메뉴 건너뛰기




Volumn 30, Issue 1, 2003, Pages 88-97

Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning

Author keywords

Computed tomography; Gated radiotherapy; Respiratory motion

Indexed keywords

PATIENT MONITORING; PHANTOMS; RADIOTHERAPY; RESPIRATORY MECHANICS; SPHERES; TUMORS; X RAY TUBES;

EID: 0037237809     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1531177     Document Type: Article
Times cited : (355)

References (19)
  • 1
    • 0034006554 scopus 로고    scopus 로고
    • Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center
    • H. D. Kubo, P. M. Len, S. Minohara, and H. Mostafavi, "Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center," Med. Phys. 27, 346-353 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 346-353
    • Kubo, H.D.1    Len, P.M.2    Minohara, S.3    Mostafavi, H.4
  • 2
    • 0000697171 scopus 로고    scopus 로고
    • Preliminary results from a study of a respiratory motion tracking system: Underestimation of target volume with conventional CT simulation
    • V. R. Kini, P. J. Keall, S. S. Vedam, D. W. Arthur, B. D. Kavanagh, R. M. Cardinale, and R. Mohan, "Preliminary results from a study of a respiratory motion tracking system: Underestimation of target volume with conventional CT simulation," Int. J. Radiat. Oncol., Biol., Phys. 48(Suppl. 1), 164 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.48 , Issue.SUPPL. 1 , pp. 164
    • Kini, V.R.1    Keall, P.J.2    Vedam, S.S.3    Arthur, D.W.4    Kavanagh, B.D.5    Cardinale, R.M.6    Mohan, R.7
  • 3
    • 0032704370 scopus 로고    scopus 로고
    • A comparison of beam characteristics for gated and nongated clinical x-ray beams
    • C. R. Ramsey, I. L. Cordrey, and A. L. Oliver, "A comparison of beam characteristics for gated and nongated clinical x-ray beams," Med. Phys. 26, 2086-2091 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2086-2091
    • Ramsey, C.R.1    Cordrey, I.L.2    Oliver, A.L.3
  • 5
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: A technical study
    • H. D. Kubo and B. C. Hill, "Respiration gated radiotherapy treatment: A technical study," Phys. Med. Biol. 41, 83-91 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 6
    • 0033007343 scopus 로고    scopus 로고
    • Clinical efficacy of respiratory gated conformal radiation therapy
    • C. R. Ramsey, D. Scaperoth, D. Arwood, and A. L. Oliver, "Clinical efficacy of respiratory gated conformal radiation therapy," Med. Dosim. 24, 115-119 (1999).
    • (1999) Med. Dosim. , vol.24 , pp. 115-119
    • Ramsey, C.R.1    Scaperoth, D.2    Arwood, D.3    Oliver, A.L.4
  • 9
    • 0033799790 scopus 로고    scopus 로고
    • A novel tracking technique for the continuous precise measurement of tumor positions in conformal radiotherapy
    • P. G. Seiler, H. Blattmann, S. Kirsch, R. K. Muench, and C. H. Schilling, "A novel tracking technique for the continuous precise measurement of tumor positions in conformal radiotherapy," Phys. Med. Biol. 45, N103-110 (2000).
    • (2000) Phys. Med. Biol. , vol.45
    • Seiler, P.G.1    Blattmann, H.2    Kirsch, S.3    Muench, R.K.4    Schilling, C.H.5
  • 13
    • 0032414773 scopus 로고    scopus 로고
    • Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • M. Kachelriess and W. A. Kalender, "Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart," Med. Phys. 25, 2417-2431 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2417-2431
    • Kachelriess, M.1    Kalender, W.A.2
  • 15
    • 0033019143 scopus 로고    scopus 로고
    • A general methodology for three-dimensional analysis of variation in target volume delineation
    • P. Remeijer, C. Rasch, J. V. Lebesque, and M. van Herk, "A general methodology for three-dimensional analysis of variation in target volume delineation," Med. Phys. 26, 931-940 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 931-940
    • Remeijer, P.1    Rasch, C.2    Lebesque, J.V.3    Van Herk, M.4
  • 19
    • 0032941481 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculation
    • A. E. Lujan, E. W. Larsen, J. M. Balter, and R. K. Ten Haken, "A method for incorporating organ motion due to breathing into 3D dose calculation," Med. Phys. 26, 715-720 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 715-720
    • Lujan, A.E.1    Larsen, E.W.2    Balter, J.M.3    Ten Haken, R.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.