메뉴 건너뛰기




Volumn 58, Issue 4, 2013, Pages 749-770

4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung

Author keywords

[No Author keywords available]

Indexed keywords

B-SPLINE TRANSFORMATIONS; CT DATA; CT IMAGE; DOSE ESCALATION; DOSE-VOLUME HISTOGRAMS; HEALTHY TISSUES; LUNG CANCER; NON SMALL CELL LUNG CANCER; OPTIMIZATION PROCESS; ORGAN AT RISKS; PATIENT BREATHING; PLAN QUALITY; RESPIRATORY CYCLE; STEREOTACTIC BODY RADIATION THERAPY; TARGET MOTIONS; TISSUE MOTION; TOTAL DOSE; TREATMENT PLANS; TREATMENT TIME; VOLUMETRIC MODULATED ARC THERAPY;

EID: 84873679711     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/58/4/749     Document Type: Article
Times cited : (41)

References (75)
  • 1
    • 33745071905 scopus 로고    scopus 로고
    • A novel four-dimensional radiotherapy method for lung cancer: Imaging, treatment planning and delivery
    • 10.1088/0031-9155/51/12/017 0031-9155
    • Alasti H, Cho Y B, Vandermeer A D, Abbas A, Norrlinger B, Shubbar S and Bezjak A 2006 A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery Phys. Med. Biol. 51 3251-67
    • (2006) Phys. Med. Biol. , vol.51 , Issue.12 , pp. 3251-3267
    • Alasti, H.1    Cho, Y.B.2    Vandermeer, A.D.3    Abbas, A.4    Norrlinger, B.5    Shubbar, S.6    Bezjak, A.7
  • 2
    • 80053579162 scopus 로고    scopus 로고
    • Isotoxic dose escalation in the treatment of lung cancer by means of heterogeneous dose distributions in the presence of respiratory motion
    • 10.1016/j.ijrobp.2010.12.001 0360-3016
    • Baker M, Nielsen M, Hansen O, Jahn J W, Korreman S and Brink C 2011 Isotoxic dose escalation in the treatment of lung cancer by means of heterogeneous dose distributions in the presence of respiratory motion Int. J. Radiat. Oncol. Biol. Phys. 81 849-55
    • (2011) Int. J. Radiat. Oncol. Biol. Phys. , vol.81 , Issue.3 , pp. 849-855
    • Baker, M.1    Nielsen, M.2    Hansen, O.3    Jahn, J.W.4    Korreman, S.5    Brink, C.6
  • 3
    • 78149492263 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy: The report of AAPM Task Group 101
    • 10.1118/1.3438081 0094-2405
    • Benedict S H et al 2010 Stereotactic body radiation therapy: the report of AAPM Task Group 101 Med. Phys. 37 4078-101
    • (2010) Med. Phys. , vol.37 , Issue.8 , pp. 4078-4101
    • Benedict, S.H.1
  • 4
    • 0033048690 scopus 로고    scopus 로고
    • Optimized planning using physical objectives and constraints
    • 10.1016/S1053-4296(99)80052-6 1053-4296
    • Bortfeld T 1999 Optimized planning using physical objectives and constraints Semin. Radiat. Oncol. 9 20-34
    • (1999) Semin. Radiat. Oncol. , vol.9 , Issue.1 , pp. 20-34
    • Bortfeld, T.1
  • 5
    • 84455181494 scopus 로고    scopus 로고
    • Optimising stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy-A planning study
    • 10.1016/j.clon.2011.02.003 0936-6555
    • Brock J, Bedford J, Partridge M, McDonald F, Ashley S, McNair H A and Brada M 2012 Optimising stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy-A planning study Clin. Oncol. 24 68-75
    • (2012) Clin. Oncol. , vol.24 , Issue.1 , pp. 68-75
    • Brock, J.1    Bedford, J.2    Partridge, M.3    McDonald, F.4    Ashley, S.5    McNair, H.A.6    Brada, M.7
  • 6
    • 79960363882 scopus 로고    scopus 로고
    • MRI-guided tumor tracking in lung cancer radiotherapy
    • 10.1088/0031-9155/56/13/003 0031-9155
    • Cervino L I, Du J and Jiang S B 2011 MRI-guided tumor tracking in lung cancer radiotherapy Phys. Med. Biol. 56 3773-85
    • (2011) Phys. Med. Biol. , vol.56 , Issue.13 , pp. 3773-3785
    • Cervino, L.I.1    Du, J.2    Jiang, S.B.3
  • 7
    • 79959537534 scopus 로고    scopus 로고
    • Investigation of a novel algorithm for true 4D-VMAT planning with comparison to tracked, gated and static delivery
    • 10.1118/1.3578608 0094-2405
    • Chin E and Otto K 2011 Investigation of a novel algorithm for true 4D-VMAT planning with comparison to tracked, gated and static delivery Med. Phys. 38 2698-707
    • (2011) Med. Phys. , vol.38 , Issue.5 , pp. 2698-2707
    • Chin, E.1    Otto, K.2
  • 8
    • 45749084084 scopus 로고    scopus 로고
    • A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring
    • 10.1088/0031-9155/53/11/006 0031-9155
    • Cho B, Suh Y, Dieterich S and Keall P J 2008 A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring Phys. Med. Biol. 53 2837-55
    • (2008) Phys. Med. Biol. , vol.53 , Issue.11 , pp. 2837-2855
    • Cho, B.1    Suh, Y.2    Dieterich, S.3    Keall, P.J.4
  • 9
    • 33744820555 scopus 로고    scopus 로고
    • Linac-integrated 4D cone beam CT: First experimental results
    • 10.1088/0031-9155/51/11/017 0031-9155
    • Dietrich L, Jetter S, Tuecking T, Nill S and Oelfke U 2006 Linac-integrated 4D cone beam CT: first experimental results Phys. Med. Biol. 51 2939-52
    • (2006) Phys. Med. Biol. , vol.51 , Issue.11 , pp. 2939-2952
    • Dietrich, L.1    Jetter, S.2    Tuecking, T.3    Nill, S.4    Oelfke, U.5
  • 10
    • 78149478818 scopus 로고    scopus 로고
    • Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis
    • 10.1118/1.3455276 0094-2405
    • Eom J, Xu X G, De S and Shi C 2010 Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis Med. Phys. 37 4389-400
    • (2010) Med. Phys. , vol.37 , Issue.8 , pp. 4389-4400
    • Eom, J.1    Xu, X.G.2    De, S.3    Shi, C.4
  • 13
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning
    • 10.1118/1.1531177 0094-2405
    • Ford E C, Mageras G S, Yorke E and Ling C C 2003 Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning Med. Phys. 30 88-97
    • (2003) Med. Phys. , vol.30 , Issue.1 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3    Ling, C.C.4
  • 14
    • 25644456180 scopus 로고    scopus 로고
    • The application of the sinusoidal model to lung cancer patient respiratory motion
    • 10.1118/1.2001220 0094-2405
    • George R, Vedam S S, Chung T D, Ramakrishnan V and Keall P J 2005 The application of the sinusoidal model to lung cancer patient respiratory motion Med. Phys. 32 2850-61
    • (2005) Med. Phys. , vol.32 , Issue.9 , pp. 2850-2861
    • George, R.1    Vedam, S.S.2    Chung, T.D.3    Ramakrishnan, V.4    Keall, P.J.5
  • 15
    • 79956068325 scopus 로고    scopus 로고
    • A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation
    • 10.1088/0031-9155/56/11/010 0031-9155
    • Gu X, Jelen U, Li J, Jia X and Jiang S B 2011 A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation Phys. Med. Biol. 56 3337-50
    • (2011) Phys. Med. Biol. , vol.56 , Issue.11 , pp. 3337-3350
    • Gu, X.1    Jelen, U.2    Li, J.3    Jia, X.4    Jiang, S.B.5
  • 16
    • 79952450163 scopus 로고    scopus 로고
    • A novel respiratory motion compensation strategy combining gated beam delivery and mean target position concept - A compromise between small safety margins and long duty cycles
    • 10.1016/j.radonc.2011.01.008 0167-8140
    • Guckenberger M, Kavanagh A, Webb S and Brada M 2011 A novel respiratory motion compensation strategy combining gated beam delivery and mean target position concept - a compromise between small safety margins and long duty cycles Radiother. Oncol. 98 317-22
    • (2011) Radiother. Oncol. , vol.98 , Issue.3 , pp. 317-322
    • Guckenberger, M.1    Kavanagh, A.2    Webb, S.3    Brada, M.4
  • 17
    • 65749109343 scopus 로고    scopus 로고
    • Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy
    • 10.1016/j.radonc.2008.08.010 0167-8140
    • Guckenberger M, Krieger T, Richter A, Baier K, Wilbert J, Sweeney R A and Flentje M 2009 Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy Radiother. Oncol. 91 288-95
    • (2009) Radiother. Oncol. , vol.91 , Issue.3 , pp. 288-295
    • Guckenberger, M.1    Krieger, T.2    Richter, A.3    Baier, K.4    Wilbert, J.5    Sweeney, R.A.6    Flentje, M.7
  • 18
    • 77952410548 scopus 로고    scopus 로고
    • Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method
    • 10.1118/1.3319498 0094-2405
    • Gui M, Feng Y, Yi B, Dhople A A and Yu C 2010 Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method Med. Phys. 37 1966-75
    • (2010) Med. Phys. , vol.37 , Issue.5 , pp. 1966-1975
    • Gui, M.1    Feng, Y.2    Yi, B.3    Dhople, A.A.4    Yu, C.5
  • 19
    • 79959547653 scopus 로고    scopus 로고
    • Real time 4D IMRT treatment planning based on a dynamic virtual patient model: Proof of concept
    • 10.1118/1.3578927 0094-2405
    • Guo B, Xu X G and Shi C 2011 Real time 4D IMRT treatment planning based on a dynamic virtual patient model: proof of concept Med. Phys. 38 2639-50
    • (2011) Med. Phys. , vol.38 , Issue.5 , pp. 2639-2650
    • Guo, B.1    Xu, X.G.2    Shi, C.3
  • 20
    • 80054058561 scopus 로고    scopus 로고
    • Volumetric-modulated arc therapy for stereotactic body radiotherapy of lung tumors: A comparison with intensity-modulated radiotherapy techniques
    • 10.1016/j.ijrobp.2010.09.014 0360-3016
    • Holt A, van Vliet-Vroegindeweij C, Mans A, Belderbos J S and Damen E M F 2011 Volumetric-modulated arc therapy for stereotactic body radiotherapy of lung tumors: a comparison with intensity-modulated radiotherapy techniques Int. J. Radiat. Oncol. Biol. Phys. 81 1560-5
    • (2011) Int. J. Radiat. Oncol. Biol. Phys. , vol.81 , Issue.5 , pp. 1560-1565
    • Holt, A.1    Van Vliet-Vroegindeweij, C.2    Mans, A.3    Belderbos, J.S.4    Damen, E.M.F.5
  • 21
    • 80155134727 scopus 로고    scopus 로고
    • GPU-based fast Monte Carlo simulation for radiotherapy dose calculation
    • 10.1088/0031-9155/56/22/002 0031-9155
    • Jia X, Gu X, Graves Y J, Folkerts M and Jiang S B 2011 GPU-based fast Monte Carlo simulation for radiotherapy dose calculation Phys. Med. Biol. 56 7017-31
    • (2011) Phys. Med. Biol. , vol.56 , Issue.22 , pp. 7017-7031
    • Jia, X.1    Gu, X.2    Graves, Y.J.3    Folkerts, M.4    Jiang, S.B.5
  • 22
    • 4444324690 scopus 로고    scopus 로고
    • Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion
    • 10.1088/0031-9155/49/16/011 0031-9155
    • Keall P J, Siebers J V, Joshi S and Mohan R 2004a Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion Phys. Med. Biol. 49 3639-48
    • (2004) Phys. Med. Biol. , vol.49 , Issue.16 , pp. 3639-3648
    • Keall, P.J.1    Siebers, J.V.2    Joshi, S.3    Mohan, R.4
  • 24
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • 10.1118/1.2349696 0094-2405
    • Keall P et al 2006 The management of respiratory motion in radiation oncology report of AAPM Task Group 76 Med. Phys. 33 3874-900
    • (2006) Med. Phys. , vol.33 , Issue.10 , pp. 3874-3900
    • Keall, P.1
  • 25
    • 59249104593 scopus 로고    scopus 로고
    • Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase
    • 10.1118/1.3049595 0094-2405
    • Langner U W and Keall P J 2009 Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase Med. Phys. 36 386-93
    • (2009) Med. Phys. , vol.36 , Issue.2 , pp. 386-393
    • Langner, U.W.1    Keall, P.J.2
  • 26
    • 70249100336 scopus 로고    scopus 로고
    • Conceptual formulation on four-dimensional inverse planning for intensity modulated radiation therapy
    • 0031-9155 N01
    • Lee L, Ma Y, Ye Y and Xing L 2009 Conceptual formulation on four-dimensional inverse planning for intensity modulated radiation therapy Phys. Med. Biol. 54 N255-66
    • (2009) Phys. Med. Biol. , vol.54 , Issue.13
    • Lee, L.1    Ma, Y.2    Ye, Y.3    Xing, L.4
  • 27
    • 33749387058 scopus 로고    scopus 로고
    • Four-dimensional cone-beam computed tomography using an on-board imager
    • 10.1118/1.2349692 0094-2405
    • Li T F, Xing L, Munro P, McGuinness C, Chao M, Yang Y, Loo B and Koong A 2006 Four-dimensional cone-beam computed tomography using an on-board imager Med. Phys. 33 3825-33
    • (2006) Med. Phys. , vol.33 , Issue.10 , pp. 3825-3833
    • Li, T.F.1    Xing, L.2    Munro, P.3    McGuinness, C.4    Chao, M.5    Yang, Y.6    Loo, B.7    Koong, A.8
  • 28
    • 84857870461 scopus 로고    scopus 로고
    • The use and QA of biologically related models for treatment planning: Short report of the TG-166 of the therapy physics committee of the AAPM(a)
    • 10.1118/1.3685447 0094-2405
    • Li X A et al 2012 The use and QA of biologically related models for treatment planning: short report of the TG-166 of the therapy physics committee of the AAPM(a) Med. Phys. 39 1386-409
    • (2012) Med. Phys. , vol.39 , Issue.3 , pp. 1386-1409
    • Li, X.A.1
  • 29
    • 10044243676 scopus 로고    scopus 로고
    • Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part II - Margin reduction of internal target volume
    • 10.1016/j.ijrobp.2004.05.054 0360-3016
    • Liu H H, Koch N, Starkschall G, Jacobson M, Forster K, Liao Z X, Komaki R and Stevens C W 2004 Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: part II - margin reduction of internal target volume Int. J. Radiat. Oncol. Biol. Phys. 60 1473-83
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.60 , Issue.5 , pp. 1473-1483
    • Liu, H.H.1    Koch, N.2    Starkschall, G.3    Jacobson, M.4    Forster, K.5    Liao, Z.X.6    Komaki, R.7    Stevens, C.W.8
  • 30
    • 58149214088 scopus 로고    scopus 로고
    • Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging
    • 10.1088/0031-9155/53/24/013 0031-9155
    • Liu W, Wiersma R D, Mao W, Luxton G and Xing L 2008 Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging Phys. Med. Biol. 53 7197-213
    • (2008) Phys. Med. Biol. , vol.53 , Issue.24 , pp. 7197-7213
    • Liu, W.1    Wiersma, R.D.2    Mao, W.3    Luxton, G.4    Xing, L.5
  • 31
    • 78149329143 scopus 로고    scopus 로고
    • Two new DOSXYZnrc sources for 4D Monte Carlo simulations of continuously variable beam configurations, with applications to RapidArc, VMAT, TomoTherapy and CyberKnife
    • 10.1088/0031-9155/55/16/S01 0031-9155
    • Lobo J and Popescu I A 2010 Two new DOSXYZnrc sources for 4D Monte Carlo simulations of continuously variable beam configurations, with applications to RapidArc, VMAT, TomoTherapy and CyberKnife Phys. Med. Biol. 55 4431-43
    • (2010) Phys. Med. Biol. , vol.55 , Issue.16 , pp. 4431-4443
    • Lobo, J.1    Popescu, I.A.2
  • 33
    • 78149451120 scopus 로고    scopus 로고
    • Inverse planning for four-dimensional (4D) volumetric modulated arc therapy
    • 10.1118/1.3497271 0094-2405
    • Ma Y, Chang D, Keall P, Xie Y, Park J, Suh T and Xing L 2010 Inverse planning for four-dimensional (4D) volumetric modulated arc therapy Med. Phys. 37 5627-33
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 5627-5633
    • Ma, Y.1    Chang, D.2    Keall, P.3    Xie, Y.4    Park, J.5    Suh, T.6    Xing, L.7
  • 34
    • 66449122447 scopus 로고    scopus 로고
    • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields
    • 10.1118/1.3121425 0094-2405
    • Ma Y, Lee L, Keshet O, Keall P and Xing L 2009 Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields Med. Phys. 36 2215-21
    • (2009) Med. Phys. , vol.36 , Issue.6 , pp. 2215-2221
    • Ma, Y.1    Lee, L.2    Keshet, O.3    Keall, P.4    Xing, L.5
  • 36
    • 77951887281 scopus 로고    scopus 로고
    • Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo
    • 10.1088/0031-9155/55/5/014 0031-9155
    • McGurk R, Seco J, Riboldi M, Wolfgang J, Segars P and Paganetti H 2010 Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo Phys. Med. Biol. 55 1475-90
    • (2010) Phys. Med. Biol. , vol.55 , Issue.5 , pp. 1475-1490
    • McGurk, R.1    Seco, J.2    Riboldi, M.3    Wolfgang, J.4    Segars, P.5    Paganetti, H.6
  • 37
    • 48349129953 scopus 로고    scopus 로고
    • Target-tracking deliveries using conventional multileaf collimators planned with 4D direct-aperture optimization
    • 10.1088/0031-9155/53/15/001 0031-9155
    • McQuaid D and Webb S 2008 Target-tracking deliveries using conventional multileaf collimators planned with 4D direct-aperture optimization Phys. Med. Biol. 53 4013-29
    • (2008) Phys. Med. Biol. , vol.53 , Issue.15 , pp. 4013-4029
    • McQuaid, D.1    Webb, S.2
  • 38
    • 77952588130 scopus 로고    scopus 로고
    • Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArc
    • 0031-9155 N01
    • Nicolini G, Vanetti E, Clivio A, Fogliata A and Cozzi L 2010 Pre-clinical evaluation of respiratory-gated delivery of volumetric modulated arc therapy with RapidArc Phys. Med. Biol. 55 N347-57
    • (2010) Phys. Med. Biol. , vol.55 , Issue.12
    • Nicolini, G.1    Vanetti, E.2    Clivio, A.3    Fogliata, A.4    Cozzi, L.5
  • 39
    • 78149294033 scopus 로고    scopus 로고
    • Motion management with phase-adapted 4D-optimization
    • 10.1088/0031-9155/55/17/019 0031-9155
    • Nohadani O, Seco J and Bortfeld T 2010 Motion management with phase-adapted 4D-optimization Phys. Med. Biol. 55 5189-202
    • (2010) Phys. Med. Biol. , vol.55 , Issue.17 , pp. 5189-5202
    • Nohadani, O.1    Seco, J.2    Bortfeld, T.3
  • 40
    • 78651475739 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for peripheral lung tumors: A comparison of volumetric modulated arc therapy with 3 other delivery techniques
    • 10.1016/j.radonc.2010.09.027 0167-8140
    • Ong C L, Verbakel W F A R, Cuijpers J P, Slotman B J, Lagerwaard F J and Senan S 2010 Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques Radiother. Oncol. 97 437-42
    • (2010) Radiother. Oncol. , vol.97 , Issue.3 , pp. 437-442
    • Ong, C.L.1    Verbakel, W.F.A.R.2    Cuijpers, J.P.3    Slotman, B.J.4    Lagerwaard, F.J.5    Senan, S.6
  • 42
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • 10.1118/1.2818738 0094-2405
    • Otto K 2008 Volumetric modulated arc therapy: IMRT in a single gantry arc Med. Phys. 35 310-7
    • (2008) Med. Phys. , vol.35 , Issue.1 , pp. 310-317
    • Otto, K.1
  • 43
    • 79951864385 scopus 로고    scopus 로고
    • Impact of introducing stereotactic lung radiotherapy for elderly patients with stage i non-small-cell lung cancer: A population-based time-trend analysis
    • 10.1200/JCO.2010.30.0731 0732-183X
    • Palma D, Visser O, Lagerwaard F J, Belderbos J, Slotman B J and Senan S 2010 impact of introducing stereotactic lung radiotherapy for elderly patients with stage I non-small-cell lung cancer: a population-based time-trend analysis J. Clin. Oncol. 28 5153-9
    • (2010) J. Clin. Oncol. , vol.28 , Issue.35 , pp. 5153-5159
    • Palma, D.1    Visser, O.2    Lagerwaard, F.J.3    Belderbos, J.4    Slotman, B.J.5    Senan, S.6
  • 44
    • 36649014027 scopus 로고    scopus 로고
    • 4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy
    • 10.1118/1.2804722 0094-2405
    • Papiez L, McMahon R and Timmerman R 2007 4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy Med. Phys. 34 4952-6
    • (2007) Med. Phys. , vol.34 , Issue.12 , pp. 4952-4956
    • Papiez, L.1    McMahon, R.2    Timmerman, R.3
  • 45
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • 10.1118/1.1987967 0094-2405
    • Papiez L, Rangaraj D and Keall P 2005 Real-time DMLC IMRT delivery for mobile and deforming targets Med. Phys. 32 3037-48
    • (2005) Med. Phys. , vol.32 , Issue.9 , pp. 3037-3048
    • Papiez, L.1    Rangaraj, D.2    Keall, P.3
  • 46
    • 84863517865 scopus 로고    scopus 로고
    • A new column-generation-based algorithm for VMAT treatment plan optimization
    • 10.1088/0031-9155/57/14/4569 0031-9155
    • Peng F, Jia X, Gu X, Epelman M A, Romeijn H E and Jiang S B 2012 A new column-generation-based algorithm for VMAT treatment plan optimization Phys. Med. Biol. 57 4569-88
    • (2012) Phys. Med. Biol. , vol.57 , Issue.14 , pp. 4569-4588
    • Peng, F.1    Jia, X.2    Gu, X.3    Epelman, M.A.4    Romeijn, H.E.5    Jiang, S.B.6
  • 47
    • 33746883517 scopus 로고    scopus 로고
    • Therapy monitoring using dynamic MRI: Analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy
    • 10.1007/s00330-006-0237-y 0938-7994
    • Plathow C et al 2006 Therapy monitoring using dynamic MRI: analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy Eur. Radiol. 16 1942-50
    • (2006) Eur. Radiol. , vol.16 , Issue.9 , pp. 1942-1950
    • Plathow, C.1
  • 48
    • 79961060294 scopus 로고    scopus 로고
    • Dose verification for respiratory-gated volumetric modulated arc therapy
    • 10.1088/0031-9155/56/15/013 0031-9155
    • Qian J, Xing L, Liu W and Luxton G 2011 Dose verification for respiratory-gated volumetric modulated arc therapy Phys. Med. Biol. 56 4827-38
    • (2011) Phys. Med. Biol. , vol.56 , Issue.15 , pp. 4827-4838
    • Qian, J.1    Xing, L.2    Liu, W.3    Luxton, G.4
  • 49
    • 35848935434 scopus 로고    scopus 로고
    • Adaptive prediction of respiratory motion for motion compensation radiotherapy
    • 10.1088/0031-9155/52/22/007 0031-9155
    • Ren Q, Nishioka S, Shirato H and Berbeco R I 2007 Adaptive prediction of respiratory motion for motion compensation radiotherapy Phys. Med. Biol. 52 6651-61
    • (2007) Phys. Med. Biol. , vol.52 , Issue.22 , pp. 6651-6661
    • Ren, Q.1    Nishioka, S.2    Shirato, H.3    Berbeco, R.I.4
  • 50
    • 70350649031 scopus 로고    scopus 로고
    • Predicting respiratory tumor motion with multi-dimensional adaptive filters and support vector regression
    • 10.1088/0031-9155/54/19/005 0031-9155
    • Riaz N, Shanker P, Wiersma R, Gudmundsson O, Mao W, Widrow B and Xing L 2009 Predicting respiratory tumor motion with multi-dimensional adaptive filters and support vector regression Phys. Med. Biol. 54 5735-48
    • (2009) Phys. Med. Biol. , vol.54 , Issue.19 , pp. 5735-5748
    • Riaz, N.1    Shanker, P.2    Wiersma, R.3    Gudmundsson, O.4    Mao, W.5    Widrow, B.6    Xing, L.7
  • 51
    • 33645011292 scopus 로고    scopus 로고
    • Feasibility of four-dimensional conformal planning for robotic radiosurgery
    • 10.1118/1.2122607 0094-2405
    • Schlaefer A, Fisseler J, Dieterich S, Shiomi H, Cleary K and Schweikard A 2005 Feasibility of four-dimensional conformal planning for robotic radiosurgery Med. Phys. 32 3786-92
    • (2005) Med. Phys. , vol.32 , Issue.12 , pp. 3786-3792
    • Schlaefer, A.1    Fisseler, J.2    Dieterich, S.3    Shiomi, H.4    Cleary, K.5    Schweikard, A.6
  • 52
    • 0037962451 scopus 로고    scopus 로고
    • Comparison of IMRT optimization based on a pencil beam and a superposition algorithm
    • 10.1118/1.1586452 0094-2405
    • Scholz C, Nill S and Oelfke U 2003 Comparison of IMRT optimization based on a pencil beam and a superposition algorithm Med. Phys. 30 1909-13
    • (2003) Med. Phys. , vol.30 , Issue.7 , pp. 1909-1913
    • Scholz, C.1    Nill, S.2    Oelfke, U.3
  • 53
    • 49749088670 scopus 로고    scopus 로고
    • Developing and evaluating stereotactic lung RT trials: What we should know about the influence of inhomogeneity corrections on dose
    • 10.1186/1748-717X-3-21 1748-717X
    • Schuring D and Hurkmans C W 2008 Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose Radiat. Oncol. 3 21
    • (2008) Radiat. Oncol. , vol.3 , Issue.1 , pp. 21
    • Schuring, D.1    Hurkmans, C.W.2
  • 55
    • 78149325717 scopus 로고    scopus 로고
    • On developing B-spline registration algorithms for multi-core processors
    • 10.1088/0031-9155/55/21/001 0031-9155
    • Shackleford J A, Kandasamy N and Sharp G C 2010 On developing B-spline registration algorithms for multi-core processors Phys. Med. Biol. 55 6329-51
    • (2010) Phys. Med. Biol. , vol.55 , Issue.21 , pp. 6329-6351
    • Shackleford, J.A.1    Kandasamy, N.2    Sharp, G.C.3
  • 56
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • 10.1016/S0360-3016(00)00748-3 0360-3016
    • Shirato H et al 2000 Physical aspects of a real-time tumor-tracking system for gated radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 48 1187-95
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.4 , pp. 1187-1195
    • Shirato, H.1
  • 57
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • 10.1118/1.1869074 0094-2405
    • Sonke J J, Zijp L, Remeijer P and van Herk M 2005 Respiratory correlated cone beam CT Med. Phys. 32 1176-86
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 1176-1186
    • Sonke, J.J.1    Zijp, L.2    Remeijer, P.3    Van Herk, M.4
  • 58
    • 0029874819 scopus 로고    scopus 로고
    • Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam data
    • 10.1088/0031-9155/41/4/005 0031-9155
    • Storchi P and Woudstra E 1996 Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam data Phys. Med. Biol. 41 637-56
    • (1996) Phys. Med. Biol. , vol.41 , Issue.4 , pp. 637-656
    • Storchi, P.1    Woudstra, E.2
  • 59
    • 0032785775 scopus 로고    scopus 로고
    • Calculation of a pencil beam kernel from measured photon beam data
    • 10.1088/0031-9155/44/12/305 0031-9155
    • Storchi P R M, van Battum L J and Woudstra E 1999 Calculation of a pencil beam kernel from measured photon beam data Phys. Med. Biol. 44 2917-28
    • (1999) Phys. Med. Biol. , vol.44 , Issue.12 , pp. 2917-2928
    • Storchi, P.R.M.1    Van Battum, L.J.2    Woudstra, E.3
  • 60
    • 47649126554 scopus 로고    scopus 로고
    • An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients
    • 10.1088/0031-9155/53/13/016 0031-9155
    • Suh Y, Dieterich S, Cho B and Keall P J 2008a An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients Phys. Med. Biol. 53 3623-40
    • (2008) Phys. Med. Biol. , vol.53 , Issue.13 , pp. 3623-3640
    • Suh, Y.1    Dieterich, S.2    Cho, B.3    Keall, P.J.4
  • 61
    • 70149108974 scopus 로고    scopus 로고
    • Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm
    • 10.1088/0031-9155/54/12/014 0031-9155
    • Suh Y, Sawant A, Venkat R and Keall P J 2009 Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm Phys. Med. Biol. 54 3821-35
    • (2009) Phys. Med. Biol. , vol.54 , Issue.12 , pp. 3821-3835
    • Suh, Y.1    Sawant, A.2    Venkat, R.3    Keall, P.J.4
  • 62
    • 47149084580 scopus 로고    scopus 로고
    • A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery
    • 10.1016/j.ijrobp.2008.04.018 0360-3016
    • Suh Y, Weiss E, Zhong H, Fatyga M, Siebers J V and Keall P J 2008b A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery Int. J. Radiat. Oncol. Biol. Phys. 71 1526-36
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.71 , Issue.5 , pp. 1526-1536
    • Suh, Y.1    Weiss, E.2    Zhong, H.3    Fatyga, M.4    Siebers, J.V.5    Keall, P.J.6
  • 63
    • 78650165392 scopus 로고    scopus 로고
    • Target tracking using DMLC for volumetric modulated arc therapy: A simulation study
    • 10.1118/1.3511516 0094-2405
    • Sun B, Rangaraj D, Papiez L, Oddiraju S, Yang D and Li H H 2010 Target tracking using DMLC for volumetric modulated arc therapy: a simulation study Med. Phys. 37 6116-24
    • (2010) Med. Phys. , vol.37 , Issue.12 , pp. 6116-6124
    • Sun, B.1    Rangaraj, D.2    Papiez, L.3    Oddiraju, S.4    Yang, D.5    Li, H.H.6
  • 64
    • 33750612133 scopus 로고    scopus 로고
    • Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early-stage lung cancer
    • 10.1200/JCO.2006.07.5937 0732-183X
    • Timmerman R et al 2006 Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early-stage lung cancer J. Clin. Oncol. 24 4833-9
    • (2006) J. Clin. Oncol. , vol.24 , Issue.30 , pp. 4833-4839
    • Timmerman, R.1
  • 65
    • 20044385935 scopus 로고    scopus 로고
    • Temporo-spatial IMRT optimization: Concepts, implementation and initial results
    • 10.1088/0031-9155/50/12/004 0031-9155
    • Trofimov A, Rietzel E, Lu H M, Martin B, Jiang S, Chen G T Y and Bortfeld T 2005 Temporo-spatial IMRT optimization: concepts, implementation and initial results Phys. Med. Biol. 50 2779-98
    • (2005) Phys. Med. Biol. , vol.50 , Issue.12 , pp. 2779-2798
    • Trofimov, A.1    Rietzel, E.2    Lu, H.M.3    Martin, B.4    Jiang, S.5    Chen, G.T.Y.6    Bortfeld, T.7
  • 66
    • 0034762764 scopus 로고    scopus 로고
    • Determining parameters for respiration-gated radiotherapy
    • 10.1118/1.1406524 0094-2405
    • Vedam S S, Keall P J, Kini V R and Mohan R 2001 Determining parameters for respiration-gated radiotherapy Med. Phys. 28 2139-46
    • (2001) Med. Phys. , vol.28 , Issue.10 , pp. 2139-2146
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3    Mohan, R.4
  • 67
    • 45749086196 scopus 로고    scopus 로고
    • Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform
    • 0031-9155 N01
    • Venkat R B, Sawant A, Suh Y, George R and Keall P J 2008 Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform Phys. Med. Biol. 53 N197-208
    • (2008) Phys. Med. Biol. , vol.53 , Issue.11
    • Venkat, R.B.1    Sawant, A.2    Suh, Y.3    George, R.4    Keall, P.J.5
  • 68
    • 70349784432 scopus 로고    scopus 로고
    • Synchronized moving aperture radiation therapy (SMART): Superimposing tumor motion on IMRT MLC leaf sequences under realistic delivery conditions
    • 10.1088/0031-9155/54/16/010 0031-9155
    • Xu J, Papanikolaou N, Shi C and Jiang S B 2009 Synchronized moving aperture radiation therapy (SMART): superimposing tumor motion on IMRT MLC leaf sequences under realistic delivery conditions Phys. Med. Biol. 54 4993-5007
    • (2009) Phys. Med. Biol. , vol.54 , Issue.16 , pp. 4993-5007
    • Xu, J.1    Papanikolaou, N.2    Shi, C.3    Jiang, S.B.4
  • 69
    • 52949101684 scopus 로고    scopus 로고
    • 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling
    • 10.1118/1.2977828 0094-2405
    • Yang D, Lu W, Low D A, Deasy J O, Hope A J and El Naqa I 2008 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling Med. Phys. 35 4577-90
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4577-4590
    • Yang, D.1    Lu, W.2    Low, D.A.3    Deasy, J.O.4    Hope, A.J.5    El Naqa, I.6
  • 70
    • 50449102689 scopus 로고    scopus 로고
    • Real-time tumor tracking with preprogrammed dynamic multileaf-collimator motion and adaptive dose-rate regulation
    • 10.1118/1.2965261 0094-2405
    • Yi B Y, Han-Oh S, Lerma F, Berman B L and Yu C 2008 Real-time tumor tracking with preprogrammed dynamic multileaf-collimator motion and adaptive dose-rate regulation Med. Phys. 35 3955-62
    • (2008) Med. Phys. , vol.35 , Issue.9 , pp. 3955-3962
    • Yi, B.Y.1    Han-Oh, S.2    Lerma, F.3    Berman, B.L.4    Yu, C.5
  • 71
    • 80255123742 scopus 로고    scopus 로고
    • Which is the optimal biologically effective dose of stereotactic body radiotherapy for stage i non-small-cell lung cancer? A meta-analysis
    • 10.1016/j.ijrobp.2011.04.034 0360-3016
    • Zhang J, Yang F, Li B, Li H, Liu J, Huang W, Wang D, Yi Y and Wang J 2011a Which is the optimal biologically effective dose of stereotactic body radiotherapy for stage I non-small-cell lung cancer? A meta-analysis Int. J. Radiat. Oncol. Biol. Phys. 81 E305-16
    • (2011) Int. J. Radiat. Oncol. Biol. Phys. , vol.81 , Issue.4
    • Zhang, J.1    Yang, F.2    Li, B.3    Li, H.4    Liu, J.5    Huang, W.6    Wang, D.7    Yi, Y.8    Wang, J.9
  • 72
    • 84866102821 scopus 로고    scopus 로고
    • Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy
    • 10.1118/1.4742846 0094-2405
    • Zhang P, Hunt M, Happersett L, Cox B and Mageras G 2012 Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy Med. Phys. 39 5429-36
    • (2012) Med. Phys. , vol.39 , Issue.9 , pp. 5429-5436
    • Zhang, P.1    Hunt, M.2    Happersett, L.3    Cox, B.4    Mageras, G.5
  • 73
    • 79960243594 scopus 로고    scopus 로고
    • Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy
    • 10.1118/1.3596776 0094-2405
    • Zhang P, Mah D, Happersett L, Cox B, Hunt M and Mageras G 2011b Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy Med. Phys. 38 4001-8
    • (2011) Med. Phys. , vol.38 , Issue.7 , pp. 4001-4008
    • Zhang, P.1    Mah, D.2    Happersett, L.3    Cox, B.4    Hunt, M.5    Mageras, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.