-
1
-
-
0037126341
-
Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer
-
Fisher B, Anderson S, Bryant J, Margolese RG, Deutsch M, Fisher ER, Jeong JH, Wolmark N,. Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer. N Engl J Med 2002; 347: 1233-1241.
-
(2002)
N Engl J Med
, vol.347
, pp. 1233-1241
-
-
Fisher, B.1
Anderson, S.2
Bryant, J.3
Margolese, R.G.4
Deutsch, M.5
Fisher, E.R.6
Jeong, J.H.7
Wolmark, N.8
-
2
-
-
79951942913
-
Long-term clinical and cosmetic outcomes after breast conservation treatment for women with early-stage breast carcinoma according to the type of breast boost
-
Hill-Kayser CE, Chacko D, Hwang WT, Vapiwala N, Solin LJ,. Long-term clinical and cosmetic outcomes after breast conservation treatment for women with early-stage breast carcinoma according to the type of breast boost. Int J Radiat Oncol Biol Phys 2011; 79: 1048-1054.
-
(2011)
Int J Radiat Oncol Biol Phys
, vol.79
, pp. 1048-1054
-
-
Hill-Kayser, C.E.1
Chacko, D.2
Hwang, W.T.3
Vapiwala, N.4
Solin, L.J.5
-
3
-
-
0028459118
-
Interventional use of magnetic resonance imaging
-
Jolesz FA, Blumenfeld SM,. Interventional use of magnetic resonance imaging. Magn Reson Q 1994; 10: 85-96.
-
(1994)
Magn Reson Q
, vol.10
, pp. 85-96
-
-
Jolesz, F.A.1
Blumenfeld, S.M.2
-
5
-
-
34247643557
-
The evolving non-surgical ablation of breast cancer: MR guided focused ultrasound (MRgFUS)
-
Furusawa H, Namba K, Nakahara H, Tanaka C, Yasuda Y, Hirabara E, Imahariyama M, Komaki K,. The evolving non-surgical ablation of breast cancer: MR guided focused ultrasound (MRgFUS). Breast Cancer 2007; 14: 55-58.
-
(2007)
Breast Cancer
, vol.14
, pp. 55-58
-
-
Furusawa, H.1
Namba, K.2
Nakahara, H.3
Tanaka, C.4
Yasuda, Y.5
Hirabara, E.6
Imahariyama, M.7
Komaki, K.8
-
6
-
-
34547940835
-
"wide local ablation" of localized breast cancer using high intensity focused ultrasound
-
Wu F, Wang ZB, Cao YD, Zhu XQ, Zhu H, Chen WZ, Zou JZ,. "Wide local ablation" of localized breast cancer using high intensity focused ultrasound. J Surg Oncol 2007; 96: 130-136.
-
(2007)
J Surg Oncol
, vol.96
, pp. 130-136
-
-
Wu, F.1
Wang, Z.B.2
Cao, Y.D.3
Zhu, X.Q.4
Zhu, H.5
Chen, W.Z.6
Zou, J.Z.7
-
7
-
-
33745221857
-
Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
-
Furusawa H, Namba K, Thomsen S, Akiyama F, Bendet A, Tanaka C, Yasuda Y, Nakahara H,. Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness. J Am Coll Surg 2006; 203: 54-63.
-
(2006)
J Am Coll Surg
, vol.203
, pp. 54-63
-
-
Furusawa, H.1
Namba, K.2
Thomsen, S.3
Akiyama, F.4
Bendet, A.5
Tanaka, C.6
Yasuda, Y.7
Nakahara, H.8
-
8
-
-
0345688804
-
MR imaging-guided focused ultrasound surgery of breast cancer: Correlation of dynamic contrast-enhanced MRI with histopathologic findings
-
Gianfelice D, Khiat A, Amara M, Belblidia A, Boulanger Y,. MR imaging-guided focused ultrasound surgery of breast cancer: correlation of dynamic contrast-enhanced MRI with histopathologic findings. Breast Cancer Res Treat 2003; 82: 93-101.
-
(2003)
Breast Cancer Res Treat
, vol.82
, pp. 93-101
-
-
Gianfelice, D.1
Khiat, A.2
Amara, M.3
Belblidia, A.4
Boulanger, Y.5
-
9
-
-
0035576808
-
A new noninvasive approach in breast cancer therapy using magnetic resonance imaging-guided focused ultrasound surgery
-
Huber PE, Jenne JW, Rastert R, Simiantonakis I, Sinn HP, Strittmatter HJ, von Fournier D, Wannenmacher MF, Debus J,. A new noninvasive approach in breast cancer therapy using magnetic resonance imaging-guided focused ultrasound surgery. Cancer Res 2001; 61: 8441-8447.
-
(2001)
Cancer Res
, vol.61
, pp. 8441-8447
-
-
Huber, P.E.1
Jenne, J.W.2
Rastert, R.3
Simiantonakis, I.4
Sinn, H.P.5
Strittmatter, H.J.6
Von Fournier, D.7
Wannenmacher, M.F.8
Debus, J.9
-
10
-
-
79952433984
-
High intensity focused ultrasound ablation: A new therapeutic option for solid tumors
-
Orsi F, Arnone P, Chen W, Zhang L,. High intensity focused ultrasound ablation: a new therapeutic option for solid tumors. J Cancer Res Ther 2010; 6: 414-420.
-
(2010)
J Cancer Res Ther
, vol.6
, pp. 414-420
-
-
Orsi, F.1
Arnone, P.2
Chen, W.3
Zhang, L.4
-
11
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
12
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962.
-
(1999)
Magn Reson Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
13
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A,. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
14
-
-
69449091437
-
96-Channel receive-only head coil for 3 Tesla: Design optimization and evaluation
-
Wiggins GC, Polimeni JR, Potthast A, Schmitt M, Alagappan V, Wald LL,. 96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation. Magn Reson Med 2009; 62: 754-762.
-
(2009)
Magn Reson Med
, vol.62
, pp. 754-762
-
-
Wiggins, G.C.1
Polimeni, J.R.2
Potthast, A.3
Schmitt, M.4
Alagappan, V.5
Wald, L.L.6
-
15
-
-
33745685594
-
32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
-
Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL,. 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006; 56: 216-223.
-
(2006)
Magn Reson Med
, vol.56
, pp. 216-223
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
16
-
-
21244493990
-
Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging
-
Wiggins GC, Potthast A, Triantafyllou C, Wiggins CJ, Wald LL,. Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging. Magn Reson Med 2005; 54: 235-240.
-
(2005)
Magn Reson Med
, vol.54
, pp. 235-240
-
-
Wiggins, G.C.1
Potthast, A.2
Triantafyllou, C.3
Wiggins, C.J.4
Wald, L.L.5
-
17
-
-
73349141558
-
An eight-channel phased array RF coil for spine MR imaging at 7 T
-
Kraff O, Bitz AK, Kruszona S, Orzada S, Schaefer LC, Theysohn JM, Maderwald S, Ladd ME, Quick HH,. An eight-channel phased array RF coil for spine MR imaging at 7 T. Invest Radiol 2009; 44: 734-740.
-
(2009)
Invest Radiol
, vol.44
, pp. 734-740
-
-
Kraff, O.1
Bitz, A.K.2
Kruszona, S.3
Orzada, S.4
Schaefer, L.C.5
Theysohn, J.M.6
Maderwald, S.7
Ladd, M.E.8
Quick, H.H.9
-
18
-
-
0029068286
-
Phased-array surface coil MR of the orbits and optic nerves
-
Breslau J, Dalley RW, Tsuruda JS, Hayes CE, Maravilla KR,. Phased-array surface coil MR of the orbits and optic nerves. AJNR Am J Neuroradiol 1995; 16: 1247-1251.
-
(1995)
AJNR Am J Neuroradiol
, vol.16
, pp. 1247-1251
-
-
Breslau, J.1
Dalley, R.W.2
Tsuruda, J.S.3
Hayes, C.E.4
Maravilla, K.R.5
-
20
-
-
0031425055
-
Theory and application of array coils in MR spectroscopy
-
Wright SM, Wald LL,. Theory and application of array coils in MR spectroscopy. NMR Biomed 1997; 10: 394-410.
-
(1997)
NMR Biomed
, vol.10
, pp. 394-410
-
-
Wright, S.M.1
Wald, L.L.2
-
21
-
-
0033818660
-
Magnetic resonance temperature imaging for guidance of thermotherapy
-
Quesson B, de Zwart JA, Moonen CT,. Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 2000; 12: 525-533.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 525-533
-
-
Quesson, B.1
De Zwart, J.A.2
Moonen, C.T.3
-
22
-
-
84857828621
-
Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array
-
Payne A, Merrill R, Minalga E, Vyas U, de Bever J, Todd N, Hadley R, Dumont E, Neumayer L, Christensen D, Roemer R, Parker D,. Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array. Med Phys 2012; 39: 1552-1560.
-
(2012)
Med Phys
, vol.39
, pp. 1552-1560
-
-
Payne, A.1
Merrill, R.2
Minalga, E.3
Vyas, U.4
De Bever, J.5
Todd, N.6
Hadley, R.7
Dumont, E.8
Neumayer, L.9
Christensen, D.10
Roemer, R.11
Parker, D.12
-
23
-
-
84872836351
-
Design and Initial Evaluation of a Breast-specific MRgFUS Treatment System
-
Washington, D.C., USA
-
Payne A, Merrill R, Minalga E, Hadley R, Vyas U, Bever Jd, Dumont E, Roemer R, Christensen D, Neumayer L, Parker D,. Design and Initial Evaluation of a Breast-specific MRgFUS Treatment System. In: MR-guided Focused Ultrasound, 2nd International Symposium. Washington, D.C., USA; 2010.
-
(2010)
MR-guided Focused Ultrasound, 2nd International Symposium
-
-
Payne, A.1
Merrill, R.2
Minalga, E.3
Hadley, R.4
Vyas, U.5
Bever, J.6
Dumont, E.7
Roemer, R.8
Christensen, D.9
Neumayer, L.10
Parker, D.11
-
24
-
-
0001301865
-
Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopy
-
Edelstein WA, Hardy C, Mueller O,. Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopy. J Magn Reson 1986; 67: 156-161.
-
(1986)
J Magn Reson
, vol.67
, pp. 156-161
-
-
Edelstein, W.A.1
Hardy, C.2
Mueller, O.3
-
25
-
-
0036298536
-
Coupling and decoupling theory and its application to the MRI phased array
-
Lee RF, Giaquinto RO, Hardy CJ,. Coupling and decoupling theory and its application to the MRI phased array. Magn Reson Med 2002; 48: 203-213.
-
(2002)
Magn Reson Med
, vol.48
, pp. 203-213
-
-
Lee, R.F.1
Giaquinto, R.O.2
Hardy, C.J.3
-
26
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM,. The NMR phased array. Magn Reson Med 1990; 16: 192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
27
-
-
0026438141
-
Acceptance testing of magnetic resonance imaging systems: Report of AAPM Nuclear Magnetic Resonance Task Group No. 6
-
Och JG, Clarke GD, Sobol WT, Rosen CW, Mun SK,. Acceptance testing of magnetic resonance imaging systems: report of AAPM Nuclear Magnetic Resonance Task Group No. 6. Med Phys 1992; 19: 217-229.
-
(1992)
Med Phys
, vol.19
, pp. 217-229
-
-
Och, J.G.1
Clarke, G.D.2
Sobol, W.T.3
Rosen, C.W.4
Mun, S.K.5
-
28
-
-
0029142688
-
Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils
-
Wang J, Reykowski A, Dickas J,. Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils. IEEE Trans Biomed Eng 1995; 42: 908-917.
-
(1995)
IEEE Trans Biomed Eng
, vol.42
, pp. 908-917
-
-
Wang, J.1
Reykowski, A.2
Dickas, J.3
-
29
-
-
27644527486
-
Image reconstruction in SNR units: A general method for SNR measurement
-
Kellman P, McVeigh ER,. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 2005; 54: 1439-1447.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1439-1447
-
-
Kellman, P.1
McVeigh, E.R.2
-
30
-
-
0030726766
-
Signal-to-noise measurements in magnitude images from NMR phased arrays
-
Constantinides CD, Atalar E, McVeigh ER,. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 1997; 38: 852-857.
-
(1997)
Magn Reson Med
, vol.38
, pp. 852-857
-
-
Constantinides, C.D.1
Atalar, E.2
McVeigh, E.R.3
-
31
-
-
79251540606
-
The effects of spatial sampling choices on MR temperature measurements
-
Todd N, Vyas U, de Bever J, Payne A, Parker DL,. The effects of spatial sampling choices on MR temperature measurements. Magn Reson Med 2011; 65: 515-521.
-
(2011)
Magn Reson Med
, vol.65
, pp. 515-521
-
-
Todd, N.1
Vyas, U.2
De Bever, J.3
Payne, A.4
Parker, D.L.5
-
32
-
-
85027221761
-
Large aperture transducer designed for MR-HIFU treatment of breast tumors
-
Montreal, Canada
-
Mougenot C, Kohler M, Tillander M, Moonen C, Barteks W, Ehnholm G,. Large aperture transducer designed for MR-HIFU treatment of breast tumors. In: Proceedings of the 19th Annual Meeting of ISMRM. Montreal, Canada; 2011. p 1727.
-
(2011)
Proceedings of the 19th Annual Meeting of ISMRM
, pp. 1727
-
-
Mougenot, C.1
Kohler, M.2
Tillander, M.3
Moonen, C.4
Barteks, W.5
Ehnholm, G.6
|