-
3
-
-
84862096443
-
Osteoporosis-related fracture case definitions for population-based administrative data
-
Lix LM, Azimaee M, Osman BA, et al. Osteoporosis-related fracture case definitions for population-based administrative data. BMC Publ Health. 2012;12:301.
-
(2012)
BMC Publ Health
, vol.12
, pp. 301
-
-
Lix, L.M.1
Azimaee, M.2
Osman, B.A.3
-
4
-
-
79959941054
-
Medical costs of osteoporosis in the elderly Medicare population
-
Blume SW, Curtis Jr. Medical costs of osteoporosis in the elderly Medicare population. Osteoporos Int. 2011;22(6):1835-44.
-
(2011)
Osteoporos Int.
, vol.22
, Issue.6
, pp. 44
-
-
Blume, S.W.1
Curtis, J.R.2
-
5
-
-
77953342300
-
Cost of fractures commonly associated with osteoporosis in a managed-care population
-
Christensen L, Iqbal S, Macarios D, et al. Cost of fractures commonly associated with osteoporosis in a managed-care population. J Med Economics. 2010;13(2):302-13.
-
(2010)
J Med Economics.
, vol.13
, Issue.2
, pp. 302-313
-
-
Christensen, L.1
Iqbal, S.2
Macarios, D.3
-
6
-
-
0015305703
-
Dual plating of selected femoral fractures
-
Ruoff III AC, Biddulph EC. Dual plating of selected femoral fractures. J Trauma. 1972;12(3):233-41.
-
(1972)
J Trauma.
, vol.12
, Issue.3
, pp. 233-241
-
-
Ruoff III, A.C.1
Biddulph, E.C.2
-
7
-
-
0028692168
-
Femur fractures with femoral or popliteal artery injuries in blunt trauma
-
DiChristina DG, Riemer BL, Butterfield SL, et al. Femur fractures with femoral or popliteal artery injuries in blunt trauma. J Orthop Trauma. 1994;8(6):494-503.
-
(1994)
J Orthop Trauma.
, vol.8
, Issue.6
, pp. 494-503
-
-
DiChristina, D.G.1
Riemer, B.L.2
Butterfield, S.L.3
-
8
-
-
0026643642
-
Immediate plate fixation of highly comminuted femoral diaphyseal fractures in blunt polytrauma patients
-
Riemer BL, Butterfield SL, Burke III CJ, et al. Immediate plate fixation of highly comminuted femoral diaphyseal fractures in blunt polytrauma patients. Orthopedics. 1992;15(8):907-16.
-
(1992)
Orthopedics.
, vol.15
, Issue.8
, pp. 907-916
-
-
Riemer, B.L.1
Butterfield, S.L.2
Burke III, C.J.3
-
9
-
-
0018776780
-
Closed intramedullary nailing of the femur. Kuntscher technique with reaming
-
Hansen ST, Winquist RA. Closed intramedullary nailing of the femur. Kuntscher technique with reaming. Clin Orthop. ;138:56-61.
-
Clin Orthop.
, vol.138
, pp. 56-61
-
-
Hansen, S.T.1
Winquist, R.A.2
-
10
-
-
0018026371
-
Segmental fractures of the femur treated by closed intramedullary nailing
-
Winquist RA, Hansen ST. Segmental fractures of the femur treated by closed intramedullary nailing. J Bone Joint Surg [Am]. 1978;60(7):934-9.
-
(1978)
J Bone Joint Surg [Am].
, vol.60
, Issue.7
, pp. 934-939
-
-
Winquist, R.A.1
Hansen, S.T.2
-
11
-
-
0022481192
-
The treatment of fractures of the femoral shaft with the Brooker-Wills distal locking intramedullary nail
-
White GM, Healy WL, Brumback RJ, et al. The treatment of fractures of the femoral shaft with the Brooker-Wills distal locking intramedullary nail. J Bone Joint Surg [Am]. 1986;68(6):865-76. (Pubitemid 16074362)
-
(1986)
Journal of Bone and Joint Surgery - Series A
, vol.68
, Issue.6
, pp. 865-876
-
-
White, G.M.1
Healy, W.L.2
Brumback, R.J.3
-
12
-
-
0032720511
-
Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail
-
Brumback RJ, Toal Jr TR, Murphy-Zane MS, et al. Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail. J Bone Joint Surg [Am]. 1999;81(11):1538-44.
-
(1999)
J Bone Joint Surg [Am].
, vol.81
, Issue.11
, pp. 1538-1544
-
-
Brumback, R.J.1
Toal Jr., T.R.2
Murphy-Zane, M.S.3
-
13
-
-
33746923045
-
Functional outcomes of severe bicondylar tibial plateau fractures treated with dual incisions and medial and lateral plates
-
DOI 10.2106/JBJS.E.00907
-
Barei DP, Nork SE, Mills WJ, et al. Functional outcomes of severe bicondylar tibial plateau fractures treated with dual incisions and medial and lateral plates. J Bone Joint Surg [Am]. 2006;88(8):1713-21. (Pubitemid 44200208)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.8
, pp. 1713-1721
-
-
Barei, D.P.1
Nork, S.E.2
Mills, W.J.3
Coles, C.P.4
Henley, M.B.5
Benirschke, S.K.6
-
14
-
-
16644381922
-
Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique
-
DOI 10.1097/00005131-200411000-00001
-
Barei DP, Nork SE, Mills WJ, et al. Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma. 2004;18(10):649-57. (Pubitemid 40533063)
-
(2004)
Journal of Orthopaedic Trauma
, vol.18
, Issue.10
, pp. 649-657
-
-
Barei, D.P.1
Nork, S.E.2
Mills, W.J.3
Henley, M.B.4
Benirschke, S.K.5
-
15
-
-
78650787295
-
Dual plating for fractures of the distal third of the humeral shaft
-
Prasarn ML, Ahn J, Paul O, et al. Dual plating for fractures of the distal third of the humeral shaft. J Orthop Trauma. 2011;25 (1):57-63.
-
(2011)
J Orthop Trauma.
, vol.25
, Issue.1
, pp. 57-63
-
-
Prasarn, M.L.1
Ahn, J.2
Paul, O.3
-
16
-
-
3543045554
-
Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius
-
Ring D, Prommersberger K, Jupiter JB. Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg [Am]. 2004;86-A(8):1646-52. (Pubitemid 39014307)
-
(2004)
Journal of Bone and Joint Surgery - Series A
, vol.86
, Issue.8
, pp. 1646-1652
-
-
Ring, D.1
Prommersberger, K.2
Jupiter, J.B.3
-
17
-
-
79351469598
-
Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
-
Chen LH, Tai CL, Lee DM, et al. Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling. BMC Musculoskelet Disord. 2011;12:33.
-
(2011)
BMC Musculoskelet Disord
, vol.12
, pp. 33
-
-
Chen, L.H.1
Tai, C.L.2
Lee, D.M.3
-
18
-
-
0036096933
-
The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices
-
DOI 10.1097/00005131-200205000-00003
-
Eriksson F, Mattsson P, Larsson S. The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices. J Orthop Trauma. 2002;16(5):302-10. (Pubitemid 34520561)
-
(2002)
Journal of Orthopaedic Trauma
, vol.16
, Issue.5
, pp. 302-310
-
-
Eriksson, F.1
Mattsson, P.2
Larsson, S.3
-
19
-
-
33745073501
-
Cement augmentation in fracture treatment
-
Larsson S. Cement augmentation in fracture treatment. Scand J Surg. 2006;95(2):111-8. (Pubitemid 43886196)
-
(2006)
Scandinavian Journal of Surgery
, vol.95
, Issue.2
, pp. 111-118
-
-
Larsson, S.1
-
20
-
-
0347286912
-
Prevention of hip lag screw cut-out by cement augmentation: Description of a new technique and preliminary clinical results
-
DOI 10.1097/00005131-200401000-00007
-
Szpalski M, Descamps PY, Hayez JP, et al. Prevention of hip lag screw cut-out by cement augmentation: Description of a new technique and preliminary clinical results. J Orthop Trauma. 2004;18(1):34-40. (Pubitemid 38072390)
-
(2004)
Journal of Orthopaedic Trauma
, vol.18
, Issue.1
, pp. 34-40
-
-
Szpalski, M.1
Descamps, P.-Y.2
Hayez, J.-P.3
Raad, E.4
Gunzburg, R.5
Keller, T.S.6
Kosmopoulos, V.7
-
21
-
-
33744785669
-
Intradural cement leakage: A devastatingly rare complication of vertebroplasty
-
Chen YJ, Tan TS, Chen WH, et al. Intradural cement leakage: A devastatingly rare complication of vertebroplasty. Spine. 2006;31 (12):E379-82.
-
(2006)
Spine.
, vol.31
, Issue.12
-
-
Chen, Y.J.1
Tan, T.S.2
Chen, W.H.3
-
22
-
-
62149101565
-
Right ventricular acrylic cement embolism: Late complication of percutaneous vertebroplasty
-
Braiteh F, Row M. Right ventricular acrylic cement embolism: Late complication of percutaneous vertebroplasty. Heart. 2009;95(4):275.
-
(2009)
Heart
, vol.95
, Issue.4
, pp. 275
-
-
Braiteh, F.1
Row, M.2
-
23
-
-
35148878574
-
Pulmonary cement embolism: A complication of percutaneous vertebroplasty
-
DOI 10.1080/02841850701422153, PII 782896802
-
Duran C, Sirvanci M, Aydogan M, et al. Pulmonary cement embolism: A complication of percutaneous vertebroplasty. Acta Radiol. 2007;48(8):854-9. (Pubitemid 47551925)
-
(2007)
Acta Radiologica
, vol.48
, Issue.8
, pp. 854-859
-
-
Duran, C.1
Sirvanci, M.2
Aydoan, M.3
Ozturk, E.4
Ozturk, C.5
Akman, C.6
-
24
-
-
57649146480
-
Cardiac tamponade and pulmonary embolism as a complication of percutaneous vertebroplasty
-
Caynak B, Onan B, Sagbas E, et al. Cardiac tamponade and pulmonary embolism as a complication of percutaneous vertebroplasty. Ann Thorac Surg. 2009;87(1):299-301.
-
(2009)
Ann Thorac Surg.
, vol.87
, Issue.1
, pp. 299-301
-
-
Caynak, B.1
Onan, B.2
Sagbas, E.3
-
25
-
-
0036782669
-
Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report
-
Lee BJ, Lee SR, Yoo TY. Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report. Spine. 2002;27(19):E419-22.
-
(2002)
Spine.
, vol.27
, Issue.19
-
-
Lee, B.J.1
Lee, S.R.2
Yoo, T.Y.3
-
26
-
-
84859916179
-
Kyphoplasty in patients with multiple myeloma a retrospective comparative pilot study
-
Kasperk C, Haas A, Hillengass J, et al. Kyphoplasty in patients with multiple myeloma a retrospective comparative pilot study. J Surg Oncol. 2012;105(7):679-86.
-
(2012)
J Surg Oncol.
, vol.105
, Issue.7
, pp. 679-686
-
-
Kasperk, C.1
Haas, A.2
Hillengass, J.3
-
27
-
-
70350639313
-
Kyphoplasty for patients with multiple myeloma is a safe surgical procedure: Results from a large patient cohort
-
Huber FX, McArthur N, Tanner M, et al. Kyphoplasty for patients with multiple myeloma is a safe surgical procedure: Results from a large patient cohort. Clinical Lymphoma Myeloma. 2009;9(5):375-80.
-
(2009)
Clinical Lymphoma Myeloma.
, vol.9
, Issue.5
, pp. 375-380
-
-
Huber, F.X.1
McArthur, N.2
Tanner, M.3
-
28
-
-
84872182889
-
Early clinical outcome and complications related to balloon kyphoplasty
-
Bergmann M, Oberkircher L, Bliemel C, et al. Early clinical outcome and complications related to balloon kyphoplasty. Orthop Revl. 2012;4(2):e25.
-
(2012)
Orthop Revl.
, vol.4
, Issue.2
-
-
Bergmann, M.1
Oberkircher, L.2
Bliemel, C.3
-
29
-
-
28844444049
-
Vertebroplasty and kyphoplasty: Techniques for avoiding complications and pitfalls
-
Wong W, Mathis JM. Vertebroplasty and kyphoplasty: Techniques for avoiding complications and pitfalls. Neurosurg Focus. 2005;18(3):e2.
-
(2005)
Neurosurg Focus.
, vol.18
, Issue.3
-
-
Wong, W.1
Mathis, J.M.2
-
30
-
-
84859223352
-
Comparison of vertebroplasty and kyphoplasty for complications
-
Zhang JD, Poffyn B, Sys G, et al. Comparison of vertebroplasty and kyphoplasty for complications. Orthop Surg. 2011;3(3):158-60.
-
(2011)
Orthop Surg.
, vol.3
, Issue.3
, pp. 158-160
-
-
Zhang, J.D.1
Poffyn, B.2
Sys, G.3
-
31
-
-
77952944276
-
Complications and safety aspects of kyphoplasty for osteoporotic vertebral fractures: A prospective follow-up study in 102 consecutive patients
-
Robinson Y, Tschoke SK, Stahel PF, et al. Complications and safety aspects of kyphoplasty for osteoporotic vertebral fractures: A prospective follow-up study in 102 consecutive patients. Patient Safety Surg. 2008;2:2.
-
(2008)
Patient Safety Surg.
, vol.2
, pp. 2
-
-
Robinson, Y.1
Tschoke, S.K.2
Stahel, P.F.3
-
32
-
-
76549111433
-
Balloon kyphoplasty vs vertebroplasty for treatment of osteoporotic vertebral compression fracture: A prospective, comparative, and randomized clinical study
-
Liu JT, Liao WJ, Tan WC, et al. Balloon kyphoplasty vs vertebroplasty for treatment of osteoporotic vertebral compression fracture: A prospective, comparative, and randomized clinical study. Osteoporos Int. 2010;21(2):359-64.
-
(2010)
Osteoporos Int.
, vol.21
, Issue.2
, pp. 359-364
-
-
Liu, J.T.1
Liao, W.J.2
Tan, W.C.3
-
33
-
-
67749131047
-
Percutaneous vertebroplasty compared with conservative treatment in patients with painful acute or subacute osteoporotic vertebral fractures: Three-months follow-up in a clinical randomized study
-
Rousing R, Andersen MO, Jespersen SM, et al. Percutaneous vertebroplasty compared with conservative treatment in patients with painful acute or subacute osteoporotic vertebral fractures: Three-months follow-up in a clinical randomized study. Spine. 2009;34(13):1349-54.
-
(2009)
Spine.
, vol.34
, Issue.13
, pp. 1349-1354
-
-
Rousing, R.1
Andersen, M.O.2
Jespersen, S.M.3
-
34
-
-
71449093794
-
Response to "randomized vertebroplasty trials: Bad news or sham news?"
-
Kallmes D, Buchbinder R, Jarvik J, et al. Response to "randomized vertebroplasty trials: Bad news or sham news?". AJNR. 2009;30(10):1809-10.
-
(2009)
AJNR
, vol.30
, Issue.10
, pp. 1809-1810
-
-
Kallmes, D.1
Buchbinder, R.2
Jarvik, J.3
-
36
-
-
68249154874
-
A randomized trial of vertebroplasty for osteoporotic spinal fractures
-
Kallmes DF, Comstock BA, Heagerty PJ, et al. A randomized trial of vertebroplasty for osteoporotic spinal fractures. N Engl J Med. 2009;361(6):569-79.
-
(2009)
N Engl J Med.
, vol.361
, Issue.6
, pp. 569-579
-
-
Kallmes, D.F.1
Comstock, B.A.2
Heagerty, P.J.3
-
37
-
-
68249144371
-
A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures
-
Buchbinder R, Osborne RH, Ebeling PR, et al. A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures. N Enl J Med. 2009;361(6):557-68.
-
(2009)
N Enl J Med.
, vol.361
, Issue.6
, pp. 557-568
-
-
Buchbinder, R.1
Osborne, R.H.2
Ebeling, P.R.3
-
38
-
-
84859529371
-
Effect of vertebroplasty on pain relief, quality of life, and the incidence of new vertebral fractures: A 12-month randomized follow-up, controlled trial
-
Blasco J, Martinez-Ferrer A, Macho J, et al. Effect of vertebroplasty on pain relief, quality of life, and the incidence of new vertebral fractures: A 12-month randomized follow-up, controlled trial. J Bone Miner Res. 2012;27(5):1159-66.
-
(2012)
J Bone Miner Res.
, vol.27
, Issue.5
, pp. 1159-1166
-
-
Blasco, J.1
Martinez-Ferrer, A.2
Macho, J.3
-
39
-
-
77951073193
-
Dynamic hip screws for unstable intertrochanteric fractures in elderly patients-encouraging results with a cement augmentation technique
-
Lee PC, Hsieh PH, Chou YC, et al. Dynamic hip screws for unstable intertrochanteric fractures in elderly patients-encouraging results with a cement augmentation technique. J Trauma. 2010;68(4):954-64.
-
(2010)
J Trauma.
, vol.68
, Issue.4
, pp. 954-964
-
-
Lee, P.C.1
Hsieh, P.H.2
Chou, Y.C.3
-
40
-
-
80755136667
-
Standardised cement augmentation of the PFNA using a perforated blade: A new technique and preliminary clinical results
-
Kammerlander C, Gebhard F, Meier C, et al. Standardised cement augmentation of the PFNA using a perforated blade: A new technique and preliminary clinical results. A prospective multicentre trial Injury. 2011;42(12):1484-90.
-
(2011)
A prospective multicentre trial Injury.
, vol.42
, Issue.12
, pp. 1484-1490
-
-
Kammerlander, C.1
Gebhard, F.2
Meier, C.3
-
41
-
-
67651162056
-
Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device
-
Waits C, Burton D, McIff T. Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device. Spine. 2009;34(14):E478-83.
-
(2009)
Spine.
, vol.34
, Issue.14
-
-
Waits, C.1
Burton, D.2
McIff, T.3
-
42
-
-
80053200242
-
Fracture prevention by femoroplasty-cement augmentation of the proximal femur
-
Beckmann J, Springorum R, Vettorazzi E, et al. Fracture prevention by femoroplasty-cement augmentation of the proximal femur. J Orthop Res. 2011;29(11):1753-8.
-
(2011)
J Orthop Res.
, vol.29
, Issue.11
, pp. 1753-1758
-
-
Beckmann, J.1
Springorum, R.2
Vettorazzi, E.3
-
43
-
-
77953912560
-
Percutaneous cement augmentation for the treatment of depression fractures of the tibial plateau
-
Evangelopoulos DS, Heitkemper S, Eggli S, et al. Percutaneous cement augmentation for the treatment of depression fractures of the tibial plateau. Knee Surg Sports Traumatol Arthroscopy. 2010;18(7):911-5.
-
(2010)
Knee Surg Sports Traumatol Arthroscopy.
, vol.18
, Issue.7
, pp. 911-915
-
-
Evangelopoulos, D.S.1
Heitkemper, S.2
Eggli, S.3
-
44
-
-
0036528644
-
Catastrophic fat embolism following augmentation of pedicle screws with bone cement: A case report
-
Temple JD, Ludwig SC, Ross WK, et al. Catastrophic fat embolism following augmentation of pedicle screws with bone cement: A case report. J Bone Joint Surg [Am]. 2002;84-A(4):639-42.
-
(2002)
J Bone Joint Surg [Am].
, vol.84 A
, Issue.4
, pp. 639-642
-
-
Temple, J.D.1
Ludwig, S.C.2
Ross, W.K.3
-
45
-
-
59649087877
-
Augmentation of pedicle screw fixation strength using an injectable calcium sulfate cement: An in vivo study
-
Yi X, Wang Y, Lu H, et al. Augmentation of pedicle screw fixation strength using an injectable calcium sulfate cement: An in vivo study. Spine. 2008;33(23):2503-9.
-
(2008)
Spine.
, vol.33
, Issue.23
, pp. 2503-2509
-
-
Yi, X.1
Wang, Y.2
Lu, H.3
-
46
-
-
0035073910
-
Radiostereometric analysis of distal radial fracture displacement during treatment: A randomized study comparing Norian SRS and external fixation in 23 patients
-
DOI 10.1080/000164701753606707
-
Kopylov P, Aspenberg P, Yuan X, et al. Radiostereometric analysis of distal radial fracture displacement during treatment: A randomized study comparing Norian SRS and external fixation in 23 patients. Acta Orthopaedica Scandinavica. 2001;72(1):57-61. (Pubitemid 32281145)
-
(2001)
Acta Orthopaedica Scandinavica
, vol.72
, Issue.1
, pp. 57-61
-
-
Kopylov, P.1
Aspenberg, P.2
Yuan, X.3
Ryd, L.4
-
48
-
-
0242659161
-
Norian SRS cement compared with conventional fixation in distal radial fractures. A randomized study
-
Cassidy C, Jupiter JB, Cohen M, et al. Norian SRS cement compared with conventional fixation in distal radial fractures. A randomized study. J Bone Joint Surg [Am]. 2003;85-A(11):2127-37. (Pubitemid 37385910)
-
(2003)
Journal of Bone and Joint Surgery - Series A
, vol.85
, Issue.11
, pp. 2127-2137
-
-
Cassidy, C.1
Jupiter, J.B.2
Cohen, M.3
Delli-Santi, M.4
Fennell, C.5
Leinberry, C.6
Husband, J.7
Ladd, A.8
Seitz, W.R.9
Constanz, B.10
-
49
-
-
78149281362
-
Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation
-
Stadelmann VA, Bretton E, Terrier A, et al. Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation. J Biomech. 2010;43 (15):2869-74.
-
(2010)
J Biomech.
, vol.43
, Issue.15
, pp. 2869-2874
-
-
Stadelmann, V.A.1
Bretton, E.2
Terrier, A.3
-
51
-
-
80052405099
-
Single-stage total hip arthroplasty and fracture fixation for a both column acetabular fracture in type I osteogenesis imperfecta
-
Liporace FA, Yoon RS, Frank MA, et al. Single-stage total hip arthroplasty and fracture fixation for a both column acetabular fracture in type I osteogenesis imperfecta. Injury. 2011;42 (10):1184-7.
-
(2011)
Injury.
, vol.42
, Issue.10
, pp. 1184-1187
-
-
Liporace, F.A.1
Yoon, R.S.2
Frank, M.A.3
-
52
-
-
84859160750
-
Surgical technique: Intraacetabular osteosynthesis with arthroplasty for acetabular fracture in the octogenarian
-
Guerado E, Cano JR, Cruz E. Surgical technique: Intraacetabular osteosynthesis with arthroplasty for acetabular fracture in the octogenarian. Injury. 2012;43(4):509-12.
-
(2012)
Injury.
, vol.43
, Issue.4
, pp. 509-512
-
-
Guerado, E.1
Cano, J.R.2
Cruz, E.3
-
53
-
-
84867717740
-
Total shoulder arthroplasty for the treatment of failed hemiarthroplasty in patients with fracture of the proximal humerus
-
Postacchini R, Castagna A, Borroni M, et al. Total shoulder arthroplasty for the treatment of failed hemiarthroplasty in patients with fracture of the proximal humerus. J Shoulder Ebow Surg. 2012.
-
(2012)
J Shoulder Ebow Surg.
-
-
Postacchini, R.1
Castagna, A.2
Borroni, M.3
-
54
-
-
84864285168
-
Complex Distal Humerus Fractures in Elderly Patients: Open reduction and internal fixation versus arthroplasty
-
Patino JM. Complex Distal Humerus Fractures in Elderly Patients: Open reduction and internal fixation versus arthroplasty. J Hand Surg [Am]. 2012.
-
(2012)
J Hand Surg [Am].
-
-
Patino, J.M.1
-
55
-
-
84863985261
-
The use of the Lima reverse shoulder arthroplasty for the treatment of fracture sequelae of the proximal humerus
-
Martinez AA, Calvo A, Bejarano C, et al. The use of the Lima reverse shoulder arthroplasty for the treatment of fracture sequelae of the proximal humerus. J Orthopaed Sci. 2012;17(2):141-7.
-
(2012)
J Orthopaed Sci.
, vol.17
, Issue.2
, pp. 141-147
-
-
Martinez, A.A.1
Calvo, A.2
Bejarano, C.3
-
56
-
-
80155194215
-
Comparison of functional outcomes of total elbow arthroplasty vs plate fixation for distal humerus fractures in osteoporotic elbows
-
Egol KA, Tsai P, Vazques O, et al. Comparison of functional outcomes of total elbow arthroplasty vs plate fixation for distal humerus fractures in osteoporotic elbows. Am J Orthop (Belle Mead NJ). 2011;40(2):67-71.
-
(2011)
Am J Orthop (Belle Mead NJ).
, vol.40
, Issue.2
, pp. 67-71
-
-
Egol, K.A.1
Tsai, P.2
Vazques, O.3
-
57
-
-
84858433801
-
Arthroplasty for fractures of the proximal part of the humerus
-
Voos JE, Dines JS, Dines DM. Arthroplasty for fractures of the proximal part of the humerus. Instr Course Lect. 2011;60:105-12.
-
(2011)
Instr Course Lect.
, vol.60
, pp. 105-112
-
-
Voos, J.E.1
Dines, J.S.2
Dines, D.M.3
-
58
-
-
84867889718
-
Salvage of failed trochanteric fracture fixation using the revitan curved cementless modular hip arthroplasty
-
Abouelela AA. Salvage of failed trochanteric fracture fixation using the revitan curved cementless modular hip arthroplasty. J Arthroplasty. 2011.
-
(2011)
J Arthroplasty.
-
-
Abouelela, A.A.1
-
59
-
-
82455163668
-
Hemiarthroplasty and total hip arthroplasty for treating primary intracapsular fracture of the hip: A systematic review and cost-effectiveness analysis
-
Carroll C, Stevenson M, Scope A, et al. Hemiarthroplasty and total hip arthroplasty for treating primary intracapsular fracture of the hip: A systematic review and cost-effectiveness analysis. Health Technol Assess. 2011;15(36):1-74.
-
(2011)
Health Technol Assess.
, vol.15
, Issue.36
, pp. 1-74
-
-
Carroll, C.1
Stevenson, M.2
Scope, A.3
-
60
-
-
0027603035
-
Primary resection total knee arthroplasty for complicated fracture of the distal femur with an arthritic knee joint
-
Shah A, Asirvatham R, Sudlow RA. Primary resection total knee arthroplasty for complicated fracture of the distal femur with an arthritic knee joint. Contemp Orthopaed. 1993;26(5):463-7.
-
(1993)
Contemp Orthopaed.
, vol.26
, Issue.5
, pp. 463-467
-
-
Shah, A.1
Asirvatham, R.2
Sudlow, R.A.3
-
61
-
-
33746522481
-
Short-term outcomes of total hip arthroplasty after complications of open reduction internal fixation for hip fracture
-
DOI 10.1016/j.arth.2005.08.013, PII S0883540305005103
-
Winemaker M, Gamble P, Petruccelli D, et al. Short-term outcomes of total hip arthroplasty after complications of open reduction internal fixation for hip fracture. J Arthroplasty. 2006;21 (5):682-8. (Pubitemid 44131645)
-
(2006)
Journal of Arthroplasty
, vol.21
, Issue.5
, pp. 682-688
-
-
Winemaker, M.1
Gamble, P.2
Petruccelli, D.3
Kaspar, S.4
De Beer, J.5
-
64
-
-
33747889978
-
Long-term outcome and risk factors of proximal femoral fracture in uncemented and cemented total hip arthroplasty in 2551 hips
-
DOI 10.1016/j.arth.2006.05.014, PII S0883540306003883
-
Berend ME, Smith A, Meding JB, et al. Long-term outcome and risk factors of proximal femoral fracture in uncemented and cemented total hip arthroplasty in 2551 hips. J Arthroplasty. 2006;21(6 Suppl 2):53-9. (Pubitemid 44293265)
-
(2006)
Journal of Arthroplasty
, vol.21
, Issue.6 SUPPL.
, pp. 53-59
-
-
Berend, M.E.1
Smith, A.2
Meding, J.B.3
Ritter, M.A.4
Lynch, T.5
Davis, K.6
-
66
-
-
0033986888
-
Transesophageal echocardiography and clinical features of fat embolism during cemented total hip arthroplasty. A randomized study in patients with a femoral neck fracture
-
Pitto RP, Blunk J, Kossler M. Transesophageal echocardiography and clinical features of fat embolism during cemented total hip arthroplasty. A randomized study in patients with a femoral neck fracture. Arch Orthopaed Trauma Surg. 2000;120(1-2):53-8. (Pubitemid 30009187)
-
(2000)
Archives of Orthopaedic and Trauma Surgery
, vol.120
, Issue.1-2
, pp. 53-58
-
-
Pitto, R.P.1
Blunk, J.2
Kossler, M.3
-
67
-
-
0027248740
-
Hypotension during cemented arthroplasty Relationship to cardiac output and fat embolism
-
Wheelwright EF, Byrick RJ, Wigglesworth DF, et al. Hypotension during cemented arthroplasty. Relationship to cardiac output and fat embolism. J Bone Joint Surg Br. 1993;75(5):715-23. (Pubitemid 23267933)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.5
, pp. 715-723
-
-
Wheelwright, E.F.1
Byrick, R.J.2
Wigglesworth, D.F.3
Kay, J.C.4
Wong, P.Y.5
Mullen, J.B.6
Waddell, J.P.7
-
69
-
-
43049137358
-
Biomechanical strength of the Peri-Loc proximal tibial plate: A comparison of all-locked versus hybrid locked/nonlocked screw configurations
-
DOI 10.1097/BOT.0b013e31817279b8, PII 0000513120080500000005
-
Estes C, Rhee P, Shrader MW, et al. Biomechanical strength of the Peri-Loc proximal tibial plate: A comparison of all-locked vs hybrid locked/nonlocked screw configurations. J Orthop Trauma. 2008;22(5):312-6. (Pubitemid 351630244)
-
(2008)
Journal of Orthopaedic Trauma
, vol.22
, Issue.5
, pp. 312-316
-
-
Estes, C.1
Rhee, P.2
Shrader, M.W.3
Csavina, K.4
Jacofsky, M.C.5
Jacofsky, D.J.6
-
70
-
-
33748453701
-
Hybrid locked plating of osteoporotic fractures of the humerus
-
DOI 10.2106/JBJS.E.00893
-
Gardner MJ, Griffith MH, Demetrakopoulos D, et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg [Am]. 2006;88(9):1962-7. (Pubitemid 44352742)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.9
, pp. 1962-1967
-
-
Gardner, M.J.1
Griffith, M.H.2
Demetrakopoulos, D.3
Brophy, R.H.4
Grose, A.5
Helfet, D.L.6
Lorich, D.G.7
-
71
-
-
77649130282
-
How much do locked screws add to the fixation of "hybrid" plate constructs in osteoporotic bone?
-
Freeman AL, Tornetta III P, Schmidt A, et al. How much do locked screws add to the fixation of "hybrid" plate constructs in osteoporotic bone? J Orthop Trauma. 2010;24(3):163-9.
-
(2010)
J Orthop Trauma.
, vol.24
, Issue.3
, pp. 163-169
-
-
Freeman, A.L.1
Tornetta III, P.2
Schmidt, A.3
-
72
-
-
77955866490
-
Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis
-
Doornink J, Fitzpatrick DC, Boldhaus S, et al. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis. J Trauma. 2010;69(2):411-7.
-
(2010)
J Trauma.
, vol.69
, Issue.2
, pp. 411-417
-
-
Doornink, J.1
Fitzpatrick, D.C.2
Boldhaus, S.3
-
73
-
-
77950648564
-
Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate?
-
Streubel PN, Gardner MJ, Morshed S, et al. Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate? J Bone Joint Surg Br. 2010;92 (4):527-34.
-
(2010)
J Bone Joint Surg Br.
, vol.92
, Issue.4
, pp. 527-534
-
-
Streubel, P.N.1
Gardner, M.J.2
Morshed, S.3
-
74
-
-
33646843548
-
Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty
-
DOI 10.1097/00005131-200603000-00005, PII 0000513120060300000005
-
Ricci WM, Loftus T, Cox C, et al. Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty. J Orthop Trauma. 2006;20(3):190-6. (Pubitemid 44315027)
-
(2006)
Journal of Orthopaedic Trauma
, vol.20
, Issue.3
, pp. 190-196
-
-
Ricci, W.M.1
Loftus, T.2
Cox, C.3
Borrelli, J.4
-
75
-
-
84858800145
-
Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate
-
Kobbe P, Hockertz I, Sellei RM, et al. Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate. Int Orthopaed. 2012;36(1):159-64.
-
(2012)
Int Orthopaed.
, vol.36
, Issue.1
, pp. 159-164
-
-
Kobbe, P.1
Hockertz, I.2
Sellei, R.M.3
-
76
-
-
77955667477
-
Clinical results for minimally invasive locked plating of proximal humerus fractures
-
Roderer G, Erhardt J, Graf M, et al. Clinical results for minimally invasive locked plating of proximal humerus fractures. J Orthop Trauma. 2010;24(7):400-6.
-
(2010)
J Orthop Trauma.
, vol.24
, Issue.7
, pp. 400-406
-
-
Roderer, G.1
Erhardt, J.2
Graf, M.3
-
77
-
-
77950488578
-
Minimally invasive locked plating of distal tibia fractures is safe and effective
-
Ronga M, Longo UG, Maffulli N. Minimally invasive locked plating of distal tibia fractures is safe and effective. Clin Orthop. 2010;468(4):975-82.
-
(2010)
Clin Orthop.
, vol.468
, Issue.4
, pp. 975-982
-
-
Ronga, M.1
Longo, U.G.2
Maffulli, N.3
-
78
-
-
67650576430
-
Fixation of distal femoral fractures with the Less Invasive Stabilization System: A minimally invasive treatment with locked fixed-angle screws
-
Kolb W, Guhlmann H, Windisch C, et al. Fixation of distal femoral fractures with the Less Invasive Stabilization System: A minimally invasive treatment with locked fixed-angle screws. J Trauma. 2008;65(6):1425-34.
-
(2008)
J Trauma.
, vol.65
, Issue.6
, pp. 1425-1434
-
-
Kolb, W.1
Guhlmann, H.2
Windisch, C.3
-
79
-
-
52649125805
-
The changing face of orthopaedic trauma: Locked plating and minimally invasive techniques
-
Tejwani NC, Wolinsky P. The changing face of orthopaedic trauma: Locked plating and minimally invasive techniques. Instr Course Lect. 2008;57:3-9.
-
(2008)
Instr Course Lect.
, vol.57
, pp. 3-9
-
-
Tejwani, N.C.1
Wolinsky, P.2
-
81
-
-
4644222787
-
Biomechanics of locked plates and screws
-
DOI 10.1097/00005131-200409000-00003
-
Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488-93. (Pubitemid 39294978)
-
(2004)
Journal of Orthopaedic Trauma
, vol.18
, Issue.8
, pp. 488-493
-
-
Egol, K.A.1
Kubiak, E.N.2
Fulkerson, E.3
Kummer, F.J.4
Koval, K.J.5
-
82
-
-
0142168925
-
Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
-
Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury. 2003;34 Suppl 2:B11-9.
-
(2003)
Injury.
, vol.34
, Issue.SUPPL. 2
-
-
Stoffel, K.1
Dieter, U.2
Stachowiak, G.3
-
83
-
-
77649143635
-
Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation
-
Lujan TJ, Henderson CE, Madey SM, et al. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156-62.
-
(2010)
J Orthop Trauma.
, vol.24
, Issue.3
, pp. 156-162
-
-
Lujan, T.J.1
Henderson, C.E.2
Madey, S.M.3
-
84
-
-
79959539205
-
2010 mid-America Orthopaedic Association Physician in Training Award: Healing complications are common after locked plating for distal femur fractures
-
Henderson CE, Lujan TJ, Kuhl LL, et al. 2010 mid-America Orthopaedic Association Physician in Training Award: Healing complications are common after locked plating for distal femur fractures. Clin Orthop. 2011;469(6):1757-65.
-
(2011)
Clin Orthop.
, vol.469
, Issue.6
, pp. 1757-1765
-
-
Henderson, C.E.1
Lujan, T.J.2
Kuhl, L.L.3
-
85
-
-
4344613283
-
Systemic and local ibandronate enhance screw fixation
-
DOI 10.1016/j.orthres.2003.12.015, PII S0736026604000087
-
Skoglund B, Holmertz J, Aspenberg P. Systemic and local ibandronate enhance screw fixation. J Orthop Res. 2004;22(5):1108-13. (Pubitemid 39145130)
-
(2004)
Journal of Orthopaedic Research
, vol.22
, Issue.5
, pp. 1108-1113
-
-
Skoglund, B.1
Holmertz, J.2
Aspenberg, P.3
-
86
-
-
81155159704
-
Optimising implant anchorage (augmentation) during fixation of osteoporotic fractures: Is there a role for bone-graft substitutes?
-
Larsson S, Procter P. Optimising implant anchorage (augmentation) during fixation of osteoporotic fractures: Is there a role for bone-graft substitutes? Injury. 2011;42 Suppl 2:S72-6.
-
(2011)
Injury
, vol.42
, Issue.SUPPL. 2
-
-
Larsson, S.1
Procter, P.2
-
87
-
-
77951058248
-
Teriparatide may accelerate healing in delayed unions of type III odontoid fractures: A report of 3 cases
-
Rubery PT, Bukata SV. Teriparatide may accelerate healing in delayed unions of type III odontoid fractures: A report of 3 cases. J Spinal Disord Tech. 2010;23(2):151-5.
-
(2010)
J Spinal Disord Tech.
, vol.23
, Issue.2
, pp. 151-155
-
-
Rubery, P.T.1
Bukata, S.V.2
-
88
-
-
84872183921
-
Delayed short course treatment with teriparatide (PTH(1-34)) improves femoral allograft healing by enhancing intramembranous bone formation at the graft-host junction
-
Takahata M, Schwarz EM, Chen T, et al. Delayed short course treatment with teriparatide (PTH(1-34)) improves femoral allograft healing by enhancing intramembranous bone formation at the graft-host junction. J Bone Miner Res: 2011.
-
(2011)
J Bone Miner Res
-
-
Takahata, M.1
Schwarz, E.M.2
Chen, T.3
-
89
-
-
84861826207
-
Enhanced healing of sacral and pubic insufficiency fractures by teriparatide
-
Wu CC, Wei JC, Hsieh CP, et al. Enhanced healing of sacral and pubic insufficiency fractures by teriparatide. J Rheumatol. 2012;39(6):1306-7.
-
(2012)
J Rheumatol.
, vol.39
, Issue.6
, pp. 1306-1307
-
-
Wu, C.C.1
Wei, J.C.2
Hsieh, C.P.3
-
90
-
-
34548424965
-
Metabolic and endocrine abnormalities in patients with nonunions
-
DOI 10.1097/BOT.0b013e31814d4dc6, PII 0000513120070900000007
-
Brinker MR, O'Connor DP, Monla YT, et al. Metabolic and endocrine abnormalities in patients with nonunions. J Orthop Trauma. 2007;21(8):557-70. (Pubitemid 47367964)
-
(2007)
Journal of Orthopaedic Trauma
, vol.21
, Issue.8
, pp. 557-570
-
-
Brinker, M.R.1
O'Connor, D.P.2
Monla, Y.T.3
Earthman, T.P.4
-
91
-
-
43249115352
-
Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant
-
DOI 10.1097/BOT.0b013e31815b3922, PII 0000513120080300000008
-
Gardner MJ, Boraiah S, Helfet DL, et al. Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J Orthop Trauma. 2008;22(3):195-200. (Pubitemid 351654238)
-
(2008)
Journal of Orthopaedic Trauma
, vol.22
, Issue.3
, pp. 195-200
-
-
Gardner, M.J.1
Boraiah, S.2
Helfet, D.L.3
Lorich, D.G.4
-
92
-
-
34247563357
-
The importance of medial support in locked plating of proximal humerus fractures
-
DOI 10.1097/BOT.0b013e3180333094, PII 0000513120070300000006
-
Gardner MJ, Weil Y, Barker JU, et al. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21(3):185-91. (Pubitemid 46673839)
-
(2007)
Journal of Orthopaedic Trauma
, vol.21
, Issue.3
, pp. 185-191
-
-
Gardner, M.J.1
Weil, Y.2
Barker, J.U.3
Kelly, B.T.4
Helfet, D.L.5
Lorich, D.G.6
-
93
-
-
0036091352
-
Endosteal substitution with an allograft cortical strut in the treatment of a periprosthetic femur fracture: A case report
-
DOI 10.1097/00005131-200205000-00012
-
Konrath GA, Bahler S. Endosteal substitution with an allograft cortical strut in the treatment of a periprosthetic femur fracture: A case report. J Orthop Trauma. 2002;16(5):356-8. (Pubitemid 34520570)
-
(2002)
Journal of Orthopaedic Trauma
, vol.16
, Issue.5
, pp. 356-358
-
-
Konrath, G.A.1
Bahler, S.2
-
94
-
-
0029683183
-
The use of endosteal substitution in the treatment of recalcitrant nonunions of the femur: Report of seven cases
-
Matelic TM, Monroe MT, Mast JW. The use of endosteal substitution in the treatment of recalcitrant nonunions of the femur: Report of 7 cases. J Orthop Trauma. 1996;10(1):1-6. (Pubitemid 126432658)
-
(1996)
Journal of Orthopaedic Trauma
, vol.10
, Issue.1
, pp. 1-6
-
-
Matelic, T.M.1
Monroe, M.T.2
Mast, J.W.3
-
95
-
-
0042198961
-
Fixation of periprosthetic femur fractures: A biomechanical analysis comparing cortical strut allograft plates and conventional metal plates
-
Peters CL, Bachus KN, Davitt JS. Fixation of periprosthetic femur fractures: A biomechanical analysis comparing cortical strut allograft plates and conventional metal plates. Orthopedics. 2003;26(7):695-9. (Pubitemid 36939314)
-
(2003)
Orthopedics
, vol.26
, Issue.7
, pp. 695-699
-
-
Peters, C.L.1
Bachus, K.N.2
Davitt, J.S.3
-
96
-
-
79955949211
-
Revision total hip arthroplasty for a Vancouver type B3 periprosthetic fracture using an allograftcemented stem composite by the telescoping technique
-
e625-68
-
Ogawa H, Ito Y, Takigami I, et al. Revision total hip arthroplasty for a Vancouver type B3 periprosthetic fracture using an allograftcemented stem composite by the telescoping technique. J Arthroplasty. 2011;26(4):665. e625-68.
-
(2011)
J Arthroplasty.
, vol.26
, Issue.4
, pp. 665
-
-
Ogawa, H.1
Ito, Y.2
Takigami, I.3
-
97
-
-
77954694562
-
Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: A mechanical comparison of locking and nonlocking single and dual plating methods
-
Yoo BJ, Beingessner DM, Barei DP. Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: A mechanical comparison of locking and nonlocking single and dual plating methods. J Trauma. 2010;69(1):148-55.
-
(2010)
J Trauma.
, vol.69
, Issue.1
, pp. 148-155
-
-
Yoo, B.J.1
Beingessner, D.M.2
Barei, D.P.3
-
98
-
-
41849129556
-
Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice - A review of the American Board of Orthopaedic Surgery database
-
DOI 10.2106/JBJS.G.00517
-
Anglen JO, Weinstein JN. Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database. J Bone Joint Surg [Am]. 2008;90(4):700-7. (Pubitemid 351499956)
-
(2008)
Journal of Bone and Joint Surgery - Series A
, vol.90
, Issue.4
, pp. 700-707
-
-
Anglen, J.O.1
Weinstein, J.N.2
-
99
-
-
0036512930
-
Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate: A prospective, randomized study
-
Sadowski C, Lubbeke A, Saudan M, et al. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: A prospective, randomized study. J Bone Joint Surg [Am]. 2002;84-A(3):372-81. (Pubitemid 37107707)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.3
, pp. 372-381
-
-
Sadowski, C.1
Lubbeke, A.2
Saudan, M.3
Riand, N.4
Stern, R.5
Hoffmeyer, P.6
-
100
-
-
0030720275
-
Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
-
Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br. 1997;79(6):969-71. (Pubitemid 27499589)
-
(1997)
Journal of Bone and Joint Surgery - Series B
, vol.79
, Issue.6
, pp. 969-971
-
-
Baumgaertner, M.R.1
Solberg, B.D.2
-
101
-
-
0029012764
-
The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
-
Baumgaertner MR, Curtin SL, Lindskog DM, et al. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg [Am]. 1995;77 (7):1058-64.
-
(1995)
J Bone Joint Surg [Am].
, vol.77
, Issue.7
, pp. 1058-1064
-
-
Baumgaertner, M.R.1
Curtin, S.L.2
Lindskog, D.M.3
-
102
-
-
79957863283
-
Biomechanical comparison of tibial nail stability in a proximal third fracture: Do screw quantity and locked, interlocking screws make a difference?
-
Freeman AL, Craig MR, Schmidt AH. Biomechanical comparison of tibial nail stability in a proximal third fracture: Do screw quantity and locked, interlocking screws make a difference? J Orthop Trauma. 2011;25(6):333-9.
-
(2011)
J Orthop Trauma.
, vol.25
, Issue.6
, pp. 333-339
-
-
Freeman, A.L.1
Craig, M.R.2
Schmidt, A.H.3
-
103
-
-
56149088066
-
Operative treatment of ipsilateral noncontiguous unicondylar tibial plateau and shaft fractures: Combining plates and nails
-
Kubiak EN, Camuso MR, Barei DP, et al. Operative treatment of ipsilateral noncontiguous unicondylar tibial plateau and shaft fractures: Combining plates and nails. J Orthop Trauma. 2008;22(8):560-5.
-
(2008)
J Orthop Trauma.
, vol.22
, Issue.8
, pp. 560-565
-
-
Kubiak, E.N.1
Camuso, M.R.2
Barei, D.P.3
-
104
-
-
77955076197
-
Far cortical locking can improve healing of fractures stabilized with locking plates
-
Bottlang M, Lesser M, Koerber J, et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg [Am]. 2010;92(7):1652-60.
-
(2010)
J Bone Joint Surg [Am].
, vol.92
, Issue.7
, pp. 1652-1660
-
-
Bottlang, M.1
Lesser, M.2
Koerber, J.3
-
105
-
-
79551565253
-
Far cortical locking enables flexible fixation with periarticular locking plates
-
Doornink J, Fitzpatrick DC, Madey SM, et al. Far cortical locking enables flexible fixation with periarticular locking plates. J Orthop Trauma. 2011;25 Suppl 1:S29-34.
-
(2011)
J Orthop Trauma.
, vol.25
, Issue.SUPPL. 1
-
-
Doornink, J.1
Fitzpatrick, D.C.2
Madey, S.M.3
-
106
-
-
33748470933
-
The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening: A comparison based on a new torque value index: The fixation index
-
DOI 10.1007/s00402-006-0142-5
-
Placzek R, Ruffer M, Deuretzbacher G, et al. The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening: A comparison based on a new torque value index: The fixation index. Arch Orthop Trauma Surg. 2006;126(6):369-73. (Pubitemid 44349257)
-
(2006)
Archives of Orthopaedic and Trauma Surgery
, vol.126
, Issue.6
, pp. 369-373
-
-
Placzek, R.1
Ruffer, M.2
Deuretzbacher, G.3
Heijens, E.4
Meiss, A.L.5
-
107
-
-
18144371647
-
Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: A pilot study
-
Hasegawa T, Inufusa A, Imai Y, et al. Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: A pilot study. Spine J. 2005;5(3):239-43.
-
(2005)
Spine J.
, vol.5
, Issue.3
, pp. 239-343
-
-
Hasegawa, T.1
Inufusa, A.2
Imai, Y.3
|