga, T.6
  • 23
    • 52649108805 scopus 로고    scopus 로고
    • Quantitative and qualitative analysis of a microfluidic DNA extraction system using a nanoporous AlO(x) membrane
    • J. Kim, and B.K. Gale Quantitative and qualitative analysis of a microfluidic DNA extraction system using a nanoporous AlO(x) membrane Lab Chip 8 2008 1516 1523
    • (2008) Lab Chip , vol.8 , pp. 1516-1523
    • Kim, J.1    Gale, B.K.2
  • 24
    • 54349109307 scopus 로고    scopus 로고
    • Bacterial DNA sample preparation from whole blood using surface-modified Si pillar arrays
    • K.Y. Hwang, H.K. Lim, S.Y. Jung, K. Namkoong, J.H. Kim, N. Huh, C. Ko, and J.C. Park Bacterial DNA sample preparation from whole blood using surface-modified Si pillar arrays Anal. Chem. 80 2008 7786 7791
    • (2008) Anal. Chem. , vol.80 , pp. 7786-7791
    • Hwang, K.Y.1    Lim, H.K.2    Jung, S.Y.3    Namkoong, K.4    Kim, J.H.5    Huh, N.6    Ko, C.7    Park, J.C.8
  • 25
    • 79955645600 scopus 로고    scopus 로고
    • Rapid detection of bacterial cell from whole blood: Integration of DNA sample preparation into single micro-PCR chip
    • doi:10.1016/j.snb.2009.11.005,inpress
    • K.Y. Hwang, S.Y. Jeong, Y.R. Kim, K. Namkoong, H.K. Lim, W.S. Chung, J.H. Kim, N. Huh, Rapid detection of bacterial cell from whole blood: integration of DNA sample preparation into single micro-PCR chip, Sens. Actuator B, doi:10.1016/j.snb.2009.11.005, in press.
    • Sens. Actuator B
    • Hwang, K.Y.1    Jeong, S.Y.2    Kim, Y.R.3    Namkoong, K.4    Lim, H.K.5    Chung, W.S.6    Kim, J.H.7    Huh, N.8
  • 28
    • 34247504603 scopus 로고    scopus 로고
    • Lab-on-chip technologies: Making a microfluidic network and coupling it into a complete microsystem - A review
    • P. Abgrall, and A.-M. Gue Lab-on-chip technologies: making a microfluidic network and coupling it into a complete microsystem - a review J. Micromech. Microeng. 17 2007 R15 R49
    • (2007) J. Micromech. Microeng. , vol.17
    • Abgrall, P.1    Gue, A.-M.2
  • 29
    • 42549125999 scopus 로고    scopus 로고
    • Determining the optimal PDMS-PDMS bonding technique for microfluidic devices
    • M.A. Eddings, M.A. Johnson, and B.K. Gale Determining the optimal PDMS-PDMS bonding technique for microfluidic devices J. Micromech. Microeng. 18 2008 0670011 0670014
    • (2008) J. Micromech. Microeng. , vol.18 , pp. 0670011-0670014
    • Eddings, M.A.1    Johnson, M.A.2    Gale, B.K.3
  • 30
    • 22444435567 scopus 로고    scopus 로고
    • Studies on surface wettability of poly(dimethyl) siloxane (PDMS) and glass under oxygen-plasma treatment and correlation with bond strength
    • DOI 10.1109/JMEMS.2005.844746
    • S. Bhattacharya, A. Datta, J.M. Berg, and S. Gangopadhyay Studies on surface wettability of poly(dimethyl)siloxane (PDMS) and glass under oxygen-plasma treatment and correlation with bond strength J. Microelectromech. Syst. 14 2005 590 597 (Pubitemid 41005078)
    • (2005) Journal of Microelectromechanical Systems , vol.14 , Issue.3 , pp. 590-597
    • Bhattacharya, S.1    Datta, A.2    Berg, J.M.3    Gangopadhyay, S.4
  • 31
    • 33751084908 scopus 로고    scopus 로고
    • An ultrasonic welding based process for building up a new class of inert fluidic microsensors and -actuators from polymers
    • DOI 10.1016/j.sna.2006.04.040, PII S0924424706003037
    • R. Truckenmuller, R. Ahrens, Y. Cheng, G. Fischer, and V. Saile An ultrasonic welding based process for building up a new class of inert fluidic microsensors and -actuators from polymers Sens. Actuator A 132 2006 385 392 (Pubitemid 44764969)
    • (2006) Sensors and Actuators, A: Physical , vol.132 , Issue.1 SPEC. ISS. , pp. 385-392
    • Truckenmuller, R.1    Ahrens, R.2    Cheng, Y.3    Fischer, G.4    Saile, V.5
  • 32
    • 4644291198 scopus 로고    scopus 로고
    • Bonding of polymer microstructures by UV irradiation and subsequent welding at low temperatures
    • R. Truckenmuller, P. Henzi, D. Herrmann, V. Saile, and W.K. Schomburg Bonding of polymer microstructures by UV irradiation and subsequent welding at low temperatures Microsyst. Technol. 10 2004 372 374
    • (2004) Microsyst. Technol. , vol.10 , pp. 372-374
    • Truckenmuller, R.1    Henzi, P.2    Herrmann, D.3    Saile, V.4    Schomburg, W.K.5
  • 34
    • 1542366413 scopus 로고    scopus 로고
    • Mechanisms and resolution of photocatalytic lithography
    • W. Kubo, T. Tatsuma, A. Fujishima, and H. Kobayashi Mechanisms and resolution of photocatalytic lithography J. Phys. Chem. B 108 2004 3005 3009
    • (2004) J. Phys. Chem. B , vol.108 , pp. 3005-3009
    • Kubo, W.1    Tatsuma, T.2    Fujishima, A.3    Kobayashi, H.4
  • 36
    • 0002436838 scopus 로고    scopus 로고
    • Quantitative PCR by continuous fluorescence monitoring of a double strand DNA specific binding dye
    • R. Rasmussen, T. Morrison, M. Herrmann, and C. Wittwer Quantitative PCR by continuous fluorescence monitoring of a double strand DNA specific binding dye Biochemica 2 1998 8 11
    • (1998) Biochemica , vol.2 , pp. 8-11
    • Rasmussen, R.1    Morrison, T.2    Herrmann, M.3    Wittwer, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.