메뉴 건너뛰기




Volumn 36, Issue 1-6 SPEC., 2003, Pages 761-766

Sr/Y separation by supported liquid membranes based on nuclear track micro filters

Author keywords

Generator; Nuclear tracks micro filters; Supported liquid membrane; Y 90

Indexed keywords

GAMMA RAY SPECTROMETERS; LIQUID MEMBRANES; PORE SIZE; POROSITY; RADIOTHERAPY;

EID: 0041862723     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(03)00242-7     Document Type: Conference Paper
Times cited : (31)

References (12)
  • 1
    • 0001657357 scopus 로고    scopus 로고
    • Incomplete trapping in supported liquid membrane extraction with a stagnant acceptor for weak bases
    • Chimuka L., Megersa N., Norberg J., Mathiasson L., Jonsson J.A. Incomplete trapping in supported liquid membrane extraction with a stagnant acceptor for weak bases. Anal. Chem. 70(18):1998;3906-3911.
    • (1998) Anal. Chem. , vol.70 , Issue.18 , pp. 3906-3911
    • Chimuka, L.1    Megersa, N.2    Norberg, J.3    Mathiasson, L.4    Jonsson, J.A.5
  • 3
    • 0031407782 scopus 로고    scopus 로고
    • 90Sr in environmental samples
    • 90Sr in environmental samples J. Radioanal. Nucl. Chem. 226(1-2):1997;55-60.
    • (1997) J. Radioanal. Nucl. Chem. , vol.226 , Issue.1-2 , pp. 55-60
    • Friberg, I.1
  • 4
    • 0022408741 scopus 로고
    • DTPA coupled anti-bodies labelled with Y-90
    • Hnatowich D.J., Virzi F., Doherty P.W. DTPA coupled anti-bodies labelled with Y-90. J. Nucl. Med. 26(5):1985;503-509.
    • (1985) J. Nucl. Med. , vol.26 , Issue.5 , pp. 503-509
    • Hnatowich, D.J.1    Virzi, F.2    Doherty, P.W.3
  • 5
    • 0344780907 scopus 로고    scopus 로고
    • Liquid membrane extraction in analytical sample preparation
    • Jönsson J.A., Mathiasson L. Liquid membrane extraction in analytical sample preparation. Trends Anal. Chem. 18(5):1999;318-334.
    • (1999) Trends Anal. Chem. , vol.18 , Issue.5 , pp. 318-334
    • Jönsson, J.A.1    Mathiasson, L.2
  • 6
    • 0027152273 scopus 로고
    • Mass transfer kinetics for analytical enrichment and sample preparation using supported liquid membranes in a flow system with stagnant acceptor liquid
    • Jönsson J.A., Loevkvist P., Audunsson G., Nilve G. Mass transfer kinetics for analytical enrichment and sample preparation using supported liquid membranes in a flow system with stagnant acceptor liquid. Anal. Chim. Acta. 277:1993;9-24.
    • (1993) Anal. Chim. Acta , vol.277 , pp. 9-24
    • Jönsson, J.A.1    Loevkvist, P.2    Audunsson, G.3    Nilve, G.4
  • 8
    • 0035944953 scopus 로고    scopus 로고
    • Kinetics of europium(III) transport through a liquid membrane containing HEH(EHP) in kerosene
    • Ma M., He D., Wang Q., Xie Q. Kinetics of europium(III) transport through a liquid membrane containing HEH(EHP) in kerosene. Talanta. 55:2001;1109-1117.
    • (2001) Talanta , vol.55 , pp. 1109-1117
    • Ma, M.1    He, D.2    Wang, Q.3    Xie, Q.4
  • 11
    • 50849146283 scopus 로고
    • Production and application of nuclear track microfilters
    • Vater P. Production and application of nuclear track microfilters. Nucl. Tracks Radiat. Meas. 15:1988;743-749.
    • (1988) Nucl. Tracks Radiat. Meas. , vol.15 , pp. 743-749
    • Vater, P.1
  • 12
    • 0041361930 scopus 로고    scopus 로고
    • Nuclear Track microfilters: Gas separation ability and β -radiation stability
    • submitted for publication
    • Vater, P., Happel, S., Sudowe, R., Brandt, R., Ensinger, W., 2003. Nuclear Track microfilters: gas separation ability and β -radiation stability. Radiat. Meas., submitted for publication.
    • (2003) Radiat. Meas.
    • Vater, P.1    Happel, S.2    Sudowe, R.3    Brandt, R.4    Ensinger, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.