Preanalytical considerations in blood gas analysis

Author keywords

Blood gas analysis; Laboratory error; pCO2; pH; pO2; Preanalytical error

Indexed keywords

HEMOGLOBIN; HEPARIN;

EID: 84873565410     PISSN: 13300962     EISSN: None     Source Type: Journal    
DOI: 10.11613/BM.2013.005     Document Type: Review
Times cited : (62)

References (59)
  • 1
    • 0019571316 scopus 로고
    • Acting on significant laboratory results
    • Lundberg GD. Acting on significant laboratory results. JAMA 1981;245:1762-3. http://dx.doi.org/10.1001/jama.1981.03310420052033.
    • (1981) JAMA , vol.245 , pp. 1762-1763
    • Lundberg, G.D.1
  • 2
    • 82655171626 scopus 로고    scopus 로고
    • The brain-to-brain loop concept for laboratory testing 40 years after its introduction
    • Plebani M, Laposata M, Lundberg GD. The brain-to-brain loop concept for laboratory testing 40 years after its introduction. Am J Clin Pathol 2011;136:829-33. http://dx.doi.org/10.1309/AJCPR28HWHSSDNON.
    • (2011) Am J Clin Pathol , vol.136 , pp. 829-833
    • Plebani, M.1    Laposata, M.2    Lundberg, G.D.3
  • 3
    • 84859580769 scopus 로고    scopus 로고
    • Managing the pre- and post-analytical phases ofthe total testing process
    • Hawkins R. Managing the pre- and post-analytical phases ofthe total testing process. Ann Lab Med 2012;32:5-16. http://dx.doi.org/10.3343/alm.2012.32.1.5.
    • (2012) Ann Lab Med , vol.32 , pp. 5-16
    • Hawkins, R.1
  • 4
    • 10044274337 scopus 로고    scopus 로고
    • Medical errors: An introduction to concepts
    • Kalra J. Medical errors: An introduction to concepts. Clin Biochem 2004;37:1043-51. http://dx.doi.org/10.1016/j.clinbiochem.2004.08.007.
    • (2004) Clin Biochem , vol.37 , pp. 1043-1051
    • Kalra, J.1
  • 5
    • 10044255447 scopus 로고    scopus 로고
    • Medical errors: Impact on clinical laboratories and other critical areas
    • Kalra J. Medical errors: Impact on clinical laboratories and other critical areas. Clin Biochem 2004;37:1052-62. http://dx.doi.org/10.1016/j.clinbiochem.2004.08.009.
    • (2004) Clin Biochem , vol.37 , pp. 1052-1062
    • Kalra, J.1
  • 6
    • 10044278164 scopus 로고    scopus 로고
    • Medical errors: Overcoming the challenges
    • Kalra J. Medical errors: Overcoming the challenges. Clin Biochem 2004;37:1063-71. http://dx.doi.org/10.1016/j.clinbiochem.2004.08.008.
    • (2004) , vol.37 , pp. 1063-1071
    • Kalra, J.1
  • 7
    • 85047687808 scopus 로고    scopus 로고
    • Classifying laboratory incident reports to identify problems that jeopardize patient safety
    • Astion ML, Shojania KG, Hamill TR, Kim S, Ng VL. Classifying laboratory incident reports to identify problems that jeopardize patient safety. Am J Clin Pathol 2003;120:18-26. http://dx.doi.org/10.1309/8U5D0MA6MFH2FG19.
    • (2003) Am J Clin Pathol , vol.120 , pp. 18-26
    • Astion, M.L.1    Shojania, K.G.2    Hamill, T.R.3    Kim, S.4    Ng, V.L.5
  • 8
    • 77749240357 scopus 로고    scopus 로고
    • The detection and prevention of errors in laboratory medicine
    • Plebani M. The detection and prevention of errors in laboratory medicine. Ann Clin Biochem 2010;47:101-10. http://dx.doi.org/10.1258/acb.2009.009222.
    • (2010) Ann Clin Biochem , vol.47 , pp. 1101-1110
    • Plebani, M.1
  • 9
    • 84873550635 scopus 로고    scopus 로고
    • CLSI, approved guideline - second edition. Vol. CLSI Document C46-A2, Wayne, PA, Clinical and Laboratory Standards Institute
    • CLSI. Blood gas and ph analysis and related measurements; approved guideline - second edition. Vol. CLSI Document C46-A2. Wayne, PA: Clinical and Laboratory Standards Institute, 2010.
    • (2010) Blood Gas and Ph Analysis and Related Measurements
  • 10
    • 55349090859 scopus 로고
    • An apparatus for determination of the gases in blood and other solutions
    • Van Slyke DD. An apparatus for determination of the gases in blood and other solutions. Proc Natl Acad Sci U S A 1921;7:229-31. http://dx.doi.org/10.1073/pnas.7.8.229.
    • (1921) Proc Natl Acad Sci U S A , vol.7 , pp. 229-231
    • van Slyke, D.D.1
  • 11
    • 38349035800 scopus 로고    scopus 로고
    • New creatinine sensor for point-of-care testing of creatinine meets the national kidney disease education program guidelines
    • Skurup A, Kristensen T, Wennecke G, Group NKDEPLW. New creatinine sensor for point-of-care testing of creatinine meets the national kidney disease education program guidelines. Clin Chem Lab Med 2008;46:3-8. http://dx.doi.org/10.1515/CCLM.2008.004.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 3-8
    • Skurup, A.1    Kristensen, T.2    Wennecke, G.3    Group, N.K.D.E.P.L.W.4
  • 12
    • 43349107447 scopus 로고    scopus 로고
    • Evaluation of the gem premier 4000: A compact blood gas co-oximeter and electrolyte analyzer for point-of-care and laboratory testing
    • Bénéteau-Burnat B, Pernet P, Pilon A, Latour D, Goujon S, Feuillu A, Vaubourdolle M. Evaluation of the gem premier 4000: A compact blood gas co-oximeter and electrolyte analyzer for point-of-care and laboratory testing. Clin Chem Lab Med 2008;46:271-9. http://dx.doi.org/10.1515/CCLM.2008.043.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 271-279
    • Bénéteau-Burnat, B.1    Pernet, P.2    Pilon, A.3    Latour, D.4    Goujon, S.5    Feuillu, A.6    Vaubourdolle, M.7
  • 14
    • 0022481680 scopus 로고
    • Indications for arterial blood gas analysis
    • Raffin TA. Indications for arterial blood gas analysis. Ann Intern Med 1986;105:390-8.
    • (1986) Ann Intern Med , vol.105 , pp. 390-398
    • Raffin, T.A.1
  • 15
    • 33746697731 scopus 로고    scopus 로고
    • Reducing unnecessary inpatient laboratory testing in a teaching hospital
    • May TA, Clancy M, Critchfield J, Ebeling F, Enriquez A, Gallagher C, et al. Reducing unnecessary inpatient laboratory testing in a teaching hospital. Am J Clin Pathol 2006;126:200-6. http://dx.doi.org/10.1309/WP59YM73L6CEGX2F.
    • (2006) Am J Clin Pathol , vol.126 , pp. 200-206
    • May, T.A.1    Clancy, M.2    Critchfield, J.3    Ebeling, F.4    Enriquez, A.5    Gallagher, C.6
  • 17
    • 21044451606 scopus 로고    scopus 로고
    • An administrative intervention to improve the utilization of laboratory tests within a university hospital
    • Calderon-Margalit R, Mor-Yosef S, Mayer M, Adler B, Shapira SC. An administrative intervention to improve the utilization of laboratory tests within a university hospital. Int J Qual Health Care 2005;17:243-8. http://dx.doi.org/10.1093/intqhc/mzi025.
    • (2005) Int J Qual Health Care , vol.17 , pp. 243-248
    • Calderon-Margalit, R.1    Mor-Yosef, S.2    Mayer, M.3    Adler, B.4    Shapira, S.C.5
  • 18
    • 33748994801 scopus 로고    scopus 로고
    • A cost-effective method for reducing the volume of laboratory tests in a university-associated teaching hospital
    • Attali M, Barel Y, Somin M, Beilinson N, Shankman M, Ackerman A, Malnick SD. A cost-effective method for reducing the volume of laboratory tests in a university-associated teaching hospital. Mt Sinai J Med 2006;73:787-94.
    • (2006) Mt Sinai J Med , vol.73 , pp. 787-794
    • Attali, M.1    Barel, Y.2    Somin, M.3    Beilinson, N.4    Shankman, M.5    Ackerman, A.6    Malnick, S.D.7
  • 19
    • 0028857412 scopus 로고
    • Appropriate utilization and cost control of the hospital laboratory: Panel testing and repeat orders
    • Werner M. Appropriate utilization and cost control of the hospital laboratory: Panel testing and repeat orders. Clin Chim Acta 1995;233:1-17. http://dx.doi.org/10.1016/0009-8981-(94)05964-T.
    • (1995) Clin Chim Acta , vol.233 , pp. 1-17
    • Werner, M.1
  • 20
    • 0037048168 scopus 로고    scopus 로고
    • A utilization management intervention to reduce unnecessary testing in the coronary care unit
    • Wang TJ, Mort EA, Nordberg P, Chang Y, Cadigan ME, Mylott L, et al. A utilization management intervention to reduce unnecessary testing in the coronary care unit. Arch Intern Med 2002;162:1885-90. http://dx.doi.org/10.1001/archinte.162.16.1885.
    • (2002) Arch Intern Med , vol.162 , pp. 1885-1890
    • Wang, T.J.1    Mort, E.A.2    Nordberg, P.3    Chang, Y.4    Cadigan, M.E.5    Mylott, L.6
  • 21
    • 0025647787 scopus 로고
    • Inappropriate use of laboratory services: Long term combined approach to modify request patterns
    • Bareford D, Hayling A. Inappropriate use of laboratory services: Long term combined approach to modify request patterns. BMJ 1990;301:1305-7. http://dx.doi.org/10.1136/bmj.301.6764.1305.
    • (1990) BMJ , vol.301 , pp. 1305-1307
    • Bareford, D.1    Hayling, A.2
  • 22
    • 0023137955 scopus 로고
    • Biochemical profiles. Applications in ambulatory screening and preadmission testing of adults
    • Cebul RD, Beck JR. Biochemical profiles. Applications in ambulatory screening and preadmission testing of adults. Ann Intern Med 1987;106:403-13.
    • (1987) Ann Intern Med , vol.106 , pp. 403-413
    • Cebul, R.D.1    Beck, J.R.2
  • 23
    • 33645458623 scopus 로고    scopus 로고
    • Potentially inappropriate repeat laboratory testing in inpatients
    • Hawkins R. Potentially inappropriate repeat laboratory testing in inpatients. Clin Chem 2006;52:784-5. http://dx.doi.org/10.1373/clinchem.2005.064139.
    • (2006) Clin Chem , vol.52 , pp. 784-785
    • Hawkins, R.1
  • 24
    • 46249092920 scopus 로고    scopus 로고
    • What factors influence arterial blood gas sampling patterns?
    • Andrews T, Waterman H. What factors influence arterial blood gas sampling patterns? Nurs Crit Care 2008;13:132-7. http://dx.doi.org/10.1111/j.1478-5153.2008.00275.x.
    • (2008) Nurs Crit Care , vol.13 , pp. 132-137
    • Andrews, T.1    Waterman, H.2
  • 25
    • 0022515141 scopus 로고
    • Iatrogenic anemia
    • Henry ML, Garner WL, Fabri PJ. Iatrogenic anemia. Am J Surg 1986;151:362-3. http://dx.doi.org/10.1016/0002-9610(86)90468-X.
    • (1986) Am J Surg , vol.151 , pp. 362-363
    • Henry, M.L.1    Garner, W.L.2    Fabri, P.J.3
  • 27
    • 0026907375 scopus 로고
    • Sampling for arterial blood gas analysis. American association for respiratory care
    • Aarc clinical practice guideline
    • Aarc clinical practice guideline. Sampling for arterial blood gas analysis. American association for respiratory care. Respir Care 1992;37:913-7.
    • (1992) Respir Care , vol.37 , pp. 913-917
  • 28
    • 79955655884 scopus 로고    scopus 로고
    • Capnography/capnometry during mechanical ventilation
    • Walsh BK, Crotwell DN, Restrepo RD. Capnography/capnometry during mechanical ventilation: 2011. Respir Care 2011;56:503-9. http://dx.doi.org/10.4187/respcare.01175.
    • (2011) Respir Care , vol.2011 , Issue.56 , pp. 503-509
    • Walsh, B.K.1    Crotwell, D.N.2    Restrepo, R.D.3
  • 29
    • 0029073805 scopus 로고
    • International federation of clinical chemistry (ifcc). Scientific division. Committee on ph, blood gases and electrolytes. Approved ifcc recommendations on whole blood sampling, transport and storage for simultaneous determination of ph, blood gases and electrolytes
    • Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Maas AH, Müller-Plathe O, et al. International federation of clinical chemistry (ifcc). Scientific division. Committee on ph, blood gases and electrolytes. Approved ifcc recommendations on whole blood sampling, transport and storage for simultaneous determination of ph, blood gases and electrolytes. Eur J Clin Chem Clin Biochem 1995;33:247-53.
    • (1995) Eur J Clin Chem Clin Biochem , vol.33 , pp. 247-253
    • Burnett, R.W.1    Covington, A.K.2    Fogh-Andersen, N.3    Külpmann, W.R.4    Maas, A.H.5    Müller-Plathe, O.6
  • 30
    • 0023621515 scopus 로고
    • Biological variation of blood acid-base status: Consequences for analytical goal-setting and interpretation of results
    • Harding PJ, Fraser CG. Biological variation of blood acid-base status: Consequences for analytical goal-setting and interpretation of results. Clin Chem 1987;33:1416-8.
    • (1987) Clin Chem , vol.33 , pp. 1416-1418
    • Harding, P.J.1    Fraser, C.G.2
  • 32
    • 37549020378 scopus 로고    scopus 로고
    • Surviving sepsis campaign: International guidelines for management of severe sepsis and septic shock: 2008
    • Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, et al. Surviving sepsis campaign: International guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med 2008;36:296-327. http://dx.doi.org/10.1097/01.CCM.0000298158.12101.41.
    • (2008) Crit Care Med , vol.36 , pp. 296-327
    • Dellinger, R.P.1    Levy, M.M.2    Carlet, J.M.3    Bion, J.4    Parker, M.M.5    Jaeschke, R.6
  • 33
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001;345:1368-77. http://dx.doi.org/10.1056/NEJMoa010307,
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3    Ressler, J.4    Muzzin, A.5    Knoblich, B.6
  • 34
    • 58149341740 scopus 로고    scopus 로고
    • Capillary blood gases: To arterialize or not
    • Higgins C. Capillary blood gases: To arterialize or not. MLO Med Lab Obs 2008;40:42, 4-7.
    • (2008) MLO Med Lab Obs , vol.40 , Issue.42 , pp. 4-7
    • Higgins, C.1
  • 35
    • 84921514418 scopus 로고    scopus 로고
    • CLSI, approved standard - 6th edition.Vol, CLSI Document H04-A6, Wayne, PA, Clinical Laboratory Standards Institute
    • CLSI. Procedures and devices for the collection of diagnostic capillary blood specimens; approved standard - 6th edition.Vol. CLSI Document H04-A6. Wayne, PA: Clinical Laboratory Standards Institute, 2008.
    • (2008) Procedures and Devices For the Collection of Diagnostic Capillary Blood Specimens
  • 36
    • 0030937799 scopus 로고    scopus 로고
    • Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test
    • Smeenk FW, Janssen JD, Arends BJ, Harff GA, van den Bosch JA, Schönberger JP, Postmus PE. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test. Eur Respir J 1997;10:910-3.
    • (1997) Eur Respir J , vol.10 , pp. 910-913
    • Smeenk, F.W.1    Janssen, J.D.2    Arends, B.J.3    Harff, G.A.4    van den Bosch, J.A.5    Schönberger, J.P.6    Postmus, P.E.7
  • 37
    • 0032588732 scopus 로고    scopus 로고
    • Stability of po2, pco2, and ph in fresh blood samples stored in a plastic syringe with low heparin in relation to various blood-gas and hematological parameters
    • Beaulieu M, Lapointe Y, Vinet B. Stability of po2, pco2, and ph in fresh blood samples stored in a plastic syringe with low heparin in relation to various blood-gas and hematological parameters. Clin Biochem 1999;32:101-7. http://dx.doi.org/10.1016/S0009-9120(98)00098-8.
    • (1999) Clin Biochem , vol.32 , pp. 101-107
    • Beaulieu, M.1    Lapointe, Y.2    Vinet, B.3
  • 38
    • 84944297996 scopus 로고
    • Stability of po2, pco2 and ph in heparinized whole blood samples: Influence of storage temperature with regard to leukocyte count and syringe material
    • Schmidt C, Müller-Plathe O. Stability of po2, pco2 and ph in heparinized whole blood samples: Influence of storage temperature with regard to leukocyte count and syringe material. Eur J Clin Chem Clin Biochem 1992;30:767-73.
    • (1992) Eur J Clin Chem Clin Biochem , vol.30 , pp. 767-773
    • Schmidt, C.1    Müller-Plathe, O.2
  • 39
    • 33750895078 scopus 로고    scopus 로고
    • Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples
    • Knowles TP, Mullin RA, Hunter JA, Douce FH. Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples. Respir Care 2006;51:732-6.
    • (2006) Respir Care , vol.51 , pp. 732-736
    • Knowles, T.P.1    Mullin, R.A.2    Hunter, J.A.3    Douce, F.H.4
  • 40
    • 79951726288 scopus 로고    scopus 로고
    • Ionized calcium
    • Baird GS. Ionized calcium. Clin Chim Acta 2011;412:696-701. http://dx.doi.org/10.1016/j.cca.2011.01.004.
    • (2011) Clin Chim Acta , vol.412 , pp. 696-701
    • Baird, G.S.1
  • 41
    • 84857654702 scopus 로고    scopus 로고
    • Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis
    • Salvagno GL, Lippi G, Gelati M, Guidi GC. Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis. Clin Biochem 2012;45:372-3. http://dx.doi.org/10.1016/j.clinbiochem.2011.12.005.
    • (2012) Clin Biochem , vol.45 , pp. 372-373
    • Salvagno, G.L.1    Lippi, G.2    Gelati, M.3    Guidi, G.C.4
  • 42
    • 80052289159 scopus 로고    scopus 로고
    • Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories
    • Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci 2011;48:143-53. http://dx.doi.org/10.3109/10408363.2011.600228.
    • (2011) Crit Rev Clin Lab Sci , vol.48 , pp. 143-153
    • Lippi, G.1    Plebani, M.2    Di Somma, S.3    Cervellin, G.4
  • 43
    • 70249143582 scopus 로고    scopus 로고
    • Potential preanalytical errors in whole-blood analysis: Effect of syringe sample volume on blood gas, electrolyte and lactate values
    • Hedberg P, Majava A, Kiviluoma K, Ohtonen P. Potential preanalytical errors in whole-blood analysis: Effect of syringe sample volume on blood gas, electrolyte and lactate values. Scand J Clin Lab Invest 2009;69:585-91. http://dx.doi.org/10.1080/00365510902878716.
    • (2009) Scand J Clin Lab Invest , vol.69 , pp. 585-591
    • Hedberg, P.1    Majava, A.2    Kiviluoma, K.3    Ohtonen, P.4
  • 44
    • 84865370132 scopus 로고    scopus 로고
    • The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin
    • Küme T, Sişman AR, Solak A, Tuǧlu B, Cinkooǧlu B, Coker C. The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin. Biochem Med (Zagreb) 2012;22:189-201.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 189-201
    • Küme, T.1    Sişman, A.R.2    Solak, A.3    Tuǧlu, B.4    Cinkooǧlu, B.5    Coker, C.6
  • 45
    • 72649094040 scopus 로고    scopus 로고
    • Impact of blood collection devices on clinical chemistry assays
    • Bowen RA, Hortin GL, Csako G, Otañez OH, Remaley AT. Impact of blood collection devices on clinical chemistry assays. Clin Biochem 2010;43:4-25. http://dx.doi.org/10.1016/j.clinbiochem.2009.10.001.
    • (2010) Clin Biochem , vol.43 , pp. 4-25
    • Bowen, R.A.1    Hortin, G.L.2    Csako, G.3    Otañez, O.H.4    Remaley, A.T.5
  • 46
    • 80051717778 scopus 로고    scopus 로고
    • Agreement between paired blood gas values in samples transported either by a pneumatic system or by human courier
    • Victor Peter J, Patole S, Fleming JJ, Selvakumar R, Graham PL. Agreement between paired blood gas values in samples transported either by a pneumatic system or by human courier. Clin Chem Lab Med 2011;49:1303-9. http://dx.doi.org/10.1515/cclm.2011.611.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 1303-1309
    • Victor Peter, J.1    Patole, S.2    Fleming, J.J.3    Selvakumar, R.4    Graham, P.L.5
  • 47
    • 80053420455 scopus 로고    scopus 로고
    • Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems
    • Streichert T, Otto B, Schnabel C, Nordholt G, Haddad M, Maric M, et al. Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems. Clin Chem 2011;57:1390-7. http://dx.doi.org/10.1373/clinchem.2011.167932.
    • (2011) Clin Chem , vol.57 , pp. 1390-1397
    • Streichert, T.1    Otto, B.2    Schnabel, C.3    Nordholt, G.4    Haddad, M.5    Maric, M.6
  • 48
    • 0030035698 scopus 로고    scopus 로고
    • Pneumatic transport exacerbates interference of room air contamination in blood gas samples
    • Astles JR, Lubarsky D, Loun B, Sedor FA, Toffaletti JG. Pneumatic transport exacerbates interference of room air contamination in blood gas samples. Arch Pathol Lab Med 1996;120:642-7.
    • (1996) Arch Pathol Lab Med , vol.120 , pp. 642-647
    • Astles, J.R.1    Lubarsky, D.2    Loun, B.3    Sedor, F.A.4    Toffaletti, J.G.5
  • 49
    • 0036164355 scopus 로고    scopus 로고
    • Changes in blood gas samples produced by a pneumatic tube system
    • Collinson PO, John CM, Gaze DC, Ferrigan LF, Cramp DG. Changes in blood gas samples produced by a pneumatic tube system. J Clin Pathol 2002;55:105-7. http://dx.doi.org/10.1136/jcp.55.2.105.
    • (2002) J Clin Pathol , vol.55 , pp. 105-107
    • Collinson, P.O.1    John, C.M.2    Gaze, D.C.3    Ferrigan, L.F.4    Cramp, D.G.5
  • 50
    • 0042413652 scopus 로고    scopus 로고
    • Effects of air bubbles and tube transportation on blood oxygen tension in arterial blood gas analysis
    • Lu JY, Kao JT, Chien TI, Lee TF, Tsai KS. Effects of air bubbles and tube transportation on blood oxygen tension in arterial blood gas analysis. J Formos Med Assoc 2003;102:246-9.
    • (2003) J Formos Med Assoc , vol.102 , pp. 246-249
    • Lu, J.Y.1    Kao, J.T.2    Chien, T.I.3    Lee, T.F.4    Tsai, K.S.5
  • 51
    • 0032741475 scopus 로고    scopus 로고
    • Arterial blood gas reference values for sea level and an altitude of 1,400 meters
    • Crapo RO, Jensen RL, Hegewald M, Tashkin DP. Arterial blood gas reference values for sea level and an altitude of 1,400 meters. Am J Respir Crit Care Med 1999;160:1525-31.
    • (1999) Am J Respir Crit Care Med , vol.160 , pp. 1525-1531
    • Crapo, R.O.1    Jensen, R.L.2    Hegewald, M.3    Tashkin, D.P.4
  • 52
    • 84862181290 scopus 로고    scopus 로고
    • Prehospital airway management: High tech meets trauma: An air medical perspective
    • Bauer K. Prehospital airway management: High tech meets trauma: An air medical perspective. Crit Care Nurs Q 2012;35:281-91.
    • (2012) Crit Care Nurs Q , vol.35 , pp. 281-291
    • Bauer, K.1
  • 53
    • 0020629384 scopus 로고
    • Temperature correction of blood-gas and ph measurements
    • Ashwood ER, Kost G, Kenny M. Temperature correction of blood-gas and ph measurements. Clin Chem 1983;29:1877-85.
    • (1983) Clin Chem , vol.29 , pp. 1877-1885
    • Ashwood, E.R.1    Kost, G.2    Kenny, M.3
  • 54
    • 0038681701 scopus 로고    scopus 로고
    • Spurious hypoxaemia in a patient with leukaemia and extreme leucocytosis
    • Khoo SM, Lee KH, Notley M. Spurious hypoxaemia in a patient with leukaemia and extreme leucocytosis. Singapore Med J 2003;44:208-10.
    • (2003) Singapore Med J , vol.44 , pp. 208-210
    • Khoo, S.M.1    Lee, K.H.2    Notley, M.3
  • 55
    • 40649089109 scopus 로고    scopus 로고
    • Platelet larceny: Spurious hypoxaemia due to extreme thrombocytosis
    • Mehta A, Lichtin AE, Vigg A, Parambil JG. Platelet larceny: Spurious hypoxaemia due to extreme thrombocytosis. Eur Respir J 2008;31:469-72. http://dx.doi.org/10.1183/09031936.00039607.
    • (2008) Eur Respir J , vol.31 , pp. 469-472
    • Mehta, A.1    Lichtin, A.E.2    Vigg, A.3    Parambil, J.G.4
  • 56
    • 23844491137 scopus 로고    scopus 로고
    • Spurious hypoxemia
    • Lele AV, Mirski MA, Stevens RD. Spurious hypoxemia. Crit Care Med 2005;33:1854-6. http://dx.doi.org/10.1097/01.CCM.0000171838.41529.22.
    • (2005) Crit Care Med , vol.33 , pp. 1854-1856
    • Lele, A.V.1    Mirski, M.A.2    Stevens, R.D.3
  • 57
    • 77958564044 scopus 로고    scopus 로고
    • Unexpectedly low pulse oximetry measurements associated with variant hemoglobins: A systematic review
    • Verhovsek M, Henderson MP, Cox G, Luo HY, Steinberg MH, Chui DH. Unexpectedly low pulse oximetry measurements associated with variant hemoglobins: A systematic review. Am J Hematol 2010;85:882-5. http://dx.doi.org/10.1002/ajh.21810.
    • (2010) Am J Hematol , vol.85 , pp. 882-885
    • Verhovsek, M.1    Henderson, M.P.2    Cox, G.3    Luo, H.Y.4    Steinberg, M.H.5    Chui, D.H.6
  • 58
    • 0018638866 scopus 로고
    • Interference of anesthetic gases at oxygen sensors
    • Eberhard P, Mindt W. Interference of anesthetic gases at oxygen sensors. Birth Defects Orig Artic Ser 1979;15:65-74.
    • (1979) Birth Defects Orig Artic Ser , vol.15 , pp. 65-74
    • Eberhard, P.1    Mindt, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.