메뉴 건너뛰기




Volumn 39, Issue 3, 2012, Pages 1552-1560

Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array

Author keywords

breast; high intensity focused ultrasound; MRI

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; CYLINDERS (SHAPES); LOCATION; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; PATIENT TREATMENT; PHANTOMS; TEMPERATURE MEASUREMENT; TRANSDUCERS; TUMORS; ULTRASONIC TRANSDUCERS;

EID: 84857828621     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3685576     Document Type: Article
Times cited : (41)

References (35)
  • 1
    • 0034040940 scopus 로고    scopus 로고
    • Saline-enhanced radiofrequency ablation of breast tissue: An in vitro feasibility study
    • 10.1097/00004424-200003000-00001
    • T. Bohm, I. Hilger, W. Muller, J. R. Reichenbach, M. Fleck, and W. A. Kaiser, Saline-enhanced radiofrequency ablation of breast tissue: An in vitro feasibility study., Invest. Radiol. 35 (3), 149-157 (2000). 10.1097/00004424- 200003000-00001
    • (2000) Invest. Radiol. , vol.35 , Issue.3 , pp. 149-157
    • Bohm, T.1    Hilger, I.2    Muller, W.3    Reichenbach, J.R.4    Fleck, M.5    Kaiser, W.A.6
  • 2
    • 0032850577 scopus 로고    scopus 로고
    • Radiofrequency ablation of breast cancer: First report of an emerging technology
    • 10.1001/archsurg.134.10.1064
    • S. S. Jeffrey, R. L. Birdwell, D. M. Ikeda, B. L. Daniel, K. W. Nowels, F. M. Dirbas, and S. M. Griffey, Radiofrequency ablation of breast cancer: first report of an emerging technology., Arch. Surg. 134 (10), 1064-1068 (1999). 10.1001/archsurg.134.10.1064
    • (1999) Arch. Surg. , vol.134 , Issue.10 , pp. 1064-1068
    • Jeffrey, S.S.1    Birdwell, R.L.2    Ikeda, D.M.3    Daniel, B.L.4    Nowels, K.W.5    Dirbas, F.M.6    Griffey, S.M.7
  • 3
    • 0034052861 scopus 로고    scopus 로고
    • Interventional MRI of the breast: Minimally invasive therapy
    • 10.1007/s003300050007
    • M. A. Hall-Craggs, Interventional MRI of the breast: Minimally invasive therapy., Eur. Radiol. 10 (1), 59-62 (2000). 10.1007/s003300050007
    • (2000) Eur. Radiol. , vol.10 , Issue.1 , pp. 59-62
    • Hall-Craggs, M.A.1
  • 10
    • 0037612192 scopus 로고    scopus 로고
    • MR imaging-guided focused US ablation of breast cancer: Histopathologic assessment of effectiveness-Initial experience
    • 10.1148/radiol.2281012163
    • D. Gianfelice, A. Khiat, M. Amara, A. Belblidia, and Y. Boulanger, MR imaging-guided focused US ablation of breast cancer: Histopathologic assessment of effectiveness-Initial experience., Radiology 227 (3), 849-855 (2003). 10.1148/radiol.2281012163
    • (2003) Radiology , vol.227 , Issue.3 , pp. 849-855
    • Gianfelice, D.1    Khiat, A.2    Amara, M.3    Belblidia, A.4    Boulanger, Y.5
  • 11
    • 33746010225 scopus 로고    scopus 로고
    • Heat fixation of cancer cells ablated with high-intensity-focused ultrasound in patients with breast cancer
    • 10.1016/j.amjsurg.2006.03.014
    • F. Wu, Z. B. Wang, Y. D. Cao, Z. L. Xu, Q. Zhou, H. Zhu, and W. Z. Chen, Heat fixation of cancer cells ablated with high-intensity-focused ultrasound in patients with breast cancer., Am. J. Surg. 192 (2), 179-184 (2006). 10.1016/j.amjsurg.2006.03.014
    • (2006) Am. J. Surg. , vol.192 , Issue.2 , pp. 179-184
    • Wu, F.1    Wang, Z.B.2    Cao, Y.D.3    Xu, Z.L.4    Zhou, Q.5    Zhu, H.6    Chen, W.Z.7
  • 12
    • 34247643557 scopus 로고    scopus 로고
    • The evolving non-surgical ablation of breast cancer: MR guided focused ultrasound (MRgFUS)
    • 10.2325/jbcs.14.55
    • H. Furusawa, K. Namba, H. Nakahara, C. Tanaka, Y. Yasuda, E. Hirabara, M. Imahariyama, and K. Komaki, The evolving non-surgical ablation of breast cancer: MR guided focused ultrasound (MRgFUS)., Breast Cancer 14 (1), 55-58 (2007). 10.2325/jbcs.14.55
    • (2007) Breast Cancer , vol.14 , Issue.1 , pp. 55-58
    • Furusawa, H.1    Namba, K.2    Nakahara, H.3    Tanaka, C.4    Yasuda, Y.5    Hirabara, E.6    Imahariyama, M.7    Komaki, K.8
  • 13
    • 33745221857 scopus 로고    scopus 로고
    • Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
    • 10.1016/j.jamcollsurg.2006.04.002
    • H. Furusawa, K. Namba, S. Thomsen, F. Akiyama, A. Bendet, C. Tanaka, Y. Yasuda, and H. Nakahara, Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness., J. Am. Coll. Surg. 203 (1), 54-63 (2006). 10.1016/j.jamcollsurg.2006.04.002
    • (2006) J. Am. Coll. Surg. , vol.203 , Issue.1 , pp. 54-63
    • Furusawa, H.1    Namba, K.2    Thomsen, S.3    Akiyama, F.4    Bendet, A.5    Tanaka, C.6    Yasuda, Y.7    Nakahara, H.8
  • 14
    • 34547940835 scopus 로고    scopus 로고
    • Wide local ablation of localized breast cancer using high intensity focused ultrasound
    • 10.1002/(ISSN)1096-9098
    • F. Wu, Z. B. Wang, Y. D. Cao, X. Q. Zhu, H. Zhu, W. Z. Chen, and J. Z. Zou, Wide local ablation of localized breast cancer using high intensity focused ultrasound., J. Surg. Oncol. 96 (2), 130-136 (2007). 10.1002/(ISSN)1096-9098
    • (2007) J. Surg. Oncol. , vol.96 , Issue.2 , pp. 130-136
    • Wu, F.1    Wang, Z.B.2    Cao, Y.D.3    Zhu, X.Q.4    Zhu, H.5    Chen, W.Z.6    Zou, J.Z.7
  • 15
    • 11144354898 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: An overview
    • 10.1016/j.ultsonch.2004.01.011
    • F. Wu, Z. B. Wang, W. Z. Chen, W. Wang, Y. Gui, M. Zhang, G. Zheng, Y. Zhou, G. Xu, M. Li, C. Zhang, H. Ye, and R. Feng, Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: An overview., Ultrason. Sonochem. 11 (3-4), 149-154 (2004). 10.1016/j.ultsonch.2004.01.011
    • (2004) Ultrason. Sonochem. , vol.11 , Issue.34 , pp. 149-154
    • Wu, F.1    Wang, Z.B.2    Chen, W.Z.3    Wang, W.4    Gui, Y.5    Zhang, M.6    Zheng, G.7    Zhou, Y.8    Xu, G.9    Li, M.10    Zhang, C.11    Ye, H.12    Feng, R.13
  • 16
    • 21044451307 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound treatment for patients with breast cancer
    • 10.1007/s10549-004-5778-7
    • F. Wu, Z. B. Wang, H. Zhu, W. Z. Chen, J. Z. Zou, J. Bai, K. Q. Li, C. B. Jin, F. L. Xie, and H. B. Su, Extracorporeal high intensity focused ultrasound treatment for patients with breast cancer., Breast Cancer Res. Treat. 92 (1), 51-60 (2005). 10.1007/s10549-004-5778-7
    • (2005) Breast Cancer Res. Treat. , vol.92 , Issue.1 , pp. 51-60
    • Wu, F.1    Wang, Z.B.2    Zhu, H.3    Chen, W.Z.4    Zou, J.Z.5    Bai, J.6    Li, K.Q.7    Jin, C.B.8    Xie, F.L.9    Su, H.B.10
  • 17
    • 0142026382 scopus 로고    scopus 로고
    • Feasibility of magnetic resonance imaging-guided focused ultrasound surgery as an adjunct to tamoxifen therapy in high-risk surgical patients with breast carcinoma
    • 10.1097/01.RVI.0000092900.73329.A2
    • D. Gianfelice, A. Khiat, Y. Boulanger, M. Amara, and A. Belblidia, Feasibility of magnetic resonance imaging-guided focused ultrasound surgery as an adjunct to tamoxifen therapy in high-risk surgical patients with breast carcinoma., J. Vasc. Interv. Radiol. 14 (10), 1275-1282 (2003). 10.1097/01.RVI.0000092900.73329.A2
    • (2003) J. Vasc. Interv. Radiol. , vol.14 , Issue.10 , pp. 1275-1282
    • Gianfelice, D.1    Khiat, A.2    Boulanger, Y.3    Amara, M.4    Belblidia, A.5
  • 18
    • 34547102487 scopus 로고    scopus 로고
    • Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: A preliminary numerical study
    • 10.1088/0031-9155/52/15/015
    • C. S. Ho, K. C. Ju, T. Y. Cheng, Y. Y. Chen, and W. L. Lin, Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: A preliminary numerical study., Phys. Med. Biol. 52 (15), 4585-4599 (2007). 10.1088/0031-9155/52/15/015
    • (2007) Phys. Med. Biol. , vol.52 , Issue.15 , pp. 4585-4599
    • Ho, C.S.1    Ju, K.C.2    Cheng, T.Y.3    Chen, Y.Y.4    Lin, W.L.5
  • 19
    • 31344466799 scopus 로고    scopus 로고
    • Investigation of a scanned cylindrical ultrasound system for breast hyperthermia
    • 10.1088/0031-9155/51/3/005
    • K. C. Ju, L. T. Tseng, Y. Y. Chen, and W. L. Lin, Investigation of a scanned cylindrical ultrasound system for breast hyperthermia., Phys. Med. Biol. 51 (3), 539-555 (2006). 10.1088/0031-9155/51/3/005
    • (2006) Phys. Med. Biol. , vol.51 , Issue.3 , pp. 539-555
    • Ju, K.C.1    Tseng, L.T.2    Chen, Y.Y.3    Lin, W.L.4
  • 21
    • 0024739554 scopus 로고
    • Multiple-focus ultrasound phased-array pattern synthesis: Optimal driving-signal distributions for hyperthermia
    • 10.1109/58.31798
    • E. S. Ebbini and C. A. Cain, Multiple-focus ultrasound phased-array pattern synthesis: Optimal driving-signal distributions for hyperthermia., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 36 (5), 540-548 (1989). 10.1109/58.31798
    • (1989) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.36 , Issue.5 , pp. 540-548
    • Ebbini, E.S.1    Cain, C.A.2
  • 22
    • 0024533068 scopus 로고
    • Relation of tumor size, lymph node status, and survival in 24,740 breast cancer cases
    • 10.1002/(ISSN)1097-0142
    • C. L. Carter, C. Allen, and D. E. Henson, Relation of tumor size, lymph node status, and survival in 24,740 breast cancer cases., Cancer 63 (1), 181-187 (1989). 10.1002/(ISSN)1097-0142
    • (1989) Cancer , vol.63 , Issue.1 , pp. 181-187
    • Carter, C.L.1    Allen, C.2    Henson, D.E.3
  • 23
    • 0033907616 scopus 로고    scopus 로고
    • A theoretical assessment of the relative performance of spherical phased arrays for ultrasound surgery
    • 10.1109/58.818755
    • L. R. Gavrilov and J. W. Hand, A theoretical assessment of the relative performance of spherical phased arrays for ultrasound surgery., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 47 (1), 125-139 (2000). 10.1109/58.818755
    • (2000) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.47 , Issue.1 , pp. 125-139
    • Gavrilov, L.R.1    Hand, J.W.2
  • 25
    • 84878406647 scopus 로고    scopus 로고
    • An 11-channel phased array radio frequency coil array for magnetic resonance guided high intensity focused ultrasound of the breast
    • accepted
    • E. Minalga, A. Payne, R. Merrill, N. Todd, S. Vijayakumar, E. Kholmovski, D. Parker, and J. Hadley, An 11-channel phased array radio frequency coil array for magnetic resonance guided high intensity focused ultrasound of the breast., Magn. Reson. Med. (accepted).
    • Magn. Reson. Med
    • Minalga, E.1    Payne, A.2    Merrill, R.3    Todd, N.4    Vijayakumar, S.5    Kholmovski, E.6    Parker, D.7    Hadley, J.8
  • 27
    • 0000714697 scopus 로고    scopus 로고
    • A novel metod to reduce the signal coupling of surface coils for MRI
    • New York
    • J. Wang, A novel metod to reduce the signal coupling of surface coils for MRI., International Society of Magnetic Resonance in Medicine (1996), New York, p. 1434.
    • (1996) International Society of Magnetic Resonance in Medicine , pp. 1434
    • Wang, J.1
  • 29
    • 0028785052 scopus 로고
    • A precise and fast temperature mapping using water proton chemical shift
    • 10.1002/(ISSN)1522-2594
    • Y. Ishihara, A. Calderon, H. Watanabe, K. Okamoto, Y. Suzuki, K. Kuroda, and Y. Suzuki, A precise and fast temperature mapping using water proton chemical shift., Magn. Reson. Med. 34 (6), 814-823 (1995). 10.1002/(ISSN)1522- 2594
    • (1995) Magn. Reson. Med. , vol.34 , Issue.6 , pp. 814-823
    • Ishihara, Y.1    Calderon, A.2    Watanabe, H.3    Okamoto, K.4    Suzuki, Y.5    Kuroda, K.6    Suzuki, Y.7
  • 30
    • 33744607266 scopus 로고
    • The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two-dimensional time-dependent temperature distribution in a phantom
    • 10.1006/jmrb.1994.1035
    • J. De Poorter, C. De Wagter, Y. De Deene, and C. Thomsen, The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two-dimensional time-dependent temperature distribution in a phantom., J. Magn. Reson., Ser. B 103, 234-241 (1994). 10.1006/jmrb.1994.1035
    • (1994) J. Magn. Reson., Ser. B , vol.103 , pp. 234-241
    • De Poorter, J.1    De Wagter, C.2    De Deene, Y.3    Thomsen, C.4
  • 31
    • 77956880943 scopus 로고    scopus 로고
    • Accuracy of real-time MR temperature mapping in the brain: A comparison of fast sequences
    • 10.1016/j.ejm2009.11.006
    • A. Kickhefel, J. Roland, C. Weiss, and F. Schick, Accuracy of real-time MR temperature mapping in the brain: A comparison of fast sequences., Phys. Med. 26 (4), 192-201 (2010). 10.1016/j.ejmp.2009.11.006
    • (2010) Phys. Med. , vol.26 , Issue.4 , pp. 192-201
    • Kickhefel, A.1    Roland, J.2    Weiss, C.3    Schick, F.4
  • 32
    • 79251540606 scopus 로고    scopus 로고
    • The effects of spatial sampling choices on MR temperature measurements
    • 10.1002/mrm.22636
    • N. Todd, U. Vyas, J. de Bever, A. Payne, and D. L. Parker, The effects of spatial sampling choices on MR temperature measurements., Magn. Reson. Med. 65 (2), 515-521 (2011). 10.1002/mrm.22636
    • (2011) Magn. Reson. Med. , vol.65 , Issue.2 , pp. 515-521
    • Todd, N.1    Vyas, U.2    De Bever, J.3    Payne, A.4    Parker, D.L.5
  • 33
    • 80052411071 scopus 로고    scopus 로고
    • The effect of electronically steering a phased array ultrasound transducer on near-field tissue heating
    • 10.1118/1.3618729
    • A. Payne, U. Vyas, N. Todd, J. de Bever, D. A. Christensen, and D. L. Parker, The effect of electronically steering a phased array ultrasound transducer on near-field tissue heating., Med. Phys. 38 (9), 4971-4981. 10.1118/1.3618729
    • Med. Phys. , vol.38 , Issue.9 , pp. 4971-4981
    • Payne, A.1    Vyas, U.2    Todd, N.3    De Bever, J.4    Christensen, D.A.5    Parker, D.L.6
  • 34
    • 58149267910 scopus 로고    scopus 로고
    • Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy
    • 10.1088/0031-9155/53/22/017
    • M. Rata, R. Salomir, R. Umathum, J. Jenne, C. Lafon, F. Cotton, and M. Bock, Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy., Phys. Med. Biol. 53 (22), 6549-6567 (2008). 10.1088/0031-9155/53/22/017
    • (2008) Phys. Med. Biol. , vol.53 , Issue.22 , pp. 6549-6567
    • Rata, M.1    Salomir, R.2    Umathum, R.3    Jenne, J.4    Lafon, C.5    Cotton, F.6    Bock, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.