메뉴 건너뛰기




Volumn 34, Issue 12, 2007, Pages 4952-4956

4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy

Author keywords

4D IMRT; DMLC delivery; Moving body anatomy

Indexed keywords

BIOMEDICAL ENGINEERING;

EID: 36649014027     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2804722     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 33745492583 scopus 로고    scopus 로고
    • Motion effects in (intensity modulated) radiation therapy: A review
    • S. Webb, " Motion effects in (intensity modulated) radiation therapy: A review., " Phys. Med. Biol. 51, R403-R425 (2006).
    • (2006) Phys. Med. Biol. , vol.51
    • Webb, S.1
  • 4
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • T. Bortfeld, K. Jokivarsi, M. Goitein, J. Kung, and S. B. Jiang, " Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation., " Phys. Med. Biol. 47, 2203-2220 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 5
    • 0842327792 scopus 로고    scopus 로고
    • Effects of motion on the total dose distribution
    • T. Bortfeld, S. B. Jiang, and E. Rietzel, " Effects of motion on the total dose distribution., " Semin. Radiat. Oncol. 14, 41-51 (2004).
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 41-51
    • Bortfeld, T.1    Jiang, S.B.2    Rietzel, E.3
  • 6
    • 33745498842 scopus 로고    scopus 로고
    • Optimization of IMRT: Can geometrical uncertainties be incorporated into the optimization process?
    • M. Loof, P. Engstrom, K. Uttman, and H. Nystrom, " Optimization of IMRT: Can geometrical uncertainties be incorporated into the optimization process?, " Radiother. Oncol. 61 (Suppl. 1) S66 (2001).
    • (2001) Radiother. Oncol. , vol.61 , Issue.1 SUPPL. , pp. 66
    • Loof, M.1    Engstrom, P.2    Uttman, K.3    Nystrom, H.4
  • 7
    • 0033867216 scopus 로고    scopus 로고
    • Inverse planning incorporating organ motion
    • J. G. Li and L. Xing, " Inverse planning incorporating organ motion., " Med. Phys. 27, 1573-1579 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1573-1579
    • Li, J.G.1    Xing, L.2
  • 8
    • 17844389898 scopus 로고    scopus 로고
    • A stochastic convolution/superposition method with isocentre sampling to evaluate intrafraction motion effects in IMRT
    • S. Naqvi and W. D'Souza, " A stochastic convolution/superposition method with isocentre sampling to evaluate intrafraction motion effects in IMRT., " Med. Phys. 32, 1156-1163 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 1156-1163
    • Naqvi, S.1    D'Souza, W.2
  • 9
    • 4544356974 scopus 로고    scopus 로고
    • Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions
    • J. Unkelbach and U. Oelfke, " Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions., " Phys. Med. Biol. 49, 4005-4029 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4005-4029
    • Unkelbach, J.1    Oelfke, U.2
  • 11
    • 20044385935 scopus 로고    scopus 로고
    • Temporo-spatial IMRT optimization: Concepts, implementation and initial results
    • A. Trovimov, " Temporo-spatial IMRT optimization: Concepts, implementation and initial results., " Phys. Med. Biol. 50 (12), 2779-2798 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , Issue.12 , pp. 2779-2798
    • Trovimov, A.1
  • 12
    • 0035136220 scopus 로고    scopus 로고
    • Motion adaptive x-ray therapy: A feasibility study
    • P. J. Keall, V. R. Kini, S. S. Vedam, and R. Mohan, " Motion adaptive x-ray therapy: A feasibility study., " Phys. Med. Biol. 46, 1-10 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1-10
    • Keall, P.J.1    Kini, V.R.2    Vedam, S.S.3    Mohan, R.4
  • 13
    • 16444369980 scopus 로고    scopus 로고
    • The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (DMLC) technique
    • S. Webb, " The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (DMLC) technique., " Phys. Med. Biol. 50, 1163-1190 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1163-1190
    • Webb, S.1
  • 14
    • 7244242296 scopus 로고    scopus 로고
    • DMLC leaf-pair optimal control of IMRT delivery for a moving rigid target
    • L. Papiez, " DMLC leaf-pair optimal control of IMRT delivery for a moving rigid target., " Med. Phys. 31, 2742-2754 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2742-2754
    • Papiez, L.1
  • 15
    • 12844267410 scopus 로고    scopus 로고
    • DMLC leaf-pair optimal control for mobile, deforming targets
    • L. Papiez and D. Rangaraj, " DMLC leaf-pair optimal control for mobile, deforming targets., " Med. Phys. 32, 275-285 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 275-285
    • Papiez, L.1    Rangaraj, D.2
  • 16
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • L. Papiez, D. Rangaraj, and P. Keall, " Real-time DMLC IMRT delivery for mobile and deforming targets., " Med. Phys. 32, 3037-3049 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3037-3049
    • Papiez, L.1    Rangaraj, D.2    Keall, P.3
  • 17
    • 0038530967 scopus 로고    scopus 로고
    • The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
    • L. Papiez, " The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery., " Math. Comput. Modell. 37, 735-745 (2003).
    • (2003) Math. Comput. Modell. , vol.37 , pp. 735-745
    • Papiez, L.1
  • 18
    • 0142089327 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: Sensitivity to variations in motion
    • A. E. Lujan, J. Balter, and R. Ten Haken, " A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: Sensitivity to variations in motion., " Med. Phys. 30, 2643-2649 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2643-2649
    • Lujan, A.E.1    Balter, J.2    Ten Haken, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.