메뉴 건너뛰기




Volumn 5, Issue 3, 2013, Pages 267-269

Antibody-free PRISM-SRM for multiplexed protein quantification: Is this the new competition for immunoassays in bioanalysis?

Author keywords

high resolution separations; immunoassay; intelligent selection; multiplexed assays; proteomics; sensitivity; SRM; targeted quantification

Indexed keywords

PEPTIDE; PLASMA PROTEIN; PROSTATE SPECIFIC ANTIGEN; PROTEIN; PROTEIN ANTIBODY;

EID: 84873573303     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.12.336     Document Type: Review
Times cited : (19)

References (19)
  • 1
    • 84860854049 scopus 로고    scopus 로고
    • Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics
    • Shi T, Su D, Liu T et al. Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics. Proteomics 12(8), 1074-1092 (2012
    • (2012) Proteomics , vol.12 , Issue.8 , pp. 1074-1092
    • Shi, T.1    Su, D.2    Liu, T.3
  • 2
    • 79960214321 scopus 로고    scopus 로고
    • A targeted proteomics-based pipeline for verification of biomarkers in plasma
    • Whiteaker JR, Lin C, Kennedy J et al. A targeted proteomics-based pipeline for verification of biomarkers in plasma. Nat. Biotechnol. 29(7), 625-634 (2011
    • (2011) Nat. Biotechnol , vol.29 , Issue.7 , pp. 625-634
    • Whiteaker, J.R.1    Lin, C.2    Kennedy, J.3
  • 3
    • 75749095246 scopus 로고    scopus 로고
    • The bottleneck in the cancer biomarker pipeline and protein quantification through mass spectrometry-based approaches: Current strategies for candidate verification
    • Makawita S, Diamandis EP. The bottleneck in the cancer biomarker pipeline and protein quantification through mass spectrometry-based approaches: Current strategies for candidate verification. Clin. Chem. 56(2), 212-222 (2010
    • (2010) Clin. Chem , vol.56 , Issue.2 , pp. 212-222
    • Makawita, S.1    Diamandis, E.P.2
  • 4
    • 38349068918 scopus 로고    scopus 로고
    • Quantitative, multiplexed assays for low abundance proteins in plasma by targeted mass spectrometry and stable isotope dilution
    • Keshishian H, Addona T, Burgess M, Kuhn E, Carr SA. Quantitative, multiplexed assays for low abundance proteins in plasma by targeted mass spectrometry and stable isotope dilution. Mol. Cell. Proteomics 6(12), 2212-2229 (2007
    • (2007) Mol. Cell. Proteomics , vol.6 , Issue.12 , pp. 2212-2229
    • Keshishian, H.1    Addona, T.2    Burgess, M.3    Kuhn, E.4    Carr, S.A.5
  • 5
    • 33747030845 scopus 로고    scopus 로고
    • Protein biomarker discovery and validation: The long and uncertain path to clinical utility
    • Rifai N, Gillette MA, Carr SA. Protein biomarker discovery and validation:the long and uncertain path to clinical utility. Nat. Biotechnol. 24(8), 971-983 (2006
    • (2006) Nat. Biotechnol , vol.24 , Issue.8 , pp. 971-983
    • Rifai, N.1    Gillette, M.A.2    Carr, S.A.3
  • 6
    • 43049090085 scopus 로고    scopus 로고
    • Targeted quantitative analysis of Streptococcus pyogenes virulence factors by multiple reaction monitoring
    • Lange V, Malmstrom JA, Didion J et al. Targeted quantitative analysis of Streptococcus pyogenes virulence factors by multiple reaction monitoring. Mol. Cell. Proteomics 7(8), 1489-1500 (2008
    • (2008) Mol. Cell. Proteomics , vol.7 , Issue.8 , pp. 1489-1500
    • Lange, V.1    Malmstrom, J.A.2    Didion, J.3
  • 7
    • 84861990380 scopus 로고    scopus 로고
    • Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions
    • Picotti P, Aebersold R. Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions. Nat. Methods 9(6), 555-566 (2012
    • (2012) Nat. Methods , vol.9 , Issue.6 , pp. 555-566
    • Picotti, P.1    Aebersold, R.2
  • 8
    • 84866538934 scopus 로고    scopus 로고
    • Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum
    • Shi T, Fillmore TL, Sun X et al. Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum. Proc. Natl Acad. Sci. USA 109(38), 15395-15400 (2012
    • (2012) Proc. Natl Acad. Sci. USA , vol.109 , Issue.38 , pp. 15395-15400
    • Shi, T.1    Fillmore, T.L.2    Sun, X.3
  • 9
    • 67650564834 scopus 로고    scopus 로고
    • Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma
    • Addona TA, Abbatiello SE, Schilling B et al. Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma. Nat. Biotechnol. 27(7), 633-641 (2009
    • (2009) Nat. Biotechnol , vol.27 , Issue.7 , pp. 633-641
    • Addona, T.A.1    Abbatiello, S.E.2    Schilling, B.3
  • 10
    • 84860880032 scopus 로고    scopus 로고
    • Inter-laboratory evaluation of automated, multiplexed peptide immunoaffinity enrichment coupled to multiple reaction monitoring mass spectrometry for quantifying proteins in plasma
    • M111.013854
    • Kuhn E, Whiteaker JR, Mani DR et al. Inter-laboratory evaluation of automated, multiplexed peptide immunoaffinity enrichment coupled to multiple reaction monitoring mass spectrometry for quantifying proteins in plasma. Mol. Cell. Proteomics 11(6), M111.013854 (2012
    • (2012) Mol. Cell. Proteomics , vol.11 , Issue.6
    • Kuhn, E.1    Whiteaker, J.R.2    Mani, D.R.3
  • 11
    • 68749094119 scopus 로고    scopus 로고
    • Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
    • Picotti P, Bodenmiller B, Mueller LN, Domon B, Aebersold R. Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics. Cell 138(4), 795-806 (2009
    • (2009) Cell , vol.138 , Issue.4 , pp. 795-806
    • Picotti, P.1    Bodenmiller, B.2    Mueller, L.N.3    Domon, B.4    Aebersold, R.5
  • 12
    • 84859312471 scopus 로고    scopus 로고
    • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures
    • Hoofnagle AN, Becker JO, Oda MN, Cavigiolio G, Mayer P, Vaisar T. Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures. Clin. Chem. 58(4), 777-781 (2012
    • (2012) Clin. Chem , vol.58 , Issue.4 , pp. 777-781
    • Hoofnagle, A.N.1    Becker, J.O.2    Oda, M.N.3    Cavigiolio, G.4    Mayer, P.5    Vaisar, T.6
  • 13
    • 33645721632 scopus 로고    scopus 로고
    • Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
    • Anderson L, Hunter CL. Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins. Mol. Cell. Proteomics 5(4), 573-588 (2006
    • (2006) Mol. Cell. Proteomics , vol.5 , Issue.4 , pp. 573-588
    • Anderson, L.1    Hunter, C.L.2
  • 14
    • 76649109590 scopus 로고    scopus 로고
    • An automated and multiplexed method for high throughput peptide immunoaffinity enrichment and multiple reaction monitoring mass spectrometry-based quantification of protein biomarkers
    • Whiteaker JR, Zhao L, Anderson L, Paulovich AG. An automated and multiplexed method for high throughput peptide immunoaffinity enrichment and multiple reaction monitoring mass spectrometry-based quantification of protein biomarkers. Mol. Cell. Proteomics 9(1), 184-196 (2010
    • (2010) Mol. Cell. Proteomics , vol.9 , Issue.1 , pp. 184-196
    • Whiteaker, J.R.1    Zhao, L.2    Anderson, L.3    Paulovich, A.G.4
  • 15
    • 84862317182 scopus 로고    scopus 로고
    • Sequential multiplexed analyte quantification using peptide immunoaffinity enrichment coupled to mass spectrometry
    • M111.015347
    • Whiteaker JR, Zhao L, Lin C, Yan P, Wang P, Paulovich AG. Sequential multiplexed analyte quantification using peptide immunoaffinity enrichment coupled to mass spectrometry. Mol. Cell. Proteomics 11(6), M111.015347 (2012
    • (2012) Mol. Cell. Proteomics , vol.11 , Issue.6
    • Whiteaker, J.R.1    Zhao, L.2    Lin, C.3    Yan, P.4    Wang, P.5    Paulovich, A.G.6
  • 16
    • 84856688004 scopus 로고    scopus 로고
    • Development of a chip/chip/ SRM platform using digital chip isoelectric focusing and LC-chip mass spectrometry for enrichment and quantitation of low abundance protein biomarkers in human plasma
    • Rafalko A, Dai SJ, Hancock WS, Karger BL, Hincapie M. Development of a chip/chip/ SRM platform using digital chip isoelectric focusing and LC-chip mass spectrometry for enrichment and quantitation of low abundance protein biomarkers in human plasma. J. Proteome Res. 11(2), 808-817 (2012
    • (2012) J. Proteome Res , vol.11 , Issue.2 , pp. 808-817
    • Rafalko, A.1    Dai, S.J.2    Hancock, W.S.3    Karger, B.L.4    Hincapie, M.5
  • 17
    • 79952284442 scopus 로고    scopus 로고
    • Mutant proteins as cancer-specific biomarkers
    • Wang Q, Chaerkady R, Wu J et al. Mutant proteins as cancer-specific biomarkers. Proc. Natl Acad. Sci. USA 108(6), 2444-2449 (2011
    • (2011) Proc. Natl Acad. Sci. USA , vol.108 , Issue.6 , pp. 2444-2449
    • Wang, Q.1    Chaerkady, R.2    Wu, J.3
  • 18
    • 34250722602 scopus 로고    scopus 로고
    • Multiple reaction monitoring for robust quantitative proteomic analysis of cellular signaling networks
    • Wolf-Yadlin A, Hautaniemi S, Lauffenburger DA, White FM. Multiple reaction monitoring for robust quantitative proteomic analysis of cellular signaling networks. Proc. Natl Acad. Sci. USA 104(14), 5860-5865 (2007
    • (2007) Proc. Natl Acad. Sci. USA , vol.104 , Issue.14 , pp. 5860-5865
    • Wolf-Yadlin, A.1    Hautaniemi, S.2    Lauffenburger, D.A.3    White, F.M.4
  • 19
    • 67650432879 scopus 로고    scopus 로고
    • The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
    • Hoofnagle AN, Wener MH. The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. J. Immunol. Methods 347(1-2), 3-11 (2009
    • (2009) J. Immunol. Methods , vol.347 , Issue.1-2 , pp. 3-11
    • Hoofnagle, A.N.1    Wener, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.