-
1
-
-
33847000181
-
Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers
-
Kratz A, Salem RO, van Cott EM. Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers. Arch Pathol Lab Med 2007;131:293-6.
-
(2007)
Arch Pathol Lab Med
, vol.131
, pp. 293-296
-
-
Kratz, A.1
Salem, R.O.2
Van Cott, E.M.3
-
2
-
-
2442429634
-
Pneumatic tube system induced haemolysis: Assessing sample type susceptibility to haemolysis
-
DOI 10.1258/000456304323019631
-
Sodi R, Darn SM, Stott A. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis. Ann Clin Biochem 2004;41:237-40. (Pubitemid 38623152)
-
(2004)
Annals of Clinical Biochemistry
, vol.41
, Issue.3
, pp. 237-240
-
-
Sodi, R.1
Darn, S.M.2
Stott, A.3
-
3
-
-
0015167166
-
Evaluation of pneumatic-tube system for delivery of blood specimens
-
Steige H, Jones JD. Evaluation of pneumatic-tube system for delivery of blood specimens. Clin Chem 1971;17:1160-4.
-
(1971)
Clin Chem
, vol.17
, pp. 1160-1164
-
-
Steige, H.1
Jones, J.D.2
-
4
-
-
0026605279
-
Evaluation of a softhandling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time
-
Keshgegian AA, Bull GE. Evaluation of a softhandling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time. Am J Clin Pathol 1992;97:535-40.
-
(1992)
Am J Clin Pathol
, vol.97
, pp. 535-540
-
-
Keshgegian, A.A.1
Bull, G.E.2
-
5
-
-
0036164355
-
Changes in blood gas samples produced by a pneumatic tube system
-
Collinson PO, John CM, Gaze DC, Ferrigan LF, Cramp DG. Changes in blood gas samples produced by a pneumatic tube system. J Clin Pathol 2002;55:105-7. (Pubitemid 34123909)
-
(2002)
Journal of Clinical Pathology
, vol.55
, Issue.2
, pp. 105-107
-
-
Collinson, P.O.1
John, C.M.2
Gaze, D.C.3
Ferrigan, L.F.4
Cramp, D.G.5
-
7
-
-
0019253029
-
A computer directed pneumatic tube system: Its effects on specimens
-
DOI 10.1016/S0009-9120(80)80005-1
-
Pragay DA, Fan P, Brinkley S, Chilcote ME. A computer directed pneumatic tube system: its effects on specimens. Clin Biochem 1980;13:259-61. (Pubitemid 11036746)
-
(1980)
Clinical Biochemistry
, vol.13
, Issue.6
, pp. 259-261
-
-
Pragay, D.A.1
Fan, P.2
Brinkley, S.3
Chilcote, M.E.4
-
8
-
-
67650732426
-
An episode of increased hemolysis due to a defective pneumatic air tube delivery system
-
Ellis G. An episode of increased hemolysis due to a defective pneumatic air tube delivery system. Clin Biochem 2009;42:1265-9.
-
(2009)
Clin Biochem
, vol.42
, pp. 1265-1269
-
-
Ellis, G.1
-
9
-
-
69549121561
-
Pneumatic tube "pseudo tumor lysis syndrome" in chronic lymphocytic leukemia
-
Chawla NR, Shapiro J, Sham RL. Pneumatic tube "pseudo tumor lysis syndrome" in chronic lymphocytic leukemia. Am J Hematol 2009;84:613-4.
-
(2009)
Am J Hematol
, vol.84
, pp. 613-614
-
-
Chawla, N.R.1
Shapiro, J.2
Sham, R.L.3
-
10
-
-
33645284139
-
Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality
-
DOI 10.1016/j.jen.2005.11.013, PII S0099176705007269
-
Fernandes CM, Worster A, Eva K, Hill S, McCallum C. Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality. J Emerg Nurs 2006;32:139-43. (Pubitemid 43467713)
-
(2006)
Journal of Emergency Nursing
, vol.32
, Issue.2
, pp. 139-143
-
-
Fernandes, C.M.B.1
Worster, A.2
Eva, K.3
Hill, S.4
McCallum, C.5
-
11
-
-
33750332586
-
Transport of blood gas samples: Is the pneumatic tube system safe?
-
Zanner R, Moser N, Blobner M, Luppa PB. [Transport of blood gas samples: is the pneumatic tube system safe?]. Anaesthesist 2006;55:1099-104.
-
(2006)
Anaesthesist
, vol.55
, pp. 1099-1104
-
-
Zanner, R.1
Moser, N.2
Blobner, M.3
Luppa, P.B.4
-
12
-
-
53849144983
-
Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
-
Wallin O, Soderberg J, Grankvist K, Jonsson PA, Hultdin J. Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation. Clin Chem Lab Med 2008;46:1443-9.
-
(2008)
Clin Chem Lab Med
, vol.46
, pp. 1443-1449
-
-
Wallin, O.1
Soderberg, J.2
Grankvist, K.3
Jonsson, P.A.4
Hultdin, J.5
-
14
-
-
18744412658
-
Mechanical fragility calibration of red blood cells
-
DOI 10.1097/01.MAT.0000161940.30190.6D
-
Gu L, Smith WA, Chatzimavroudis GP. Mechanical fragility calibration of red blood cells. ASAIO J 2005;51:194-201. (Pubitemid 40677126)
-
(2005)
ASAIO Journal
, vol.51
, Issue.3
, pp. 194-201
-
-
Gu, L.1
Smith, W.A.2
Chatzimavroudis, G.P.3
-
15
-
-
33846918023
-
Mechanical hemolysis in blood flow: User-independent predictions with the solution of a partial differential equation
-
Lacasse D, Garon A, Pelletier D. Mechanical hemolysis in blood flow: user-independent predictions with the solution of a partial differential equation. Comput Methods Biomech Biomed Engin 2007;10:1-12.
-
(2007)
Comput Methods Biomech Biomed Engin
, vol.10
, pp. 1-12
-
-
Lacasse, D.1
Garon, A.2
Pelletier, D.3
-
17
-
-
45749145482
-
Pseudohyperkalemia in chronic lymphocytic leukemia
-
Ruddy KJ, Wu D, Brown JR. Pseudohyperkalemia in chronic lymphocytic leukemia. J Clin Oncol 2008;26:2781-2.
-
(2008)
J Clin Oncol
, vol.26
, pp. 2781-2782
-
-
Ruddy, K.J.1
Wu, D.2
Brown, J.R.3
-
18
-
-
0030115293
-
Hemolytic anemias due to disorders of red cell membrane skeleton
-
Bossi D, Russo M. Hemolytic anemias due to disorders of red cell membrane skeleton. Mol Aspects Med 1996;17:171-88.
-
(1996)
Mol Aspects Med
, vol.17
, pp. 171-188
-
-
Bossi, D.1
Russo, M.2
|