메뉴 건너뛰기




Volumn 90, Issue 4, 2008, Pages 700-707

Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice - A review of the American Board of Orthopaedic Surgery database

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLISTER; BONE PLATE; CLINICAL PRACTICE; COMPARATIVE STUDY; CONTROLLED STUDY; DEFORMITY; FEMUR INTERTROCHANTERIC FRACTURE; FOLLOW UP; FRACTURE; FRACTURE FIXATION; HUMAN; INTRAMEDULLARY NAIL; LIGAMENT INJURY; LIMB ISCHEMIA; MAJOR CLINICAL STUDY; NERVE INJURY; NERVE PARALYSIS; OPERATING ROOM PERSONNEL; PATIENT SATISFACTION; POSTOPERATIVE HEMORRHAGE; POSTOPERATIVE INFECTION; POSTOPERATIVE PAIN; PRIORITY JOURNAL; PROSTHESIS FAILURE; PSEUDARTHROSIS; SKIN ULCER; SURGEON; WOUND DEHISCENCE; WOUND HEMORRHAGE; WOUND INFECTION;

EID: 41849129556     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/JBJS.G.00517     Document Type: Article
Times cited : (384)

References (40)
  • 1
    • 84937171000 scopus 로고
    • Trochanteric fractures treated by the sliding screw plate fixation method
    • Clawson DK. Trochanteric fractures treated by the sliding screw plate fixation method. J Trauma. 1964;27:737-52.
    • (1964) J Trauma , vol.27 , pp. 737-752
    • Clawson, D.K.1
  • 2
    • 0000776951 scopus 로고
    • A new principle in the operative treatment of trochanteric fractures of the femur
    • Schumpelick W, Jantzen PM. A new principle in the operative treatment of trochanteric fractures of the femur. J Bone Joint Surg Am. 1955;37:693-8.
    • (1955) J Bone Joint Surg Am , vol.37 , pp. 693-698
    • Schumpelick, W.1    Jantzen, P.M.2
  • 3
    • 0026544624 scopus 로고
    • The Gamma nail for peritrochanteric fractures
    • Halder SC. The Gamma nail for peritrochanteric fractures. J Bone Joint Surg Br. 1992;74:340-4.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 340-344
    • Halder, S.C.1
  • 4
    • 0026504845 scopus 로고
    • Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients
    • Leung KS, So WS, Shen WY, Hui PW. Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg Br. 1992;74:345-51.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 345-351
    • Leung, K.S.1    So, W.S.2    Shen, W.Y.3    Hui, P.W.4
  • 5
    • 85031374751 scopus 로고    scopus 로고
    • Committees on Trauma blue book: a guide to organization, objectives, activities. Chicago: American College of Surgeons; 2007. p 23-9. http://www.facs.org/trauma/publications/bluebook2007.pdf. Accessed September 18, 2007.
    • Committees on Trauma blue book: a guide to organization, objectives, activities. Chicago: American College of Surgeons; 2007. p 23-9. http://www.facs.org/trauma/publications/bluebook2007.pdf. Accessed September 18, 2007.
  • 6
    • 0003489150 scopus 로고
    • Fractures: A history and iconography of their treatment. San Francisco
    • Norman;, The internal fixation of fractures. p
    • Peltier LF. Fractures: a history and iconography of their treatment. San Francisco: Norman; 1990. The internal fixation of fractures. p 114-67.
    • (1990) , pp. 114-167
    • Peltier, L.F.1
  • 7
    • 0018344505 scopus 로고
    • Analysis of six hundred and twenty-two intertrochanteric hip fractures
    • Kyle RF, Gustilo RB, Premer RF. Analysis of six hundred and twenty-two intertrochanteric hip fractures. J Bone Joint Surg Am. 1979;61:216-21.
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 216-221
    • Kyle, R.F.1    Gustilo, R.B.2    Premer, R.F.3
  • 8
    • 0018080358 scopus 로고
    • Internal fixation by the Ender method
    • Corzatt RD, Bosch AV. Internal fixation by the Ender method. JAMA. 1978;240:1366.
    • (1978) JAMA , vol.240 , pp. 1366
    • Corzatt, R.D.1    Bosch, A.V.2
  • 9
    • 0018967967 scopus 로고
    • Closed retrograde intramedullary nailing of peritrochanteric fractures of the femur with a new nail
    • Harris U. Closed retrograde intramedullary nailing of peritrochanteric fractures of the femur with a new nail. J Bone Joint Surg Am. 1980;62:1185-93.
    • (1980) J Bone Joint Surg Am , vol.62 , pp. 1185-1193
    • Harris, U.1
  • 11
    • 0021965571 scopus 로고
    • Hip fractures: Condylocephalic rod versus compression screw
    • Sherk HH, Foster MD. Hip fractures: condylocephalic rod versus compression screw. Clin Orthop Relat Res. 1985;192:255-9.
    • (1985) Clin Orthop Relat Res , vol.192 , pp. 255-259
    • Sherk, H.H.1    Foster, M.D.2
  • 12
    • 0026335169 scopus 로고
    • Pertrochanteric fractures treated with the Gamma nail: Technique and report of early results
    • Davis J, Harris MB, Duval M, D'Ambrosia R. Pertrochanteric fractures treated with the Gamma nail: technique and report of early results. Orthopedics. 1991;14:939-42.
    • (1991) Orthopedics , vol.14 , pp. 939-942
    • Davis, J.1    Harris, M.B.2    Duval, M.3    D'Ambrosia, R.4
  • 13
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • Bridle SH, Patel AD, Bircher M, Calvert PT. Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg Br. 1991;73:330-4.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 14
    • 0026344705 scopus 로고
    • Early experience with the gamma interlocking nail for peritrochanteric fractures of the proximal femur
    • Lindsey RW, Teal P, Probe RA, Rhoads D, Davenport S, Schauder K. Early experience with the gamma interlocking nail for peritrochanteric fractures of the proximal femur. J Trauma. 1991;31:1649-58.
    • (1991) J Trauma , vol.31 , pp. 1649-1658
    • Lindsey, R.W.1    Teal, P.2    Probe, R.A.3    Rhoads, D.4    Davenport, S.5    Schauder, K.6
  • 15
    • 0028412422 scopus 로고
    • The results of a multicenter Italian study on the use of the Gamma nail for the treatment of pertrochanteric and subtrochanteric fractures: A review of 1181 cases
    • Boriani S, De Iure F, Bettelli G, Specchia L, Bungara P, Montanari G, Capelli A, Canella P, Regnoli R, Triscari C. The results of a multicenter Italian study on the use of the Gamma nail for the treatment of pertrochanteric and subtrochanteric fractures: a review of 1181 cases. Chir Organi Mov. 1994;79:193-203.
    • (1994) Chir Organi Mov , vol.79 , pp. 193-203
    • Boriani, S.1    De Iure, F.2    Bettelli, G.3    Specchia, L.4    Bungara, P.5    Montanari, G.6    Capelli, A.7    Canella, P.8    Regnoli, R.9    Triscari, C.10
  • 16
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients
    • Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am. 1998;80:618-30.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 618-630
    • Hardy, D.C.1    Descamps, P.Y.2    Krallis, P.3    Fabeck, L.4    Smets, P.5    Bertens, C.L.6    Delince, P.E.7
  • 17
    • 0027170493 scopus 로고
    • A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
    • Radford PJ, Needoff M, Webb JK. A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Joint Surg Br. 1993;75:789-93.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 18
    • 0036177813 scopus 로고    scopus 로고
    • Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    • Harrington P, Nihal A, Singhania AK, Howell FR. Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury. 2002;33:23-8.
    • (2002) Injury , vol.33 , pp. 23-28
    • Harrington, P.1    Nihal, A.2    Singhania, A.K.3    Howell, F.R.4
  • 19
    • 0029616325 scopus 로고
    • Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    • O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S. Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg. 1995;38:516-20.
    • (1995) Can J Surg , vol.38 , pp. 516-520
    • O'Brien, P.J.1    Meek, R.N.2    Blachut, P.A.3    Broekhuyse, H.M.4    Sabharwal, S.5
  • 21
    • 12444280103 scopus 로고    scopus 로고
    • Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation
    • Pajarinen J, Lindahl J, Michelsson O, Savolainen V, Hirvensalo E. Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation. J Bone Joint Surg Br. 2005;87:76-81.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 76-81
    • Pajarinen, J.1    Lindahl, J.2    Michelsson, O.3    Savolainen, V.4    Hirvensalo, E.5
  • 22
    • 0035203345 scopus 로고    scopus 로고
    • Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: Preliminary results
    • Dujardin FH, Benez C, Polle G, Alain J, Biga N, Thomine JM. Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: preliminary results. J Orthop Trauma. 2001;15:401-6.
    • (2001) J Orthop Trauma , vol.15 , pp. 401-406
    • Dujardin, F.H.1    Benez, C.2    Polle, G.3    Alain, J.4    Biga, N.5    Thomine, J.M.6
  • 23
    • 0031866341 scopus 로고    scopus 로고
    • Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - a randomised prospective trial
    • Park SR, Kang JS, Kim HS, Lee WH, Kim YH. Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - a randomised prospective trial. Int Orthop. 1998;22:157-60.
    • (1998) Int Orthop , vol.22 , pp. 157-160
    • Park, S.R.1    Kang, J.S.2    Kim, H.S.3    Lee, W.H.4    Kim, Y.H.5
  • 24
    • 0028307825 scopus 로고
    • Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients
    • Aune AK, Ekeland A, Odegaard B, Grøgaard B, Alho A. Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand. 1994;65:127-30.
    • (1994) Acta Orthop Scand , vol.65 , pp. 127-130
    • Aune, A.K.1    Ekeland, A.2    Odegaard, B.3    Grøgaard, B.4    Alho, A.5
  • 25
    • 0028866619 scopus 로고
    • Comparison of dynamic hip screw and gamma nail: A prospective, randomized, controlled trial
    • Butt MS, Krikler SJ, Nafie S, Ali MS. Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury. 1995;26:615-8.
    • (1995) Injury , vol.26 , pp. 615-618
    • Butt, M.S.1    Krikler, S.J.2    Nafie, S.3    Ali, M.S.4
  • 26
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Strømsøe K. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma. 1998;12:241-8.
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Strømsøe, K.6
  • 27
    • 33646114311 scopus 로고    scopus 로고
    • The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases
    • Crawford CH, Malkani AL, Cordray S, Roberts CS, Sligar W. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases. J Trauma. 2006;60:325-9.
    • (2006) J Trauma , vol.60 , pp. 325-329
    • Crawford, C.H.1    Malkani, A.L.2    Cordray, S.3    Roberts, C.S.4    Sligar, W.5
  • 28
    • 0031924186 scopus 로고    scopus 로고
    • Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    • Baumgaertner MR, Curtin SL, Lindskog DM. Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res. 1998;348:87-94.
    • (1998) Clin Orthop Relat Res , vol.348 , pp. 87-94
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 29
    • 85044707036 scopus 로고    scopus 로고
    • Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2005;4:CD000093.
    • Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2005;4:CD000093.
  • 30
    • 0031924068 scopus 로고    scopus 로고
    • Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures
    • Watson JT, Moed BR, Cramer KE, Karges DE. Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures. Clin Orthop Relat Res. 1998;348:79-86.
    • (1998) Clin Orthop Relat Res , vol.348 , pp. 79-86
    • Watson, J.T.1    Moed, B.R.2    Cramer, K.E.3    Karges, D.E.4
  • 31
    • 17144467492 scopus 로고    scopus 로고
    • Reverse obliquity fractures of the intertrochanteric region of the femur
    • Haidukewych GJ, Israel TA, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am. 2001;83:643-50.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 643-650
    • Haidukewych, G.J.1    Israel, T.A.2    Berry, D.J.3
  • 32
    • 14644444624 scopus 로고    scopus 로고
    • Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw
    • Kyle RF, Ellis TJ, Templeman DC. Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw. J Orthop Trauma. 2005;19:1-4.
    • (2005) J Orthop Trauma , vol.19 , pp. 1-4
    • Kyle, R.F.1    Ellis, T.J.2    Templeman, D.C.3
  • 33
    • 0027327133 scopus 로고
    • A biomechanical evaluation of an intramedullary fixation device for intertrochanteric fractures
    • Flahiff CM, Nelson CL, Gruenwald JM, Hollis JM. A biomechanical evaluation of an intramedullary fixation device for intertrochanteric fractures. J Trauma. 1993;35:23-7.
    • (1993) J Trauma , vol.35 , pp. 23-27
    • Flahiff, C.M.1    Nelson, C.L.2    Gruenwald, J.M.3    Hollis, J.M.4
  • 34
    • 2042421503 scopus 로고    scopus 로고
    • Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: A cadaver study
    • Bong MR, Patel V, Iesaka K, Egol KA, Kummer FJ, Koval KJ. Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: a cadaver study. J Trauma. 2004;56:791-4.
    • (2004) J Trauma , vol.56 , pp. 791-794
    • Bong, M.R.1    Patel, V.2    Iesaka, K.3    Egol, K.A.4    Kummer, F.J.5    Koval, K.J.6
  • 35
    • 17644364373 scopus 로고    scopus 로고
    • Trochanteric gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail
    • Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB. Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma. 2005;19:229-33.
    • (2005) J Orthop Trauma , vol.19 , pp. 229-233
    • Utrilla, A.L.1    Reig, J.S.2    Muñoz, F.M.3    Tufanisco, C.B.4
  • 36
    • 14644446095 scopus 로고    scopus 로고
    • Evidence-Based Orthopaedic Trauma Working Group. Unstable pertrochanteric femoral fractures
    • Kregor PJ, Obremskey WT, Kreder HJ, Swiontkowski MF; Evidence-Based Orthopaedic Trauma Working Group. Unstable pertrochanteric femoral fractures. J Orthop Trauma. 2005;19:63-6.
    • (2005) J Orthop Trauma , vol.19 , pp. 63-66
    • Kregor, P.J.1    Obremskey, W.T.2    Kreder, H.J.3    Swiontkowski, M.F.4
  • 37
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures
    • Jones HW, Johnston P, Parker M. Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures. Int Orthop. 2006;30:69-78.
    • (2006) Int Orthop , vol.30 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 38
    • 33845782824 scopus 로고    scopus 로고
    • A new intramedullary nail device for the treatment of intertrochanteric hip fractures: Perioperative experience
    • Bienkowski P, Reindl R, Berry GK, Iakoub E, Harvey EJ. A new intramedullary nail device for the treatment of intertrochanteric hip fractures: Perioperative experience. J Trauma. 2006;61:1458-62.
    • (2006) J Trauma , vol.61 , pp. 1458-1462
    • Bienkowski, P.1    Reindl, R.2    Berry, G.K.3    Iakoub, E.4    Harvey, E.J.5
  • 39
    • 0036064177 scopus 로고    scopus 로고
    • Pertrochanteric fractures: Is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail
    • Saudan M, Lübbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P. Pertrochanteric fractures: is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma. 2002;16:386-93.
    • (2002) J Orthop Trauma , vol.16 , pp. 386-393
    • Saudan, M.1    Lübbeke, A.2    Sadowski, C.3    Riand, N.4    Stern, R.5    Hoffmeyer, P.6
  • 40
    • 85031376668 scopus 로고    scopus 로고
    • Center for Medicare and Medicaid Services
    • Accessed 2007 Oct 15
    • US Department of Health and Human Services. Center for Medicare and Medicaid Services. Physician fee schedule relative value files. http://www.cms.hhs.gov/PhysicianFeeSched/. Accessed 2007 Oct 15.
    • Physician fee schedule relative value files


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.