-
1
-
-
0020366610
-
Dynamic volume imaging of moving organs
-
Robb RA, Sinak LJ, Hoffman EA, Kinsey JH, Harris LD, Ritman EL. Dynamic volume imaging of moving organs. J Med Syst 1982; 6: 539-554.
-
(1982)
J Med Syst
, vol.6
, pp. 539-554
-
-
Robb, R.A.1
Sinak, L.J.2
Hoffman, E.A.3
Kinsey, J.H.4
Harris, L.D.5
Ritman, E.L.6
-
2
-
-
0033156083
-
Development of a compact computed tomographic apparatus for dental use
-
Arai Y, Tammisalo E, Iwai K, Hashimoto K, Shinoda K. Development of a compact computed tomographic apparatus for dental use. Dentomaxillofac Radiol 1999; 28: 245-248.
-
(1999)
Dentomaxillofac Radiol
, vol.28
, pp. 245-248
-
-
Arai, Y.1
Tammisalo, E.2
Iwai, K.3
Hashimoto, K.4
Shinoda, K.5
-
3
-
-
0038755182
-
A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine
-
Hashimoto K, Arai Y, Iwai K, Araki M, Kawashima S, Terakado M. A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003; 95: 371-377.
-
(2003)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.95
, pp. 371-377
-
-
Hashimoto, K.1
Arai, Y.2
Iwai, K.3
Araki, M.4
Kawashima, S.5
Terakado, M.6
-
4
-
-
0642310337
-
Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit
-
Ludlow J, Davies-Ludlow L, Brooks S. Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit. Dentomaxillofac Radiol 2003; 32: 229-234.
-
(2003)
Dentomaxillofac Radiol
, vol.32
, pp. 229-234
-
-
Ludlow, J.1
Davies-Ludlow, L.2
Brooks, S.3
-
5
-
-
5044251144
-
Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography
-
Schulze D, Heiland M, Thurmann H, Adam G. Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol 2004; 33: 83-86.
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 83-86
-
-
Schulze, D.1
Heiland, M.2
Thurmann, H.3
Adam, G.4
-
6
-
-
33746041477
-
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
-
Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 2006; 35: 219-226.
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 219-226
-
-
Ludlow, J.B.1
Davies-Ludlow, L.E.2
Brooks, S.L.3
Howerton, W.B.4
-
7
-
-
0032240404
-
A new volumetric CT machine for dental imaging based on the conebeam technique: Preliminary results
-
Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the conebeam technique: preliminary results. Eur Radiol 1998; 8: 1558-1564.
-
(1998)
Eur Radiol
, vol.8
, pp. 1558-1564
-
-
Mozzo, P.1
Procacci, C.2
Tacconi, A.3
Martini, P.T.4
Andreis, I.A.5
-
8
-
-
0642365211
-
Cone beam computed tomography in craniofacial imaging
-
Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthod Craniofac Res 2003; 6: 31-36.
-
(2003)
Orthod Craniofac Res
, vol.6
, pp. 31-36
-
-
Sukovic, P.1
-
9
-
-
60749125756
-
The basics of maxillofacial cone beam computed tomography
-
Farman AG, Scarfe WC. The basics of maxillofacial cone beam computed tomography. Semin Orthod 2009; 15: 2-13.
-
(2009)
Semin Orthod
, vol.15
, pp. 2-13
-
-
Farman, A.G.1
Scarfe, W.C.2
-
11
-
-
77956204072
-
Deriving hounsfield units using grey levels in cone beam computed tomography
-
Mah P, Reeves TE, McDavid WD. Deriving Hounsfield units using grey levels in cone beam computed tomography. Dentomaxillofac Radiol 2010; 39: 323-335.
-
(2010)
Dentomaxillofac Radiol
, vol.39
, pp. 323-335
-
-
Mah, P.1
Reeves, T.E.2
McDavid, W.D.3
-
12
-
-
78651085661
-
Deriving Hounsfield units from the grey scale of a CBCT?
-
Bryant J. Deriving Hounsfield units from the grey scale of a CBCT? Dentomaxillofac Radiol 2011; 40: 65.
-
(2011)
Dentomaxillofac Radiol
, vol.40
, pp. 65
-
-
Bryant, J.1
-
13
-
-
54849437519
-
Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system
-
Bryant JA, Drage NA, Richmond S. Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system. Dentomaxillofac Radiol 2008; 37: 365-374.
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 365-374
-
-
Bryant, J.A.1
Drage, N.A.2
Richmond, S.3
-
14
-
-
59649097468
-
Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: An in vitro study
-
Katsumata A, Hirukawa A, Okumura S, Naitoh M, Fujishita M, Ariji E, et al. Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 420-425.
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.107
, pp. 420-425
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
Naitoh, M.4
Fujishita, M.5
Ariji, E.6
-
15
-
-
36148937224
-
Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography
-
Katsumata A, Hirukawa A, Okumura S, Naitoh M, Fujishita M, Ariji E, et al. Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 829-836.
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 829-836
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
Naitoh, M.4
Fujishita, M.5
Ariji, E.6
-
17
-
-
0035053536
-
Effect of scattered radiation on image noise in cone beam CT
-
Endo M, Tsunoo T, Nakamori N, Yoshida K. Effect of scattered radiation on image noise in cone beam CT. Med Phys 2001; 28: 469-474.
-
(2001)
Med Phys
, vol.28
, pp. 469-474
-
-
Endo, M.1
Tsunoo, T.2
Nakamori, N.3
Yoshida, K.4
-
18
-
-
4143136222
-
Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRayTM): System configuration and physical properties
-
Araki K, Maki K, Seki K, Sakamaki K, Harata Y, Sakaino R, et al. Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRayTM): system configuration and physical properties. Dentomaxillofac Radiol 2004; 33: 51-59.
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 51-59
-
-
Araki, K.1
Maki, K.2
Seki, K.3
Sakamaki, K.4
Harata, Y.5
Sakaino, R.6
-
20
-
-
14244264415
-
Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
-
Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol 2004; 33: 291-294.
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 291-294
-
-
Lascala, C.A.1
Panella, J.2
Marques, M.M.3
-
21
-
-
40549094662
-
Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
-
Loubele M, Van Assche N, Carpentier K, Maes F, Jacobs R, van Steenberghe D, et al. Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 105: 512-518.
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.105
, pp. 512-518
-
-
Loubele, M.1
Van, A.N.2
Carpentier, K.3
Maes, F.4
Jacobs, R.5
Van, S.D.6
-
24
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
25
-
-
0028791287
-
Comparing methods of measurement: Why plotting difference against standard method is misleading
-
Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995; 346: 1085-1087.
-
(1995)
Lancet
, vol.346
, pp. 1085-1087
-
-
Bland, J.M.1
Altman, D.G.2
-
26
-
-
36248992966
-
Cervical soft tissue imaging using a mobile CBCT scanner with a flat panel detector in comparison with corresponding CT and MRI data sets
-
Heiland M, Pohlenz P, Blessmann M, Habermann CR, Oesterhelweg L, Begemann PC, et al. Cervical soft tissue imaging using a mobile CBCT scanner with a flat panel detector in comparison with corresponding CT and MRI data sets. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 814-820.
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 814-820
-
-
Heiland, M.1
Pohlenz, P.2
Blessmann, M.3
Habermann, C.R.4
Oesterhelweg, L.5
Begemann, P.C.6
-
27
-
-
38949173479
-
Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
-
Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 2008; 37: 10-107.
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 10-107
-
-
Suomalainen, A.1
Vehmas, T.2
Kortesniemi, M.3
Robinson, S.4
Peltola, J.5
-
28
-
-
77955850723
-
A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT): Part I. On subjective image quality
-
Liang X, Jacobs R, Hassan B, Li L, Pauwels R, Corpas L, et al. A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT): Part I. On subjective image quality. Eur Radiol 2010; 75: 265-269.
-
(2010)
Eur Radiol
, vol.75
, pp. 265-269
-
-
Liang, X.1
Jacobs, R.2
Hassan, B.3
Li, L.4
Pauwels, R.5
Corpas, L.6
-
29
-
-
77955554713
-
A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT). Part II: On 3D model accuracy
-
Liang X, Lambrichts I, Sun Y, Denis K, Hassan B, Li L, et al. A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT). Part II: On 3D model accuracy. Eur Radiol 2010; 75: 270-274.
-
(2010)
Eur Radiol
, vol.75
, pp. 270-274
-
-
Liang, X.1
Lambrichts, I.2
Sun, Y.3
Denis, K.4
Hassan, B.5
Li, L.6
-
30
-
-
33746225361
-
Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: A pilot study
-
Loubele M, Maes F, Schutyser F, Marchal G, Jacobs R, Suetens P. Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2006; 102: 225-234.
-
(2006)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.102
, pp. 225-234
-
-
Loubele, M.1
Maes, F.2
Schutyser, F.3
Marchal, G.4
Jacobs, R.5
Suetens, P.6
-
31
-
-
33745791393
-
Comparison of image performance between conebeam computed tomography for dental use and four-row multidetector helical CT
-
Hashimoto K, Kawashima S, Araki M, Iwai K, Sawada K, Akiyama Y. Comparison of image performance between conebeam computed tomography for dental use and four-row multidetector helical CT. J Oral Sci 2006; 48: 27-34.
-
(2006)
J Oral Sci
, vol.48
, pp. 27-34
-
-
Hashimoto, K.1
Kawashima, S.2
Araki, M.3
Iwai, K.4
Sawada, K.5
Akiyama, Y.6
-
32
-
-
78751532284
-
A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
-
Al-Ekrish AA, Ekram M. A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011; 40: 67-75.
-
(2011)
Dentomaxillofac Radiol
, vol.40
, pp. 67-75
-
-
Al-Ekrish, A.A.1
Ekram, M.2
-
33
-
-
34648830600
-
Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging
-
Mischkowski RA, Pulsfort R, Ritter L, Neugebauer J, Brochhagen HG, Keeve E, et al. Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 551-559.
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 551-559
-
-
Mischkowski, R.A.1
Pulsfort, R.2
Ritter, L.3
Neugebauer, J.4
Brochhagen, H.G.5
Keeve, E.6
-
34
-
-
34547358852
-
A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT
-
Loubele M, Guerrero ME, Jacobs R, Suetens P, van Steenberghe D. A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT. Int J Oral Maxillofac Implants 2007; 22: 446-454.
-
(2007)
Int J Oral Maxillofac Implants
, vol.22
, pp. 446-454
-
-
Loubele, M.1
Guerrero, M.E.2
Jacobs, R.3
Suetens, P.4
Van, S.D.5
-
35
-
-
69249102664
-
Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
-
Suomalainen A, Kiljunen T, Kaser Y, Peltola J, Kortesniemi M. Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners. Dentomaxillofac Radiol 2009; 38: 367-378.
-
(2009)
Dentomaxillofac Radiol
, vol.38
, pp. 367-378
-
-
Suomalainen, A.1
Kiljunen, T.2
Kaser, Y.3
Peltola, J.4
Kortesniemi, M.5
-
36
-
-
77955007139
-
Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
-
Carrafiello G, Dizonno M, Colli V, Strocchi S, Pozzi Taubert S, Leonardi A, et al. Comparative study of jaws with multislice computed tomography and cone-beam computed tomography. Radiol Med 2010; 115: 600-611.
-
(2010)
Radiol Med
, vol.115
, pp. 600-611
-
-
Carrafiello, G.1
Dizonno, M.2
Colli, V.3
Strocchi, S.4
Pozzi, T.S.5
Leonardi, A.6
-
37
-
-
72049104773
-
Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures
-
Naitoh M, Nakahara K, Suenaga Y, Gotoh K, Kondo S, Ariji E. Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e25-31.
-
(2010)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.109
-
-
Naitoh, M.1
Nakahara, K.2
Suenaga, Y.3
Gotoh, K.4
Kondo, S.5
Ariji, E.6
-
38
-
-
34249857538
-
Overcoming artifacts from metallic orthopedic implants at highfield- strength MR imaging and multi-detector CT1
-
Lee M-J, Kim S, Lee S-A, Song H-T, Huh Y-M, Kim D-H, et al. Overcoming artifacts from metallic orthopedic implants at highfield- strength MR imaging and multi-detector CT1. Radiographics 2007; 27: 791-803.
-
(2007)
Radiographics
, vol.27
, pp. 791-803
-
-
Lee, M.-J.1
Kim, S.2
Lee, S.-A.3
Song, H.-T.4
Huh, Y.-M.5
Kim, D.-H.6
-
39
-
-
0035061739
-
Dental CT imaging: A look at the jaw
-
Abrahams JJ. Dental CT imaging: a look at the jaw. Radiology 2001; 219: 334-345.
-
(2001)
Radiology
, vol.219
, pp. 334-345
-
-
Abrahams, J.J.1
-
41
-
-
34347238633
-
Beam hardening artefacts occur in dental implant scans with the newtom cone beam CT but not with the dental 4-row multidetector CT
-
Draenert FG, Coppenrath E, Herzog P, Muller S, Mueller-Lisse UG. Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT. Dentomaxillofac Radiol 2007; 36: 198-203.
-
(2007)
Dentomaxillofac Radiol
, vol.36
, pp. 198-203
-
-
Draenert, F.G.1
Coppenrath, E.2
Herzog, P.3
Muller, S.4
Mueller-Lisse, U.G.5
-
42
-
-
33646570509
-
Osseous abnormalities of the mandibular condyle: Diagnostic reliability of cone beam computed tomography compared with helical computed tomography based on an autopsy material
-
Honda K, Larheim TA, Maruhashi K, Matsumoto K, Iwai K. Osseous abnormalities of the mandibular condyle: diagnostic reliability of cone beam computed tomography compared with helical computed tomography based on an autopsy material. Dentomaxillofac Radiol 2006; 35: 152-157.
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 152-157
-
-
Honda, K.1
Larheim, T.A.2
Maruhashi, K.3
Matsumoto, K.4
Iwai, K.5
-
43
-
-
57449091507
-
Soft tissue cone-beam computed tomography: A novel method for the measurement of gingival tissue and the dimensions of the dentogingival unit
-
discussion 74
-
Januário AL, Barriviera M, Duarte WR. Soft tissue cone-beam computed tomography: a novel method for the measurement of gingival tissue and the dimensions of the dentogingival unit. J Esthet Restor Dent 2008; 20: 366-373; discussion 74.
-
(2008)
J Esthet Restor Dent
, vol.20
, pp. 366-373
-
-
Januário, A.L.1
Barriviera, M.2
Duarte, W.R.3
-
44
-
-
68049137472
-
A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography
-
Barriviera M, Duarte WR, Januario AL, Faber J, Bezerra AC. A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography. J Clin Periodontol 2009; 36: 564-568.
-
(2009)
J Clin Periodontol
, vol.36
, pp. 564-568
-
-
Barriviera, M.1
Duarte, W.R.2
Januario, A.L.3
Faber, J.4
Bezerra, A.C.5
-
45
-
-
80052220435
-
Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography
-
Fourie Z, Damstra J, Gerrits PO, Ren Y. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography. Cleft Palate Craniofac J 2011; 48: 623-630.
-
(2011)
Cleft Palate Craniofac J
, vol.48
, pp. 623-630
-
-
Fourie, Z.1
Damstra, J.2
Gerrits, P.O.3
Ren, Y.4
-
46
-
-
77953137374
-
Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography
-
Fourie Z, Damstra J, Gerrits PO, Ren Y. Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography. Forensic Sci Int 2010; 199: 9-14.
-
(2010)
Forensic Sci Int
, vol.199
, pp. 9-14
-
-
Fourie, Z.1
Damstra, J.2
Gerrits, P.O.3
Ren, Y.4
-
48
-
-
0031068809
-
The thickness of masticatory mucosa in the human hard palate and tuberosity as potential donor sites for ridge augmentation procedures
-
Studer SP, Allen EP, Rees TC, Kouba A. The thickness of masticatory mucosa in the human hard palate and tuberosity as potential donor sites for ridge augmentation procedures. J Periodontol 1997; 68: 145-151.
-
(1997)
J Periodontol
, vol.68
, pp. 145-151
-
-
Studer, S.P.1
Allen, E.P.2
Rees, T.C.3
Kouba, A.4
-
49
-
-
33745841175
-
Periodontal status of mandibular central incisors after orthodontic proclination in adults
-
Yared KFG, Zenobio EG, Pacheco W. Periodontal status of mandibular central incisors after orthodontic proclination in adults. Am J Orthod Dentofacial Orthop 2006; 130: 6.e1-6.e8.
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.130
-
-
Yared, K.F.G.1
Zenobio, E.G.2
Pacheco, W.3
-
53
-
-
58149302303
-
Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography
-
de Oliveira AEF, Cevidanes LHS, Phillips C, Motta A, Burke B, Tyndall D. Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 256-265.
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.107
, pp. 256-265
-
-
De Oliveira, A.E.F.1
Cevidanes, L.H.S.2
Phillips, C.3
Motta, A.4
Burke, B.5
Tyndall, D.6
-
54
-
-
77950064191
-
Formalin fixation could interfere with the clinical assessment of the tumor-free margin in tumor surgery: Magnetic resonance imaging-based study
-
Docquier PL, Paul L, Cartiaux O, Lecouvet F, Dufrane D, Delloye C, et al. Formalin fixation could interfere with the clinical assessment of the tumor-free margin in tumor surgery: magnetic resonance imaging-based study. Oncology 2010; 78: 115-124.
-
(2010)
Oncology
, vol.78
, pp. 115-124
-
-
Docquier, P.L.1
Paul, L.2
Cartiaux, O.3
Lecouvet, F.4
Dufrane, D.5
Delloye, C.6
-
55
-
-
0019765325
-
Physiological evidence that periodontal collagen in the rat exists as fibres prior to histological fixation
-
Burn-Murdoch RA, Tyler DW. Physiological evidence that periodontal collagen in the rat exists as fibres prior to histological fixation. Arch Oral Biol 1981; 26: 995-999.
-
(1981)
Arch Oral Biol
, vol.26
, pp. 995-999
-
-
Burn-Murdoch, R.A.1
Tyler, D.W.2
-
56
-
-
80052586182
-
Histomorphometric comparison after fixation with formaldehyde or glyoxal
-
Wang Y, Lee K, Pai S, Ledoux W. Histomorphometric comparison after fixation with formaldehyde or glyoxal. Biotech Histochem 2011; 86: 359-365.
-
(2011)
Biotech Histochem
, vol.86
, pp. 359-365
-
-
Wang, Y.1
Lee, K.2
Pai, S.3
Ledoux, W.4
-
57
-
-
78049437472
-
Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone
-
Stefan U, Michael B, Werner S. Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone. Bone 2010; 47: 1048-1053.
-
(2010)
Bone
, vol.47
, pp. 1048-1053
-
-
Stefan, U.1
Michael, B.2
Werner, S.3
-
58
-
-
0022714231
-
Considerations in the statistical analysis of clinical trials in periodontitis
-
Imrey PB. Considerations in the statistical analysis of clinical trials in periodontitis. J Clin Periodontol 1986; 13: 517-532.
-
(1986)
J Clin Periodontol
, vol.13
, pp. 517-532
-
-
Imrey, P.B.1
|