메뉴 건너뛰기




Volumn 54, Issue 1, 2005, Pages 235-240

Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging

Author keywords

7 T; High field MRI; Phased array; RF coil design; SNR

Indexed keywords

ANTENNA PHASED ARRAYS; BRAIN MAPPING;

EID: 21244493990     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20547     Document Type: Article
Times cited : (76)

References (18)
  • 2
    • 0024411731 scopus 로고
    • Power deposition and noise correlation in NMR samples
    • Carlson JW. Power deposition and noise correlation in NMR samples. Magn Reson Med 1989;10:399-403.
    • (1989) Magn Reson Med , vol.10 , pp. 399-403
    • Carlson, J.W.1
  • 5
    • 0029147415 scopus 로고
    • Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain
    • Wald LL, Carvajal L, Moyher SE, Nelson SJ, Grant PE, Barkovich AJ, Vigneron DB. Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain. Magn Reson Med 1995;34:433-439.
    • (1995) Magn Reson Med , vol.34 , pp. 433-439
    • Wald, L.L.1    Carvajal, L.2    Moyher, S.E.3    Nelson, S.J.4    Grant, P.E.5    Barkovich, A.J.6    Vigneron, D.B.7
  • 6
    • 0346373773 scopus 로고    scopus 로고
    • Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    • de Zwart JA, Ledden PJ, van Gelderen P, Bodurka J, Chu R, Duyn JH. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla. Magn Reson Med 2004;51:22-26.
    • (2004) Magn Reson Med , vol.51 , pp. 22-26
    • De Zwart, J.A.1    Ledden, P.J.2    Van Gelderen, P.3    Bodurka, J.4    Chu, R.5    Duyn, J.H.6
  • 9
    • 0033959514 scopus 로고    scopus 로고
    • A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
    • Barberi EA, Gati JS, Rutt BK, Menon RS. A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications. Magn Reson Med 2000;43:284-289.
    • (2000) Magn Reson Med , vol.43 , pp. 284-289
    • Barberi, E.A.1    Gati, J.S.2    Rutt, B.K.3    Menon, R.S.4
  • 10
    • 18544377165 scopus 로고    scopus 로고
    • A detunable elliptic transmission line resonator for body imaging at 3Tesla
    • Ledden PJ, Wald LL, Hinton DP. A detunable elliptic transmission line resonator for body imaging at 3Tesla. Concepts Magn Reson 2002;15:92-100.
    • (2002) Concepts Magn Reson , vol.15 , pp. 92-100
    • Ledden, P.J.1    Wald, L.L.2    Hinton, D.P.3
  • 11
    • 0037899269 scopus 로고    scopus 로고
    • An MR transceive phased array designed for spinal cord imaging at 3 Tesla: Preliminary investigations of spinal cord imaging at 3 T
    • Peterson DM, Duensing GR, Caserta J, Fitzsimmons JR. An MR transceive phased array designed for spinal cord imaging at 3 Tesla: preliminary investigations of spinal cord imaging at 3 T. Invest Radiol 2003;38:428-435.
    • (2003) Invest Radiol , vol.38 , pp. 428-435
    • Peterson, D.M.1    Duensing, G.R.2    Caserta, J.3    Fitzsimmons, J.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.