메뉴 건너뛰기




Volumn 27, Issue 10, 2012, Pages 621-641

Availability of yttrium-90 from strontium-90: A nuclear medicine perspective

Author keywords

90Sr 90Y generator; hepatocellular carcinoma; neuroendocrine tumors; non Hodgkins lymphoma (NHL); radionuclide therapy; rheumatoid arthritis; somatostatin receptors; Yttrium 90

Indexed keywords

ALPHA FETOPROTEIN MONOCLONAL ANTIBODY Y 90; ANGIOPEPTIN Y 90; AVIDIN Y 90; BIOTIN Y 90; BISPECIFIC ANTIBODY Y 90; BOMBESIN Y 90; CARCINOEMBRYONIC ANTIGEN MONOCLONAL ANTIBODY Y 90; CD20 ANTIGEN; CLIVATUZUMAB TETRAXETAN Y 90; EPRATUZUMAB Y 90; GLUCOSE REGULATED PROTEIN DERIVATIVE Y 90; IBRITUMOMAB TIUXETAN; IODINE 131; LUTETIUM 177; MICROSPHERE; MONOCLONAL ANTIBODY; RADIOISOTOPE; RADIOPHARMACEUTICAL AGENT; RHENIUM 188; RITUXIMAB; SAMARIUM 153; SIR SPHERES; SOMATOSTATIN RECEPTOR; STRONTIUM 90; THERA SPERE; TRACE METAL; UNCLASSIFIED DRUG; URANIUM 235; YTTRIUM 86; YTTRIUM 90; YTTRIUM CITRATE Y 90; YTTRIUM SILICATE Y 90; ZIRCONIUM 90;

EID: 84870774227     PISSN: 10849785     EISSN: 15578852     Source Type: Journal    
DOI: 10.1089/cbr.2012.1285     Document Type: Review
Times cited : (72)

References (177)
  • 1
    • 0346458487 scopus 로고    scopus 로고
    • Targeted radionuclide therapy for neuroendocrinetumours
    • Lewington VJ. Targeted radionuclide therapy for neuroendocrinetumours. Endocr-Relat Cancer 2003;10:497.
    • (2003) Endocr-Relat Cancer , vol.10 , pp. 497
    • Lewington, V.J.1
  • 3
    • 84863543386 scopus 로고    scopus 로고
    • Therapeutic radionuclide generators: 90Sr/90Y and188W/188Re generators
    • Vienna: IAEA
    • Therapeutic Radionuclide Generators: 90Sr/90Y and188W/188Re generators. IAEA Technical Report Series No.470, Vienna: IAEA, 2009.
    • (2009) IAEA Technical Report Series No.470
  • 4
    • 77952468760 scopus 로고    scopus 로고
    • Coordinatingradiometals of Copper, Gallium, Indium, Yttrium,and Zirconium for PET and SPECT imaging ofdisease
    • Wadas TJ, Wong EH, Weisman GR, Anderson CJ. Coordinatingradiometals of Copper, Gallium, Indium, Yttrium,and Zirconium for PET and SPECT imaging ofdisease. Chem Rev 2010;110:2858.
    • (2010) Chem Rev , vol.110 , pp. 2858
    • Wadas, T.J.1    Wong, E.H.2    Weisman, G.R.3    Anderson, C.J.4
  • 5
    • 79958191536 scopus 로고    scopus 로고
    • Radiometallatedpeptides for molecular imaging and targetedtherapy
    • Correia JDG, Paulo A, Raposinho PD, Santos I. Radiometallatedpeptides for molecular imaging and targetedtherapy. Dalton Trans 2011;40:6144.
    • (2011) Dalton Trans , vol.40 , pp. 6144
    • Jdg, C.1    Paulo, A.2    Raposinho, P.D.3    Santos, I.4
  • 7
    • 33748423079 scopus 로고    scopus 로고
    • Measurement of fissionneutron spectrum averaged cross sections of some thresholdreactions on zirconium: Production possibility of nocarrier-added 90y in a nuclear reactor
    • Abbasi IA, Zaidi JH, Arif M, et al. Measurement of fissionneutron spectrum averaged cross sections of some thresholdreactions on zirconium: Production possibility of nocarrier-added 90Y in a nuclear reactor. Radiochim Acta2006;94:381.
    • (2006) Radiochim Acta , vol.94 , pp. 381
    • Abbasi, I.A.1    Zaidi, J.H.2    Arif, M.3
  • 8
    • 84861838678 scopus 로고    scopus 로고
    • Production of long lived parent radionuclides for generators:68Ge, 82Sr, 90Sr and 188W
    • Vienna: IAEA
    • Production of Long Lived Parent Radionuclides for Generators:68Ge, 82Sr, 90Sr and 188W. IAEA Radioisotopes andRadiopharmaceuticals Series No. 2, Vienna: IAEA, 2010.
    • (2010) IAEA Radioisotopes AndRadiopharmaceuticals Series No. 2
  • 9
    • 0142026850 scopus 로고    scopus 로고
    • Large-scale purificationof 90Sr from nuclear waste materials for productionof 90Y, a therapeutic medical radioisotope
    • Wester DW, Steele RT, Rinehart DE, et al. Large-scale purificationof 90Sr from nuclear waste materials for productionof 90Y, a therapeutic medical radioisotope. Appl RadiatIsot 2003;59:35.
    • (2003) Appl RadiatIsot , vol.59 , pp. 35
    • Wester, D.W.1    Steele, R.T.2    Rinehart, D.E.3
  • 10
    • 0004080082 scopus 로고    scopus 로고
    • Separation of strontium-90 from purex high level waste and developmentof 90Sr/90Y Generator
    • BARC India
    • Ramanujam A, Dhami PS, Chitnis RR, et al. Separation ofStrontium-90 from PUREX High Level Waste and Developmentof 90Sr/90Y Generator. BARC report 2000/E/009,BARC India, 2000.
    • (2000) BARC Report 2000/E/009
    • Ramanujam, A.1    Dhami, P.S.2    Chitnis, R.R.3
  • 11
    • 0342909890 scopus 로고
    • Large-scale recovery and purificationof fission products
    • Stevenson CE, Mason EA, GreskyAT, eds London: Pergamon Press
    • Beard SJ, Moore RL. Large-scale recovery and purificationof fission products. In: Stevenson CE, Mason EA, GreskyAT, eds., Progress in Nuclear Energy (Series III), ProcessChemistry, Vol. 4. London: Pergamon Press, 1969:645.
    • (1969) Progress in Nuclear Energy (Series III), ProcessChemistry , vol.4 , pp. 645
    • Beard, S.J.1    Moore, R.L.2
  • 14
    • 84870825469 scopus 로고
    • The extraction of strontiumfrom fission product solutions
    • Bruce FR, Fletcher JM, HymanHH, Katz JJ, eds London: Pergamon Press
    • Healy TV, Carter PE, Brown PE. The extraction of strontiumfrom fission product solutions. In: Bruce FR, Fletcher JM, HymanHH, Katz JJ, eds., Progress in Nuclear Energy (Series III),Process Chemistry, Vol. 1. London: Pergamon Press, 1956:363.
    • (1956) Progress in Nuclear Energy (Series III),Process Chemistry , vol.1 , pp. 363
    • Healy, T.V.1    Carter, P.E.2    Brown, P.E.3
  • 17
    • 0026104134 scopus 로고
    • SREX: A new process forthe extraction and recovery of strontium from acidic nuclearwaste streams
    • Horwitz EP, Dietz ML, Fisher DE. SREX: A new process forthe extraction and recovery of strontium from acidic nuclearwaste streams. Solv Extr Ion Exch 1991;9:1.
    • (1991) Solv Extr Ion Exch , vol.9 , pp. 1
    • Horwitz, E.P.1    Dietz, M.L.2    Fisher, D.E.3
  • 19
    • 84870856655 scopus 로고    scopus 로고
    • US-Russian cooperative program in researchand development of chemical separation technologies
    • Choppin GC, Khankhasayev M, Plendi HS, eds Rep. DOE/EM-0591, Columbus: Battelle
    • Romanovsky VN. US-Russian cooperative program in researchand development of chemical separation technologies.In: Choppin GC, Khankhasayev M, Plendi HS, eds.,Chemical Separations in Nuclear Waste Management: TheState of the Art and a Look to the Future. Rep. DOE/EM-0591, Columbus: Battelle, 2001:57.
    • (2001) Chemical Separations in Nuclear Waste Management: TheState of the Art and A Look to the Future , pp. 57
    • Romanovsky, V.N.1
  • 20
    • 0027656854 scopus 로고
    • Preliminaryevaluation of chromatographic techniques for theseparation of radionuclides from high level radioactivewaste
    • Lumetta GJ, Wester DW, Morrey JR, Wagner MJ. Preliminaryevaluation of chromatographic techniques for theseparation of radionuclides from high level radioactivewaste. Solv Extr Ion Exch 1993;11:663.
    • (1993) Solv Extr Ion Exch , vol.11 , pp. 663
    • Lumetta, G.J.1    Wester, D.W.2    Morrey, J.R.3    Wagner, M.J.4
  • 21
    • 0011493234 scopus 로고
    • Preparation ofstrontium-90 free yttrium-90 by electrolysis
    • Lange G, Herrmann G, Strassmann F. Preparation ofstrontium-90 free yttrium-90 by electrolysis. J Inorg NuclChem 1957;4:146.
    • (1957) J Inorg NuclChem , vol.4 , pp. 146
    • Lange, G.1    Herrmann, G.2    Strassmann, F.3
  • 22
    • 0025000520 scopus 로고
    • Chemistry forcommercial-scale production of yttrium-90 for medical research
    • Wike JS, Guyer CE, Ramey DW, Phillips BP. Chemistry forcommercial-scale production of yttrium-90 for medical research.Appl Radiat Isot 1990;41:861.
    • (1990) Appl Radiat Isot , vol.41 , pp. 861
    • Wike, J.S.1    Guyer, C.E.2    Ramey, D.W.3    Phillips, B.P.4
  • 23
    • 0001699925 scopus 로고
    • Study on the separation of carrier freeYttrium-90 from Sr-90
    • Lee TW, Ting G. Study on the separation of carrier freeYttrium-90 from Sr-90. Isotopenpraxis 1991;27:269.
    • (1991) Isotopenpraxis , vol.27 , pp. 269
    • Lee, T.W.1    Ting, G.2
  • 24
    • 0026764230 scopus 로고
    • Improved chemistry for productionof yttrium-90 for medical applications
    • Dietz LM, Horwitz EP. Improved chemistry for productionof yttrium-90 for medical applications. Appl Radiat Isot1992;43:1093.
    • (1992) Appl Radiat Isot , vol.43 , pp. 1093
    • Dietz, L.M.1    Horwitz, E.P.2
  • 25
    • 0027897664 scopus 로고
    • Preparation ofcarrier-free yttrium-90 for medical applications by solventextraction chromatography
    • Hsieh BT, Ting G, Hsieh HT, Shen LH. Preparation ofcarrier-free yttrium-90 for medical applications by solventextraction chromatography. Appl Radiat Isot 1993;44:1473.
    • (1993) Appl Radiat Isot , vol.44 , pp. 1473
    • Hsieh, B.T.1    Ting, G.2    Hsieh, H.T.3    Shen, L.H.4
  • 26
    • 0028185165 scopus 로고
    • Preparation of a 90Sr-90Y generatorusing zirconium antimonate
    • Dash A, Bhattacharya PK. Preparation of a 90Sr-90Y generatorusing zirconium antimonate. Appl Radiat Isot 1994;45:415.
    • (1994) Appl Radiat Isot , vol.45 , pp. 415
    • Dash, A.1    Bhattacharya, P.K.2
  • 27
    • 78049461365 scopus 로고    scopus 로고
    • Productionof large quantities of 90y by ion-exchange chromatographyusing an organic resin and a chelating agent
    • Castillo AX, Pérez-Malo M, Isaac-Olivé K, et al. Productionof large quantities of 90Y by ion-exchange chromatographyusing an organic resin and a chelating agent. Nucl Med Biol2010;37:935.
    • (2010) Nucl Med Biol , vol.37 , pp. 935
    • Castillo, A.X.1    Pérez-Malo, M.2    Isaac-Olivé, K.3
  • 28
    • 77949408953 scopus 로고    scopus 로고
    • Separation of carrierfree90Y from 90Sr by SLM technique using D2EHPA in Ndodecaneas carrier
    • Naik PW, Jagasia P, Dhami PS, et al. Separation of carrierfree90Y from 90Sr by SLM technique using D2EHPA in Ndodecaneas carrier. Sep Sci Technol 2010;45:554.
    • (2010) Sep Sci Technol , vol.45 , pp. 554
    • Naik, P.W.1    Jagasia, P.2    Dhami, P.S.3
  • 29
    • 75949096448 scopus 로고    scopus 로고
    • An adaptedpurification procedure to improve the quality of 90Y forclinical use
    • Castillo AX, Isaac-Olivé K, González EC, et al. An adaptedpurification procedure to improve the quality of 90Y forclinical use. Radiochim Acta 2009;97:739.
    • (2009) Radiochim Acta , vol.97 , pp. 739
    • Castillo, A.X.1    Isaac-Olivé, K.2    González, E.C.3
  • 31
    • 67349185570 scopus 로고    scopus 로고
    • One column operation for90Sr/90Y separation by using a functionalized-silica
    • Lee JS, Park UJ, Son KJ, Han HS. One column operation for90Sr/90Y separation by using a functionalized-silica. ApplRadiat Isot 2009;67:1332.
    • (2009) ApplRadiat Isot , vol.67 , pp. 1332
    • Lee, J.S.1    Park, U.J.2    Son, K.J.3    Han, H.S.4
  • 32
    • 59949097818 scopus 로고    scopus 로고
    • Separation ofthe 90Sr-90Y pair with cerium (IV) iodotungstate cation exchanger
    • Dhara S, Sarkar S, Basu S, Chattopadhyay P. Separation ofthe 90Sr-90Y pair with cerium (IV) iodotungstate cation exchanger.Appl Radiat Isot 2009;67:530.
    • (2009) Appl Radiat Isot , vol.67 , pp. 530
    • Dhara, S.1    Sarkar, S.2    Basu, S.3    Chattopadhyay, P.4
  • 33
    • 34147101805 scopus 로고    scopus 로고
    • Studies on thedevelopment of a two stage SLM system for the separationof carrier-free 90Y using KSM-17 and CMPO as carriers
    • Dhami PS, Naik PW, Dudwadkar NL, et al. Studies on thedevelopment of a two stage SLM system for the separationof carrier-free 90Y using KSM-17 and CMPO as carriers. SepSci Technol 2007;42:1107.
    • (2007) SepSci Technol , vol.42 , pp. 1107
    • Dhami, P.S.1    Naik, P.W.2    Dudwadkar, N.L.3
  • 38
    • 11044225560 scopus 로고    scopus 로고
    • Inorganic ion-exchangers: Their role in chromatographicradionuclide generators for the decade 1993-2002
    • Mushtaq A. Inorganic ion-exchangers: Their role in chromatographicradionuclide generators for the decade 1993-2002. J Radioanal NuclChem 2004;262:797.
    • (2004) J Radioanal NuclChem , vol.262 , pp. 797
    • Mushtaq, A.1
  • 39
    • 0001388546 scopus 로고
    • Separation of carrier-free 90Y from 90Sr bycation exchange in a methanol-ammonium acetate medium
    • Kawashima T. Separation of carrier-free 90Y from 90Sr bycation exchange in a methanol-ammonium acetate medium.Int J Appl Radiat Isot 1969;20:806.
    • (1969) Int J Appl Radiat Isot , vol.20 , pp. 806
    • Kawashima, T.1
  • 41
    • 0023638938 scopus 로고
    • Generator-produced Yttrium-90for radioimmunotherapy
    • Chinol M, Hnatowich DJ. Generator-produced Yttrium-90for radioimmunotherapy. J Nucl Med 1987;28:1465.
    • (1987) J Nucl Med , vol.28 , pp. 1465
    • Chinol, M.1    Hnatowich, D.J.2
  • 42
    • 14744289970 scopus 로고    scopus 로고
    • Simple and safeproduction of yttrium-90 from a new type of 90Sr/90Y generator
    • Du J, Chinol M, Savonen A, Hiltunen J. Simple and safeproduction of yttrium-90 from a new type of 90Sr/90Y generator.Radiochim Acta 2005;93:111.
    • (2005) Radiochim Acta , vol.93 , pp. 111
    • Du, J.1    Chinol, M.2    Savonen, A.3    Hiltunen, J.4
  • 43
    • 0033871096 scopus 로고    scopus 로고
    • Preparation of 90Y by the90Sr-90Y generator for medical purpose
    • Malja S, Schomacker K, Malja E. Preparation of 90Y by the90Sr-90Y generator for medical purpose. J Radioanal NuclChem 2000;245:403.
    • (2000) J Radioanal NuclChem , vol.245 , pp. 403
    • Malja, S.1    Schomacker, K.2    Malja, E.3
  • 45
    • 84943686061 scopus 로고
    • Separation of 90Y from 90Sr on crystalline antimonicacid
    • Bilewicz A. Separation of 90Y from 90Sr on crystalline antimonicacid. Radiochim Acta 1995;69:137.
    • (1995) Radiochim Acta , vol.69 , pp. 137
    • Bilewicz, A.1
  • 49
    • 84859516351 scopus 로고    scopus 로고
    • Sodium titaniumsilicateas ion exchanger: Synthesis, characterization and applicationin separation of 90Y from 90Sr
    • Chakraborty R, Chattopadhyay P. Sodium titaniumsilicateas ion exchanger: Synthesis, characterization and applicationin separation of 90Y from 90Sr. J Radioanal Nucl Chem2012;294:31.
    • (2012) J Radioanal Nucl Chem , vol.294 , pp. 31
    • Chakraborty, R.1    Chattopadhyay, P.2
  • 50
    • 1842688070 scopus 로고    scopus 로고
    • Separation of 90Yfrom 90Sr using zirconium vanadate as the ion exchanger
    • Roy K, Mohapatra PK, Rawat N, et al. Separation of 90Yfrom 90Sr using zirconium vanadate as the ion exchanger.Appl Radiat Isot 2004;60:621.
    • (2004) Appl Radiat Isot , vol.60 , pp. 621
    • Roy, K.1    Mohapatra, P.K.2    Rawat, N.3
  • 51
    • 78751629452 scopus 로고    scopus 로고
    • Quinolinephosphomolybdateas ion exchanger: Synthesis,characterization, and application in separation
    • Chakraborty R, Dhara S, Basu S, Chattopadhyay P. Quinolinephosphomolybdateas ion exchanger: Synthesis,characterization, and application in separation. J RadioanalNucl Chem 2011;287:55.
    • (2011) J RadioanalNucl Chem , vol.287 , pp. 55
    • Chakraborty, R.1    Dhara, S.2    Basu, S.3    Chattopadhyay, P.4
  • 52
    • 0001205854 scopus 로고
    • The use of dioctylphosphoric acid extraction in the isolation of carrier-free90Y, 140La, 144Ce, 143Pr, and 144Pr
    • Peppard DF, Mason GW, Moline SW. The use of dioctylphosphoric acid extraction in the isolation of carrier-free90Y, 140La, 144Ce, 143Pr, and 144Pr. J Inorg Nucl Chem1957;132:141.
    • (1957) J Inorg Nucl Chem , vol.132 , pp. 141
    • Peppard, D.F.1    Mason, G.W.2    Moline, S.W.3
  • 53
    • 0001732110 scopus 로고
    • A new method for the carrier-free production of90Y from 90Sr-90Y mixture and 89Sr from neutron-irradiatedY2O3
    • Mirza MY. A new method for the carrier-free production of90Y from 90Sr-90Y mixture and 89Sr from neutron-irradiatedY2O3. Anal Chim Acta 1968;40:229.
    • (1968) Anal Chim Acta , vol.40 , pp. 229
    • Mirza, M.Y.1
  • 54
    • 53749092112 scopus 로고    scopus 로고
    • Production ofhigh-purity 90Y on specially developed centrifugal semicounterflowextractors
    • Kodina GE, Korpusov GV, Filyanin AT. Production ofhigh-purity 90Y on specially developed centrifugal semicounterflowextractors. Radiochemistry 2002;44:62.
    • (2002) Radiochemistry , vol.44 , pp. 62
    • Kodina, G.E.1    Korpusov, G.V.2    Filyanin, A.T.3
  • 55
    • 77956419212 scopus 로고    scopus 로고
    • Preparation of 90ycl3radiopharmaceutical precursor for nuclear medicine usingtechnology of centrifugal extractors
    • Srank J, Melichar F, Filyanin AT, et al. Preparation of 90YCl3radiopharmaceutical precursor for nuclear medicine usingtechnology of centrifugal extractors. Appl Radiat Isot2010;68:2163.
    • (2010) Appl Radiat Isot , vol.68 , pp. 2163
    • Srank, J.1    Melichar, F.2    Filyanin, A.T.3
  • 56
    • 0028902936 scopus 로고
    • The solvent extraction of carrier-free 90Y
    • Chuang JT, Lo JG. The solvent extraction of carrier-free 90Y.J Radioanal Nucl Chem 1995;189:307.
    • (1995) J Radioanal Nucl Chem , vol.189 , pp. 307
    • Chuang, J.T.1    Lo, J.G.2
  • 57
    • 0000911565 scopus 로고
    • Separation of 90Y From90Sr by solvent extraction with ionizable crown ethers
    • Wood DJ, Elshani S, Du HS, et al. Separation of 90Y from90Sr by solvent extraction with ionizable crown ethers. AnalChem 1993;65:1350.
    • (1993) Anal Chem , vol.65 , pp. 1350
    • Wood, D.J.1    Elshani, S.2    Du, H.S.3
  • 58
    • 1542525111 scopus 로고    scopus 로고
    • Solvent extraction in the treatmentof acidic high-level liquid waste: Where do we stand?
    • Bond AH, Dietz ML, Rogers RD, eds WashingtonD.C.: American Chemical Society
    • Horwitz EP, Schulz WW. Solvent extraction in the treatmentof acidic high-level liquid waste: Where do we stand?In: Bond AH, Dietz ML, Rogers RD, eds., Metal-Ion Separationand Preconcentration: Progress and Opportunities,ACS Symposium Series 716, Vol. 716, WashingtonD.C.: American Chemical Society, 1999:20.
    • (1999) Metal-Ion Separationand Preconcentration: Progress and Opportunities,ACS Symposium Series 716 , vol.716 , pp. 20
    • Horwitz, E.P.1    Schulz, W.W.2
  • 59
    • 0036206122 scopus 로고    scopus 로고
    • Separation of microamounts of yttriumfrom strontium by using nitrobenzene solution ofsodium dicarbollylcobaltate in the presence of 18 crown-6
    • Vanura P, Makrlik E. Separation of microamounts of yttriumfrom strontium by using nitrobenzene solution ofsodium dicarbollylcobaltate in the presence of 18-crown-6. JRadioanal Nucl Chem 2002;251:499.
    • (2002) JRadioanal Nucl Chem , vol.251 , pp. 499
    • Vanura, P.1    Makrlik, E.2
  • 60
    • 33746435243 scopus 로고    scopus 로고
    • Separation of microamounts ofyttrium from strontium by using sodium dicarbollylcobaltate,Slovafol 909 and ethylenediamine-N, N, N¢,N¢- tetraacetic acid in the water-nitrobenzene extractionsystem
    • Makrlik E, Vanura P. Separation of microamounts ofyttrium from strontium by using sodium dicarbollylcobaltate,Slovafol 909 and ethylenediamine-N, N, N¢,N¢-tetraacetic acid in the water-nitrobenzene extractionsystem. J Radioanal Nucl Chem 2006;268:645.
    • (2006) J Radioanal Nucl Chem , vol.268 , pp. 645
    • Makrlik, E.1    Vanura, P.2
  • 61
    • 0036069255 scopus 로고    scopus 로고
    • Separation of yttriumfromstrontium in the aqueous phase of the water/nitrobenzeneextraction system
    • Vanura P, Makrlik E, Vobecky M. Separation of yttriumfromstrontium in the aqueous phase of the water/nitrobenzeneextraction system. J Radioanal Nucl Chem 2003;256:171.
    • (2003) J Radioanal Nucl Chem , vol.256 , pp. 171
    • Vanura, P.1    Makrlik, E.2    Vobecky, M.3
  • 62
    • 30844445526 scopus 로고    scopus 로고
    • Radiochemical 90Sr/90Ygenerator using two phase heptachloro-bis-1,2- dicarbollylcobaltatecrown extraction system
    • Vanura P, Jedináková-Kŕ-zová V. Radiochemical 90Sr/90Ygenerator using two phase heptachloro-bis-1,2-dicarbollylcobaltatecrown extraction system. Czech J Phys 2003;53:A459.
    • (2003) Czech J Phys , vol.53
    • Vanura, P.1    Jedináková-Kŕzová, V.2
  • 63
    • 77958498189 scopus 로고    scopus 로고
    • Separation of 90Yfrom 90Sr by a solvent extraction method using N,N,N¢,N¢-tetraoctyl diglycolamide(TODGA) as the extractant
    • Dutta S, Mohapatra PK, Manchanda VK. Separation of 90Yfrom 90Sr by a solvent extraction method using N,N,N¢,N¢-tetraoctyl diglycolamide(TODGA) as the extractant. ApplRadiat Isot 2011;69:158.
    • (2011) Appl Radiat Isot , vol.69 , pp. 158
    • Dutta, S.1    Mohapatra, P.K.2    Manchanda, V.K.3
  • 64
    • 84857141664 scopus 로고    scopus 로고
    • Role of diluents on theseparation of 90Y from 90Sr by solvent extraction and supportedliquid membrane using T2EHDGA as the extractant
    • Dutta S, Raut DR, Mohapatra PK. Role of diluents on theseparation of 90Y from 90Sr by solvent extraction and supportedliquid membrane using T2EHDGA as the extractant.Appl Radiat Isot 2012;70:670.
    • (2012) Appl Radiat Isot , vol.70 , pp. 670
    • Dutta, S.1    Raut, D.R.2    Mohapatra, P.K.3
  • 65
    • 0009580332 scopus 로고
    • A Yttrium-90 generator giving high radiochemical purity
    • Malinin AB, Kurchatova LN, Tronova IN, et al. A Yttrium-90 generator giving high radiochemical purity. Radiokhimiya1984;26:500.
    • (1984) Radiokhimiya , vol.26 , pp. 500
    • Malinin, A.B.1    Kurchatova, L.N.2    Tronova, I.N.3
  • 66
    • 0034001918 scopus 로고    scopus 로고
    • Separation ofcarrier-free 90Y from high level waste by extraction chromatographictechnique using 2-Ethyl hexyl-2-ethyl hexylphosphonic acid (KSM-17)
    • Achuthan PV, Dhami PS, Kannan R, et al. Separation ofcarrier-free 90Y from high level waste by extraction chromatographictechnique using 2-Ethyl hexyl-2-ethyl hexylphosphonic acid (KSM-17). Sep Sci Technol 2000;35:261.
    • (2000) Sep Sci Technol , vol.35 , pp. 261
    • Achuthan, P.V.1    Dhami, P.S.2    Kannan, R.3
  • 69
    • 0026130678 scopus 로고
    • Separation and preconcentrationof strontium from biological environmentaland nuclear waste samples by extraction chromatographyusing a crown ether
    • Horwitz EP, Dietz ML, Fisher DE. Separation and preconcentrationof strontium from biological, environmental,and nuclear waste samples by extraction chromatographyusing a crown ether. Anal Chem 1991;63:522.
    • (1991) Anal Chem , vol.63 , pp. 522
    • Horwitz, E.P.1    Dietz, M.L.2    Fisher, D.E.3
  • 70
    • 0029938218 scopus 로고    scopus 로고
    • Extraction chromatographic separationof carrier-free 90Y from 90Sr/90Y generator by crown ethercoated silica gels
    • Chuang JT, Lo JG. Extraction chromatographic separationof carrier-free 90Y from 90Sr/90Y generator by crown ethercoated silica gels. J Radioanal Nucl Chem 1996;204:83.
    • (1996) J Radioanal Nucl Chem , vol.204 , pp. 83
    • Chuang, J.T.1    Lo, J.G.2
  • 72
    • 80051909996 scopus 로고    scopus 로고
    • Chromatographicseparation of carrier free 90Y from 90Sr using adiglycolamide based resin for possible pharmaceutical applications
    • Dutta S, Mohapatra PK, Raut DR, Manchanda VK. Chromatographicseparation of carrier free 90Y from 90Sr using adiglycolamide based resin for possible pharmaceutical applications.J Chromatogr A 2011;1218:6483.
    • (2011) J Chromatogr A , vol.1218 , pp. 6483
    • Dutta, S.1    Mohapatra, P.K.2    Raut, D.R.3    Manchanda, V.K.4
  • 73
    • 0000363132 scopus 로고
    • Separation of pure 90Y from a 90Sr-90Y mixture byco-precipitation with ferric hydroxide
    • Koda Y. Separation of pure 90Y from a 90Sr-90Y mixture byco-precipitation with ferric hydroxide. J Inorg Nucl Chem1963;25:733.
    • (1963) J Inorg Nucl Chem , vol.25 , pp. 733
    • Koda, Y.1
  • 75
    • 0015115103 scopus 로고
    • A new method for the separationof multicurie quantities of 90Y from 90Sr
    • Kanapilly GM, Newton GJ. A new method for the separationof multicurie quantities of 90Y from 90Sr. Int J ApplRadiat Isot 1971;22:567.
    • (1971) Int J ApplRadiat Isot , vol.22 , pp. 567
    • Kanapilly, G.M.1    Newton, G.J.2
  • 76
    • 0035115839 scopus 로고    scopus 로고
    • Separationof carrier-free 90Y from high level waste by supported liquidmembrane using KSM-17
    • Ramanujam A, Achuthan PV, Dhami PS, et al. Separationof carrier-free 90Y from high level waste by supported liquidmembrane using KSM-17. J Radioanal Nucl Chem2001;247:185.
    • (2001) J Radioanal Nucl Chem , vol.247 , pp. 185
    • Ramanujam, A.1    Achuthan, P.V.2    Dhami, P.S.3
  • 77
    • 0041862723 scopus 로고    scopus 로고
    • Sr/Y separationby supported liquid membranes based on nuclear trackmicro filters
    • Happel S, Streng R, Vater P, Ensinger W. Sr/Y separationby supported liquid membranes based on nuclear trackmicro filters. Radiat Meas 2003;36:761.
    • (2003) Radiat Meas , vol.36 , pp. 761
    • Happel, S.1    Streng, R.2    Vater, P.3    Ensinger, W.4
  • 78
    • 79957917803 scopus 로고    scopus 로고
    • Separation of carrier free 90Y from 90Sr by hollow fibersupported liquid membrane containing bis(2-ethylhexyl)phosphonic acid
    • Kandwal P, Ansari SA, Mohapatra PK, Manchanda VK.Separation of carrier free 90Y from 90Sr by hollow fibersupported liquid membrane containing bis(2-ethylhexyl)phosphonic acid. Sep Sci Technol 2011;46:904.
    • (2011) Sep Sci Technol , vol.46 , pp. 904
    • Kandwal, P.1    Ansari, S.A.2    Mohapatra, P.K.3    Manchanda, V.K.4
  • 79
    • 24244478031 scopus 로고
    • Rapid paperelectrophoreticseparation of strontium from yttrium,caesium from barium and thallium from lead and bismuthin radioactive mixtures
    • Van Dijk H, Ijsseling FP, Loman H. Rapid paperelectrophoreticseparation of strontium from yttrium,caesium from barium and thallium from lead and bismuthin radioactive mixtures. Anal Chim Acta 1962;27:563.
    • (1962) Anal Chim Acta , vol.27 , pp. 563
    • Van Dijk, H.1    Ijsseling, F.P.2    Loman, H.3
  • 80
    • 27144530560 scopus 로고
    • Isolation of carrierfree yttrium from the radioactive strontium-yttrium systemby electrochemical deposition
    • Hamaguchi H, Ikeda N, Kawashima T. Isolation of carrierfree yttrium from the radioactive strontium-yttrium systemby electrochemical deposition. Bunseki Kagaku 1958;7:243.
    • (1958) Bunseki Kagaku , vol.7 , pp. 243
    • Hamaguchi, H.1    Ikeda, N.2    Kawashima, T.3
  • 81
    • 50549219237 scopus 로고
    • Radiochemical separation ofstrontium by amalgam exchange
    • Qureshi IH, Meinke WW. Radiochemical separation ofstrontium by amalgam exchange. Talanta 1963;10:737.
    • (1963) Talanta , vol.10 , pp. 737
    • Qureshi, I.H.1    Meinke, W.W.2
  • 82
    • 38849155084 scopus 로고    scopus 로고
    • Developmentof an electrochemical 90sr-90y generator for the separationof 90Y suitable for targeted therapy
    • Chakravarty R, Pandey U, Manolkar RB, et al. Developmentof an electrochemical 90Sr-90Y generator for the separationof 90Y suitable for targeted therapy. Nucl Med Biol2008;35:245-252.
    • (2008) Nucl Med Biol , vol.35 , pp. 245-252
    • Chakravarty, R.1    Pandey, U.2    Manolkar, R.B.3
  • 85
    • 0022408741 scopus 로고
    • DTPA-coupled antibodieslabeled with yttrium-90
    • Hnatowich DJ, Virzi F, Doherty PW. DTPA-coupled antibodieslabeled with yttrium-90. J Nucl Med 1985;26:503.
    • (1985) J Nucl Med , vol.26 , pp. 503
    • Hnatowich, D.J.1    Virzi, F.2    Doherty, P.W.3
  • 86
    • 4243224267 scopus 로고    scopus 로고
    • Some aspects ofthe Sr-90-Y-90 generator production and development of anew quality control method
    • Schomä cker K, Malja S, Cuci T, Fisher T. Some aspects ofthe Sr-90-Y-90 generator production and development of anew quality control method. J Nucl Med 1997;38:103.
    • (1997) J Nucl Med , vol.38 , pp. 103
    • Schomäcker, K.1    Malja, S.2    Cuci, T.3    Fisher, T.4
  • 88
    • 0034976120 scopus 로고    scopus 로고
    • Complexationstudies with 90Y from a novel 90Sr-90Y Generator
    • Venkatesh M, Pandey U, Dhami PS, et al. Complexationstudies with 90Y from a novel 90Sr-90Y Generator. RadiochimActa 2001;89:1.
    • (2001) RadiochimActa , vol.89 , pp. 1
    • Venkatesh, M.1    Pandey, U.2    Dhami, P.S.3
  • 89
    • 25144462140 scopus 로고
    • Preparation and half life of carrier-free Yttrium-90
    • Salutsky ML, Kirby HW. Preparation and half life of carrier-free Yttrium-90. Anal Chem 1955;27:567.
    • (1955) Anal Chem , vol.27 , pp. 567
    • Salutsky, M.L.1    Kirby, H.W.2
  • 90
    • 30844459283 scopus 로고    scopus 로고
    • The use ofliquid scintillation spectrometry for the determination ofradionuclidic purity of 90Y from a radiochemical 90Y/90Srgenerator
    • Vanura P, Jedináková-Kr?́-zová V, Vobecký M. The use ofliquid scintillation spectrometry for the determination ofradionuclidic purity of 90Y from a radiochemical 90Y/90Srgenerator. J Radioanal Nucl Chem 2006;267:501.
    • (2006) J Radioanal Nucl Chem , vol.267 , pp. 501
    • Vanura, P.1    Jedináková-Krízová, V.2    Vobecký, M.3
  • 92
  • 93
    • 68949197250 scopus 로고
    • Rapid determinationof 90sr impurities in freshly generator eluted90y for radiopharmaceutical preparation
    • Bonardi ML, Martano L, Groppi F, Chinol M. Rapid determinationof 90Sr impurities in freshly generator eluted90Y for radiopharmaceutical preparation. Appl Radiat Isot2009;67:1874.
    • (1874) Appl Radiat Isot , vol.67
    • Bonardi, M.L.1    Martano, L.2    Groppi, F.3    Chinol, M.4
  • 94
    • 38849128855 scopus 로고    scopus 로고
    • A novel extractionpaper chromatography (EPC) technique for the radionuclidicpurity evaluation of 90Y for clinical use
    • Pandey U, Dhami PS, Jagesia P, et al. A novel extractionpaper chromatography (EPC) technique for the radionuclidicpurity evaluation of 90Y for clinical use. AnalChem 2008;80:801.
    • (2008) Anal Chem , vol.80 , pp. 801
    • Pandey, U.1    Dhami, P.S.2    Jagesia, P.3
  • 96
    • 0000757237 scopus 로고
    • Ion exchangeselectivity scales for cations in nitric acid and sulfuric acidmedia with a sulfonated polystyrene resin
    • Strelow FEW, Rethemeyer R, Bothma CJC. Ion exchangeselectivity scales for cations in nitric acid and sulfuric acidmedia with a sulfonated polystyrene resin. Anal Chem1965;37:106.
    • (1965) Anal Chem , vol.37 , pp. 106
    • Strelow, F.E.W.1    Rethemeyer, R.2    Bothma, C.J.C.3
  • 98
    • 23044490363 scopus 로고    scopus 로고
    • Estimation of radioactivity levels associatedwith a 90Sr dirty bomb event
    • Reshetin VP. Estimation of radioactivity levels associatedwith a 90Sr dirty bomb event. Atmos Environ 2005;39:4471.
    • (2005) Atmos Environ , vol.39 , pp. 4471
    • Reshetin, V.P.1
  • 100
    • 84870793901 scopus 로고    scopus 로고
    • Available at: Accessed on April, 4, 2012
    • What is non-Hodgkin lymphoma? American Cancer Society.Available at: www.cancer.org/Cancer/Non-HodgkinLymphoma/DetailedGuide/non-hodgkinlymphoma- what-isnon-hodgkin-lymphoma. Accessed on April 4, 2012.
    • What Is Non-Hodgkin Lymphoma? American Cancer Society
  • 101
    • 0024989347 scopus 로고
    • A case control study of non-Hodgkin's lymphjomaand the herbicide 2, 4-dichlorophenoxyacetic acid(2, 4-D) inEastern Nebraska
    • Zahm S. A case control study of non-Hodgkin's lymphjomaand the herbicide 2,4-dichlorophenoxyacetic acid(2, 4-D) inEastern Nebraska. Epidemiology 1990;1:349.
    • (1990) Epidemiology , vol.1 , pp. 349
    • Zahm, S.1
  • 102
    • 84870793061 scopus 로고    scopus 로고
    • American Cancer Society Available at Accessed on April 4, 2012
    • American Cancer Society. Types of non-Hodgkin lymphoma.Available at:www.cancer.org/Cancer/Non-HodgkinLymphoma/DetailedGuide/non-hodgkinlymphoma- typesof-non-hodgkin-lymphoma. Accessed on April 4, 2012.
    • Types of Non-Hodgkin Lymphoma
  • 104
    • 46249117312 scopus 로고    scopus 로고
    • Radioimmunotherapy in non-Hodgkin's lymphoma:Can it change the course of the disease?
    • Illidge T. Radioimmunotherapy in non-Hodgkin's lymphoma:Can it change the course of the disease? HematolMeet Rep 2007;1:52.
    • (2007) Hematol Meet Rep , vol.1 , pp. 52
    • Illidge, T.1
  • 105
    • 84870849028 scopus 로고    scopus 로고
    • Immunotherapy and radioimmunotherapyfor non-Hodgkin's Lymphoma
    • Sioka C, Fotopoulos A. Immunotherapy and radioimmunotherapyfor non-Hodgkin's Lymphoma. CancerTher 2008;6:311.
    • (2008) Cancer Ther , vol.6 , pp. 311
    • Sioka, C.1    Fotopoulos, A.2
  • 106
    • 80053195081 scopus 로고    scopus 로고
    • Review of 90y-ibritumomab tiuxetan asfirst-line consolidation radio-immunotherapy for b-cellfollicular non-hodgkin's lymphoma
    • Emmanouilides C. Review of 90Y-ibritumomab tiuxetan asfirst-line consolidation radio-immunotherapy for B-cellfollicular non-Hodgkin's lymphoma. Cancer Manage Res2009;2:131.
    • (2009) Cancer Manage Res , vol.2 , pp. 131
    • Emmanouilides, C.1
  • 107
    • 0032761164 scopus 로고    scopus 로고
    • Phase I/II trial ofIDEC-Y2B8 radioimmunotherapy for treatment of relapsedor refractory CD20 + B-cell non-Hodgkin's lymphoma
    • Witzig TE, White CA, Wiseman GA, et al. Phase I/II trial ofIDEC-Y2B8 radioimmunotherapy for treatment of relapsedor refractory CD20 + B-cell non-Hodgkin's lymphoma. JClin Oncol 1999;17:3793.
    • (1999) J Clin Oncol , vol.17 , pp. 3793
    • Witzig, T.E.1    White, C.A.2    Wiseman, G.A.3
  • 108
    • 0037093241 scopus 로고    scopus 로고
    • Randomizedcontrolled trial of Yttrium-90-labeled Ibritumomab Tiuxetanradioimmunotherapy versus Rituximab Immunotherapy for patients with relapsed or refractory low-grade, follicular, ortransformed B-Cell non-hodgkin's lymphoma
    • Witzig TE, Gordon LI, Cabanillas F, et al. Randomizedcontrolled trial of Yttrium-90-labeled Ibritumomab Tiuxetanradioimmunotherapy versus Rituximab Immunotherapy for patients with relapsed or refractory low-grade, follicular, ortransformed B-Cell non-hodgkin's lymphoma. J Clin Oncol2002;20:2453.
    • (2002) J Clin Oncol , vol.20 , pp. 2453
    • Witzig, T.E.1    Gordon, L.I.2    Cabanillas, F.3
  • 109
    • 0003258929 scopus 로고    scopus 로고
    • Zevalin radioimmunotherapyof rituximab-refractory follicular non-Hodgkin's lymphoma
    • Witzig TE, White CA, Flinn IW. Zevalin radioimmunotherapyof rituximab-refractory follicular non-Hodgkin's lymphoma. Blood 2000;96:507a.
    • (2000) Blood , vol.96
    • Witzig, T.E.1    White, C.A.2    Flinn, I.W.3
  • 110
    • 0003262530 scopus 로고    scopus 로고
    • Reduced dose Zevalinis safe and effective in patients with relapsed or refractory,low grade follicular or CD20 + transformed B cell non-Hodgkin's lymphoma (L/F/T NHL) and mild thrombocytopenia
    • Witzig TE, Gordon LI, Wiseman GA. Reduced dose Zevalinis safe and effective in patients with relapsed or refractory,low grade, follicular or CD20 + transformed B cell non-Hodgkin's lymphoma (L/F/T NHL) and mild thrombocytopenia.Blood 2000;96:728a.
    • (2000) Blood , vol.96
    • Witzig, T.E.1    Gordon, L.I.2    Wiseman, G.A.3
  • 111
    • 0002257549 scopus 로고    scopus 로고
    • Carcinoid tumors and the carcinoidsyndrome
    • De Vita VT, Heilman S, Rosenburg SA, eds 5th edition.Cambridge, MA: Blackwell Scientific Publications
    • Jensen RT, Norton JA. Carcinoid tumors and the carcinoidsyndrome. In: DeVita VT, Heilman S, Rosenburg SA, eds.,Cancer: Principles and Practice of Oncology, 5th edition.Cambridge, MA: Blackwell Scientific Publications,1996: 1706.
    • (1996) Cancer: Principles and Practice of Oncology , pp. 1706
    • Jensen, R.T.1    Norton, J.A.2
  • 112
    • 0034924612 scopus 로고    scopus 로고
    • Somatostatinreceptor sst1-sst5 expression in normal and neoplastichuman tissues using receptor autoradiography withsubtype-selective ligands
    • Reubi JC, Waser B, Schaer JC, Laissue JA. Somatostatinreceptor sst1-sst5 expression in normal and neoplastichuman tissues using receptor autoradiography withsubtype-selective ligands. Eur J Nucl Med 2001;28:836.
    • (2001) Eur J Nucl Med , vol.28 , pp. 836
    • Reubi, J.C.1    Waser, B.2    Schaer, J.C.3    Laissue, J.A.4
  • 113
    • 84858797288 scopus 로고    scopus 로고
    • Radionuclide therapyin neuroendocrine tumours: A systematic review
    • Gulenchyn KY, Yao X, Asa SL, et al. Radionuclide therapyin neuroendocrine tumours: A systematic review. ClinOncol 2012;24:294.
    • (2012) Clin Oncol , vol.24 , pp. 294
    • Gulenchyn, K.Y.1    Yao, X.2    Asa, S.L.3
  • 115
    • 32144463528 scopus 로고    scopus 로고
    • Targetedradionuclide therapy with 90Y-DOTATOC in patientswith neuroendocrine tumors
    • Forrer F, Waldherr C, Maecke HR, Mueller-Brand J. Targetedradionuclide therapy with 90Y-DOTATOC in patientswith neuroendocrine tumors. Anticancer Res 2006;26:703.
    • (2006) Anticancer Res , vol.26 , pp. 703
    • Forrer, F.1    Waldherr, C.2    Maecke, H.R.3    Mueller-Brand, J.4
  • 116
    • 3142724702 scopus 로고    scopus 로고
    • Receptor radionuclidetherapy with 90Y-[DOTA]0-Tyr3-octreotide (90Y-DOTATOC)in neuroendocrine tumours
    • Bodei L, Cremonesi M, Grana C, et al. Receptor radionuclidetherapy with 90Y-[DOTA]0-Tyr3-octreotide (90Y-DOTATOC)in neuroendocrine tumours. Eur J Nucl Med MolImaging 2004;31:1038.
    • (2004) Eur J Nucl Med MolImaging , vol.31 , pp. 1038
    • Bodei, L.1    Cremonesi, M.2    Grana, C.3
  • 117
    • 83755220912 scopus 로고    scopus 로고
    • Radiopeptide imaging and therapyin the United States
    • Graham MM, Menda Y. Radiopeptide imaging and therapyin the United States. J Nucl Med 2011;52:56S.
    • (2011) J Nucl Med , vol.52
    • Graham, M.M.1    Menda, Y.2
  • 118
    • 83755225132 scopus 로고    scopus 로고
    • Radiopeptide imagingand therapy in Europe
    • Ambrosini V, Fani M, Fanti S, et al. Radiopeptide imagingand therapy in Europe. J Nucl Med 2011;52:42S.
    • (2011) J Nucl Med , vol.52
    • Ambrosini, V.1    Fani, M.2    Fanti, S.3
  • 119
    • 83255164664 scopus 로고    scopus 로고
    • Efficacyand safety of 90Y-DOTATATE therapy in neuroendocrinetumours
    • Sowa-Staszczak A, Pach D, Kunikowska J, et al. Efficacyand safety of 90Y-DOTATATE therapy in neuroendocrinetumours. Pol J Endocrinol 2011;62:392.
    • (2011) Pol J Endocrinol , vol.62 , pp. 392
    • Sowa-Staszczak, A.1    Pach, D.2    Kunikowska, J.3
  • 120
    • 0032579454 scopus 로고    scopus 로고
    • Pre-clinicalcomparison of [DTPA0, Tyr3]octreotide and [DOTA0,D-Phe1, Tyr3] octreotide as carriers for somatostatinreceptor-targeted scintigraphy and radionuclide therapy
    • de Jong M, Bakker WH, Breeman WA, et al. Pre-clinicalcomparison of [DTPA0, Tyr3]octreotide and [DOTA0,D-Phe1, Tyr3] octreotide as carriers for somatostatinreceptor-targeted scintigraphy and radionuclide therapy.Int J Cancer 1998;75:406.
    • (1998) Int J Cancer , vol.75 , pp. 406
    • De Jong, M.1    Bakker, W.H.2    Breeman, W.A.3
  • 121
    • 0030737659 scopus 로고    scopus 로고
    • DOTATOC: A powerfulnew tool for receptor mediated radionuclide therapy
    • Otte A, Jermann E, Behe M, et al. DOTATOC: A powerfulnew tool for receptor mediated radionuclide therapy. Eur JNucl Med 1997;24:792.
    • (1997) Eur JNucl Med , vol.24 , pp. 792
    • Otte, A.1    Jermann, E.2    Behe, M.3
  • 122
    • 0032725922 scopus 로고    scopus 로고
    • Yttrium-90 DOTATOC:First clinical results
    • Otte A, Herrmann R, Heppeler A, et al. Yttrium-90 DOTATOC:First clinical results. Eur J Nucl Med 1999;26:1439.
    • (1999) Eur J Nucl Med , vol.26 , pp. 1439
    • Otte, A.1    Herrmann, R.2    Heppeler, A.3
  • 123
    • 0036250672 scopus 로고    scopus 로고
    • Tumor responseand clinical benefit in neuroendocrine tumors after 7.4 GBq (90)Y-DOTATOC
    • Waldherr C, Pless M, Maecke HR, et al. Tumor responseand clinical benefit in neuroendocrine tumors after 7.4 GBq(90)Y-DOTATOC. J Nucl Med 2002;43:610.
    • (2002) J Nucl Med , vol.43 , pp. 610
    • Waldherr, C.1    Pless, M.2    Maecke, H.R.3
  • 124
    • 33644616790 scopus 로고    scopus 로고
    • Survival and responseafter peptide receptor radionuclide therapy with[90Y-DOTA0,Tyr3]octreotide in patients with advancedgastroenteropancreatic neuroendocrine tumours
    • Valkema R, Pauwels S, Kvols LK, et al. Survival and responseafter peptide receptor radionuclide therapy with[90Y-DOTA0,Tyr3]octreotide in patients with advancedgastroenteropancreatic neuroendocrine tumours. SeminNucl Med 2006;36:147.
    • (2006) SeminNucl Med , vol.36 , pp. 147
    • Valkema, R.1    Pauwels, S.2    Kvols, L.K.3
  • 125
    • 36749090076 scopus 로고    scopus 로고
    • Response to [90yttrium-DOTA] TOC treatment is associated with long-term survivalbenefit in metastasized medullary thyroid cancer: Aphase II clinical trial
    • Iten F, Muller B, Schindler C, et al. Response to [90yttrium-DOTA]-TOC treatment is associated with long-term survivalbenefit in metastasized medullary thyroid cancer: Aphase II clinical trial. Clin Cancer Res 2007;13:6696.
    • (2007) Clin Cancer Res , vol.13 , pp. 6696
    • Iten, F.1    Muller, B.2    Schindler, C.3
  • 128
    • 69249213965 scopus 로고    scopus 로고
    • Complicationsfollowing radioembolization with Yttrium-90 microspheres:A comprehensive literature review
    • Riaz A, Lewandowski RJ, Kulik LM, et al. Complicationsfollowing radioembolization with Yttrium-90 microspheres:A comprehensive literature review. J Vasc IntervRadiol 2009;20:1121.
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 1121
    • Riaz, A.1    Lewandowski, R.J.2    Kulik, L.M.3
  • 129
    • 77249159529 scopus 로고    scopus 로고
    • State of the art: Radiolabeledmicrospheres treatment for liver malignancies
    • Deleporte A, Flamen P, Hendlisz A. State of the art: Radiolabeledmicrospheres treatment for liver malignancies.Expert Opin Pharmacother 2010;11:579.
    • (2010) Expert Opin Pharmacother , vol.11 , pp. 579
    • Deleporte, A.1    Flamen, P.2    Hendlisz, A.3
  • 130
    • 0024370696 scopus 로고
    • Hepatocellular carcinoma:Pilot trial of treatment with Y-90 microspheres
    • Houle S, Yip TK, Shepherd FA, et al. Hepatocellular carcinoma:Pilot trial of treatment with Y-90 microspheres.Radiology 1989;172:857.
    • (1989) Radiology , vol.172 , pp. 857
    • Houle, S.1    Yip, T.K.2    Shepherd, F.A.3
  • 131
    • 0026442830 scopus 로고
    • Glass yttrium-90 microspheres for patients with colorectal livermetastases
    • Anderson JH, Goldberg JA, Bessent RG, et al. Glass yttrium-90 microspheres for patients with colorectal livermetastases. Radiother Oncol 1992;25:137.
    • (1992) Radiother Oncol , vol.25 , pp. 137
    • Anderson, J.H.1    Goldberg, J.A.2    Bessent, R.G.3
  • 132
    • 0026778535 scopus 로고
    • A phase i doseescalation trial of yttrium-90 microspheres in the treatmentof primary hepatocellular carcinoma
    • Shepherd FA, Rotstein LE, Houle S, et al. A phase I doseescalation trial of yttrium-90 microspheres in the treatmentof primary hepatocellular carcinoma. Cancer 1992;70:2250.
    • (1992) Cancer , vol.70 , pp. 2250
    • Shepherd, F.A.1    Rotstein, L.E.2    Houle, S.3
  • 133
    • 33744739110 scopus 로고    scopus 로고
    • Treatment ofunresectable primary and metastatic liver cancer with yttrium-90 microspheres (TheraSphere): Assessment of hepatic arterialembolization
    • Sato K, Lewandowski RJ, Bui JT, et al. Treatment ofunresectable primary and metastatic liver cancer with yttrium-90 microspheres (TheraSphere): Assessment of hepatic arterialembolization. Cardiovasc Intervent Radiol 2006;29:522.
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 522
    • Sato, K.1    Lewandowski, R.J.2    Bui, J.T.3
  • 134
    • 70349576355 scopus 로고    scopus 로고
    • Yttrium-90radioembolization using TheraSphere in the managementof primary and secondary liver tumors
    • Riaz A, Lewandowski RJ, Kulik L, Salem R. Yttrium-90radioembolization using TheraSphere in the managementof primary and secondary liver tumors. Q J Nucl Med MolImaging 2009;53:311.
    • (2009) Q J Nucl Med MolImaging , vol.53 , pp. 311
    • Riaz, A.1    Lewandowski, R.J.2    Kulik, L.3    Salem, R.4
  • 135
    • 71449084950 scopus 로고    scopus 로고
    • Selective internalradiation therapy with SIR-spheres forthe treatment ofunresectable colorectal hepatic metastases
    • Cianni R, Urigo C, Notarianni E, et al. Selective internalradiation therapy with SIR-spheres forthe treatment ofunresectable colorectal hepatic metastases. Cardiovasc InterventRadiol 2009;32:1179.
    • (2009) Cardiovasc InterventRadiol , vol.32 , pp. 1179
    • Cianni, R.1    Urigo, C.2    Notarianni, E.3
  • 136
    • 70349582722 scopus 로고    scopus 로고
    • Yttrium-90 labelled resin microspheres for treatment of primaryand secondary malignant liver tumors
    • Van De Wiele C, Defreyne L, Peeters M, Lambert B. Yttrium-90 labelled resin microspheres for treatment of primaryand secondary malignant liver tumors. Q J Nucl MedMol Imaging 2009;53:317.
    • (2009) Q J Nucl MedMol Imaging , vol.53 , pp. 317
    • Van De Wiele, C.1    Defreyne, L.2    Peeters, M.3    Lambert, B.4
  • 137
    • 84870777477 scopus 로고    scopus 로고
    • Kanata, ON, Canada: MDS Nordion Accessed onApril 4, 2012
    • TheraSphere yttrium-90 microspheres [package insert].Kanata, ON, Canada: MDS Nordion. (www.accessdata.fda.gov/cdrh-docs/pdf/H980006c.pdf). Accessed onApril 4, 2012.
    • TheraSphere yttrium-90 Microspheres [Package Insert]
  • 138
    • 84870794085 scopus 로고    scopus 로고
    • Lane Cove Australia: Sirtex Medical Accessed on April 4, 2012
    • SIR-Spheres yttrium-90 microspheres [package insert].Lane Cove, Australia: Sirtex Medical. (www.sirtex.com/files/SSL-US-09.pdf). Accessed on April 4, 2012.
    • SIR-Spheres Yttrium-90 Microspheres [Package Insert]
  • 139
    • 33645345172 scopus 로고
    • Therapeutic use of Y-90 microspheres
    • Ehrhardt GJ, Day D. Therapeutic use of Y-90 microspheres.Nucl Med Biol 1987;14:233-242.
    • (1987) Nucl Med Biol , vol.14 , pp. 233-242
    • Ehrhardt, G.J.1    Day, D.2
  • 140
    • 0033778282 scopus 로고    scopus 로고
    • Treatment of nonresectablehepatocellular carcinoma with intrahepatic 90Ymicrospheres
    • Dancey JE, Shepherd FA, Paul K, et al. Treatment of nonresectablehepatocellular carcinoma with intrahepatic 90Ymicrospheres.J Nucl Med 2000;41:1673.
    • (2000) J Nucl Med , vol.41 , pp. 1673
    • Dancey, J.E.1    Shepherd, F.A.2    Paul, K.3
  • 141
    • 0027949363 scopus 로고
    • Treatment of inoperablehepatocellular carcinoma with intrahepatic arterial yttrium-90 microspheres: A phase i and II study
    • Lau WY, Leung WT, Ho S, et al. Treatment of inoperablehepatocellular carcinoma with intrahepatic arterial yttrium-90 microspheres: A phase I and II study. Br J Cancer1994;70:994.
    • (1994) Br J Cancer , vol.70 , pp. 994
    • Lau, W.Y.1    Leung, W.T.2    Ho, S.3
  • 142
    • 42149093640 scopus 로고    scopus 로고
    • Trans-arterial hepaticradioembolisation of yttrium-90 Microspheres
    • Murthy R, Habbu A, Salem R. Trans-arterial hepaticradioembolisation of yttrium-90 Microspheres. BiomedImaging Interv J 2006;2:e43.
    • (2006) BiomedImaging Interv J , vol.2
    • Murthy, R.1    Habbu, A.2    Salem, R.3
  • 143
    • 28044465731 scopus 로고    scopus 로고
    • Yttrium-90 microspheretherapy for hepatic malignancy: Devices indications,technical considerations, and potential complications
    • Murthy R, Nunez R, Szklaruk J, et al. Yttrium-90 microspheretherapy for hepatic malignancy: Devices, indications,technical considerations, and potential complications.RadioGraphics 2005;25:S41.
    • (2005) Radio Graphics , vol.25
    • Murthy, R.1    Nunez, R.2    Szklaruk, J.3
  • 144
    • 33847062079 scopus 로고    scopus 로고
    • Radioembolizationwith Yttrium-90 microspheres: Review of anemerging treatment for liver tumors
    • Gates VL, Atassi B, Lewandowski RJ, et al. Radioembolizationwith Yttrium-90 microspheres: Review of anemerging treatment for liver tumors. Future Oncol 2007;3:73.
    • (2007) Future Oncol , vol.3 , pp. 73
    • Gates, V.L.1    Atassi, B.2    Lewandowski, R.J.3
  • 145
    • 33748452993 scopus 로고    scopus 로고
    • Yttrium-90 microspheres for thetreatment of hepatocellular carcinoma: A review
    • Salem R, Hunter RD. Yttrium-90 microspheres for thetreatment of hepatocellular carcinoma: A review. Int J RadiatOncol Biol Phys 2006;66:S83.
    • (2006) Int J RadiatOncol Biol Phys , vol.66
    • Salem, R.1    Hunter, R.D.2
  • 146
    • 33750156243 scopus 로고    scopus 로고
    • Radioembolization with Yttrium-90microspheres: A state-of-the-art brachytherapy treatmentfor primary and secondary liver malignancies Part 3:Comprehensive literature review and future direction
    • Salem R, Thurston KG. Radioembolization with Yttrium-90microspheres: A state-of-the-art brachytherapy treatmentfor primary and secondary liver malignancies Part 3:Comprehensive literature review and future direction. JVasc Interv Radiol 2006;17:1571.
    • (2006) JVasc Interv Radiol , vol.17 , pp. 1571
    • Salem, R.1    Thurston, K.G.2
  • 147
    • 14844356161 scopus 로고    scopus 로고
    • Radiosynovectomy inrheumatology, orthopedics, and hemophilia
    • Schneider P, Farahati J, Reiners C. Radiosynovectomy inrheumatology, orthopedics, and hemophilia. J Nucl Med2005;46:48S.
    • (2005) J Nucl Med , vol.46
    • Schneider, P.1    Farahati, J.2    Reiners, C.3
  • 148
    • 80051735734 scopus 로고
    • Radiosynoviorthesis-Involvement of NuclearMedicine in Rheumatology and Orthopaedics
    • Meckenheim Germany: MbH
    • Modder G. Radiosynoviorthesis-Involvement of NuclearMedicine in Rheumatology and Orthopaedics. WarlichDruck und Verlagsges. Meckenheim, Germany: MbH, 1995.
    • (1995) WarlichDruck und Verlagsges
    • Modder, G.1
  • 149
    • 84870849622 scopus 로고
    • On the effect of radiothoriums on the joints
    • Ishido C. On the effect of radiothoriums on the joints.Radiotherapy 1924;15:537.
    • (1924) Radiotherapy , vol.15 , pp. 537
    • Ishido, C.1
  • 150
    • 77951353043 scopus 로고
    • The local treatment of the rheumaticdisorders
    • Fellinger K, Schmid J. The local treatment of the rheumaticdisorders. Vienna J Inn Med 1952;33:351.
    • (1952) Vienna J Inn Med , vol.33 , pp. 351
    • Fellinger, K.1    Schmid, J.2
  • 151
    • 0014402674 scopus 로고
    • Synoviorthesis withradioisotopes
    • Delbarre F, Cayla J, Menkes C, et al. Synoviorthesis withradioisotopes. Presse Med 1968;76:1045.
    • (1968) Presse Med , vol.76 , pp. 1045
    • Delbarre, F.1    Cayla, J.2    Menkes, C.3
  • 152
    • 0016735203 scopus 로고
    • Yttrium90 in persistant synovitis of the knee - A single centrecomparison. The retention and extra-articular spread offour 90Y radiocolloids
    • Gumpel JM, Beer TC, Crawley JCW, Farran HEA. Yttrium90 in persistant synovitis of the knee- A single centrecomparison. The retention and extra-articular spread offour 90Y radiocolloids. Br J Radiol 1975;48:377.
    • (1975) Br J Radiol , vol.48 , pp. 377
    • Gumpel, J.M.1    Beer, T.C.2    Crawley, J.C.W.3    Farran, H.E.A.4
  • 154
    • 67651177434 scopus 로고    scopus 로고
    • Bioevaluation of 90Ylabeledparticles in animal model of arthritis
    • Pandey U, Ketaki B, Sarma HD, et al. Bioevaluation of 90Ylabeledparticles in animal model of arthritis. Ann NuclMed 2009;23:333.
    • (2009) Ann NuclMed , vol.23 , pp. 333
    • Pandey, U.1    Ketaki, B.2    Sarma, H.D.3
  • 155
    • 0034743147 scopus 로고    scopus 로고
    • Preparationand studies with 90Y-labelled particles for use in radiationsynovectomy
    • Pandey U, Mukherjee A, Chaudhary PR, et al. Preparationand studies with 90Y-labelled particles for use in radiationsynovectomy. Appl Radiat Isot 2001;55:471.
    • (2001) Appl Radiat Isot , vol.55 , pp. 471
    • Pandey, U.1    Mukherjee, A.2    Chaudhary, P.R.3
  • 156
    • 1542500183 scopus 로고    scopus 로고
    • EANM Procedureguidelines for radiosynovectomy
    • European Association of Nuclear Medicine
    • European Association of Nuclear Medicine. EANM Procedureguidelines for radiosynovectomy. Eur J Nucl Med2003;30:BP12.
    • (2003) Eur J Nucl Med , vol.30
  • 157
    • 64949177392 scopus 로고    scopus 로고
    • Yttrium-90 silicate radiosynovectomytreatment of painful synovitis in knee osteoarthritis. Results after 6months
    • Markou P, Chatzopoulos D. Yttrium-90 silicate radiosynovectomytreatment of painful synovitis in knee osteoarthritis.Results after 6months. Hell JNuclMed 2009;12:33-36.
    • (2009) Hell J Nucl Med , vol.12 , pp. 33-36
    • Markou, P.1    Chatzopoulos, D.2
  • 158
    • 0017053288 scopus 로고
    • Distributionof yttrium 90 ferric hydroxide colloid and gold 198colloid after injection into knee
    • Williams ED, Caughey DE, Hurley PJ, John MB. Distributionof yttrium 90 ferric hydroxide colloid and gold 198colloid after injection into knee. Ann Rheum Dis1976;35:516.
    • (1976) Ann Rheum Dis , vol.35 , pp. 516
    • Williams, E.D.1    Caughey, D.E.2    Hurley, P.J.3    John, M.B.4
  • 159
    • 0024383971 scopus 로고
    • Radiopharmaceuticals for radiationsynovectomy: Evaluation of two Yttrium-90 particulateagents
    • Davis MA, Chinol M. Radiopharmaceuticals for radiationsynovectomy: Evaluation of two Yttrium-90 particulateagents. J Nucl Med 1989;30:1047.
    • (1989) J Nucl Med , vol.30 , pp. 1047
    • Davis, M.A.1    Chinol, M.2
  • 160
    • 34547678162 scopus 로고    scopus 로고
    • Colloidal 90Yused for radiation synovectomy decreases the viability ofchondrocytes in human cadaveric samples
    • Brecelj J, Gmeiner-Stopar T, Jevsek M, et al. Colloidal 90Yused for radiation synovectomy decreases the viability ofchondrocytes in human cadaveric samples. Nucl MedCommun 2007;28:704.
    • (2007) Nucl Med Commun , vol.28 , pp. 704
    • Brecelj, J.1    Gmeiner-Stopar, T.2    Jevsek, M.3
  • 161
    • 0030696350 scopus 로고    scopus 로고
    • A retrospectivereview of Yttrium-90 synovectomy in the treatment of kneearthritis
    • Taylor WJ, Corkill MM, Rajapaske CNA. A retrospectivereview of Yttrium-90 synovectomy in the treatment of kneearthritis. Br J Rheumatol 1997;36:1100.
    • (1997) Br J Rheumatol , vol.36 , pp. 1100
    • Taylor, W.J.1    Corkill, M.M.2    Rajapaske, C.N.A.3
  • 162
    • 33845578112 scopus 로고    scopus 로고
    • Therapeuticstatus of radiosynoviorthesis of the knee with yttrium [90Y] colloid in rheumatoid arthritis and related indications
    • Kampen WU, Voth M, Pinkert J, Krause A. Therapeuticstatus of radiosynoviorthesis of the knee with yttrium [90Y]colloid in rheumatoid arthritis and related indications.Rheumatology 2007;46:16.
    • (2007) Rheumatology , vol.46 , pp. 16
    • Kampen, W.U.1    Voth, M.2    Pinkert, J.3    Krause, A.4
  • 163
    • 33750355464 scopus 로고    scopus 로고
    • Radiation synovectomy with yttrium-90 for persisting arthritishas direct harmful effects on human cartilage thatcannot be prevented by co-administration of glucocorticoids:An in vitro study
    • Jahangier ZN, Jacobs KMG, Bijlsma JWJ, Lafeber FPJG.Radiation synovectomy with yttrium-90 for persisting arthritishas direct harmful effects on human cartilage thatcannot be prevented by co-administration of glucocorticoids:An in vitro study. Ann Rheum Dis 2006;65:1384.
    • (2006) Ann Rheum Dis , vol.65 , pp. 1384
    • Jahangier, Z.N.1    Jacobs, K.M.G.2    Bijlsma, J.W.J.3    Lafeber, F.P.J.G.4
  • 165
    • 0033867566 scopus 로고    scopus 로고
    • Yttrium radiosynoviorthesis in the treatment of knee arthritisin rheumatoid arthritis: A systematic review
    • Heuft-Dorenbosch LLJ, de Vet HCW, van der Linden S.Yttrium radiosynoviorthesis in the treatment of knee arthritisin rheumatoid arthritis: A systematic review. AnnRheum Dis 2000;59:583.
    • (2000) AnnRheum Dis , vol.59 , pp. 583
    • Heuft-Dorenbosch, L.L.J.1    De Vet, H.C.W.2    Van Der Linden, S.3
  • 166
    • 0008404690 scopus 로고
    • A contolled trial ofintra-articular yttrium-90, osmic acid and triamcinolonehexacetonide in rheumatoid arthritis
    • San Francisco, Maryland: Lippincott Williams and Wilkins
    • Menkes C, Go LA, Verrier P, Delbarre F. A contolled trial ofintra-articular yttrium-90, osmic acid and triamcinolonehexacetonide in rheumatoid arthritis. Proceedings of theXIV Congress Rheumatology, San Francisco, Maryland:Lippincott Williams and Wilkins, 1977:614.
    • (1977) Proceedings of TheXIV Congress Rheumatology , pp. 614
    • Menkes, C.1    Go, L.A.2    Verrier, P.3    Delbarre, F.4
  • 167
    • 0021966214 scopus 로고
    • Radiosynovectomyin chronic synovitis of the knee joint in patientswith rheumatoid arthritis
    • Boerbooms AM, Buijs WC, Danen M, et al. Radiosynovectomyin chronic synovitis of the knee joint in patientswith rheumatoid arthritis. Eur J Nucl Med 1985;10:446.
    • (1985) Eur J Nucl Med , vol.10 , pp. 446
    • Boerbooms, A.M.1    Buijs, W.C.2    Danen, M.3
  • 168
    • 0018333581 scopus 로고
    • Double-blind trial of 90Y forchronic inflammatory synovitis of the knee
    • Yates DB, Scott JT, Ramsey N. Double-blind trial of 90Y forchronic inflammatory synovitis of the knee. RheumatolRehabil 1979;18:46.
    • (1979) RheumatolRehabil , vol.18 , pp. 46
    • Yates, D.B.1    Scott, J.T.2    Ramsey, N.3
  • 169
    • 0032588615 scopus 로고    scopus 로고
    • Similarities anddifferences in 111In-and 90Y-Labeled 1B4M-DTPA AntiTacMonoclonal antibody distribution
    • Carrasquillo JA, White JD, Paik CH, et al. Similarities anddifferences in 111In-and 90Y-Labeled 1B4M-DTPA AntiTacMonoclonal antibody distribution. J Nucl Med 1999;40:268.
    • (1999) J Nucl Med , vol.40 , pp. 268
    • Carrasquillo, J.A.1    White, J.D.2    Paik, C.H.3
  • 170
    • 33751416214 scopus 로고    scopus 로고
    • Radiopharmaceuticalmanagement of 90Y/111In labeled antibodies:Shielding and quantification during preparationand administration
    • Hemert FJ, Sloof GW, Schimmel KJM, et al. Radiopharmaceuticalmanagement of 90Y/111In labeled antibodies:Shielding and quantification during preparationand administration. Ann Nucl Med 2006;20:575.
    • (2006) Ann Nucl Med , vol.20 , pp. 575
    • Hemert, F.J.1    Sloof, G.W.2    Schimmel, K.J.M.3
  • 171
    • 0036074272 scopus 로고    scopus 로고
    • Comparison ofYttrium and Indium complexes of DOTA-BA and DOTAMBA:Models for 90Y-and 111In-labeled DOTA-biomoleculeconjugates
    • Liu S, Pietryka J, Ellars CE, Edwards DS. Comparison ofYttrium and Indium complexes of DOTA-BA and DOTAMBA:Models for 90Y-and 111In-labeled DOTA-biomoleculeconjugates. Bioconjugate Chem 2002;13:902.
    • (2002) Bioconjugate Chem , vol.13 , pp. 902
    • Liu, S.1    Pietryka, J.2    Ellars, C.E.3    Edwards, D.S.4
  • 172
    • 79957948621 scopus 로고    scopus 로고
    • Dosimetry ofyttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?
    • Walrand S, Flux GD, Konijnenberg MW, et al. Dosimetry ofyttrium-labelled radiopharmaceuticals for internal therapy:86Y or 90Y imaging? Eur J Nucl Med Mol Imaging2011;38:S57.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38
    • Walrand, S.1    Flux, G.D.2    Konijnenberg, M.W.3
  • 173
    • 0038583768 scopus 로고    scopus 로고
    • PET imagingwith yttrium-86: Comparison of phantom measurementsacquired with different PET scanners before and after applyingbackground subtraction
    • Buchholz HG, Herzog H, Forster GJ, et al. PET imagingwith yttrium-86: Comparison of phantom measurementsacquired with different PET scanners before and after applyingbackground subtraction. Eur J Nucl Med Mol Imaging2003;30:716.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 716
    • Buchholz, H.G.1    Herzog, H.2    Forster, G.J.3
  • 175
    • 84862666325 scopus 로고    scopus 로고
    • Feasibility ofbremsstrahlung dosimetry for direct dose estimation inpatients undergoing treatment with 90Y-ibritumomabtiuxetan
    • Arrichiello C, Aloj L, Mormile M, et al. Feasibility ofbremsstrahlung dosimetry for direct dose estimation inpatients undergoing treatment with 90Y-ibritumomabtiuxetan. Eur J Nucl Med Mol Imaging 2012;39:956.
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , pp. 956
    • Arrichiello, C.1    Aloj, L.2    Mormile, M.3
  • 176
    • 69449088669 scopus 로고    scopus 로고
    • 68Ga-DOTA-Tyr3-octreotide PET for assessing response to somatostatin-receptor-mediated radionuclide therapy
    • Gabriel M, Oberauer A, Dobrozemsky G, et al. 68Ga-DOTA-Tyr3-octreotide PET for assessing response to somatostatin-receptor-mediated radionuclide therapy. J NuclMed 2009;50:1427.
    • (2009) J Nucl Med , vol.50 , pp. 1427
    • Gabriel, M.1    Oberauer, A.2    Dobrozemsky, G.3
  • 177
    • 84870774903 scopus 로고    scopus 로고
    • Evaluation of 68Ga/111In-SIR-Spheres as a novel PET/SPECT imaging surrogate of90Y-SIR-Spheres
    • Wu SY, Chang TK, Kuo JW, et al. Evaluation of 68Ga/111In-SIR-Spheres as a novel PET/SPECT imaging surrogate of90Y-SIR-Spheres. J Nucl Med 2010;51:1553.
    • (2010) J Nucl Med , vol.51 , pp. 1553
    • Wu, S.Y.1    Chang, T.K.2    Kuo, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.